Matthew L. Johnston
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Matthew L. Johnston has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Soumya Bose
School of Electrical Engineering and Computer Science, Oregon State University, Corvallis, OR, USA
9 shared publications - Boyu Shen
School of Electrical Engineering and Computer Science, Oregon State University, Corvallis, OR, USA
7 shared publications - Shaan Sengupta
School of Electrical Engineering and Computer Science, Oregon State University, Corvallis, OR, USA
6 shared publications - Jaehyeong Park
School of Electrical Engineering and Computer Science, Oregon State University, Corvallis, OR, USA
5 shared publications - Siyuan Yu
School of Electrical Engineering and Computer Science, Oregon State University, Corvallis, OR, USA
5 shared publications - Callen Votzke
Collaborative Robotics and Intelligent Systems (CoRIS) Institute, Oregon State University, Corvallis, OR, USA
4 shared publications
Latest Publications
- 13 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (19) , 36930-36939
Shape Reconstruction Using Soft, Stretchable Sensors With Embedded Strain Sensors and Inertial Measurement Units
In this paper, we present a custom soft sensor for performing shape reconstruction of continuum structures. One major drawback of camera-based motion capture systems is the need for a structured, instrumented environment. Outside of these curated spaces there are many applications that would benefit from having a general-purpose, camera-less sensing solution for proprioception. Our approach is a sensor that performs self-shape reconstruction with no need for external data collection, structured environments, or model training. The sensor body is made of soft silicone and embeds a series of custom PCBs with 9-axis IMUs and liquid metal strain sensors spanning between them and supports up to 100 Hz sample rate for all sensors. We use spherical interpolation with the strain and IMU orientation measurements to sequentially reconstruct the sensor geometry along the chain of segments. We validated the sensor design and accompanying reconstruction technique with dynamic bending experiments on a custom, motorized testbed. Using optical motion tracking to ground truth the reconstruction estimates, the average Euclidean distance errors over the body of the 325mm long, 5-node sensor ranged from 5.07mm to 9.38mm. Additional cycle testing demonstrated that the sensor behaved consistently over longer duration, with low deviations in estimated positions when moved through the same positions.
- 13 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (19) , 36930-36939
Shape Reconstruction Using Soft, Stretchable Sensors With Embedded Strain Sensors and Inertial Measurement Units
In this paper, we present a custom soft sensor for performing shape reconstruction of continuum structures. One major drawback of camera-based motion capture systems is the need for a structured, instrumented environment. Outside of these curated spaces there are many applications that would benefit from having a general-purpose, camera-less sensing solution for proprioception. Our approach is a sensor that performs self-shape reconstruction with no need for external data collection, structured environments, or model training. The sensor body is made of soft silicone and embeds a series of custom PCBs with 9-axis IMUs and liquid metal strain sensors spanning between them and supports up to 100 Hz sample rate for all sensors. We use spherical interpolation with the strain and IMU orientation measurements to sequentially reconstruct the sensor geometry along the chain of segments. We validated the sensor design and accompanying reconstruction technique with dynamic bending experiments on a custom, motorized testbed. Using optical motion tracking to ground truth the reconstruction estimates, the average Euclidean distance errors over the body of the 325mm long, 5-node sensor ranged from 5.07mm to 9.38mm. Additional cycle testing demonstrated that the sensor behaved consistently over longer duration, with low deviations in estimated positions when moved through the same positions.
- 21 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 72 (12) , 1857-1861
Thermal Inkjet Pumping and Flow Rate Estimation for Microfluidics in Lab-on-CMOS Packages
In this work, we present the use of a thermal inkjet (TIJ) die as an active micropump for lab-on-CMOS applications, with the goal of replacing off-chip syringe pumps with in-package fluidic control. A combination of wafer-level molding and 3D-printing is used to co-locate a TIJ integrated circuit (IC) pump with package-level microfluidics and electrodes for impedance sensing in a single planar package. The TIJ IC acts as a pull-pump, ejecting waste solution and pulling new solution across a set of gold electrodes on the package surface; flow rate is controlled directly by the TIJ firing rate. These electrodes can be used to measure impedance, such as for electrical cell counting, and we further characterize the ability to electrically estimate volumetric flow rate from transient signals and known geometry. To demonstrate, impedance measurements of 3, 4.5, and 6 μm polystyrene beads in solution were performed at droplet ejection rates ranging from 63-500 Hz, and an adjustable flow rate of 29.4 pl/s/Hz is shown, estimated using both electrical and optical tracking methods. Long-term, this approach can provide integrated pumping, adjustable flow rate control, and integrated flow rate measurement for multi-chip lab-on-CMOS systems.
