Latest Publications

  • Open Access

    AAPM Medical Physics Practice Guideline 18.a: Superficial radiation therapy using low‐energy kilovoltage x‐rays

    by Yongsook C. Lee, Seng Boh Lim, Peter M. Mondalek, Sergio O´rEilly, David G. Saez, Ren‐Dih Sheu, Gerald A. White, Strahinja Stojadinovic

    Superficial radiation therapy (SRT), utilizing low‐energy kilovoltage (kV) x‐rays typically in the 50–100 kVp range, is a well‐established modality in dermatology and radiation oncology clinics for the management of non‐melanoma skin cancer and various benign dermatological conditions. The comprehensive medical physics practice guidelines presented in this report are designed to facilitate adherence to minimum standards for SRT delivery. A technical overview of commercially available SRT systems in the United States is provided. Detailed guidelines for commissioning and routine quality assurance are presented, specifying daily, monthly, and annual tests, alongside established action limits. The SRT clinical workflow is delineated, encompassing patient simulation, treatment time or monitor unit calculations, data entry, independent treatment plan review, and radiation delivery. A summary of typical state regulatory requirements for x‐ray machines is included. Adherence to relevant state regulations is emphasized and radiation safety considerations, comprising structural shielding, radiation surveys, personnel monitoring, signage, periodic spot checks, and machine operation, are discussed to ensure a safe and effective clinical environment. References to relevant societal practice guidance are provided to support standardized clinical implementation.

  • Open Access

    Region of interest selection and volume averaging for Gamma Knife radiochromic film dosimetry

    by Jingying Lin, Stevan Pecic, Thomas I Banks, Slobodan Devic, Strahinja Stojadinovic

    Objective. Accurate determination of relative output factors (ROFs) is paramount in stereotactic radiosurgery dosimetry, particularly for small fields employed in Leksell Gamma Knife (LGK) systems. Existing guidelines for LGK film-based dosimetry lack specificity regarding the selection of a region of interest (ROI) for ROF measurements. Approach. This investigation assessed the dosimetric performance of Gafchromic TM EBT4 film, focusing on establishing a quantitative metric for the unambiguous selection of a small ROI, defined relative to the beam’s full width at half maximum (FWHM), for LGK ROF measurements. Film irradiations were performed on an LGK ICON unit using 16-, 8-, and 4 mm collimators. Calibration curves were generated by irradiating 15 films with 16 mm beams in 15 s increments, with films subsequently scanned in both portrait and landscape orientations at various resolutions. Dosimetric accuracy was assessed using the net optical density transfer function along with corresponding uncertainty propagation. The influence of detector size on ROF determination was calculated using ROIs with diameters systematically varied to include 1/10, 1/5, 1/4, 1/3, 2/5, 1/2, 2/3, and 3/4 of the beam’s FWHM. Main results. ROF measurements demonstrated high sensitivity to ROI size. A metric employing a ¼ FWHM ROI yielded ROFs values within 1% of the established Leksell GammaPlan (LGP) reference data, effectively minimizing film volume-averaging effects. Systematic dose errors, up to ±20% on average, were observed due to orientation mismatches between calibration and measurement scans. Furthermore, across all evaluated scan resolutions both FWHM and penumbra measurements consistently conformed to LGP specifications, specifically within ±0.5 mm and ±1 mm, respectively. Significance. The ¼ FWHM ROI provides a clinically practical method for LGK ROF determination, addressing the absence of a clear ROI definition in TG-178 report. This metric achieves a suitable balance for film-based measurements, ensuring a sufficient number of ROI pixels for statistical significance while minimizing volume-averaging effects.

