PSPeter Speier

Peter Speier

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Peter Speier has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Positive susceptibility‐based contrast imaging with dephased balanced steady‐state free precession

    by Jonas Frederik Faust, Peter Speier, Axel Joachim Krafft, Sunil Patil, Ravi Teja Seethamraju, Mark E. Ladd, Florian Maier

    Purpose: Dephasing gradients can be introduced within a variety of gradient‐echo pulse sequences to delineate local susceptibility changes (“White‐Marker” phenomenon), e.g., for the visualization of metallic interventional devices which are otherwise difficult to display. We investigated dephased balanced steady‐state free precession (d‐bSSFP) and compared it with similar contrast techniques: dephased RF‐spoiled fast low‐angle shot (d‐FLASH) and dephased steady‐state free precession (d‐SSFP). Methods: A signal model was formulated to describe the positive contrast in d‐bSSFP. For the example of an MR‐compatible aspiration needle, the positive contrast artifact appearance was theoretically derived, and the model was verified in a water phantom at B 0 = 0.55 T. Model accuracy was evaluated by comparing the measured artifact size (for TEs between 3.4 ms and 50 ms) and the signal magnitude to the model prediction. Results: While positive contrast artifacts for d‐FLASH and d‐SSFP are axisymmetric with respect to the generating object, for d‐bSSFP, a point‐symmetric susceptibility artifact arises for a cylindrical needle due to the characteristic signal formation. The observed d‐bSSFP artifact size was in accordance with the model (error < 1 mm). Measured (predicted) cumulated artifact signal was 1.13 ± 0.07 (1.27) times higher and 5.9 ± 0.4 times higher than the d‐SSFP and d‐FLASH cumulated artifact signal, respectively. In contrast to d‐SSFP, the d‐bSSFP artifact was robust against banding artifacts. Conclusion: d‐bSSFP contrast is well described by the introduced model. Positive contrast artifacts show higher cumulated signal magnitude, symmetry, and homogeneity compared with d‐FLASH and d‐SSFP and can therefore improve device visualization and potentially device localization.

  • Open Access

    Ultra-wide band radar for prospective respiratory motion correction in the liver

    by Tom Neumann, Juliane Ludwig, Kirsten M. Kerkering, Peter Speier, Frank Seifert, Tobias Schaeffter, Christoph Kolbitsch

    Objective. T1 mapping of the liver is time consuming and can be challenging due to respiratory motion. Here we present a prospective slice tracking approach, which utilizes an external ultra-wide band radar signal and allows for efficient T1 mapping during free-breathing. Approach. The fast radar signal is calibrated to an MR-based motion signal to create a motion model. This motion model provides motion estimates, which are used to carry out slice tracking for any subsequent clinical scan. This approach was evaluated in simulations, phantom experiments and in vivo scans. Main results. Radar-based slice tracking was implemented on an MR system with a total latency of 77 ms. Moving phantom experiments showed accurate motion prediction with an error of 0.12 mm in anterior-posterior and 0.81 mm in head-feet direction. The model error remained stable for up to two hours. In vivo experiments showed visible image improvement with a motion model error three times smaller than with a respiratory bellow. For T1 mapping during free-breathing the proposed approach provided similar results compared to reference T1 mapping during a breathhold. Significance. The proposed radar-based approach achieves accurate slice tracking and enables efficient T1 mapping of the liver during free-breathing. This motion correction approach is independent from scanning parameters and could also be used for applications like MR guided radiotherapy or MR Elastography.


  • Open Access

    Pilot tone-based prospective correction of respiratory motion for free-breathing myocardial T1 mapping

    by Juliane Ludwig, Kirsten Miriam Kerkering, Peter Speier, Tobias Schaeffter, Christoph Kolbitsch

    Objective: To provide respiratory motion correction for free-breathing myocardial T1 mapping using a pilot tone (PT) and a continuous golden-angle radial acquisition.Materials and methods: During a 45 s prescan the PT is acquired together with a dynamic sagittal image covering multiple respiratory cycles. From these images, the respiratory heart motion in head-feet and anterior–posterior direction is estimated and two linear models are derived between the PT and heart motion. In the following scan through-plane motion is corrected prospectively with slice tracking based on the PT. In-plane motion is corrected for retrospectively. Our method was evaluated on a motion phantom and 11 healthy subjects.Results: Non-motion corrected measurements using a moving phantom showed T1 errors of 14 ± 4% (p < 0.05) compared to a reference measurement. The proposed motion correction approach reduced this error to 3 ± 4% (p < 0.05). In vivo the respiratory motion led to an overestimation of T1 values by 26 ± 31% compared to breathhold T1 maps, which was successfully corrected to an average difference of 3 ± 2% (p < 0.05) between our free-breathing approach and breathhold data.Discussion: Our proposed PT-based motion correction approach allows for T1 mapping during free-breathing with the same accuracy as a corresponding breathhold T1 mapping scan.


