Daniel Stäb
Research Subjects
Daniel Stäb has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
Karl P. Kunze
Faculty of Life Sciences and Medicine, School of Biomedical Engineering and Imaging Sciences King's College London London UK
4 shared publications- Peter Speier
Magnetic Resonance Siemens Healthcare GmbH Erlangen Germany
4 shared publications Radhouene Neji
Faculty of Life Sciences and Medicine, School of Biomedical Engineering and Imaging Sciences King's College London London UK
4 shared publications- Sébastien Roujol
School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine King's College London London UK
4 shared publications - Amedeo Chiribiri
Guy’s and St Thomas’ Hospital & School of Biomedical Engineering and Imaging Sciences, King’s College London Department of Cardiology Westminster Bridge Road, London SE1 7EH
3 shared publications - Giulio Ferrazzi
Philips Healthcare, Milan, Italy
3 shared publications
Latest Publications
- Open Access
- 15 February 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (6) , 3333-3340
Simultaneous Multi‐Slice Acceleration for Free‐Breathing Motion Corrected Late Gadolinium Enhancement Imaging
Purpose: The objective of this study was to develop and evaluate an accelerated free‐breathing motion corrected and averaged late gadolinium enhancement MRI (FB PSIR‐MoCo LGE) protocols. Methods: Simultaneous multi‐slice (SMS) bSSFP imaging with GC‐LOLA correction and a multiband factor of two was implemented into a FB PSIR‐MoCo LGE sequence with phase sensitive inversion recovery (PSIR) reconstruction. Two FB PSIR‐MoCo LGE protocols were acquired in 26 patients referred for clinical cardiac MRI: (1) SMS‐accelerated, and (2) non‐SMS reference. Myocardial sharpness, scar‐to‐blood CNR estimate (CNRe), scar‐to‐healthy myocardium CNRe, blood‐to‐healthy myocardium CNRe, and scar volume were assessed. Scar assessment was conducted in all LGE‐positive patients ( N = 10). Image quality (4‐point scale: 1— poor/non diagnostic , 4— excellent/diagnostic ) was assessed by consensus of two readers. Results: SMS resulted in a twofold reduction of acquisition time (reference: 3.7 ± 0.9 min, proposed: 1.9 ± 0.6 min, p < 0.001). Although both approaches resulted in good to excellent image quality, the proposed approach resulted in slightly reduced image quality scores (reference: 3.64 ± 0.36 vs. proposed: 3.46 ± 0.36, p = 0.001) and modest (∼20%) reduction in CNRe. Myocardial sharpness measures showed no statistically significant differences between the two approaches (0.37 ± 0.06 vs. 0.37 ± 0.05 mm −1 , p = 0.84). Importantly, both approaches were in excellent agreement for scar volume assessment (bias = 0.48 ± 0.86 mL, R 2 = 0.996). Conclusion: The proposed SMS FB PSIR‐MoCo LGE protocol reduced scan time by a factor of 2 when 16 slices were obtained, with minimal impact on image quality and CNRe, and no differences in myocardial sharpness. Importantly, it provided excellent agreement for myocardial scar assessment, in comparison to the reference FB PSIR‐MoCo LGE.
