Tao Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tao Sun has a total of 103 co-authors. Here are the top co-authors by number of shared publications:
- Zhiqiang Cai
Shenyang University of Technology
22 shared publications Shaoqiang Hu
College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang, 471934, P. R. China
8 shared publicationsQiuchen Huang
Liaoning Province Professional and Technical Innovation Center for Fine Chemical Engineering of Aromatics Downstream, School of Petrochemical Engineering, Shenyang University of Technology, Liaoyang, People’s Republic of China
7 shared publicationsRuonan Chen
Liaoning Province Professional and Technical Innovation Center for Fine Chemical Engineering of Aromatics Downstream, School of Petrochemical Engineering, Shenyang University of Technology, Liaoyang, People’s Republic of China
7 shared publications- Shaoqiang Hu
College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang, 471934, PR China
7 shared publications Wei Zhang
Shenyang Univ Technol, Liaoning Prov Profess & Tech Innovat Ctr Fine Chem, Sch Petrochem Engn, Liaoyang 111003, Peoples R China
7 shared publications
Latest Publications
- 18 September 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (38) , 28465-28474
Customizable Flow Modulation in GC×GC: A Configurable Pressure-Pulse Sampling Strategy via Active Venting
A customizable four-port flow modulator, driven by a configurable pressure-pulse sampling strategy, is developed for comprehensive two-dimensional gas chromatography (GC×GC). By reconfiguring the conventional junction into a cross fitting, we introduce an active venting restrictor that provides a dedicated outlet for the primary-column effluent. Maintaining the venting flow at least equal to the primary flow establishes a flow-balance condition that suppresses observable breakthrough and the associated baseline elevation. Supported by this actively vented design, an electronic pneumatic controller (EPC) provides precise control over transient sampling. Under dynamic pressure compensation, programming this EPC to track the primary pressure ramp ensures a more consistent sampling response throughout the run, thereby mitigating thermal discrimination. More importantly, targeted adjustment of the sampling pressure enables customized enrichment, allowing the simultaneous analysis of major matrix constituents (up to ∼20%) and trace analytes with an LOD down to ∼4 ppm within a single run. Under optimized conditions, the platform yielded a theoretical two-dimensional peak capacity of ∼12300 and quantitative results within the reproducibility limits specified by ASTM International standard test methods. Long-term robustness was further confirmed by retention-time stability over 180 h of cumulative runtime. By combining a hardware-defined operating window with programmable pressure control, this customizable modulation system substantially broadens the operational flexibility of flow-modulated GC×GC.
- 18 September 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (38) , 28465-28474
Customizable Flow Modulation in GC×GC: A Configurable Pressure-Pulse Sampling Strategy via Active Venting
A customizable four-port flow modulator, driven by a configurable pressure-pulse sampling strategy, is developed for comprehensive two-dimensional gas chromatography (GC×GC). By reconfiguring the conventional junction into a cross fitting, we introduce an active venting restrictor that provides a dedicated outlet for the primary-column effluent. Maintaining the venting flow at least equal to the primary flow establishes a flow-balance condition that suppresses observable breakthrough and the associated baseline elevation. Supported by this actively vented design, an electronic pneumatic controller (EPC) provides precise control over transient sampling. Under dynamic pressure compensation, programming this EPC to track the primary pressure ramp ensures a more consistent sampling response throughout the run, thereby mitigating thermal discrimination. More importantly, targeted adjustment of the sampling pressure enables customized enrichment, allowing the simultaneous analysis of major matrix constituents (up to ∼20%) and trace analytes with an LOD down to ∼4 ppm within a single run. Under optimized conditions, the platform yielded a theoretical two-dimensional peak capacity of ∼12300 and quantitative results within the reproducibility limits specified by ASTM International standard test methods. Long-term robustness was further confirmed by retention-time stability over 180 h of cumulative runtime. By combining a hardware-defined operating window with programmable pressure control, this customizable modulation system substantially broadens the operational flexibility of flow-modulated GC×GC.
- 30 March 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1777, 466954
Jellyfish-like gas chromatographic stationary phase based on esterified cyclotriveratrylene
- 30 March 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1777, 466954
Jellyfish-like gas chromatographic stationary phase based on esterified cyclotriveratrylene
- 1 February 2026
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 81 (2) , 345-355
Imidazolium Ionic Liquid-Functionalized Extended Pillar[6]Arene with High Selectivity for Gas-Chromatographic Separations
Pillar[n]arenes (n = 5–10), novel macrocycles, are gaining prominence in supramolecular studies owing to their distinctive three-dimensional architecture featuring a π-electron-rich cavity and have emerged as a key synthetic macrocyclic host in research. Extended pillar[n]arenes (Ep[ n ]As) notably feature sizable internal voids, adaptable structures, versatile cavity shapes, and ease of synthesis. This work presents the first example of imidazolium ionic liquid-functionalized Ep[n]As (BpP6A-C10-IM-C8[NTf2]) as a gas chromatography stationary phase. The BpP6A-C10-IM-C8[NTf2] column was prepared by the static method, exhibiting medium polarity and high column efficiency (4660 plates/m, k = 2.29). The separation performance of the prepared column was evaluated for analytes, including a mixture of 22 analytes, more than 12 positional isomers, and 8 cis-/trans-isomers. Furthermore, the chromatograms of the challenging isomers of bromonitrobenzenes, chloronitrobenzenes, bromobenzaldehydes, toluidines, and dimethylanilines on the BpP6A-C10-IM-C8[NTf2] column were compared with those on the BpP6A-C10 column and commercial HP-5 and HP-35 columns. The BpP6A-C10-IM-C8[NTf2] column also showed high selectivity for biphenyl isomers, including methylbiphenyls, iodobiphenyls, and bromobiphenyls.
