JeeEun Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
JeeEun Lee has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Sun Kook Yoo
Department of Medical Engineering, Yonsei University College of Medicine, Seoul, Korea
7 shared publications Sun K. Yoo
3 shared publications- Byeong-Nam Kim
Seoul, Korea (the Republic of) Korea (the Republic of)
1 shared publication - Dongmyung Park
Dyson School of Design Engineering, Imperial College London, London, UK
1 shared publication - Haksoo Han
Department of Chemical and Biomolecular Engineering, Yonsei University, Seoul, Korea
1 shared publication - Jinuk Kwon
Department of Chemical and Biomolecular Engineering Yonsei University 262 Seongsan‐no Seodaemun‐gu Seoul 120‐749 South Korea
1 shared publication
Latest Publications
- Open Access
- 10 August 2020
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 8 (8) , e17803
Respiration Rate Estimation Based on Independent Component Analysis of Accelerometer Data: Pilot Single-Arm Intervention Study
Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.
- 10 August 2020
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 8 (8) , e17803
Open AccessRespiration Rate Estimation Based on Independent Component Analysis of Accelerometer Data: Pilot Single-Arm Intervention Study
Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.
- Open Access
Radar-Based Detection of Respiration Rate with Adaptive Harmonic Quefrency Selection
Continuous respiration monitoring is important for predicting a potential disease. Due to respiration measurements using contact sensors, it is difficult to achieve continuous measurement because the sensors are inconvenient to attach. In this study, a radar sensor was used for non-contact respiration measurements. The radar sensor had a high precision and could even be used in the dark. It could also be used continuously regardless of time and place. The radar sensor relied on the periodicity of respiration to detect the respiration rate. A respiration adaptive interval was set and the respiration rate was detected through harmonic quefrency selection. As a result, it was confirmed that there was no difference between the respiratory rate measured using a respiration belt and the respiratory rate detected using a radar sensor. Furthermore, case studies on changes in the radar position and about measurement for long periods confirmed that the radar sensor could detect respiration rate continuously regardless of the position and measurement duration.
Open AccessRadar-Based Detection of Respiration Rate with Adaptive Harmonic Quefrency Selection
Continuous respiration monitoring is important for predicting a potential disease. Due to respiration measurements using contact sensors, it is difficult to achieve continuous measurement because the sensors are inconvenient to attach. In this study, a radar sensor was used for non-contact respiration measurements. The radar sensor had a high precision and could even be used in the dark. It could also be used continuously regardless of time and place. The radar sensor relied on the periodicity of respiration to detect the respiration rate. A respiration adaptive interval was set and the respiration rate was detected through harmonic quefrency selection. As a result, it was confirmed that there was no difference between the respiratory rate measured using a respiration belt and the respiratory rate detected using a radar sensor. Furthermore, case studies on changes in the radar position and about measurement for long periods confirmed that the radar sensor could detect respiration rate continuously regardless of the position and measurement duration.
- Open Access
- 3 February 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Respiration Rate Estimation Based on Independent Component Analysis of Accelerometer Data: Pilot Single-Arm Intervention Study (Preprint)
BACKGROUND As the mobile environment has developed recently, there have been studies on continuous respiration monitoring. However, it is not easy for general users to access the sensors typically used to measure respiration. There is also random noise caused by various environmental variables when respiration is measured using noncontact methods in a mobile environment. OBJECTIVE In this study, we aimed to estimate the respiration rate using an accelerometer sensor in a smartphone. METHODS First, data were acquired from an accelerometer sensor by a smartphone, which can easily be accessed by the general public. Second, an independent component was extracted to calibrate the three-axis accelerometer. Lastly, the respiration rate was estimated using quefrency selection reflecting the harmonic component because respiration has regular patterns. RESULTS From April 2018, we enrolled 30 male participants. When the independent component and quefrency selection were used to estimate the respiration rate, the correlation with respiration acquired from a chest belt was 0.7. The statistical results of the Wilcoxon signed-rank test were used to determine whether the differences in the respiration counts acquired from the chest belt and from the accelerometer sensor were significant. The P value of the difference in the respiration counts acquired from the two sensors was .27, which was not significant. This indicates that the number of respiration counts measured using the accelerometer sensor was not different from that measured using the chest belt. The Bland-Altman results indicated that the mean difference was 0.43, with less than one breath per minute, and that the respiration rate was at the 95% limits of agreement. CONCLUSIONS There was no relevant difference in the respiration rate measured using a chest belt and that measured using an accelerometer sensor. The accelerometer sensor approach could solve the problems related to the inconvenience of chest belt attachment and the settings. It could be used to detect sleep apnea through constant respiration rate estimation in an internet-of-things environment.
