Shaoqiang Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shaoqiang Hu has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Tao Sun
College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang, 471934, PR China
7 shared publications - Zhiqiang Cai
Shenyang University of Technology
7 shared publications Tao Sun
College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang, 471934, PR China
3 shared publicationsXianming Liu
College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang, 471934, Henan, PR China
3 shared publicationsKaixin Ren
Luoyang Normal Univ, Coll Chem & Chem Engn, Henan Key Lab Funct Oriented Porous Mat, Luoyang 471934, Peoples R China
2 shared publications- Maurizio Quinto
University of Foggia
2 shared publications
Latest Publications
- 5 January 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1291, 342221
Multipurpose new gas chromatography column based on pillararenes functionalized with imidazolium ionic liquids
- 5 January 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1291, 342221
Multipurpose new gas chromatography column based on pillararenes functionalized with imidazolium ionic liquids
- Open Access
Copper (II) Ions Induced Self-Disproportionation of Enantiomers in Capillary Electrophoresis for the Quantification of Atenolol Enantiomers
Despite the fact that the self-disproportionation of enantiomers (SDE) has been found for several decades and has been widely used in crystallization, sublimation and chromatography for the purification or separation of nonracemic compounds, the phenomenon of SDE in capillary electrophoresis (CE) has never been reported up to now. Here, a new approach to separate enantiomers in CE based on SDE was demonstrated by introducing copper (II) ions into the separation media. The enantiomers of atenolol interact with copper ions to produce positively charged complexes with different electrophoretic mobilities from the single molecules. The dynamic equilibrium between homo- or heterochiral complexes (associates) and single molecules of atenolol enantiomers supports the manifestation of SDE. Different mobilities of the single molecules and associates, and different distribution of two enantiomers between the single molecules and associates caused by their different concentrations, produce a net difference in electrodriven migration velocities of the two enantiomers. The relative movement of two enantiomers causes a zone depleted in one enantiomer at the rear end of sample segment, giving a trapezoidal CE curve with a step at the end. Quantification of enantiomers is achieved according to the step height. The analysis does not rely on the use of enantiomerically pure chiral selector and the result agrees with that obtained by conventional chiral CE using a chiral selector.
Open AccessCopper (II) Ions Induced Self-Disproportionation of Enantiomers in Capillary Electrophoresis for the Quantification of Atenolol Enantiomers
Despite the fact that the self-disproportionation of enantiomers (SDE) has been found for several decades and has been widely used in crystallization, sublimation and chromatography for the purification or separation of nonracemic compounds, the phenomenon of SDE in capillary electrophoresis (CE) has never been reported up to now. Here, a new approach to separate enantiomers in CE based on SDE was demonstrated by introducing copper (II) ions into the separation media. The enantiomers of atenolol interact with copper ions to produce positively charged complexes with different electrophoretic mobilities from the single molecules. The dynamic equilibrium between homo- or heterochiral complexes (associates) and single molecules of atenolol enantiomers supports the manifestation of SDE. Different mobilities of the single molecules and associates, and different distribution of two enantiomers between the single molecules and associates caused by their different concentrations, produce a net difference in electrodriven migration velocities of the two enantiomers. The relative movement of two enantiomers causes a zone depleted in one enantiomer at the rear end of sample segment, giving a trapezoidal CE curve with a step at the end. Quantification of enantiomers is achieved according to the step height. The analysis does not rely on the use of enantiomerically pure chiral selector and the result agrees with that obtained by conventional chiral CE using a chiral selector.
