Jong-Woong Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jong-Woong Lee has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Dae Cheol Kweon
Department of Radiological Science, Shinhan University, Uijeongbu, Republic of Korea
5 shared publications - Kyung-Rae Dong
Department of Radiological Technology , Gwangju Health University , Gwangju , Republic of Korea ; Department of Nuclear Engineering , Chosun University , Gwangju , Republic of Korea
5 shared publications - Woon-Kwan Chung
Department of Nuclear Engineering, Chosun University, Gwangju, Republic of Korea
5 shared publications - Jiwon Choi
Department of Radiological Science, Jeonju University, Jeonju, Republic of Korea
4 shared publications - Chong-Hwan Choe
Department of White Memorial Medical Center
2 shared publications - Eun-Hoe Goo
Seoul National University Hospital
2 shared publications
Latest Publications
- 31 March 2016
- Published by The Korean Magnetics Society in Journal of Magnetics
- Vol. 21 (1) , 115-124
Effects of Contrast Agent Concentration on the Signal Intensity and Turbo Factor of TSE and Slice-selective IR in T1-weighted Contrast Imaging
- 31 March 2016
- Published by The Korean Magnetics Society in Journal of Magnetics
- Vol. 21 (1) , 115-124
Effects of Contrast Agent Concentration on the Signal Intensity and Turbo Factor of TSE and Slice-selective IR in T1-weighted Contrast Imaging
- 17 September 2013
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 169 (2) , 165-174
Measurement of X-ray for the dose area product and spectrum by the added filtration in Rando phantom
The most important point in the medical use of radiation is to minimize the patient entrance dose while maintaining the diagnostic information. Low-energy photons (long-wave X-ray) are unnecessary among diagnostic X-ray because they are mostly absorbed and increase the patient's entrance dose. The most effective method to eliminate the low-energy photon is use of a filtering plate. Using a filter appropriate for the image will maintain diagnostic value. Obtaining an effective image allows comparison of the resulting images in a logical objective way. This experiment was performed to determine the quality of image dosimeter when there is no filter, and when 2 mm Al, 0.1 mm Cu + 1 mm Al, 0.2 mm Cu + 1 mm Al filters are used. Using TORECK PD-8100 dose area products meter placed on top of an abdominal phantom, we measured the dose when the filter changes in this condition 85 kVp, 40 mAs, anode angle 13, source image distance 100 cm, 20 cm × 20 cm. We used the SRS-78 program for accurate comparison because we could not evaluate the difference in the image optically. The spectrum changed due to the emission of X-rays as the filter changed. We observed that the use of a filter eliminated the low-energy photons and revealed continuous X-ray and special X-ray. Therefore, the experiment highlighted the advantages of filters and confirmed that there are no changes in the quality of image through signal to noise ratio, peak signal to noise ratio, root mean square error comparison. We found that the use of filter did not lead to distortions in the image or drop in diagnostic value while minimizing the radiation dose. This means that it can help manage long-term patient dose. We conclude that we need to recommend the use of the filter as it reduces the area of dose.
- 17 September 2013
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 169 (2) , 165-174
Measurement of X-ray for the dose area product and spectrum by the added filtration in Rando phantom
The most important point in the medical use of radiation is to minimize the patient entrance dose while maintaining the diagnostic information. Low-energy photons (long-wave X-ray) are unnecessary among diagnostic X-ray because they are mostly absorbed and increase the patient's entrance dose. The most effective method to eliminate the low-energy photon is use of a filtering plate. Using a filter appropriate for the image will maintain diagnostic value. Obtaining an effective image allows comparison of the resulting images in a logical objective way. This experiment was performed to determine the quality of image dosimeter when there is no filter, and when 2 mm Al, 0.1 mm Cu + 1 mm Al, 0.2 mm Cu + 1 mm Al filters are used. Using TORECK PD-8100 dose area products meter placed on top of an abdominal phantom, we measured the dose when the filter changes in this condition 85 kVp, 40 mAs, anode angle 13, source image distance 100 cm, 20 cm × 20 cm. We used the SRS-78 program for accurate comparison because we could not evaluate the difference in the image optically. The spectrum changed due to the emission of X-rays as the filter changed. We observed that the use of a filter eliminated the low-energy photons and revealed continuous X-ray and special X-ray. Therefore, the experiment highlighted the advantages of filters and confirmed that there are no changes in the quality of image through signal to noise ratio, peak signal to noise ratio, root mean square error comparison. We found that the use of filter did not lead to distortions in the image or drop in diagnostic value while minimizing the radiation dose. This means that it can help manage long-term patient dose. We conclude that we need to recommend the use of the filter as it reduces the area of dose.
- 30 November 2011
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 38 (11) , 2569-2574
Comparison of dose-volume histograms for Tomo therapy, linear accelerator-based 3D conformal radiation therapy, and intensity-modulated radiation therapy
- 30 November 2011
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 38 (11) , 2569-2574
Comparison of dose-volume histograms for Tomo therapy, linear accelerator-based 3D conformal radiation therapy, and intensity-modulated radiation therapy
- 23 September 2011
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 42 (2) , 239-249
Diagnosing Aortic Stenosis Using Phase Contrast MRI: Comparison with Echocardiography Depending on the Image Plane
- 23 September 2011
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 42 (2) , 239-249
Diagnosing Aortic Stenosis Using Phase Contrast MRI: Comparison with Echocardiography Depending on the Image Plane
- 13 March 2011
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 40 (3) , 291-301
Signal Intensity for Contrast Enhancement as a Function of the Molarity of Gadolinium-Based MRI Contrast Media
- 13 March 2011
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 40 (3) , 291-301
Signal Intensity for Contrast Enhancement as a Function of the Molarity of Gadolinium-Based MRI Contrast Media
- 27 February 2011
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 40 (2) , 221-229
Flip Angle for the Optimal T 1-weighted Image in the 3-D Volumetric Interpolated Breath-hold Examination Abdominal Magnetic Resonance Imaging Technique
- 27 February 2011
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 40 (2) , 221-229
Flip Angle for the Optimal T 1-weighted Image in the 3-D Volumetric Interpolated Breath-hold Examination Abdominal Magnetic Resonance Imaging Technique
- Retracted
- 15 February 2011
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 58 (2) , 334-342
Measurement of Image Quality in CT Images Reconstructed with Different Kernels
- 15 February 2011
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 58 (2) , 334-342
RetractedMeasurement of Image Quality in CT Images Reconstructed with Different Kernels