  • Open Access

    Simultaneous multislice steady‐state free precession myocardial perfusion with full left ventricular coverage and high resolution at 1.5 T

    by Sarah McElroy, Giulio Ferrazzi, Muhummad Sohaib Nazir, Carl Evans, Joana Ferreira, Filippo Bosio, Nabila Mughal, Karl P. Kunze, Radhouene Neji, Peter Speier, et al.

    Purpose: To implement and evaluate a simultaneous multi‐slice balanced SSFP (SMS‐bSSFP) perfusion sequence and compressed sensing reconstruction for cardiac MR perfusion imaging with full left ventricular (LV) coverage (nine slices/heartbeat) and high spatial resolution (1.4 × 1.4 mm2) at 1.5T.Methods: A preliminary study was performed to evaluate the performance of blipped controlled aliasing in parallel imaging (CAIPI) and RF‐CAIPI with gradient‐controlled local Larmor adjustment (GC‐LOLA) in the presence of fat. A nine‐slice SMS‐bSSFP sequence using RF‐CAIPI with GC‐LOLA with high spatial resolution (1.4 × 1.4 mm2) and a conventional three‐slice sequence with conventional spatial resolution (1.9 × 1.9 mm2) were then acquired in 10 patients under rest conditions. Qualitative assessment was performed to assess image quality and perceived signal‐to‐noise ratio (SNR) on a 4‐point scale (0: poor image quality/low SNR; 3: excellent image quality/high SNR), and the number of myocardial segments with diagnostic image quality was recorded. Quantitative measurements of myocardial sharpness and upslope index were performed.Results: Fat signal leakage was significantly higher for blipped CAIPI than for RF‐CAIPI with GC‐LOLA (7.9% vs. 1.2%, p = 0.010). All 10 SMS‐bSSFP perfusion datasets resulted in 16/16 diagnostic myocardial segments. There were no significant differences between the SMS and conventional acquisitions in terms of image quality (2.6 ± 0.6 vs. 2.7 ± 0.2, p = 0.8) or perceived SNR (2.8 ± 0.3 vs. 2.7 ± 0.3, p = 0.3). Inter‐reader variability was good for both image quality (ICC = 0.84) and perceived SNR (ICC = 0.70). Myocardial sharpness was improved using the SMS sequence compared to the conventional sequence (0.37 ± 0.08 vs 0.32 ± 0.05, p < 0.001). There was no significant difference between measurements of upslope index for the SMS and conventional sequences (0.11 ± 0.04 vs. 0.11 ± 0.03, p = 0.84).Conclusion: SMS‐bSSFP with multiband factor 3 and compressed sensing reconstruction enables cardiac MR perfusion imaging with three‐fold increased spatial coverage and improved myocardial sharpness compared to a conventional sequence, without compromising perceived SNR, image quality, upslope index or number of diagnostic segments.


  • Open Access

    Pilot tone navigation for respiratory and cardiac motion‐resolved free‐running 5D flow MRI

    by Mariana B. L. Falcão, Lorenzo Di Sopra, Liliana Ma, Mario Bacher, Jérôme Yerly, Peter Speier, Tobias Rutz, Milan Prša, Michael Markl, Matthias Stuber, et al.

    Purpose: In this work, we integrated the pilot tone (PT) navigation system into a reconstruction framework for respiratory and cardiac motion‐resolved 5D flow. We tested the hypotheses that PT would provide equivalent respiratory curves, cardiac triggers, and corresponding flow measurements to a previously established self‐gating (SG) technique while being independent from changes to the acquisition parameters.Methods: Fifteen volunteers and 9 patients were scanned with a free‐running 5D flow sequence, with PT integrated. Respiratory curves and cardiac triggers from PT and SG were compared across all subjects. Flow measurements from 5D flow reconstructions using both PT and SG were compared to each other and to a reference electrocardiogram‐gated and respiratory triggered 4D flow acquisition. Radial trajectories with variable readouts per interleave were also tested in 1 subject to compare cardiac trigger quality between PT and SG.Results: The correlation between PT and SG respiratory curves were 0.95 ± 0.06 for volunteers and 0.95 ± 0.04 for patients. Heartbeat duration measurements in volunteers and patients showed a bias to electrocardiogram measurements of, respectively, 0.16 ± 64.94 ms and 0.01 ± 39.29 ms for PT versus electrocardiogram and of 0.24 ± 63.68 ms and 0.09 ± 32.79 ms for SG versus electrocardiogram. No significant differences were reported for the flow measurements between 5D flow PT and from 5D flow SG. A decrease in the cardiac triggering quality of SG was observed for increasing readouts per interleave, whereas PT quality remained constant.Conclusion: PT has been successfully integrated in 5D flow MRI and has shown equivalent results to the previously described 5D flow SG technique, while being completely acquisition‐independent.


