JPJaehyeong Park

Jaehyeong Park

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jaehyeong Park has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • System-on-Chip for Flow Cytometry With Impedance Measurement and Integrated Real-Time Size Classification

    by Tzu-Hsuan Chou, Siyuan Yu, Calder Wilson, Jacob Dawes, Jaehyeong Park, Louis Marun, Matthew L. Johnston

    This paper presents an impedance measurement system-on-chip (SoC) for flow cytometry (i.e. cell counting) applications. A source-differential, three-electrode sensing scheme is used in a microfluidic flow cell for particle detection. At the front-end, a lock-in amplifier architecture is used, including a high-gain TIA with 60MHz bandwidth, passive mixers, and lowpass filters. The ac sensor signal is demodulated to extract inphase (I) and quadrature (Q) baseband components to measure complex impedance. At the back-end, the SoC includes an 8-bit level-crossing ADC (LCADC) for digitizing I/Q signals, followed by real-time digital feature extraction and linear classification for real-time cell size determination. The SoC was fabricated in a 180nm CMOS process. A measured prototype IC achieves 733 fA/$\sqrt {Hz}$ noise floor and 23 pArms input-referred noise from 1-1 kHz. Combined with a microfludic flow cell, polymer beads in solution were used as cell surrogates to demonstrate particle counting. Measured results for particle diameters of 10 μm, 6 μm, 4.5 μm and 3 μm are shown. Following offline training, the SoC demonstrated on-chip classification of 4.5 μm and 6 μm beads with a prediction accuracy of 86.16% with pre-recorded data, and 73.6% while performing real-time inline classification.


  • A Sub-0.1% THD Sinusoidal-Signal Generator for Impedance Measurement Using a Delta-Sigma-Modulated Look-Up Table

    by Jaehyeong Park, Matthew L. Johnston

    Many frequency-based electronic measurement applications require a sinusoidal stimulus with high linearity, such for accurate impedance measurement systems used in chemistry, biology, and physical sensing. In this work, we present a highly linear sinusoidal-signal generator (SSG) on chip for use in such impedance measurement systems. Building upon prior digital SSG approaches that use a digital multi-stage noise-shaping (MASH) modulator to achieve high linearity while using a small digital-to-analog converter (DAC), we introduce delta-sigma modulation directly to the look-up table, achieving similarly high linearity without requiring a MASH modulator in the signal chain, which adds both design complexity and in-band errors. A prototype integrated circuit was fabricated using 180 nm CMOS and measured while generating a 20 kHz, 140 mVpp sine wave. It achieves 0.088% THD through the 20th harmonic and 63.5 dB SFDR. The approach is highly digital in nature and therefore amenable to implementation using automated synthesis and place and route, which makes it a promising approach for future scalability in advanced CMOS process nodes.


  • A Reconfigurable Tri-Mode Frequency-Locked Loop Readout Circuit for Biosensor Interfaces

    by Siyuan Yu, Tzu-Hsuan Chou, Soumya Bose, Jacob Cook, Jaehyeong Park, Matthew L. Johnston

    In this paper, a frequency-locked loop (FLL) based multimodal readout integrated circuit (IC) for interfacing with off-chip temperature, electrochemical, and pH sensors is presented. By reconfiguring its switched-capacitor feedback network, the readout circuit is able to measure resistance, current, and voltage without additional active analog front-end circuits. A prototype IC was fabricated in a 0.18 µm CMOS process. Measured results show that when measuring resistance, the input-referred resistance resolution is 10.5 $\Omega$ for 100 Hz integration bandwidth. Using an off-chip thermistor, the readout circuit covers a temperature range of 0–75 $^{\circ }$ C and achieves an equivalent temperature resolution of 16.4 mK rms . In current mode, the readout circuit has an input range of 0.5µA and an input-referred current noise as low as 40.6 pA rms for 100 Hz bandwidth. Interfacing with an on-chip potentiostat, glucose chronoamperometry is demonstrated. In voltage mode, a minimum input-referred voltage noise of 31.7 µV rms is achieved, and the IC can measure a pH range from 1.6 to 12 using a commercial pH probe. At a 1.2 V supply, power consumption of the readout circuit is below 10 µW for all three measurement modes. Additionally, the prototype IC includes an integrated wireless transmitter that implements on-off keying modulation, and a wireless multimodal sensing system utilizing the FLL-based readout circuit is demonstrated.


  • Wireless, Multi-Sensor System-on-Chip for pH and Amperometry Powered by Body Heat

    by Tzu-Hsuan Chou, Siyuan Yu, Soumya Bose, Jacob Cook, Jaehyeong Park, Matthew L. Johnston

    This paper presents a body-heat-powered, multi-sensor SoC for measurement of chemical and biological sensors. Our approach combines analog front-end sensor interfaces for voltage- (V-to-I) and current-mode (potentiostat) sensors with a relaxation oscillator (RxO) readout scheme targeting $\ll$ 10 $\mu$ W power consumption. The design was implemented as a complete sensor readout system-on-chip, including a low-voltage energy harvester compatible with thermoelectric generation and a near-field wireless transmitter. A prototype IC was fabricated in a 0.18 $\mu$ m CMOS process as a proof-of-concept. As measured, full-range pH measurement consumes 2.2 $\mu$ W at maximum, where the RxO consumes 0.7 $\mu$ W and measured linearity of the readout circuit demonstrates R $^{2}$ $\gt $ 0.999. Glucose measurement is also demonstrated using an on-chip potentiostat circuit as the input of the RxO, with a readout power consumption as low as 1.4 $\mu$ W. As a final proof-of-principle, both pH and glucose measurement are demonstrated while powering from body heat using a centimeter-scale thermoelectric generator on the skin surface, and pH measurement is further demonstrated with an on-chip transmitter for wireless data transmission. Long-term, the presented approach may enable a variety of biological, electrochemical, and physical sensor readout schemes with microwatt operation for batteryless and power autonomous sensor systems.


  • A Sinusoidal Signal Generator Using a Delta-Sigma Modulated Look-Up Table and Analysis of Dither

    by Jaehyeong Park, Matthew L. Johnston

    Sinusoidal signal generators (SSG) are increasingly required for on-chip integration in impedance measurement architectures for bio-sensing and chemical sensing applications. For digital SSG architectures, there are inherent trade-offs among circuit area, power, and linearity. In this work, we present a new approach that encodes a delta-sigma-modulated look-up table (ΔΣM-LUT) to decrease digital circuit size and power while maintaining high linearity. In addition, we present a method for analyzing the combined periodicity of the modulator and the LUT for adding dither to further improve performance. The approach is demonstrated using a 5-bit, 2nd-order ΔΣM-LUT controlling a digital ΔΣ modulated SSG, where it enables a significant decrease in digital circuit area and power compared to state-of-the-art designs while achieving 64.6 dBc SFDR and 0.074% THD.