- 21 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 72 (12) , 1857-1861
Thermal Inkjet Pumping and Flow Rate Estimation for Microfluidics in Lab-on-CMOS Packages
In this work, we present the use of a thermal inkjet (TIJ) die as an active micropump for lab-on-CMOS applications, with the goal of replacing off-chip syringe pumps with in-package fluidic control. A combination of wafer-level molding and 3D-printing is used to co-locate a TIJ integrated circuit (IC) pump with package-level microfluidics and electrodes for impedance sensing in a single planar package. The TIJ IC acts as a pull-pump, ejecting waste solution and pulling new solution across a set of gold electrodes on the package surface; flow rate is controlled directly by the TIJ firing rate. These electrodes can be used to measure impedance, such as for electrical cell counting, and we further characterize the ability to electrically estimate volumetric flow rate from transient signals and known geometry. To demonstrate, impedance measurements of 3, 4.5, and 6 μm polystyrene beads in solution were performed at droplet ejection rates ranging from 63-500 Hz, and an adjustable flow rate of 29.4 pl/s/Hz is shown, estimated using both electrical and optical tracking methods. Long-term, this approach can provide integrated pumping, adjustable flow rate control, and integrated flow rate measurement for multi-chip lab-on-CMOS systems.
- 1 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 20 (1) , 15-27
A Differential Impedance Flow Cytometry Front-End With Baseline Current Cancellation
In this work, we present a high-performance analog front-end (AFE) circuit for impedance-based flow cytometry readout. The AFE is designed to interface to a three-electrode sensor topology using center electrode excitation and differential current output. To satisfy the needs of a differential high gain signal path, we propose a digitally tunable and calibrated cancellation current generation path to remove the baseline current injected into the transimpedance amplifier (TIA) stages. This prevents TIA saturation and allows for higher gain. Consequently, the AFE is more power efficient while maintaining better noise and interference rejection. The proposed circuit is designed and fabricated in a 180 nm CMOS process. It covers an excitation frequency range of 0.5 MHz to 10 MHz and consumes 15.6 mW during nominal operation. Digital calibration is implemented using an off-chip ADC and automated calibration algorithm. Measurement results show that at 1 MHz excitation, the AFE achieves 1.7 pA/$\sqrt{\text{Hz}}$ input-referred current noise density with floating inputs. The AFE achieves detection of 3 um diameter particles in a microfluidic flow cell, demonstrating its performance and practicality for impedance flow cytometry.
- 1 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 20 (1) , 15-27
A Differential Impedance Flow Cytometry Front-End With Baseline Current Cancellation
In this work, we present a high-performance analog front-end (AFE) circuit for impedance-based flow cytometry readout. The AFE is designed to interface to a three-electrode sensor topology using center electrode excitation and differential current output. To satisfy the needs of a differential high gain signal path, we propose a digitally tunable and calibrated cancellation current generation path to remove the baseline current injected into the transimpedance amplifier (TIA) stages. This prevents TIA saturation and allows for higher gain. Consequently, the AFE is more power efficient while maintaining better noise and interference rejection. The proposed circuit is designed and fabricated in a 180 nm CMOS process. It covers an excitation frequency range of 0.5 MHz to 10 MHz and consumes 15.6 mW during nominal operation. Digital calibration is implemented using an off-chip ADC and automated calibration algorithm. Measurement results show that at 1 MHz excitation, the AFE achieves 1.7 pA/$\sqrt{\text{Hz}}$ input-referred current noise density with floating inputs. The AFE achieves detection of 3 um diameter particles in a microfluidic flow cell, demonstrating its performance and practicality for impedance flow cytometry.
