Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michel Heninger has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • VOCs conversion in He/H2O plasma produced in a micro-capillary tube at atmospheric pressure

    by G Bauville, M Heninger, J Lemaire, P Jeanney, J Santos Sousa, A Pallandre, S Pasquiers

    A non-equilibrium plasma is created in a micro-capillary quartz tube (800 µm of internal diameter), by a DC-pulsed micro-dielectric barrier discharge (micro-DBD) and the propagation of an ionisation wave, in mixtures of He/H2O/VOC at atmospheric pressure where the studied volatile organic compounds (VOCs) are representative of molecules belonging to different chemical families: alcohols (methanol, ethanol, isopropanol, tert-butanol), ketones (acetone), nitriles (acetonitrile), and aromatic hydrocarbons (toluene). The conversion efficiency of these VOCs is studied as a function of the applied voltage on the micro-DBD (or electrical energy deposited in the plasma) and of the initial concentration of the molecules in the range from 1 ppm up to 3000 ppm (depending on the molecule), with the help of high-resolution real-time mass spectrometry Fourier transform ion cyclotron resonance associated to chemical ionisation (CI-FTICR) using H3O+ as precursor ion. A variety of by-products resulting from the conversion of VOCs are identified and quantified, emphasising that the micro-capillary plasma is able to induce a complex chemical reactivity. A qualitative analysis of the involved kinetics, based on the existing literature, reveals that helium species (ions and metastable states) and radicals coming from the dissociation of the water molecules (O and OH) are the most probable candidates to explain the formation of all compounds detected by the CI-FTICR apparatus. Quenching processes of the metastable He(23S) by the VOCs, leading to the dissociation of the molecules, are suggested to explain some of the experimental results.

  • Open Access

    Analysis of VOCs in Liquids through Vaporization in a Tubular Oven Monitored by Chemical Ionization Mass Spectrometry

    by Taous Abar, Hélène Mestdagh, Michel Heninger, Joel Lemaire

    The analysis of chemical compounds present at trace levels in liquids is important not only for environmental measurements but also, for example, in the health sector. The reference technique for the analysis of Volatile Organic Compounds (VOCs) in liquids is GC, which is difficult to use with an aqueous matrix. In this work, we present an alternative technique to GC to analyze VOCs in water. A tubular oven is used to completely vaporize the liquid sample deposited on a gauze. The oven is heated in the presence of a dinitrogen flow, and the gas is analyzed at the exit of the oven by a chemical ionization mass spectrometer developed in our laboratory. It is a low magnetic field Fourier Transform Ion Cyclotron Resonance (FT-ICR) optimized for real-time analysis. The Proton Transfer Reaction (PTR) used during the Chemical Ionization event results in the selective ionization of the VOCs present in the gas phase. The optimization of the desorption conditions is described for the main operating parameters: temperature ramp, liquid quantity, and nitrogen flow. Their influence is studied using a 100 ppmv aqueous toluene solution. The analytical method is then tested on a mixture of seven VOCs.


  • Open Access

    Monitoring of n-hexane degradation in a plasma reactor by chemical ionization mass spectrometry

    by Perla Trad, Nicole Blin-Simiand, Pascal Jeanney, Stéphane Pasquiers, Joel Lemaire, Essyllt Louarn, Hélène Mestdagh, Michel Heninger

    A DBD plasma is used to generate a multitude of by-products from the degradation of n-hexane molecules. The BTrap and other instruments follow n-hexane and organic by-products mixing ratios, allowing us to identify a large amount of molecules.


  • Direct and Real-Time Analysis in a Plasma Reactor Using a Compact FT-ICR MS: Degradation of Acetone in Nitrogen and Byproduct Formation

    by Sébastien Thomas, Nicole Blin-Simiand, Michel Héninger, Pascal Jeanney, Joel Lemaire, Lionel Magne, Hélène Mestdagh, Stéphane Pasquiers, Essyllt Louarn

    Methods for reduction of volatile organic compounds (VOCs) content in air depend on the application considered. For low concentration and low flux, nonthermal plasma methods are often considered as efficient. However, the complex chemistry involved is still not well understood because there is a lack of data sets of byproducts formation. To overcome this issue, rapid analytical methods are needed. We present the coupling of a rapid chemical ionization mass spectrometer (CIMS) for the real-time analysis of the VOCs formed during a degradation experiment. The high-resolution instrument used allows for chemical ionization and direct quantification of nontargeted compounds. This method is successfully applied to degradation experiments of acetone in a phototriggered nitrogen plasma discharge. Two regimes were highlighted: efficient conversion at low concentrations (100 ppm). Those two regimes were clearly delimited as the sum of two exponential curves occurring at respectively low and high concentrations. Many byproducts were detected; in particular, HCN presented a significantly high yield. Nitrile compounds (acetonitrile, propionitrile, ...) are formed as well. To a lower extent, ketene, acetaldehyde, and formaldehyde are observed. The association of the high-resolution mass spectrometer to the plasma reactor will allow further insights into the plasma chemistry and comparison to modelization.


