Quantifying Passive Biomechanical Stability Using an Industrial Robot: Development and Experimental Validation of a Task Space Motion Framework
Open Access
- 21 February 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 29397-29413
Abstract
This paper presents a methodology and generalized motion framework for quantifying passive biomechanical stability and Range of Motion of human cadaveric specimens, using a position-controlled industrial robot and a wrist-mounted force/torque sensor. Many biomechanical studies on diarthrodial joints using human cadaveric specimens are published in the literature, using various test protocols and machines to apply the loading conditions. In these studies, laxity or mobility of the joints are quantified by measuring the magnitude of translations and rotations with respect to force and torque. The protocols and anatomical motions of the specimens are usually described high-level, textually, and from a medical perspective to a broad audience. The present paper aims to describe, from a technical perspective to a robotics audience, our method to perform biomechanical studies and how existing protocols can be replicated through parameterization using the existing textual descriptions. To accomplish this, we propose a generalized task space motion framework for performing biomechanical studies on diarthrodial joints. The generalization is made by defining the Tool Center Point at the cadaveric joint rotation center and aligning the specimen so the anatomical motions can be modeled in world frame or tool frame. Our framework has the potential to rapidly automate new or existing protocols through parameterization, including protocols performed by machines other than industrial robots or serial manipulators. The framework was evaluated in a technical pilot study on the shoulder, using one cadaveric shoulder specimen and an established protocol. The specimen was tested in the intact state and in an injury state.Keywords
Funding Information
- Liaison Committee for Education, Research and Innovation in Central Norway (2019/38881)
- Norwegian University of Science and Technology
This publication has 33 references indexed in Scilit:
- The novel arthroscopic subscapular quadriceps tendon–bone sling procedure provides increased stability in shoulder cadavers with severe glenoid bone lossKnee Surgery, Sports Traumatology, Arthroscopy, 2020
- The 6‐O'clock Anchor Increases Labral Repair Strength in a Biomechanical Shoulder Instability ModelArthroscopy, 2019
- New parameters describing how knee ligaments carry force in situ predict interspecimen variations in laxity during simulated clinical examsJournal of Biomechanics, 2017
- Assessment of pose repeatability and specimen repositioning of a robotic joint testing platformMedical Engineering & Physics, 2017
- The effect of the arthroscopic augmentation of the subscapularis tendon on shoulder instability and range of motion: A biomechanical studyClinical Biomechanics, 2016
- Implant impingement during internal rotation after reverse shoulder arthroplasty. The effect of implant configuration and scapula anatomy: A biomechanical studyClinical Biomechanics, 2016
- Validation of a six degree-of-freedom robotic system for hip in vitro biomechanical testingJournal of Biomechanics, 2015
- Characterization of robotic system passive path repeatability during specimen removal and reinstallation for in vitro knee joint testingMedical Engineering & Physics, 2014
- Evaluation of a robot-assisted testing system for multisegmental spine specimensJournal of Biomechanics, 2012
- Metrics for 3D Rotations: Comparison and AnalysisJournal of Mathematical Imaging and Vision, 2009