- 15 February 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (6) , 3333-3340
Open AccessSimultaneous Multi‐Slice Acceleration for Free‐Breathing Motion Corrected Late Gadolinium Enhancement Imaging
Purpose: The objective of this study was to develop and evaluate an accelerated free‐breathing motion corrected and averaged late gadolinium enhancement MRI (FB PSIR‐MoCo LGE) protocols. Methods: Simultaneous multi‐slice (SMS) bSSFP imaging with GC‐LOLA correction and a multiband factor of two was implemented into a FB PSIR‐MoCo LGE sequence with phase sensitive inversion recovery (PSIR) reconstruction. Two FB PSIR‐MoCo LGE protocols were acquired in 26 patients referred for clinical cardiac MRI: (1) SMS‐accelerated, and (2) non‐SMS reference. Myocardial sharpness, scar‐to‐blood CNR estimate (CNRe), scar‐to‐healthy myocardium CNRe, blood‐to‐healthy myocardium CNRe, and scar volume were assessed. Scar assessment was conducted in all LGE‐positive patients ( N = 10). Image quality (4‐point scale: 1— poor/non diagnostic , 4— excellent/diagnostic ) was assessed by consensus of two readers. Results: SMS resulted in a twofold reduction of acquisition time (reference: 3.7 ± 0.9 min, proposed: 1.9 ± 0.6 min, p < 0.001). Although both approaches resulted in good to excellent image quality, the proposed approach resulted in slightly reduced image quality scores (reference: 3.64 ± 0.36 vs. proposed: 3.46 ± 0.36, p = 0.001) and modest (∼20%) reduction in CNRe. Myocardial sharpness measures showed no statistically significant differences between the two approaches (0.37 ± 0.06 vs. 0.37 ± 0.05 mm −1 , p = 0.84). Importantly, both approaches were in excellent agreement for scar volume assessment (bias = 0.48 ± 0.86 mL, R 2 = 0.996). Conclusion: The proposed SMS FB PSIR‐MoCo LGE protocol reduced scan time by a factor of 2 when 16 slices were obtained, with minimal impact on image quality and CNRe, and no differences in myocardial sharpness. Importantly, it provided excellent agreement for myocardial scar assessment, in comparison to the reference FB PSIR‐MoCo LGE.
- 15 March 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 60 (6) , 2750-2753
Tissue Sodium Magnetic Resonance Imaging: Agreement and Repeatability of Manual Region of Interest Segmentation Methods
- 15 March 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 60 (6) , 2750-2753
Tissue Sodium Magnetic Resonance Imaging: Agreement and Repeatability of Manual Region of Interest Segmentation Methods
- Open Access
- 24 March 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (1) , 177-193
Hybrid adiabatic pulse with asymmetry (HAPY): An asymmetric adiabatic pulse with an application in pulsed arterial spin labeling at 7T
PurposeA new class of asymmetric adiabatic radiofrequency (RF) pulses, Hybrid Adiabatic Pulse with asYmmetry (HAPY), is designed to be used as the labeling pulse for Pulsed Arterial Spin labeling (PASL) at 7T to reduce overall specific absorption rate (SAR) while maintaining high labeling efficiency with B0$$ {\mathrm{B}}_0 $$ and B1+$$ {\mathrm{B}}_1<^>{+} $$ inhomogeneities. MethodsRealistic Delta B0$$ \Delta {\mathrm{B}}_0 $$ and B1+$$ {\mathrm{B}}_1<^>{+} $$ distributions were extracted from multiple in vivo scans. The proposed class of asymmetric pulses was parameterized and optimized considering these conditions. Simulation and phantoms experiments were performed to compare the optimized pulses with HS-3, GOIA, and trFOCI pulses. In vivo experiments were conducted to demonstrate the application of HAPY in PICORE PASL at 7T, compared with the GOIA and trFOCI pulses. ResultsHAPYs with different amounts of pulse energy reduction are obtained by the proposed optimization framework. Both simulation and phantom experiments demonstrate that HAPY achieves high labeling efficiency and high selectivity along the critical side despite B0$$ {\mathrm{B}}_0 $$ off-resonance and low B1+$$ {\mathrm{B}}_1<^>{+} $$ amplitude. In vivo experiments reveal that HAPY is able to generate robust perfusion signal with less overall SAR or shorter pulse repetition time, compared to the GOIA and trFOCI pulses. ConclusionThe HAPY class of pulses, obtained via systematic optimization tailored to the application of PASL at 7T, reduces power deposition without affecting labeling efficiency, which provides a prospect of further exploiting the benefits of ultra-high field in ASL.- 24 March 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (1) , 177-193
Open AccessHybrid adiabatic pulse with asymmetry (HAPY): An asymmetric adiabatic pulse with an application in pulsed arterial spin labeling at 7T