  • Open Access

    Evidence of Reactivity in the Membrane for the Unstable Monochloramine during MIMS Analysis

    by Essyllt Louarn, Abdoul. Monem Asri-Idlibi, Julien Leprovost, Michel Héninger, Hélène Mestdagh

    Membrane Inlet Mass Spectrometry (MIMS) was used to analyze monochloramine solutions (NH2Cl) and ammonia solutions in a compact FTICR. Chemical ionization enables identification and quantification of the products present in the permeate. The responses of protonated monochloramine and ammonium increase linearly with the solution concentration. The enrichments were respectively 1.2 and 5.5. Pervaporation is dependent on pH and only the basic form of ammonia NH3 pervaporates through the membrane. Unexpectedly, the small ammonia molecule permeated very slowly. It could be due to interactions with water molecules inside the membrane that create clusters. Moreover, NH2Cl solutions, in addition to the NH3Cl+ signal, presented a strong NH4+ signal at m/z 18.034. Ammonia presence in the low-pressure zone before ionization is probable as NH4+ was detected with all the precursors used, particularly CF3+ and trimethylbenzene that presents a proton affinity higher than monochloramine. Ammonia may be formed inside the membrane due to the fact that NH2Cl is unstable and may react with the water present in the membrane. Those results highlight the need for caution when dealing with chloramines in MIMS and more generally with unstable molecules.


  • Open Access

    Evidence of Reactivity in the Membrane for the Unstable Monochloramine during MIMS Analysis

    by Essyllt Louarn, A. Monem Adli-Idlibi, Julien Leprovost, Michel Héninger, Hélène Mestdagh

    Membrane Inlet Mass Spectrometry (MIMS) was used to analyze monochloramine solutions (NH2Cl) and ammonia solutions in a compact FTICR. Chemical ionization enables identification and quantification of the products present in the permeate. The responses of protonated monochloramine and ammonium increase linearly with the solution concentration. The enrichments were respectively 1.2 and 5.5. Pervaporation is dependent on pH and only the basic form of ammonia NH3 pervaporates through the membrane. Unexpectedly, the small ammonia molecule permeated very slowly. It could be due to interactions with water molecules inside the membrane that create clusters. Moreover, NH2Cl solutions, in addition to the NH3Cl+ signal, presented a strong NH4+ signal at m/z 18.034 . Ammonia presence in the low-pressure zone before ionization is probable as NH4+ was detected with all the precursors used, particularly CF3+ and trimethylbenzene that presents a proton affinity higher than monochloramine. Ammonia may be formed inside the membrane due to the fact that NH2Cl is unstable and may react with the water present in the membrane. Those results highlight the need for caution when dealing with chloramines in MIMS and more generally with unstable molecules.


  • Real-time analysis of toluene removal in dry air by a dielectric barrier discharge using proton transfer reaction mass spectrometry

    by Stéphane Pasquiers, Michel Heninger, N Blin-Simiand, Joel Lemaire, Gerard Bauville, Blandine Bournonville, Essyllt Louarn, François Jorand, Hélène Mestdagh

    The proton transfer reaction mass spectrometry (PTR-MS) is used to follow the toluene concentration at the exit of a dielectric barrier discharge, for an inlet gas mixture of dry air with organic molecules at a concentration in the range 10–100 ppm, at atmospheric pressure and room temperature. The precursor ion is H 3 O + , and toluene is detected at mass 93 u, corresponding to the (C 6 H 5 CH 3 )–H + ion. The PTR-MS is used together with optical absorption spectroscopies to follow ozone and carbon dioxide molecules. Two different discharge regimes are studied: without or with significant self-warming effects. The PTR-MS diagnostic appears as a very useful tool for precise monitoring of the concentration of this organic molecule, and to get real-time information about the energy efficiency for the removal of the pollutant during the discharge operation, as function of the discharge regime.


  • Gas Analysis by Electron Ionization Combined with Chemical Ionization in a Compact FTICR Mass Spectrometer

    by Michel Heninger, Hélène Mestdagh, Essyllt Louarn, Gérard Mauclaire, Pierre Boissel, Julien Leprovost, Elsa Bauchard, Sébastien Thomas, Joël Lemaire

    In this paper, a compact Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer based on a permanent magnet is presented. This instrument has been developed for real-time analysis of gas emissions. The instrument is well suited to industrial applications or analysis of toxic and complex samples where the concentrations can vary rapidly on a wide range. The novelty of this instrument is the ability to use either electron ionization (EI) or chemical ionization (CI) individually or both of them alternatively. Also in CI mode, different precursor ions can be used alternatively. Volatile organic compounds (VOCs) from the ppb level to very high concentrations (% level) can be detected by CI or EI. The magnet is composed of three Halbach arrays, and the nominal field achieved is 1.5 T. The ICR cell is a 3 cm side length cubic cell. . The mass range is 12 to 200 u with a broad band detection. The mass accuracy of 0.005 u and the resolving power allow the separation of isobaric ions such as C3H7+ and CO2+. Gas introduction via controlled gas pulses, electron ionization, ion-molecule reactions, ion selection and detection are all performed in the ICR cell. The potential of the instrument will be illustrated by an analysis of a gas mixture containing trace components at ppm level (VOCs) and components in the 0.5-100% range (N2, alkanes, CO2).