- 1 February 2026
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 81 (2) , 345-355
Imidazolium Ionic Liquid-Functionalized Extended Pillar[6]Arene with High Selectivity for Gas-Chromatographic Separations
Pillar[n]arenes (n = 5–10), novel macrocycles, are gaining prominence in supramolecular studies owing to their distinctive three-dimensional architecture featuring a π-electron-rich cavity and have emerged as a key synthetic macrocyclic host in research. Extended pillar[n]arenes (Ep[ n ]As) notably feature sizable internal voids, adaptable structures, versatile cavity shapes, and ease of synthesis. This work presents the first example of imidazolium ionic liquid-functionalized Ep[n]As (BpP6A-C10-IM-C8[NTf2]) as a gas chromatography stationary phase. The BpP6A-C10-IM-C8[NTf2] column was prepared by the static method, exhibiting medium polarity and high column efficiency (4660 plates/m, k = 2.29). The separation performance of the prepared column was evaluated for analytes, including a mixture of 22 analytes, more than 12 positional isomers, and 8 cis-/trans-isomers. Furthermore, the chromatograms of the challenging isomers of bromonitrobenzenes, chloronitrobenzenes, bromobenzaldehydes, toluidines, and dimethylanilines on the BpP6A-C10-IM-C8[NTf2] column were compared with those on the BpP6A-C10 column and commercial HP-5 and HP-35 columns. The BpP6A-C10-IM-C8[NTf2] column also showed high selectivity for biphenyl isomers, including methylbiphenyls, iodobiphenyls, and bromobiphenyls.
- 12 November 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (30) , 7095-7107
A novel high-performance gas chromatographic stationary phase based on C10 alkyl-modified cyclotriveratrilene exploiting nanoscale separation channels
Cyclotriveratrylene (CTV) possesses a rigid and bowl-shaped architecture with a π-electron-rich cavity. In this work, CTV modified with C10 alkyl chains (CTV-C10) has been synthesized and used for the first time as a stationary phase for gas chromatography (GC) analysis. The statically coated CTV-C10 column showed moderate polarity and high column efficiency (3446 plates m−1, determined by n-dodecane at 120 °C). Due to its nanoscale channels, the CTV-C10 column displayed a strong affinity for aromatic compounds. Compared with CTV and commercial HP-5 and HP-35 columns, the CTV-C10 column exhibited better performance for the critical resolution of dibromobenzene, dichlorobenzene, and chloronitrobenzene isomers. Moreover, CTV-C10 columns showed 0.02%, 0.09%, and 4.96% repeatability RSD values for intra-day, inter-day, and between-columns, respectively. This study demonstrated the feasibility of CTV-C10 columns, providing a new perspective for developing selective nanoscale separation channels through CTV stationary phases in chromatographic analysis. Graphical abstract
- 12 November 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (30) , 7095-7107
A novel high-performance gas chromatographic stationary phase based on C10 alkyl-modified cyclotriveratrilene exploiting nanoscale separation channels
Cyclotriveratrylene (CTV) possesses a rigid and bowl-shaped architecture with a π-electron-rich cavity. In this work, CTV modified with C10 alkyl chains (CTV-C10) has been synthesized and used for the first time as a stationary phase for gas chromatography (GC) analysis. The statically coated CTV-C10 column showed moderate polarity and high column efficiency (3446 plates m−1, determined by n-dodecane at 120 °C). Due to its nanoscale channels, the CTV-C10 column displayed a strong affinity for aromatic compounds. Compared with CTV and commercial HP-5 and HP-35 columns, the CTV-C10 column exhibited better performance for the critical resolution of dibromobenzene, dichlorobenzene, and chloronitrobenzene isomers. Moreover, CTV-C10 columns showed 0.02%, 0.09%, and 4.96% repeatability RSD values for intra-day, inter-day, and between-columns, respectively. This study demonstrated the feasibility of CTV-C10 columns, providing a new perspective for developing selective nanoscale separation channels through CTV stationary phases in chromatographic analysis. Graphical abstract
- 17 January 2024
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 416 (6) , 1321-1335
Ester-functionalized pillar[6]arene as the gas chromatographic stationary phase with high-resolution performance towards the challenging isomers of xylenes, diethylbenzenes, and ethyltoluenes