  • Open Access

    Establishing an Electron FLASH Platform for Preclinical Research in Low-Resource Settings

    by Banghao Zhou, Lixiang Guo, Weiguo Lu, Mahbubur Rahman, Rongxiao Zhang, Varghese Anto Chirayath, Yang Kyun Park, Strahinja Stojadinovic, Marvin Garza, Ken Kang-Hsin Wang

    Background: FLASH radiotherapy delivers ultra-high dose rates with normal tissue sparing, but mechanisms remain unclear. We present a streamlined workflow for establishing a LINAC-based electron FLASH (eFLASH) platform in low-resource settings without requiring vendor-proprietary hardware or software, or vendor-assisted modifications to broaden accessibility for FLASH studies. Methods: A LINAC was converted to eFLASH with pulse control and monitoring. Automatic frequency control (AFC) was optimized to stabilize dose per pulse (DPP). Beam data were measured with EBT-XD films, and a Monte Carlo (MC) model was commissioned for in vivo dose calculation. We demonstrated in vivo dosimetry in planning studies of mouse whole-brain and rat spinal cord (C1–T2) irradiation. We further assessed the impact of AFC optimization on the FLASH spinal cord study. Results: AFC optimization stabilized DPP at ~0.6 Gy/pulse, reducing large fluctuations under the default setting. MC agreed with measurements within 2% for PDDs and profiles. MC planning showed uniform whole-brain irradiation with 6 MeV FLASH, while the spinal cord study exhibited up to 10% dose fall-off within 1 cm along the cord, suggesting potential dose-volume effects confounding FLASH sparing. Following AFC optimization, 50% of the C1–T2 cord reached >133 Gy/s, a 23% increase versus default. Conclusions: We demonstrated a cost-effective eFLASH platform and verified its accuracy for preclinical studies, expanding the accessibility of FLASH research.


  • Open Access

    Spectral characterization and comparison of EBT3, EBT4, and EBT-XD radiochromic films

    by S Pecić, S Dević, I Belča, M Mošić, Lj Kurij, B Nidžović, S Stojadinović

    This study analyzed the spectral response of EBT3, EBT4, and EBT-XD radiochromic films using absorption spectroscopy. The primary focus was on characterizing the evolution of spectral signatures across a range of absorbed doses, thereby elucidating the unique dose-dependent response profiles of each film type. Ten samples of each film type were subjected to open field irradiation within their designated dose ranges (1–20 Gy for EBT3 and EBT4, 1–50 Gy for EBT-XD). The corresponding absorption spectra were recorded and studied via decomposition and parameterization of dose-dependent spectral features. Lorentzian profiles were employed for spectral decomposition. Each film type displayed unique spectral signatures with distinct absorption peaks: nine for EBT3, eleven for EBT4, and twelve constituent profiles for EBT-XD. Notably, the EBT4 film demonstrated a slight difference in the blue part of the absorption spectrum and a change in the response, relative to its EBT3 predecessor. Orientation dependence of the film spectra was most pronounced for the EBT3 film type, followed by a declining trend across EBT4 and EBT-XD films. Absorption spectroscopy portrayed distinct spectral fingerprints of the studied film types, aiding the selection of the most suitable film for specific applications.


  • Open Access

    Multiomics-Based Outcome Prediction in Personalized Ultra-Fractionated Stereotactic Adaptive Radiotherapy (PULSAR)

    by Haozhao Zhang, Michael Dohopolski, Strahinja Stojadinovic, Luiza Giuliani Schmitt, Soummitra Anand, Heejung Kim, Arnold Pompos, Andrew Godley, Steve Jiang, Tu Dan, et al.

    Objectives: This retrospective study aims to develop a multiomics approach that integrates radiomics, dosiomics, and delta features to predict treatment responses in brain metastasis (BM) patients undergoing PULSAR. Methods: A retrospective study encompassing 39 BM patients with 69 lesions treated with PULSAR was undertaken. Radiomics, dosiomics, and delta features were extracted from both pre-treatment and intra-treatment MRI scans alongside dose distributions. Six individual models, alongside an ensemble feature selection (EFS) model, were evaluated. The classification task focused on distinguishing between two lesion groups based on whether they exhibited a volume reduction of more than 20% at follow-up. Performance metrics, including sensitivity, specificity, accuracy, precision, F1 score, and the area under the receiver operating characteristic (ROC) curve (AUC), were assessed. Results: The EFS model integrated the features from pre-treatment radiomics, pre-treatment dosiomics, intra-treatment radiomics, and delta radiomics. It outperformed six individual models, achieving an AUC of 0.979, accuracy of 0.917, and F1 score of 0.821. Among the top nine features of the EFS model, six features came from post-wavelet transformation and three from original images. Conclusions: The study demonstrated the feasibility of employing a data-driven multiomics approach to predict treatment outcomes in BM patients receiving PULSAR treatment. Integrating multiomics with intra-treatment decision support in PULSAR shows promise for optimizing patient management and reducing the risks of under- or over-treatment.