  • Open Access

    All‐systolic first‐pass myocardial rest perfusion at a long saturation time using simultaneous multi‐slice imaging and compressed sensing acceleration

    by Giulio Ferrazzi, Sarah McElroy, Radhouene Neji, Karl P. Kunze, Muhummad Sohaib Nazir, Peter Speier, Daniel Stäb, Christoph Forman, Reza Razavi, Amedeo Chiribiri, et al.

    Purpose: To enable all‐systolic first‐pass rest myocardial perfusion with long saturation times. To investigate the change in perfusion contrast and dark rim artefacts through simulations and surrogate measurements.Methods: Simulations were employed to investigate optimal saturation time for myocardium‐perfusion defect contrast and blood‐to‐myocardium signal ratios. Two saturation recovery blocks with long/short saturation times (LTS/STS) were employed to image 3 slices at end‐systole and diastole. Simultaneous multi‐slice balanced steady state free precession imaging and compressed sensing acceleration were combined. The sequence was compared to a 3 slice‐by‐slice clinical protocol in 10 patients. Quantitative assessment of myocardium‐peak pre contrast and blood‐to‐myocardium signal ratios, as well as qualitative assessment of perceived SNR, image quality, blurring, and dark rim artefacts, were performed.Results: Simulations showed that with a bolus of 0.075 mmol/kg, a LTS of 240‐470 ms led to a relative increase in myocardium‐perfusion defect contrast of 34% ± 9%‐28% ± 27% than a STS = 120 ms, while reducing blood‐to‐myocardium signal ratio by 18% ± 10%‐32% ± 14% at peak myocardium. With a bolus of 0.05 mmol/kg, LTS was 320‐570 ms with an increase in myocardium‐perfusion defect contrast of 63% ± 13%‐62% ± 29%. Across patients, LTS led to an average increase in myocardium‐peak pre contrast of 59% (P < .001) at peak myocardium and a lower blood‐to‐myocardium signal ratio of 47% (P < .001) and 15% (P < .001) at peak blood/myocardium. LTS had improved motion robustness (P = .002), image quality (P < .001), and decreased dark rim artefacts (P = .008) than the clinical protocol.Conclusion: All‐systolic rest perfusion can be achieved by combining simultaneous multi‐slice and compressed sensing acceleration, enabling 3‐slice cardiac coverage with reduced motion and dark rim artefacts. Numerical simulations indicate that myocardium‐perfusion defect contrast increases at LTS.


  • Open Access

    Combined simultaneous multislice bSSFP and compressed sensing for first‐pass myocardial perfusion at 1.5 T with high spatial resolution and coverage

    by Sarah McElroy, Giulio Ferrazzi, Muhummad Sohaib Nazir, Karl P. Kunze, Radhouene Neji, Peter Speier, Daniel Stäb, Christoph Forman, Reza Razavi, Amedeo Chiribiri, et al.

    Purpose: To implement and evaluate a pseudorandom undersampling scheme for combined simultaneous multislice (SMS) balanced SSFP (bSSFP) and compressed‐sensing (CS) reconstruction to enable myocardial perfusion imaging with high spatial resolution and coverage at 1.5 T.Methods: A prospective pseudorandom undersampling scheme that is compatible with SMS‐bSSFP phase‐cycling requirements and CS was developed. The SMS‐bSSFP CS with pseudorandom and linear undersampling schemes were compared in a phantom. A high‐resolution (1.4 × 1.4 mm2) six‐slice SMS‐bSSFP CS perfusion sequence was compared with a conventional (1.9 × 1.9 mm2) three‐slice sequence in 10 patients. Qualitative assessment of image quality, perceived SNR, and number of diagnostic segments and quantitative measurements of sharpness, upslope index, and contrast ratio were performed.Results: In phantom experiments, pseudorandom undersampling resulted in residual artifact (RMS error) reduction by a factor of 7 compared with linear undersampling. In vivo, the proposed sequence demonstrated higher perceived SNR (2.9 ± 0.3 vs. 2.2 ± 0.6, P = .04), improved sharpness (0.35 ± 0.03 vs. 0.32 ± 0.05, P = .01), and a higher number of diagnostic segments (100% vs. 94%, P = .03) compared with the conventional sequence. There were no significant differences between the sequences in terms of image quality (2.5 ± 0.4 vs. 2.8 ± 0.2, P = .08), upslope index (0.11 ± 0.02 vs. 0.10 ± 0.01, P = .3), or contrast ratio (3.28 ± 0.35 vs. 3.36 ± 0.43, P = .7).Conclusion: A pseudorandom k‐space undersampling compatible with SMS‐bSSFP and CS reconstruction has been developed and enables cardiac MR perfusion imaging with increased spatial resolution and myocardial coverage, increased number of diagnostic segments and perceived SNR, and no difference in image quality, upslope index, and contrast ratio.