- 4 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (4) , 712-725
System-on-Chip for Flow Cytometry With Impedance Measurement and Integrated Real-Time Size Classification
This paper presents an impedance measurement system-on-chip (SoC) for flow cytometry (i.e. cell counting) applications. A source-differential, three-electrode sensing scheme is used in a microfluidic flow cell for particle detection. At the front-end, a lock-in amplifier architecture is used, including a high-gain TIA with 60MHz bandwidth, passive mixers, and lowpass filters. The ac sensor signal is demodulated to extract inphase (I) and quadrature (Q) baseband components to measure complex impedance. At the back-end, the SoC includes an 8-bit level-crossing ADC (LCADC) for digitizing I/Q signals, followed by real-time digital feature extraction and linear classification for real-time cell size determination. The SoC was fabricated in a 180nm CMOS process. A measured prototype IC achieves 733 fA/$\sqrt {Hz}$ noise floor and 23 pArms input-referred noise from 1-1 kHz. Combined with a microfludic flow cell, polymer beads in solution were used as cell surrogates to demonstrate particle counting. Measured results for particle diameters of 10 μm, 6 μm, 4.5 μm and 3 μm are shown. Following offline training, the SoC demonstrated on-chip classification of 4.5 μm and 6 μm beads with a prediction accuracy of 86.16% with pre-recorded data, and 73.6% while performing real-time inline classification.
- 4 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (4) , 712-725
System-on-Chip for Flow Cytometry With Impedance Measurement and Integrated Real-Time Size Classification
This paper presents an impedance measurement system-on-chip (SoC) for flow cytometry (i.e. cell counting) applications. A source-differential, three-electrode sensing scheme is used in a microfluidic flow cell for particle detection. At the front-end, a lock-in amplifier architecture is used, including a high-gain TIA with 60MHz bandwidth, passive mixers, and lowpass filters. The ac sensor signal is demodulated to extract inphase (I) and quadrature (Q) baseband components to measure complex impedance. At the back-end, the SoC includes an 8-bit level-crossing ADC (LCADC) for digitizing I/Q signals, followed by real-time digital feature extraction and linear classification for real-time cell size determination. The SoC was fabricated in a 180nm CMOS process. A measured prototype IC achieves 733 fA/$\sqrt {Hz}$ noise floor and 23 pArms input-referred noise from 1-1 kHz. Combined with a microfludic flow cell, polymer beads in solution were used as cell surrogates to demonstrate particle counting. Measured results for particle diameters of 10 μm, 6 μm, 4.5 μm and 3 μm are shown. Following offline training, the SoC demonstrated on-chip classification of 4.5 μm and 6 μm beads with a prediction accuracy of 86.16% with pre-recorded data, and 73.6% while performing real-time inline classification.
- 27 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (4) , 821-833
Microfluidic Lab-on-CMOS Packaging Using Wafer-Level Molding and 3D-Printed Interconnects
Lab-on-a-chip (LoC) technologies continue to promise lower cost and more accessible platforms for performing biomedical testing in low-cost and disposable form factors. Lab-on-CMOS or lab-on-microchip methods extend this paradigm by merging passive LoC systems with active complementary metal-oxide semiconductor (CMOS) integrated circuits (IC) to enable front-end signal conditioning and digitization immediately next to sensors in fluid channels. However, integrating ICs with microfluidics remains a challenge due to size mismatch and geometric constraints, such as non-planar wirebonds or flip-chip approaches in conflict with planar microfluidics. In this work, we present a hybrid packaging solution for IC-enabled microfluidic sensor systems. Our approach uses a combination of wafer-level molding and direct-write 3D printed interconnects, which are compatible with post-fabrication of planar dielectric and microfluidic layers. In addition, high-resolution direct-write printing can be used to rapidly fabricate electrical interconnects at a scale compatible with IC packaging without the need for fixed tooling. Two demonstration sensor-in-package systems with integrated microfluidics are shown, including measurement of electrical impedance and optical scattering to detect and size particles flowing through microfluidic channels over or adjacent to CMOS sensor and read-out ICs. The approach enables fabrication of impedance measurement electrodes less than 1mm from the readout IC, directly on package surface. As shown, direct fluid contact with the IC surface is prevented by passivation, but long-term this approach can also enable fluid access to IC-integrated electrodes or other top-level IC features, making it broadly enabling for lab-on-CMOS applications.