- 3 February 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessRespiration Rate Estimation Based on Independent Component Analysis of Accelerometer Data: Pilot Single-Arm Intervention Study (Preprint)
BACKGROUND As the mobile environment has developed recently, there have been studies on continuous respiration monitoring. However, it is not easy for general users to access the sensors typically used to measure respiration. There is also random noise caused by various environmental variables when respiration is measured using noncontact methods in a mobile environment. OBJECTIVE In this study, we aimed to estimate the respiration rate using an accelerometer sensor in a smartphone. METHODS First, data were acquired from an accelerometer sensor by a smartphone, which can easily be accessed by the general public. Second, an independent component was extracted to calibrate the three-axis accelerometer. Lastly, the respiration rate was estimated using quefrency selection reflecting the harmonic component because respiration has regular patterns. RESULTS From April 2018, we enrolled 30 male participants. When the independent component and quefrency selection were used to estimate the respiration rate, the correlation with respiration acquired from a chest belt was 0.7. The statistical results of the Wilcoxon signed-rank test were used to determine whether the differences in the respiration counts acquired from the chest belt and from the accelerometer sensor were significant. The P value of the difference in the respiration counts acquired from the two sensors was .27, which was not significant. This indicates that the number of respiration counts measured using the accelerometer sensor was not different from that measured using the chest belt. The Bland-Altman results indicated that the mean difference was 0.43, with less than one breath per minute, and that the respiration rate was at the 95% limits of agreement. CONCLUSIONS There was no relevant difference in the respiration rate measured using a chest belt and that measured using an accelerometer sensor. The accelerometer sensor approach could solve the problems related to the inconvenience of chest belt attachment and the settings. It could be used to detect sleep apnea through constant respiration rate estimation in an internet-of-things environment.
- Open Access
Recognition of Negative Emotion Using Long Short-Term Memory with Bio-Signal Feature Compression
Negative emotion is one reason why stress causes negative feedback. Therefore, many studies are being done to recognize negative emotions. However, emotion is difficult to classify because it is subjective and difficult to quantify. Moreover, emotion changes over time and is affected by mood. Therefore, we measured electrocardiogram (ECG), skin temperature (ST), and galvanic skin response (GSR) to detect objective indicators. We also compressed the features associated with emotion using a stacked auto-encoder (SAE). Finally, the compressed features and time information were used in training through long short-term memory (LSTM). As a result, the proposed LSTM used with the feature compression model showed the highest accuracy (99.4%) for recognizing negative emotions. The results of the suggested model were 11.3% higher than with a neural network (NN) and 5.6% higher than with SAE.
Open AccessRecognition of Negative Emotion Using Long Short-Term Memory with Bio-Signal Feature Compression
Negative emotion is one reason why stress causes negative feedback. Therefore, many studies are being done to recognize negative emotions. However, emotion is difficult to classify because it is subjective and difficult to quantify. Moreover, emotion changes over time and is affected by mood. Therefore, we measured electrocardiogram (ECG), skin temperature (ST), and galvanic skin response (GSR) to detect objective indicators. We also compressed the features associated with emotion using a stacked auto-encoder (SAE). Finally, the compressed features and time information were used in training through long short-term memory (LSTM). As a result, the proposed LSTM used with the feature compression model showed the highest accuracy (99.4%) for recognizing negative emotions. The results of the suggested model were 11.3% higher than with a neural network (NN) and 5.6% higher than with SAE.
- 21 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (5) , 1265-1275
Synthesis of Electrocardiogram V-Lead Signals From Limb-Lead Measurement Using R-Peak Aligned Generative Adversarial Network
Recently, portable electrocardiogram (ECG) hardware devices have been developed using limb-lead measurements. However, portable ECGs provide insufficient ECG information because of limitations in the number of leads and measurement positions. Therefore, in this study, V-lead ECG signals were synthesized from limb leads using an R-peak aligned generative adversarial network (GAN). The data used the Physikalisch-Technische Bundesanstalt (PTB) dataset provided by PhysioNet. First, R-peak alignment was performed to maintain the physiological information of the ECG. Second, time domain ECG was converted to bi-dimensional space by ordered time-sequence embedding. Finally, the GAN was learned through the pairs between the modified limb II (MLII) lead and each chest (V) lead. The result showed that the mean structural similarity index (SSIM) was 0.92, and the mean error rate of the percent mean square difference (PRD) of the chest leads was 7.21%.
- 21 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (5) , 1265-1275
Synthesis of Electrocardiogram V-Lead Signals From Limb-Lead Measurement Using R-Peak Aligned Generative Adversarial Network
Recently, portable electrocardiogram (ECG) hardware devices have been developed using limb-lead measurements. However, portable ECGs provide insufficient ECG information because of limitations in the number of leads and measurement positions. Therefore, in this study, V-lead ECG signals were synthesized from limb leads using an R-peak aligned generative adversarial network (GAN). The data used the Physikalisch-Technische Bundesanstalt (PTB) dataset provided by PhysioNet. First, R-peak alignment was performed to maintain the physiological information of the ECG. Second, time domain ECG was converted to bi-dimensional space by ordered time-sequence embedding. Finally, the GAN was learned through the pairs between the modified limb II (MLII) lead and each chest (V) lead. The result showed that the mean structural similarity index (SSIM) was 0.92, and the mean error rate of the percent mean square difference (PRD) of the chest leads was 7.21%.