PurposeA new class of asymmetric adiabatic radiofrequency (RF) pulses, Hybrid Adiabatic Pulse with asYmmetry (HAPY), is designed to be used as the labeling pulse for Pulsed Arterial Spin labeling (PASL) at 7T to reduce overall specific absorption rate (SAR) while maintaining high labeling efficiency with B0$$ {\mathrm{B}}_0 $$ and B1+$$ {\mathrm{B}}_1<^>{+} $$ inhomogeneities. MethodsRealistic Delta B0$$ \Delta {\mathrm{B}}_0 $$ and B1+$$ {\mathrm{B}}_1<^>{+} $$ distributions were extracted from multiple in vivo scans. The proposed class of asymmetric pulses was parameterized and optimized considering these conditions. Simulation and phantoms experiments were performed to compare the optimized pulses with HS-3, GOIA, and trFOCI pulses. In vivo experiments were conducted to demonstrate the application of HAPY in PICORE PASL at 7T, compared with the GOIA and trFOCI pulses. ResultsHAPYs with different amounts of pulse energy reduction are obtained by the proposed optimization framework. Both simulation and phantom experiments demonstrate that HAPY achieves high labeling efficiency and high selectivity along the critical side despite B0$$ {\mathrm{B}}_0 $$ off-resonance and low B1+$$ {\mathrm{B}}_1<^>{+} $$ amplitude. In vivo experiments reveal that HAPY is able to generate robust perfusion signal with less overall SAR or shorter pulse repetition time, compared to the GOIA and trFOCI pulses. ConclusionThe HAPY class of pulses, obtained via systematic optimization tailored to the application of PASL at 7T, reduces power deposition without affecting labeling efficiency, which provides a prospect of further exploiting the benefits of ultra-high field in ASL. - Open Access
- 2 March 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (1) , 222-230
Single breath‐hold CINE imaging with combined simultaneous multislice and region‐optimized virtual coils
Purpose: To investigate the feasibility of combining simultaneous multislice (SMS) and region‐optimized virtual coils (ROVir) for single breath‐hold CINE imaging.Method: ROVir is a recent virtual coil approach that allows reduced‐field of view (FOV) imaging by localizing the signal from a region‐of‐interest (ROI) and/or suppressing the signal from unwanted spatial regions. In this work, ROVir is used for reduced‐FOV SMS bSSFP CINE imaging, which enables whole heart CINE with a single breath‐hold acquisition.Results: Reduced‐FOV CINE with either SMS‐only or ROVir‐only resulted in significant aliasing, with severely reduced image quality when compared to the full FOV reference CINE, while the visual appearance of aliasing was substantially reduced with the proposed SMS+ROVir. The end diastolic volume, end systolic volume, and ejection fraction obtained using the proposed approach were similar to the clinical reference (correlations of 0.92, 0.94, and 0.88, respectively with in each case, and biases of 0.1, 1.6 mL, and , respectively). No statistically significant differences for these parameters were found with a Wilcoxon rank test (p = 0.96, 0.20, and 0.40, respectively).Conclusion: We demonstrated that reduced‐FOV CINE imaging with SMS+ROVir enables single breath‐hold whole‐heart imaging without compromising visual image quality or quantitative cardiac function parameters.
- 2 March 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (1) , 222-230
Open AccessSingle breath‐hold CINE imaging with combined simultaneous multislice and region‐optimized virtual coils
Purpose: To investigate the feasibility of combining simultaneous multislice (SMS) and region‐optimized virtual coils (ROVir) for single breath‐hold CINE imaging.Method: ROVir is a recent virtual coil approach that allows reduced‐field of view (FOV) imaging by localizing the signal from a region‐of‐interest (ROI) and/or suppressing the signal from unwanted spatial regions. In this work, ROVir is used for reduced‐FOV SMS bSSFP CINE imaging, which enables whole heart CINE with a single breath‐hold acquisition.Results: Reduced‐FOV CINE with either SMS‐only or ROVir‐only resulted in significant aliasing, with severely reduced image quality when compared to the full FOV reference CINE, while the visual appearance of aliasing was substantially reduced with the proposed SMS+ROVir. The end diastolic volume, end systolic volume, and ejection fraction obtained using the proposed approach were similar to the clinical reference (correlations of 0.92, 0.94, and 0.88, respectively with in each case, and biases of 0.1, 1.6 mL, and , respectively). No statistically significant differences for these parameters were found with a Wilcoxon rank test (p = 0.96, 0.20, and 0.40, respectively).Conclusion: We demonstrated that reduced‐FOV CINE imaging with SMS+ROVir enables single breath‐hold whole‐heart imaging without compromising visual image quality or quantitative cardiac function parameters.