  • Open Access

    Dynamic range and optimization strategies for radiochromic film calibration using gradient radiation fields

    by Stevan Pecic, Ivan Belca, Strahinja Stojadinovic, Borko Nidzovic, Milos Vicic, Slobodan Devic

    This investigation aimed to optimize gradient positioning for radiochromic film calibration to facilitate a uniform distribution of calibration points. The study investigated the influence of various parameters on gradient dose profiles generated by a physical wedge, assessing their impact on the field's dose dynamic range, a scalar quantity representing the span of absorbed doses. Numerical parameterization of the physical wedge profile was used to visualize and quantify the impact of field size, depth, and energy on the dynamic range of dose gradients. This concept enabled the optimization of the gradient positioning and estimation of the necessary number of exposures for the desired calibration dose range. An optimization algorithm based on histogram bin height minimization was developed and presented. The maximum dynamic range was achieved with a 20 20 field size at 5 cm depth. Optimization of wedge gradient positioning yielded the most uniform dose distribution with 7 exposures for the [1,10] Gy range and 8 exposures for the [1,20] Gy range. Film calibration using gradients centered at 1.6, 3, 3.5, and 7 Gy central axis (CAX), obtained through optimized gradient positioning, was showcased. The presented work demonstrates the potential for an improved film calibration process, with efficient material utilization and enhanced dosimetric accuracy for clinical applications. While the method was described for the use of a physical wedge, the methodology can be easily extended to the use of a more convenient dynamic wedge.

  • Open Access

    Where Does Auto-Segmentation for Brain Metastases Radiosurgery Stand Today?

    by Matthew Kim, Jen-Yeu Wang, Weiguo Lu, Hao Jiang, Strahinja Stojadinovic, Zabi Wardak, Tu Dan, Robert Timmerman, Lei Wang, Cynthia Chuang, et al.

    Detection and segmentation of brain metastases (BMs) play a pivotal role in diagnosis, treatment planning, and follow-up evaluations for effective BM management. Given the rising prevalence of BM cases and its predominantly multiple onsets, automated segmentation is becoming necessary in stereotactic radiosurgery. It not only alleviates the clinician’s manual workload and improves clinical workflow efficiency but also ensures treatment safety, ultimately improving patient care. Recent strides in machine learning, particularly in deep learning (DL), have revolutionized medical image segmentation, achieving state-of-the-art results. This review aims to analyze auto-segmentation strategies, characterize the utilized data, and assess the performance of cutting-edge BM segmentation methodologies. Additionally, we delve into the challenges confronting BM segmentation and share insights gleaned from our algorithmic and clinical implementation experiences.


  • Open Access

    Machine characterization and central axis depth dose data of a superficial x-ray radiotherapy unit

    by Zhenyu Xiong, Yuncheng Zhong, Thomas I. Banks, Robert Reynolds, Tsuicheng Chiu, Jun Tan, You Zhang, David Parsons, Yulong Yan, Andrew Godley, et al.

    Objectives. The purpose of this study is to present data from the clinical commissioning of an Xstrahl 150 x-ray unit used for superficial radiotherapy, Methods. Commissioning tasks included vendor acceptance tests, timer reproducibility, linearity and end-effect measurements, half-value layer (HVL) measurements, inverse square law verification, head-leakage measurements, and beam output calibration. In addition, percent depth dose (PDD) curves were determined for different combinations of filter/kV settings and applicators. Automated PDD water phantom scans were performed utilizing four contemporary detectors: a microDiamond detector, a microSilicon detector, an EDGE detector, and a PinPoint ionization chamber. The measured PDD data were compared to the published values in BJR Supplement 25, Results. The x-ray unit’s mechanical, safety, and radiation characteristics were within vendor-stated specifications. Across sixty commissioned x-ray beams, the PDDs determined in water using solid state detectors were in excellent agreement with the BJR 25 data. For the lower (2 collimator was (−0.7 ± 1.0)%, Conclusions. This study presents machine characterization data collected for clinical use of a superficial x-ray unit. Special focus was placed on utilizing contemporary detectors and techniques for the relative PDD measurements using a motorized water phantom. The results in this study confirm that the aggregate values published in the BJR 25 report still serve as a valid benchmark when comparing data from site-specific measurements, or the reference data for clinical utilization without such measurements, Advances in knowledge. This paper presents comprehensive data from the acceptance and commissioning of a modern kilovoltage superficial x-ray radiotherapy machine. Comparisons between the PDD data measured in this study using different detectors and BJR 25 data are highlighted.