  • Open Access

    Clinical Evaluation of Highly Accelerated Compressed Sensing Time-of-Flight MR Angiography for Intracranial Arterial Stenosis

    by S.S. Lu, M. Qi, X. Zhang, X.H. Mu, M. Schmidt, Y. Sun, C. Forman, P. Speier, X.N. Hong

    BACKGROUND AND PURPOSE: Time-of-flight MR angiography is the preferred imaging technique to assess intracranial arterial stenosis but is limited by a relatively long acquisition time. Compressed sensing provides an innovative approach in undersampling k-space to minimize the data-acquisition time. We aimed to evaluate the diagnostic accuracy of compressed sensing TOF for detecting intracranial arterial stenosis by comparison with conventional parallel imaging TOF-MRA. MATERIALS AND METHODS: Compressed sensing TOF and parallel imaging TOF were performed in 22 patients with intracranial arterial stenosis. The MRA scan times were 2 minutes and 31 seconds and 4 minutes and 48 seconds for compressed sensing TOF and parallel imaging TOF, respectively. The reconstructed resolutions were 0.4 × 0.4 × 0.4 and 0.4 × 0.4 × 0.6 mm3 for compressed sensing TOF and parallel imaging TOF, respectively. The diagnostic quality of the images and visibility of the stenoses were independently ranked by 2 neuroradiologists blinded to the type of method and were compared using the Wilcoxon signed rank test. Concordance was calculated with the Cohen κ. Edge sharpness of the arteries and the luminal stenosis ratio were analyzed and compared using a paired-sample t test. RESULTS: The interrater agreement was good to excellent. Compressed sensing TOF resulted in image quality comparable with that of parallel imaging TOF but boosted confidence in diagnosing arterial stenoses (P = .025). The edge sharpness of the intracranial arteries for compressed sensing TOF was significantly higher than that for parallel imaging TOF (P < .001). The luminal stenosis ratio on compressed sensing TOF showed no significant difference compared with that on parallel imaging TOF. CONCLUSIONS: Compressed sensing TOF both remarkably reduced the scan time and provided adequate image quality for the diagnosis of intracranial arterial stenosis.


  • Gradient‐controlled local Larmor adjustment (GC‐LOLA) for simultaneous multislice bSSFP imaging with improved banding behavior

    by Daniel Stäb, Peter Speier

    Purpose: Simultaneous multislice (SMS) accelerated balanced SSFP (bSSFP) imaging can be impaired by off‐resonance effects, due to slice‐specific alterations in the frequency response. In this work, we introduce gradient‐controlled local Larmor adjustment as a means to restore the frequency response and to stabilize SMS‐accelerated bSSFP imaging with respect to banding artifacts.Methods: Providing each simultaneously excited slice with an individual RF phase cycle in SMS‐accelerated bSSFP imaging results in the sequence's frequency response being shifted slice‐specifically along the off‐resonance axis. The net available pass‐band for imaging is effectively reduced, increasing the measurement's susceptibility toward B0 inhomogeneities. To overcome these issues, gradient‐controlled local Larmor adjustment modifies the Larmor frequency locally and aligns the slice‐specific frequency responses on resonance by (1) unbalancing the slice gradient by a small constant amount and (2) modifying the RF phase cycles homogeneously across all slices. The concept is investigated using simulations and phantom experiments and applied to SMS‐accelerated bSSFP cine cardiovascular MR at 3 T.Results: Phantom and in vivo measurements demonstrate the successful removal of banding artifacts and restoration of the bSSFP frequency response using gradient‐controlled local Larmor adjustment. For large slice thicknesses and small slice distances, banding artifacts become slightly widened.Conclusion: Gradient‐controlled local Larmor adjustment successfully restores the frequency response in SMS‐accelerated bSSFP imaging without increasing the sequence's susceptibility toward eddy current effects. The concept facilitates combinations of the different SMS encoding concepts and provides a powerful way to actively control off‐resonance effects in slice‐accelerated bSSFP imaging.