- Open Access
- 28 March 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (2) , 663-675
Simultaneous multislice steady‐state free precession myocardial perfusion with full left ventricular coverage and high resolution at 1.5 T
Purpose: To implement and evaluate a simultaneous multi‐slice balanced SSFP (SMS‐bSSFP) perfusion sequence and compressed sensing reconstruction for cardiac MR perfusion imaging with full left ventricular (LV) coverage (nine slices/heartbeat) and high spatial resolution (1.4 × 1.4 mm2) at 1.5T.Methods: A preliminary study was performed to evaluate the performance of blipped controlled aliasing in parallel imaging (CAIPI) and RF‐CAIPI with gradient‐controlled local Larmor adjustment (GC‐LOLA) in the presence of fat. A nine‐slice SMS‐bSSFP sequence using RF‐CAIPI with GC‐LOLA with high spatial resolution (1.4 × 1.4 mm2) and a conventional three‐slice sequence with conventional spatial resolution (1.9 × 1.9 mm2) were then acquired in 10 patients under rest conditions. Qualitative assessment was performed to assess image quality and perceived signal‐to‐noise ratio (SNR) on a 4‐point scale (0: poor image quality/low SNR; 3: excellent image quality/high SNR), and the number of myocardial segments with diagnostic image quality was recorded. Quantitative measurements of myocardial sharpness and upslope index were performed.Results: Fat signal leakage was significantly higher for blipped CAIPI than for RF‐CAIPI with GC‐LOLA (7.9% vs. 1.2%, p = 0.010). All 10 SMS‐bSSFP perfusion datasets resulted in 16/16 diagnostic myocardial segments. There were no significant differences between the SMS and conventional acquisitions in terms of image quality (2.6 ± 0.6 vs. 2.7 ± 0.2, p = 0.8) or perceived SNR (2.8 ± 0.3 vs. 2.7 ± 0.3, p = 0.3). Inter‐reader variability was good for both image quality (ICC = 0.84) and perceived SNR (ICC = 0.70). Myocardial sharpness was improved using the SMS sequence compared to the conventional sequence (0.37 ± 0.08 vs 0.32 ± 0.05, p < 0.001). There was no significant difference between measurements of upslope index for the SMS and conventional sequences (0.11 ± 0.04 vs. 0.11 ± 0.03, p = 0.84).Conclusion: SMS‐bSSFP with multiband factor 3 and compressed sensing reconstruction enables cardiac MR perfusion imaging with three‐fold increased spatial coverage and improved myocardial sharpness compared to a conventional sequence, without compromising perceived SNR, image quality, upslope index or number of diagnostic segments.