This work presents the first example of the utilization of polar ester group functionalized pillar[6]arene (P6A-C10-OAc) as a stationary phase for capillary gas chromatographic (GC) separations. The statically coated P6A-C10-OAc column showed a high column efficiency of 5393 plates/m and moderate polar nature. Its resolving capability and retention behaviors were investigated for a mixture of 20 analytes and more than a dozen isomers from apolar to polar in nature. As evidenced, the P6A-C10-OAc column achieved high-resolution separations of all the analytes and good inertness. Importantly, it exhibited distinctly advantageous performance for high resolution of the challenging isomers of xylenes, diethylbenzenes, ethyltoluenes, and halobenzenes over the commercial HP-5 (5% phenyl dimethyl polysiloxane), HP-35 (25% phenyl dimethyl polysiloxane), and PEG-20M (polyethylene glycol) columns. Graphical Abstract
- 17 January 2024
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 416 (6) , 1321-1335
Ester-functionalized pillar[6]arene as the gas chromatographic stationary phase with high-resolution performance towards the challenging isomers of xylenes, diethylbenzenes, and ethyltoluenes
This work presents the first example of the utilization of polar ester group functionalized pillar[6]arene (P6A-C10-OAc) as a stationary phase for capillary gas chromatographic (GC) separations. The statically coated P6A-C10-OAc column showed a high column efficiency of 5393 plates/m and moderate polar nature. Its resolving capability and retention behaviors were investigated for a mixture of 20 analytes and more than a dozen isomers from apolar to polar in nature. As evidenced, the P6A-C10-OAc column achieved high-resolution separations of all the analytes and good inertness. Importantly, it exhibited distinctly advantageous performance for high resolution of the challenging isomers of xylenes, diethylbenzenes, ethyltoluenes, and halobenzenes over the commercial HP-5 (5% phenyl dimethyl polysiloxane), HP-35 (25% phenyl dimethyl polysiloxane), and PEG-20M (polyethylene glycol) columns. Graphical Abstract
- 5 January 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1291, 342221
Multipurpose new gas chromatography column based on pillararenes functionalized with imidazolium ionic liquids
- 5 January 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1291, 342221
Multipurpose new gas chromatography column based on pillararenes functionalized with imidazolium ionic liquids
- 3 January 2024
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 149 (3) , 925-934
Hydroxyl-functionalized pillar[5]arene with high separation performance for gas chromatography
Here we report the first example of employing hydroxyl-functionalized pillar[5]arene (P5A-C10-OH) as stationary phase for capillary gas chromatographic (GC) separations. The statically coated P5A-C10-OH capillary column possessed moderate polarity and column efficiency of 3233 plates per m determined by n-dodecane. As a result, the P5A-C10-OH column exhibited high-resolution capability for the mixture of 17 analytes from apolar to polar nature. Importantly, it exhibited advantageous performance for high resolution of the challenging isomers of bromonitrobenzene, chloroaniline, bromoaniline, iodoaniline and dimethylaniline with good peak shapes over the P5A-C10 and commercial HP-35 columns. In addition, eight cis-/trans-isomers with diverse types were baseline separated on the P5A-C10-OH column. And the application of detecting isomeric impurities in real samples gave strong evidence of its potential and feasibility for the viable GC analysis.
- 3 January 2024
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 149 (3) , 925-934
Hydroxyl-functionalized pillar[5]arene with high separation performance for gas chromatography
Here we report the first example of employing hydroxyl-functionalized pillar[5]arene (P5A-C10-OH) as stationary phase for capillary gas chromatographic (GC) separations. The statically coated P5A-C10-OH capillary column possessed moderate polarity and column efficiency of 3233 plates per m determined by n-dodecane. As a result, the P5A-C10-OH column exhibited high-resolution capability for the mixture of 17 analytes from apolar to polar nature. Importantly, it exhibited advantageous performance for high resolution of the challenging isomers of bromonitrobenzene, chloroaniline, bromoaniline, iodoaniline and dimethylaniline with good peak shapes over the P5A-C10 and commercial HP-35 columns. In addition, eight cis-/trans-isomers with diverse types were baseline separated on the P5A-C10-OH column. And the application of detecting isomeric impurities in real samples gave strong evidence of its potential and feasibility for the viable GC analysis.
- 20 March 2023
- Published by Slovenian Chemical Society in Acta Chimica Slovenica
- Vol. 70 (1) , 1-11
An Amphiphilic Star-Shaped Polymer (Star-PEG-PCL2) used as a Stationary Phase for GC
- 20 March 2023
- Published by Slovenian Chemical Society in Acta Chimica Slovenica
- Vol. 70 (1) , 1-11
An Amphiphilic Star-Shaped Polymer (Star-PEG-PCL2) used as a Stationary Phase for GC