- 27 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (4) , 821-833
Microfluidic Lab-on-CMOS Packaging Using Wafer-Level Molding and 3D-Printed Interconnects
Lab-on-a-chip (LoC) technologies continue to promise lower cost and more accessible platforms for performing biomedical testing in low-cost and disposable form factors. Lab-on-CMOS or lab-on-microchip methods extend this paradigm by merging passive LoC systems with active complementary metal-oxide semiconductor (CMOS) integrated circuits (IC) to enable front-end signal conditioning and digitization immediately next to sensors in fluid channels. However, integrating ICs with microfluidics remains a challenge due to size mismatch and geometric constraints, such as non-planar wirebonds or flip-chip approaches in conflict with planar microfluidics. In this work, we present a hybrid packaging solution for IC-enabled microfluidic sensor systems. Our approach uses a combination of wafer-level molding and direct-write 3D printed interconnects, which are compatible with post-fabrication of planar dielectric and microfluidic layers. In addition, high-resolution direct-write printing can be used to rapidly fabricate electrical interconnects at a scale compatible with IC packaging without the need for fixed tooling. Two demonstration sensor-in-package systems with integrated microfluidics are shown, including measurement of electrical impedance and optical scattering to detect and size particles flowing through microfluidic channels over or adjacent to CMOS sensor and read-out ICs. The approach enables fabrication of impedance measurement electrodes less than 1mm from the readout IC, directly on package surface. As shown, direct fluid contact with the IC surface is prevented by passivation, but long-term this approach can also enable fluid access to IC-integrated electrodes or other top-level IC features, making it broadly enabling for lab-on-CMOS applications.
- 27 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 71 (12) , 4799-4803
A 99.1-dB SFDR, 87.1-dB SNDR, 50-kS/s 3rd-Order Continuous-Time Incremental ADC With Current-Controlled-Oscillator Quantizer
This paper presents a 3rd-order continuous-time (CT) incremental ADC that uses a pseudo-differential current-controlled-oscillator quantizer (CCOQ). The approach combines the complementary aspects of CCO-based quantization and incremental ADC operation. The CCOQ, used as a frequency quantizer, improves the efficiency of high-order incremental operation as it provides multi-bit quantization, intrinsic dynamic element matching, and an additional order of residual accumulation. At the same time, the CCOQ conveniently does not require reset in the analog domain, thus simplifying oscillator design. A prototype IC was fabricated in 180 nm CMOS process. Clocked at 3.2 MHz with a Nyquist sampling rate of 50 kHz, based on measurements it achieves 87.1 dB SNDR, 99.1 dB SFDR, and 89.7 dB DR and consumes 204 μ W at 1.4 V supply. This results in a competitive 168 dB SNDR-based Schreier FoM, and it demonstrates the potential for leveraging CCOQ benefits within an IADC topology.
- 27 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 71 (12) , 4799-4803
A 99.1-dB SFDR, 87.1-dB SNDR, 50-kS/s 3rd-Order Continuous-Time Incremental ADC With Current-Controlled-Oscillator Quantizer
This paper presents a 3rd-order continuous-time (CT) incremental ADC that uses a pseudo-differential current-controlled-oscillator quantizer (CCOQ). The approach combines the complementary aspects of CCO-based quantization and incremental ADC operation. The CCOQ, used as a frequency quantizer, improves the efficiency of high-order incremental operation as it provides multi-bit quantization, intrinsic dynamic element matching, and an additional order of residual accumulation. At the same time, the CCOQ conveniently does not require reset in the analog domain, thus simplifying oscillator design. A prototype IC was fabricated in 180 nm CMOS process. Clocked at 3.2 MHz with a Nyquist sampling rate of 50 kHz, based on measurements it achieves 87.1 dB SNDR, 99.1 dB SFDR, and 89.7 dB DR and consumes 204 μ W at 1.4 V supply. This results in a competitive 168 dB SNDR-based Schreier FoM, and it demonstrates the potential for leveraging CCOQ benefits within an IADC topology.
- 26 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 71 (12) , 4794-4798
A Sub-0.1% THD Sinusoidal-Signal Generator for Impedance Measurement Using a Delta-Sigma-Modulated Look-Up Table
Many frequency-based electronic measurement applications require a sinusoidal stimulus with high linearity, such for accurate impedance measurement systems used in chemistry, biology, and physical sensing. In this work, we present a highly linear sinusoidal-signal generator (SSG) on chip for use in such impedance measurement systems. Building upon prior digital SSG approaches that use a digital multi-stage noise-shaping (MASH) modulator to achieve high linearity while using a small digital-to-analog converter (DAC), we introduce delta-sigma modulation directly to the look-up table, achieving similarly high linearity without requiring a MASH modulator in the signal chain, which adds both design complexity and in-band errors. A prototype integrated circuit was fabricated using 180 nm CMOS and measured while generating a 20 kHz, 140 mVpp sine wave. It achieves 0.088% THD through the 20th harmonic and 63.5 dB SFDR. The approach is highly digital in nature and therefore amenable to implementation using automated synthesis and place and route, which makes it a promising approach for future scalability in advanced CMOS process nodes.