- 28 March 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (2) , 663-675
Open AccessSimultaneous multislice steady‐state free precession myocardial perfusion with full left ventricular coverage and high resolution at 1.5 T
Purpose: To implement and evaluate a simultaneous multi‐slice balanced SSFP (SMS‐bSSFP) perfusion sequence and compressed sensing reconstruction for cardiac MR perfusion imaging with full left ventricular (LV) coverage (nine slices/heartbeat) and high spatial resolution (1.4 × 1.4 mm2) at 1.5T.Methods: A preliminary study was performed to evaluate the performance of blipped controlled aliasing in parallel imaging (CAIPI) and RF‐CAIPI with gradient‐controlled local Larmor adjustment (GC‐LOLA) in the presence of fat. A nine‐slice SMS‐bSSFP sequence using RF‐CAIPI with GC‐LOLA with high spatial resolution (1.4 × 1.4 mm2) and a conventional three‐slice sequence with conventional spatial resolution (1.9 × 1.9 mm2) were then acquired in 10 patients under rest conditions. Qualitative assessment was performed to assess image quality and perceived signal‐to‐noise ratio (SNR) on a 4‐point scale (0: poor image quality/low SNR; 3: excellent image quality/high SNR), and the number of myocardial segments with diagnostic image quality was recorded. Quantitative measurements of myocardial sharpness and upslope index were performed.Results: Fat signal leakage was significantly higher for blipped CAIPI than for RF‐CAIPI with GC‐LOLA (7.9% vs. 1.2%, p = 0.010). All 10 SMS‐bSSFP perfusion datasets resulted in 16/16 diagnostic myocardial segments. There were no significant differences between the SMS and conventional acquisitions in terms of image quality (2.6 ± 0.6 vs. 2.7 ± 0.2, p = 0.8) or perceived SNR (2.8 ± 0.3 vs. 2.7 ± 0.3, p = 0.3). Inter‐reader variability was good for both image quality (ICC = 0.84) and perceived SNR (ICC = 0.70). Myocardial sharpness was improved using the SMS sequence compared to the conventional sequence (0.37 ± 0.08 vs 0.32 ± 0.05, p < 0.001). There was no significant difference between measurements of upslope index for the SMS and conventional sequences (0.11 ± 0.04 vs. 0.11 ± 0.03, p = 0.84).Conclusion: SMS‐bSSFP with multiband factor 3 and compressed sensing reconstruction enables cardiac MR perfusion imaging with three‐fold increased spatial coverage and improved myocardial sharpness compared to a conventional sequence, without compromising perceived SNR, image quality, upslope index or number of diagnostic segments.
- Open Access
- 10 March 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (2) , 663-676
All‐systolic first‐pass myocardial rest perfusion at a long saturation time using simultaneous multi‐slice imaging and compressed sensing acceleration
Purpose: To enable all‐systolic first‐pass rest myocardial perfusion with long saturation times. To investigate the change in perfusion contrast and dark rim artefacts through simulations and surrogate measurements.Methods: Simulations were employed to investigate optimal saturation time for myocardium‐perfusion defect contrast and blood‐to‐myocardium signal ratios. Two saturation recovery blocks with long/short saturation times (LTS/STS) were employed to image 3 slices at end‐systole and diastole. Simultaneous multi‐slice balanced steady state free precession imaging and compressed sensing acceleration were combined. The sequence was compared to a 3 slice‐by‐slice clinical protocol in 10 patients. Quantitative assessment of myocardium‐peak pre contrast and blood‐to‐myocardium signal ratios, as well as qualitative assessment of perceived SNR, image quality, blurring, and dark rim artefacts, were performed.Results: Simulations showed that with a bolus of 0.075 mmol/kg, a LTS of 240‐470 ms led to a relative increase in myocardium‐perfusion defect contrast of 34% ± 9%‐28% ± 27% than a STS = 120 ms, while reducing blood‐to‐myocardium signal ratio by 18% ± 10%‐32% ± 14% at peak myocardium. With a bolus of 0.05 mmol/kg, LTS was 320‐570 ms with an increase in myocardium‐perfusion defect contrast of 63% ± 13%‐62% ± 29%. Across patients, LTS led to an average increase in myocardium‐peak pre contrast of 59% (P < .001) at peak myocardium and a lower blood‐to‐myocardium signal ratio of 47% (P < .001) and 15% (P < .001) at peak blood/myocardium. LTS had improved motion robustness (P = .002), image quality (P < .001), and decreased dark rim artefacts (P = .008) than the clinical protocol.Conclusion: All‐systolic rest perfusion can be achieved by combining simultaneous multi‐slice and compressed sensing acceleration, enabling 3‐slice cardiac coverage with reduced motion and dark rim artefacts. Numerical simulations indicate that myocardium‐perfusion defect contrast increases at LTS.