- Open Access
Comparison of the Performance of Different Bile Salts in Enantioselective Separation of Palonosetron Stereoisomers by Micellar Electrokinetic Chromatography
Bile salts are a category of natural chiral surfactants which have ever been used as the surfactant and chiral selector for the separation of many chiral compounds by micellar electrokinetic chromatography (MEKC). In our previous works, the application of sodium cholate (SC) in the separation of four stereoisomers of palonosetron (PALO) by MEKC has been studied systematically. In this work, the parameters of other bile salts, including sodium taurocholate (STC), sodium deoxycholate (SDC), and sodium taurodeoxycholate (STDC) in the separation of PALO stereoisomers by MEKC were measured and compared with SC. It was found that all of four bile salts provide chiral recognition for both pairs of enantiomers, as well as achiral selectivity for diastereomers of different degrees. The structure of steroidal ring of bile salts has a greater impact on the separation than the structure of the side chain. The varying separation results by different bile salts were elucidated based on the measured parameters. A model to describe the contributions of the mobility difference of solutes in the aqueous phase and the selectivity of micelles to the chiral and achiral separation of stereoisomers was introduced. Additionally, a new approach to measure the mobility of micelles without enough solubility for hydrophobic markers was proposed, which is necessary for the calculation of separation parameters in MEKC. Under the guidance of derived equations, the separation by SDC and STDC was significantly improved by using lower surfactant concentrations. The complete separation of four stereoisomers was achieved in less than 3.5 min by using 4.0 mM of SDC. In addition, 30.0 mM of STC also provided the complete resolution of four stereoisomers due to the balance of different separation mechanisms. Its applicability for the analysis of a small amount of enantiomeric impurities in the presence of a high concentration of the effective ingredient was validated by a real sample.
Open AccessComparison of the Performance of Different Bile Salts in Enantioselective Separation of Palonosetron Stereoisomers by Micellar Electrokinetic Chromatography
Bile salts are a category of natural chiral surfactants which have ever been used as the surfactant and chiral selector for the separation of many chiral compounds by micellar electrokinetic chromatography (MEKC). In our previous works, the application of sodium cholate (SC) in the separation of four stereoisomers of palonosetron (PALO) by MEKC has been studied systematically. In this work, the parameters of other bile salts, including sodium taurocholate (STC), sodium deoxycholate (SDC), and sodium taurodeoxycholate (STDC) in the separation of PALO stereoisomers by MEKC were measured and compared with SC. It was found that all of four bile salts provide chiral recognition for both pairs of enantiomers, as well as achiral selectivity for diastereomers of different degrees. The structure of steroidal ring of bile salts has a greater impact on the separation than the structure of the side chain. The varying separation results by different bile salts were elucidated based on the measured parameters. A model to describe the contributions of the mobility difference of solutes in the aqueous phase and the selectivity of micelles to the chiral and achiral separation of stereoisomers was introduced. Additionally, a new approach to measure the mobility of micelles without enough solubility for hydrophobic markers was proposed, which is necessary for the calculation of separation parameters in MEKC. Under the guidance of derived equations, the separation by SDC and STDC was significantly improved by using lower surfactant concentrations. The complete separation of four stereoisomers was achieved in less than 3.5 min by using 4.0 mM of SDC. In addition, 30.0 mM of STC also provided the complete resolution of four stereoisomers due to the balance of different separation mechanisms. Its applicability for the analysis of a small amount of enantiomeric impurities in the presence of a high concentration of the effective ingredient was validated by a real sample.
- 11 October 2021
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 45 (43) , 20459-20467
The selectivity of a polydimethylsiloxane-based triblock copolymer as the stationary phase for capillary gas chromatography
A triblock copolymer (PCL-PDMS-PCL) constructed from polydimethylsiloxane (PDMS) and poly(ε-caprolactone) (PCL) chains was synthesized and used as the stationary phase for capillary gas chromatography (GC).
- 11 October 2021
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 45 (43) , 20459-20467
The selectivity of a polydimethylsiloxane-based triblock copolymer as the stationary phase for capillary gas chromatography
A triblock copolymer (PCL-PDMS-PCL) constructed from polydimethylsiloxane (PDMS) and poly(ε-caprolactone) (PCL) chains was synthesized and used as the stationary phase for capillary gas chromatography (GC).