  • Ensemble learning for glioma patients overall survival prediction using pre-operative MRIs

    by Zi Yang, Mingli Chen, Mahdieh Kazemimoghadam, Lin Ma, Strahinja Stojadinovic, Zabi Wardak, Robert Timmerman, Tu Dan, Weiguo Lu, Xuejun Gu

    Objective : Gliomas are the most common primary brain tumors. Approximately 70% of the glioma patients diagnosed with glioblastoma have an averaged overall survival (OS) of only ∼16 months. Early survival prediction is essential for treatment decision-making in glioma patients. Here we proposed an ensemble learning approach to predict the post-operative OS of glioma patients using only pre-operative MRIs. Approach : Our dataset was from the Medical Image Computing and Computer Assisted Intervention Brain Tumor Segmentation challenge 2020, which consists of multimodal pre-operative MRI scans of 235 glioma patients with survival days recorded. The backbone of our approach was a Siamese network consisting of twinned ResNet-based feature extractors followed by a 3-layer classifier. During training, the feature extractors explored traits of intra and inter-class by minimizing contrastive loss of randomly paired 2D pre-operative MRIs, and the classifier utilized the extracted features to generate labels with cost defined by cross-entropy loss. During testing, the extracted features were also utilized to define distance between the test sample and the reference composed of training data, to generate an additional predictor via K-NN classification. The final label was the ensemble classification from both the Siamese model and the K-NN model. Main results : Our approach classifies the glioma patients into 3 OS classes: long-survivors (>15 months), mid-survivors (between 10 and 15 months) and short-survivors (Significance : Our Siamese network based ensemble learning approach demonstrated promising ability in mining discriminative features with minimal manual processing and generalization requirement. This prediction strategy can be potentially applied to assist timely clinical decision-making.


  • Deep-learning and radiomics ensemble classifier for false positive reduction in brain metastases segmentation

    by Zi Yang, Mingli Chen, Mahdieh Kazemimoghadam, Lin Ma, Strahinja Stojadinovic, Robert Timmerman, Tu Dan, Zabi Wardak, Weiguo Lu, Xuejun Gu

    Stereotactic radiosurgery (SRS) is now the standard of care for brain metastases (BMs) patients. The SRS treatment planning process requires precise target delineation, which in clinical workflow for patients with multiple (>4) BMs (mBMs) could become a pronounced time bottleneck. Our group has developed an automated BMs segmentation platform to assist in this process. The accuracy of the auto-segmentation, however, is influenced by the presence of false-positive segmentations, mainly caused by the injected contrast during MRI acquisition. To address this problem and further improve the segmentation performance, a deep-learning and radiomics ensemble classifier was developed to reduce the false-positive rate in segmentations. The proposed model consists of a Siamese network and a radiomic-based support vector machine (SVM) classifier. The 2D-based Siamese network contains a pair of parallel feature extractors with shared weights followed by a single classifier. This architecture is designed to identify the inter-class difference. On the other hand, the SVM model takes the radiomic features extracted from 3D segmentation volumes as the input for twofold classification, either a false-positive segmentation or a true BM. Lastly, the outputs from both models create an ensemble to generate the final label. The performance of the proposed model in the segmented mBMs testing dataset reached the accuracy (ACC), sensitivity (SEN), specificity (SPE) and area under the curve of 0.91, 0.96, 0.90 and 0.93, respectively. After integrating the proposed model into the original segmentation platform, the average segmentation false negative rate (FNR) and the false positive over the union (FPoU) were 0.13 and 0.09, respectively, which preserved the initial FNR (0.07) and significantly improved the FPoU (0.55). The proposed method effectively reduced the false-positive rate in the BMs raw segmentations indicating that the integration of the proposed ensemble classifier into the BMs segmentation platform provides a beneficial tool for mBMs SRS management.