- 10 March 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (2) , 663-676
Open AccessAll‐systolic first‐pass myocardial rest perfusion at a long saturation time using simultaneous multi‐slice imaging and compressed sensing acceleration
Purpose: To enable all‐systolic first‐pass rest myocardial perfusion with long saturation times. To investigate the change in perfusion contrast and dark rim artefacts through simulations and surrogate measurements.Methods: Simulations were employed to investigate optimal saturation time for myocardium‐perfusion defect contrast and blood‐to‐myocardium signal ratios. Two saturation recovery blocks with long/short saturation times (LTS/STS) were employed to image 3 slices at end‐systole and diastole. Simultaneous multi‐slice balanced steady state free precession imaging and compressed sensing acceleration were combined. The sequence was compared to a 3 slice‐by‐slice clinical protocol in 10 patients. Quantitative assessment of myocardium‐peak pre contrast and blood‐to‐myocardium signal ratios, as well as qualitative assessment of perceived SNR, image quality, blurring, and dark rim artefacts, were performed.Results: Simulations showed that with a bolus of 0.075 mmol/kg, a LTS of 240‐470 ms led to a relative increase in myocardium‐perfusion defect contrast of 34% ± 9%‐28% ± 27% than a STS = 120 ms, while reducing blood‐to‐myocardium signal ratio by 18% ± 10%‐32% ± 14% at peak myocardium. With a bolus of 0.05 mmol/kg, LTS was 320‐570 ms with an increase in myocardium‐perfusion defect contrast of 63% ± 13%‐62% ± 29%. Across patients, LTS led to an average increase in myocardium‐peak pre contrast of 59% (P < .001) at peak myocardium and a lower blood‐to‐myocardium signal ratio of 47% (P < .001) and 15% (P < .001) at peak blood/myocardium. LTS had improved motion robustness (P = .002), image quality (P < .001), and decreased dark rim artefacts (P = .008) than the clinical protocol.Conclusion: All‐systolic rest perfusion can be achieved by combining simultaneous multi‐slice and compressed sensing acceleration, enabling 3‐slice cardiac coverage with reduced motion and dark rim artefacts. Numerical simulations indicate that myocardium‐perfusion defect contrast increases at LTS.
- Open Access
- 21 October 2020
- Published by Springer Nature in Scientific Data
- Vol. 7 (1) , 1-12
Simultaneous BOLD-fMRI and constant infusion FDG-PET data of the resting human brain
Simultaneous [18 F]-fluorodeoxyglucose positron emission tomography and functional magnetic resonance imaging (FDG-PET/fMRI) provides the capability to image two sources of energetic dynamics in the brain – cerebral glucose uptake and the cerebrovascular haemodynamic response. Resting-state fMRI connectivity has been enormously useful for characterising interactions between distributed brain regions in humans. Metabolic connectivity has recently emerged as a complementary measure to investigate brain network dynamics. Functional PET (fPET) is a new approach for measuring FDG uptake with high temporal resolution and has recently shown promise for assessing the dynamics of neural metabolism. Simultaneous fMRI/fPET is a relatively new hybrid imaging modality, with only a few biomedical imaging research facilities able to acquire FDG PET and BOLD fMRI data simultaneously. We present data for n = 27 healthy young adults (18–20 yrs) who underwent a 95-min simultaneous fMRI/fPET scan while resting with their eyes open. This dataset provides significant re-use value to understand the neural dynamics of glucose metabolism and the haemodynamic response, the synchrony, and interaction between these measures, and the development of new single- and multi-modality image preparation and analysis procedures.
- 21 October 2020
- Published by Springer Nature in Scientific Data
- Vol. 7 (1) , 1-12
Open AccessSimultaneous BOLD-fMRI and constant infusion FDG-PET data of the resting human brain
Simultaneous [18 F]-fluorodeoxyglucose positron emission tomography and functional magnetic resonance imaging (FDG-PET/fMRI) provides the capability to image two sources of energetic dynamics in the brain – cerebral glucose uptake and the cerebrovascular haemodynamic response. Resting-state fMRI connectivity has been enormously useful for characterising interactions between distributed brain regions in humans. Metabolic connectivity has recently emerged as a complementary measure to investigate brain network dynamics. Functional PET (fPET) is a new approach for measuring FDG uptake with high temporal resolution and has recently shown promise for assessing the dynamics of neural metabolism. Simultaneous fMRI/fPET is a relatively new hybrid imaging modality, with only a few biomedical imaging research facilities able to acquire FDG PET and BOLD fMRI data simultaneously. We present data for n = 27 healthy young adults (18–20 yrs) who underwent a 95-min simultaneous fMRI/fPET scan while resting with their eyes open. This dataset provides significant re-use value to understand the neural dynamics of glucose metabolism and the haemodynamic response, the synchrony, and interaction between these measures, and the development of new single- and multi-modality image preparation and analysis procedures.