- 1 September 2020
- Published by Elsevier in Microchemical Journal
- Vol. 157
Separation performance of p-nitro-octadecyloxy-calix[8]arene as stationary phases for capillary gas chromatography
- 1 September 2020
- Published by Elsevier in Microchemical Journal
- Vol. 157
Separation performance of p-nitro-octadecyloxy-calix[8]arene as stationary phases for capillary gas chromatography
- Open Access
- 25 November 2019
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 9 (66) , 38486-38495
Separation performance of p-tert -butyl(tetradecyloxy)calix[6]arene as a stationary phase for capillary gas chromatography
This work presents the first example of the utilization of p-tert-butyl(tetradecyloxy)calix[6]arene (C6A-C10) as a stationary phase for capillary gas chromatographic (GC) separation. The statically coated C6A-C10 column showed a column efficiency of 3293 plates per m and had a nonpolar nature. Its selectivity and retention behaviour were investigated using a number of mixtures of diverse analytes and their isomers. As a result, the C6A-C10 column exhibited high resolving capability for aliphatic and aromatic analytes from apolar to polar nature, especially for positional, structural and cis-/trans-isomers. Moreover, the C6A-C10 column showed thermal stability up to 240 °C. In addition, it was applied for the determination of isomer impurities in real samples, proving its good potential for practical GC analysis.
- 25 November 2019
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 9 (66) , 38486-38495
Open AccessSeparation performance of p-tert -butyl(tetradecyloxy)calix[6]arene as a stationary phase for capillary gas chromatography
This work presents the first example of the utilization of p-tert-butyl(tetradecyloxy)calix[6]arene (C6A-C10) as a stationary phase for capillary gas chromatographic (GC) separation. The statically coated C6A-C10 column showed a column efficiency of 3293 plates per m and had a nonpolar nature. Its selectivity and retention behaviour were investigated using a number of mixtures of diverse analytes and their isomers. As a result, the C6A-C10 column exhibited high resolving capability for aliphatic and aromatic analytes from apolar to polar nature, especially for positional, structural and cis-/trans-isomers. Moreover, the C6A-C10 column showed thermal stability up to 240 °C. In addition, it was applied for the determination of isomer impurities in real samples, proving its good potential for practical GC analysis.
- Open Access
Amphiphilic Block Copolymer PCL-PEG-PCL as Stationary Phase for Capillary Gas Chromatographic Separations
This work presents the first example of utilization of amphiphilic block copolymer PCL-PEG-PCL as a stationary phase for capillary gas chromatographic (GC) separations. The PCL-PEG-PCL capillary column fabricated by static coating provides a high column efficiency of 3951 plates/m for n-dodecane at 120 °C. McReynolds constants and Abraham system constants were also determined in order to evaluate the polarity and possible molecular interactions of the PCL-PEG-PCL stationary phase. Its selectivity and resolving capability were investigated by using a complex mixture covering analytes of diverse types and positional, structural, and cis-/trans-isomers. Impressively, it exhibits high resolution performance for aliphatic and aromatic isomers with diverse polarity, including those critical isomers such as butanol, dichlorobenzene, dimethylnaphthalene, xylenol, dichlorobenzaldehyde, and toluidine. Moreover, it was applied for the determination of isomer impurities in real samples, suggesting its potential for practical use. The superior separation performance demonstrates the potential of PCL-PEG-PCL and related block copolymers as stationary phases in GC and other separation technologies.
Open AccessAmphiphilic Block Copolymer PCL-PEG-PCL as Stationary Phase for Capillary Gas Chromatographic Separations
This work presents the first example of utilization of amphiphilic block copolymer PCL-PEG-PCL as a stationary phase for capillary gas chromatographic (GC) separations. The PCL-PEG-PCL capillary column fabricated by static coating provides a high column efficiency of 3951 plates/m for n-dodecane at 120 °C. McReynolds constants and Abraham system constants were also determined in order to evaluate the polarity and possible molecular interactions of the PCL-PEG-PCL stationary phase. Its selectivity and resolving capability were investigated by using a complex mixture covering analytes of diverse types and positional, structural, and cis-/trans-isomers. Impressively, it exhibits high resolution performance for aliphatic and aromatic isomers with diverse polarity, including those critical isomers such as butanol, dichlorobenzene, dimethylnaphthalene, xylenol, dichlorobenzaldehyde, and toluidine. Moreover, it was applied for the determination of isomer impurities in real samples, suggesting its potential for practical use. The superior separation performance demonstrates the potential of PCL-PEG-PCL and related block copolymers as stationary phases in GC and other separation technologies.