- Open Access
Design of User-Customized Negative Emotion Classifier Based on Feature Selection Using Physiological Signal Sensors
First, the Likert scale and self-assessment manikin are used to provide emotion analogies, but they have limits for reflecting subjective factors. To solve this problem, we use physiological signals that show objective responses from cognitive status. The physiological signals used are electrocardiogram, skin temperature, and electrodermal activity (EDA). Second, the degree of emotion felt, and the related physiological signals, vary according to the individual. KLD calculates the difference in probability distribution shape patterns between two classes. Therefore, it is possible to analyze the relationship between physiological signals and emotion. As the result, features from EDA are important for distinguishing negative emotion in all subjects. In addition, the proposed feature selection algorithm showed an average accuracy of 92.5% and made it possible to improve the accuracy of negative emotion recognition.
Open AccessDesign of User-Customized Negative Emotion Classifier Based on Feature Selection Using Physiological Signal Sensors
First, the Likert scale and self-assessment manikin are used to provide emotion analogies, but they have limits for reflecting subjective factors. To solve this problem, we use physiological signals that show objective responses from cognitive status. The physiological signals used are electrocardiogram, skin temperature, and electrodermal activity (EDA). Second, the degree of emotion felt, and the related physiological signals, vary according to the individual. KLD calculates the difference in probability distribution shape patterns between two classes. Therefore, it is possible to analyze the relationship between physiological signals and emotion. As the result, features from EDA are important for distinguishing negative emotion in all subjects. In addition, the proposed feature selection algorithm showed an average accuracy of 92.5% and made it possible to improve the accuracy of negative emotion recognition.
- 14 March 2018
- Published by Springer Nature in Neurological Sciences
- Vol. 39 (8) , 1501-1502
Task-specific hand tremor during embouchure in a flutist
- 14 March 2018
- Published by Springer Nature in Neurological Sciences
- Vol. 39 (8) , 1501-1502
Task-specific hand tremor during embouchure in a flutist
- Open Access
- 1 September 2014
- Published by The Korean Institute of Electrical Engineers in The Transactions of The Korean Institute of Electrical Engineers
- Vol. 63 (9) , 1294-1299
Design of Hybrid Unsupervised-Supervised Classifier for Automatic Emotion Recognition
- 1 September 2014
- Published by The Korean Institute of Electrical Engineers in The Transactions of The Korean Institute of Electrical Engineers
- Vol. 63 (9) , 1294-1299
Open AccessDesign of Hybrid Unsupervised-Supervised Classifier for Automatic Emotion Recognition
- 25 January 2014
- Published by Wiley in Polymer Composites
- Vol. 35 (11) , 2214-2220
Fabrication of polyimide composite films based on carbon black for high‐temperature resistance
A novel high‐performance material, carbon black (CB) polyimide (PI), was obtained by the chemical synthesis of CB (carbon black N326) with PI. Following its synthesis, several analyses were carried out to investigate the thermal and mechanical properties of the newly synthesized CB‐PI. The thermal decomposition temperature of CB‐PI compared to PI increased by 76°C from 508 to 584°C. The glass transition temperature of CB‐PI as evaluated by differential scanning calorimetry increased by 204°C from 379 to 583°C compared to that of PI. Moreover, the mechanical strength of CB‐PI increased by 16% compared to that of PI. In addition, the analyses confirm that CB and PI in the synthesized CB‐PI were chemically crosslinked, which was shown to be responsible for the superior thermal and mechanical properties of the CB‐PI. POLYM. COMPOS., 35:2214–2220, 2014. © 2014 Society of Plastics Engineers
- 25 January 2014
- Published by Wiley in Polymer Composites
- Vol. 35 (11) , 2214-2220
Fabrication of polyimide composite films based on carbon black for high‐temperature resistance
A novel high‐performance material, carbon black (CB) polyimide (PI), was obtained by the chemical synthesis of CB (carbon black N326) with PI. Following its synthesis, several analyses were carried out to investigate the thermal and mechanical properties of the newly synthesized CB‐PI. The thermal decomposition temperature of CB‐PI compared to PI increased by 76°C from 508 to 584°C. The glass transition temperature of CB‐PI as evaluated by differential scanning calorimetry increased by 204°C from 379 to 583°C compared to that of PI. Moreover, the mechanical strength of CB‐PI increased by 16% compared to that of PI. In addition, the analyses confirm that CB and PI in the synthesized CB‐PI were chemically crosslinked, which was shown to be responsible for the superior thermal and mechanical properties of the CB‐PI. POLYM. COMPOS., 35:2214–2220, 2014. © 2014 Society of Plastics Engineers
- 25 December 2013
- Published by The Institute of Electronics Engineers of Korea in Journal of the Institute of Electronics and Information Engineers
- Vol. 50 (12) , 261-269
Enhancement of Evoked Potential Waveform using Delay-compensated Wiener Filtering
- 25 December 2013
- Published by The Institute of Electronics Engineers of Korea in Journal of the Institute of Electronics and Information Engineers
- Vol. 50 (12) , 261-269
Enhancement of Evoked Potential Waveform using Delay-compensated Wiener Filtering