- Open Access
- 12 June 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (6) , 3103-3116
Combined simultaneous multislice bSSFP and compressed sensing for first‐pass myocardial perfusion at 1.5 T with high spatial resolution and coverage
Purpose: To implement and evaluate a pseudorandom undersampling scheme for combined simultaneous multislice (SMS) balanced SSFP (bSSFP) and compressed‐sensing (CS) reconstruction to enable myocardial perfusion imaging with high spatial resolution and coverage at 1.5 T.Methods: A prospective pseudorandom undersampling scheme that is compatible with SMS‐bSSFP phase‐cycling requirements and CS was developed. The SMS‐bSSFP CS with pseudorandom and linear undersampling schemes were compared in a phantom. A high‐resolution (1.4 × 1.4 mm2) six‐slice SMS‐bSSFP CS perfusion sequence was compared with a conventional (1.9 × 1.9 mm2) three‐slice sequence in 10 patients. Qualitative assessment of image quality, perceived SNR, and number of diagnostic segments and quantitative measurements of sharpness, upslope index, and contrast ratio were performed.Results: In phantom experiments, pseudorandom undersampling resulted in residual artifact (RMS error) reduction by a factor of 7 compared with linear undersampling. In vivo, the proposed sequence demonstrated higher perceived SNR (2.9 ± 0.3 vs. 2.2 ± 0.6, P = .04), improved sharpness (0.35 ± 0.03 vs. 0.32 ± 0.05, P = .01), and a higher number of diagnostic segments (100% vs. 94%, P = .03) compared with the conventional sequence. There were no significant differences between the sequences in terms of image quality (2.5 ± 0.4 vs. 2.8 ± 0.2, P = .08), upslope index (0.11 ± 0.02 vs. 0.10 ± 0.01, P = .3), or contrast ratio (3.28 ± 0.35 vs. 3.36 ± 0.43, P = .7).Conclusion: A pseudorandom k‐space undersampling compatible with SMS‐bSSFP and CS reconstruction has been developed and enables cardiac MR perfusion imaging with increased spatial resolution and myocardial coverage, increased number of diagnostic segments and perceived SNR, and no difference in image quality, upslope index, and contrast ratio.
- 12 June 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (6) , 3103-3116
Open AccessCombined simultaneous multislice bSSFP and compressed sensing for first‐pass myocardial perfusion at 1.5 T with high spatial resolution and coverage
Purpose: To implement and evaluate a pseudorandom undersampling scheme for combined simultaneous multislice (SMS) balanced SSFP (bSSFP) and compressed‐sensing (CS) reconstruction to enable myocardial perfusion imaging with high spatial resolution and coverage at 1.5 T.Methods: A prospective pseudorandom undersampling scheme that is compatible with SMS‐bSSFP phase‐cycling requirements and CS was developed. The SMS‐bSSFP CS with pseudorandom and linear undersampling schemes were compared in a phantom. A high‐resolution (1.4 × 1.4 mm2) six‐slice SMS‐bSSFP CS perfusion sequence was compared with a conventional (1.9 × 1.9 mm2) three‐slice sequence in 10 patients. Qualitative assessment of image quality, perceived SNR, and number of diagnostic segments and quantitative measurements of sharpness, upslope index, and contrast ratio were performed.Results: In phantom experiments, pseudorandom undersampling resulted in residual artifact (RMS error) reduction by a factor of 7 compared with linear undersampling. In vivo, the proposed sequence demonstrated higher perceived SNR (2.9 ± 0.3 vs. 2.2 ± 0.6, P = .04), improved sharpness (0.35 ± 0.03 vs. 0.32 ± 0.05, P = .01), and a higher number of diagnostic segments (100% vs. 94%, P = .03) compared with the conventional sequence. There were no significant differences between the sequences in terms of image quality (2.5 ± 0.4 vs. 2.8 ± 0.2, P = .08), upslope index (0.11 ± 0.02 vs. 0.10 ± 0.01, P = .3), or contrast ratio (3.28 ± 0.35 vs. 3.36 ± 0.43, P = .7).Conclusion: A pseudorandom k‐space undersampling compatible with SMS‐bSSFP and CS reconstruction has been developed and enables cardiac MR perfusion imaging with increased spatial resolution and myocardial coverage, increased number of diagnostic segments and perceived SNR, and no difference in image quality, upslope index, and contrast ratio.