- 26 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 71 (12) , 4794-4798
A Sub-0.1% THD Sinusoidal-Signal Generator for Impedance Measurement Using a Delta-Sigma-Modulated Look-Up Table
Many frequency-based electronic measurement applications require a sinusoidal stimulus with high linearity, such for accurate impedance measurement systems used in chemistry, biology, and physical sensing. In this work, we present a highly linear sinusoidal-signal generator (SSG) on chip for use in such impedance measurement systems. Building upon prior digital SSG approaches that use a digital multi-stage noise-shaping (MASH) modulator to achieve high linearity while using a small digital-to-analog converter (DAC), we introduce delta-sigma modulation directly to the look-up table, achieving similarly high linearity without requiring a MASH modulator in the signal chain, which adds both design complexity and in-band errors. A prototype integrated circuit was fabricated using 180 nm CMOS and measured while generating a 20 kHz, 140 mVpp sine wave. It achieves 0.088% THD through the 20th harmonic and 63.5 dB SFDR. The approach is highly digital in nature and therefore amenable to implementation using automated synthesis and place and route, which makes it a promising approach for future scalability in advanced CMOS process nodes.
- 3 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 58 (12) , 3421-3432
A Highly Integrated Distributed Mixer Receiver for Low-Power Wireless Radios
Low-power receivers (RXs) with 100 $\mu$ W-scale power consumption can enable several power/energy-constrained Internet-of-Things (IoT) applications. However, achieving sensitivity, interferer tolerance, and wide operating range with low power presents a challenge for existing architectures, particularly those constrained to highly integrated solutions without high- Q off-chip components. This article presents a low-power RX that utilizes a novel distributed N -path mixer architecture to enable a sub-150- $\mu \text{W}$ multi-tone RX achieving wide operating range, high sensitivity and interferer tolerance. The proposed architecture is implemented in 22 nm CMOS and occupies 0.48 mm $^2$ . The RX achieves a 500-MHz operating range from 0.4 to 0.9 GHz with up to $-$ 85-dbm sensitivity for 100-kbps data rate with $<$ 150- $\mu$ W power consumption and up to $-$ 41-dB SIR tolerance.
- 3 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 58 (12) , 3421-3432
A Highly Integrated Distributed Mixer Receiver for Low-Power Wireless Radios
Low-power receivers (RXs) with 100 $\mu$ W-scale power consumption can enable several power/energy-constrained Internet-of-Things (IoT) applications. However, achieving sensitivity, interferer tolerance, and wide operating range with low power presents a challenge for existing architectures, particularly those constrained to highly integrated solutions without high- Q off-chip components. This article presents a low-power RX that utilizes a novel distributed N -path mixer architecture to enable a sub-150- $\mu \text{W}$ multi-tone RX achieving wide operating range, high sensitivity and interferer tolerance. The proposed architecture is implemented in 22 nm CMOS and occupies 0.48 mm $^2$ . The RX achieves a 500-MHz operating range from 0.4 to 0.9 GHz with up to $-$ 85-dbm sensitivity for 100-kbps data rate with $<$ 150- $\mu$ W power consumption and up to $-$ 41-dB SIR tolerance.
- Open Access
- 21 August 2023
- Published by MDPI AG in Chemosensors
- Vol. 11 (8) , 467
Progress on Electrochemical Sensing of Pharmaceutical Drugs in Complex Biofluids
Electrochemical detection, with its advantages of being rapid, multi-time point, compatible with cost-effective fabrication methods, and having the potential for miniaturization and portability, has great promise for point-of-care drug monitoring. However, a continuing challenge concerns the robust and sensitive electrochemical detection of pharmaceutical analytes from biological fluids. These complex matrices, such as saliva, sweat, interstitial fluid, urine, and blood/serum, contain multiple components that can contribute to an increased background or reduced analyte signal. In this mini-review, we discuss progress on electrochemical sensing in complex biofluids. We first introduce the challenge of drug titration in the management of various health conditions and provide an overview of the motivation for improved therapeutic drug monitoring, including current limitations. We then review progress on pharmaceutical drug detection from these biofluids with a focus on sample preprocessing, electrode modification for signal amplification, and/or electrode passivation to minimize fouling. Finally, we highlight promising strategies that have enabled robust drug quantification for clinical relevance and that may be useful for field-use systems.
- 21 August 2023
- Published by MDPI AG in Chemosensors
- Vol. 11 (8) , 467
Open AccessProgress on Electrochemical Sensing of Pharmaceutical Drugs in Complex Biofluids
Electrochemical detection, with its advantages of being rapid, multi-time point, compatible with cost-effective fabrication methods, and having the potential for miniaturization and portability, has great promise for point-of-care drug monitoring. However, a continuing challenge concerns the robust and sensitive electrochemical detection of pharmaceutical analytes from biological fluids. These complex matrices, such as saliva, sweat, interstitial fluid, urine, and blood/serum, contain multiple components that can contribute to an increased background or reduced analyte signal. In this mini-review, we discuss progress on electrochemical sensing in complex biofluids. We first introduce the challenge of drug titration in the management of various health conditions and provide an overview of the motivation for improved therapeutic drug monitoring, including current limitations. We then review progress on pharmaceutical drug detection from these biofluids with a focus on sample preprocessing, electrode modification for signal amplification, and/or electrode passivation to minimize fouling. Finally, we highlight promising strategies that have enabled robust drug quantification for clinical relevance and that may be useful for field-use systems.
- 22 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (4) , 768-781
A Reconfigurable Tri-Mode Frequency-Locked Loop Readout Circuit for Biosensor Interfaces
In this paper, a frequency-locked loop (FLL) based multimodal readout integrated circuit (IC) for interfacing with off-chip temperature, electrochemical, and pH sensors is presented. By reconfiguring its switched-capacitor feedback network, the readout circuit is able to measure resistance, current, and voltage without additional active analog front-end circuits. A prototype IC was fabricated in a 0.18 µm CMOS process. Measured results show that when measuring resistance, the input-referred resistance resolution is 10.5 $\Omega$ for 100 Hz integration bandwidth. Using an off-chip thermistor, the readout circuit covers a temperature range of 0–75 $^{\circ }$ C and achieves an equivalent temperature resolution of 16.4 mK rms . In current mode, the readout circuit has an input range of 0.5µA and an input-referred current noise as low as 40.6 pA rms for 100 Hz bandwidth. Interfacing with an on-chip potentiostat, glucose chronoamperometry is demonstrated. In voltage mode, a minimum input-referred voltage noise of 31.7 µV rms is achieved, and the IC can measure a pH range from 1.6 to 12 using a commercial pH probe. At a 1.2 V supply, power consumption of the readout circuit is below 10 µW for all three measurement modes. Additionally, the prototype IC includes an integrated wireless transmitter that implements on-off keying modulation, and a wireless multimodal sensing system utilizing the FLL-based readout circuit is demonstrated.
- 22 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (4) , 768-781
A Reconfigurable Tri-Mode Frequency-Locked Loop Readout Circuit for Biosensor Interfaces
In this paper, a frequency-locked loop (FLL) based multimodal readout integrated circuit (IC) for interfacing with off-chip temperature, electrochemical, and pH sensors is presented. By reconfiguring its switched-capacitor feedback network, the readout circuit is able to measure resistance, current, and voltage without additional active analog front-end circuits. A prototype IC was fabricated in a 0.18 µm CMOS process. Measured results show that when measuring resistance, the input-referred resistance resolution is 10.5 $\Omega$ for 100 Hz integration bandwidth. Using an off-chip thermistor, the readout circuit covers a temperature range of 0–75 $^{\circ }$ C and achieves an equivalent temperature resolution of 16.4 mK rms . In current mode, the readout circuit has an input range of 0.5µA and an input-referred current noise as low as 40.6 pA rms for 100 Hz bandwidth. Interfacing with an on-chip potentiostat, glucose chronoamperometry is demonstrated. In voltage mode, a minimum input-referred voltage noise of 31.7 µV rms is achieved, and the IC can measure a pH range from 1.6 to 12 using a commercial pH probe. At a 1.2 V supply, power consumption of the readout circuit is below 10 µW for all three measurement modes. Additionally, the prototype IC includes an integrated wireless transmitter that implements on-off keying modulation, and a wireless multimodal sensing system utilizing the FLL-based readout circuit is demonstrated.