- 29 July 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (1) , 129-139
Gradient‐controlled local Larmor adjustment (GC‐LOLA) for simultaneous multislice bSSFP imaging with improved banding behavior
Purpose: Simultaneous multislice (SMS) accelerated balanced SSFP (bSSFP) imaging can be impaired by off‐resonance effects, due to slice‐specific alterations in the frequency response. In this work, we introduce gradient‐controlled local Larmor adjustment as a means to restore the frequency response and to stabilize SMS‐accelerated bSSFP imaging with respect to banding artifacts.Methods: Providing each simultaneously excited slice with an individual RF phase cycle in SMS‐accelerated bSSFP imaging results in the sequence's frequency response being shifted slice‐specifically along the off‐resonance axis. The net available pass‐band for imaging is effectively reduced, increasing the measurement's susceptibility toward B0 inhomogeneities. To overcome these issues, gradient‐controlled local Larmor adjustment modifies the Larmor frequency locally and aligns the slice‐specific frequency responses on resonance by (1) unbalancing the slice gradient by a small constant amount and (2) modifying the RF phase cycles homogeneously across all slices. The concept is investigated using simulations and phantom experiments and applied to SMS‐accelerated bSSFP cine cardiovascular MR at 3 T.Results: Phantom and in vivo measurements demonstrate the successful removal of banding artifacts and restoration of the bSSFP frequency response using gradient‐controlled local Larmor adjustment. For large slice thicknesses and small slice distances, banding artifacts become slightly widened.Conclusion: Gradient‐controlled local Larmor adjustment successfully restores the frequency response in SMS‐accelerated bSSFP imaging without increasing the sequence's susceptibility toward eddy current effects. The concept facilitates combinations of the different SMS encoding concepts and provides a powerful way to actively control off‐resonance effects in slice‐accelerated bSSFP imaging.
- 29 July 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (1) , 129-139
Gradient‐controlled local Larmor adjustment (GC‐LOLA) for simultaneous multislice bSSFP imaging with improved banding behavior
Purpose: Simultaneous multislice (SMS) accelerated balanced SSFP (bSSFP) imaging can be impaired by off‐resonance effects, due to slice‐specific alterations in the frequency response. In this work, we introduce gradient‐controlled local Larmor adjustment as a means to restore the frequency response and to stabilize SMS‐accelerated bSSFP imaging with respect to banding artifacts.Methods: Providing each simultaneously excited slice with an individual RF phase cycle in SMS‐accelerated bSSFP imaging results in the sequence's frequency response being shifted slice‐specifically along the off‐resonance axis. The net available pass‐band for imaging is effectively reduced, increasing the measurement's susceptibility toward B0 inhomogeneities. To overcome these issues, gradient‐controlled local Larmor adjustment modifies the Larmor frequency locally and aligns the slice‐specific frequency responses on resonance by (1) unbalancing the slice gradient by a small constant amount and (2) modifying the RF phase cycles homogeneously across all slices. The concept is investigated using simulations and phantom experiments and applied to SMS‐accelerated bSSFP cine cardiovascular MR at 3 T.Results: Phantom and in vivo measurements demonstrate the successful removal of banding artifacts and restoration of the bSSFP frequency response using gradient‐controlled local Larmor adjustment. For large slice thicknesses and small slice distances, banding artifacts become slightly widened.Conclusion: Gradient‐controlled local Larmor adjustment successfully restores the frequency response in SMS‐accelerated bSSFP imaging without increasing the sequence's susceptibility toward eddy current effects. The concept facilitates combinations of the different SMS encoding concepts and provides a powerful way to actively control off‐resonance effects in slice‐accelerated bSSFP imaging.