ACAgata Czernuszewicz

Agata Czernuszewicz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Agata Czernuszewicz has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Bending-driven elastocaloric cooling enables efficient high-performance solid-state refrigeration

    by Tayfur Rahman Maruf, Asif Ahmed, Daniel Levick, Adrianna Johnson, Francisco Pereda, Stefan Ioana, Darin Sharar, Glen S. Bigelow, Lucas Griffith, Agata Czernuszewicz, et al.

  • Open Access

    Critical behavior and magnetocaloric effect in Laves-phase Tb1−xHoxNi2 (x = 0.25–0.75) solid solutions and composites

    by Jacek Ćwik, Yurii Koshkid'KO, Kiran Shinde, Ki Buem Kim, Agata Czernuszewicz

    The critical behavior around ferromagnetic–paramagnetic phase transition of polycrystalline Tb1−xHoxNi2 solid solutions (x = 0.25, 0.5, 0.75) was investigated using magnetization measurements in a magnetic field range of 0–5 T. The critical exponents obtained using the Kouvel–Fisher modified Arrott plot methods and the Widom scaling relation are consistent. The tricritical and 3D-Ising models adequately describe the samples, likely due to Ho substitution affecting the critical parameters. The spin interactions indicate long-range character in all studied compositions. Critical parameter analysis shows that the magnetic transition temperature decreases with the increasing Ho content, from 29.3 K for Tb0.75Ho0.25Ni2 to 17.1 K for Tb0.25Ho0.75Ni2. For the Tb0.5Ho0.5Ni2, direct measurements of adiabatic temperature change near the Curie temperature were performed in magnetic fields up to 14 T. The maximum ΔTad reaches ∼11 K near 26.3 K for μ0ΔH = 14 T. These results are compared with TbNi2 and HoNi2 and analyzed within the Landau theory of second-order phase transitions. To demonstrate application potential, composite materials based on Tb1−xHoxNi2 (x = 0.25–0.75) were proposed. Optimal molar ratios of Tb0.75Ho0.25Ni2, Tb0.5Ho0.5Ni2, and Tb0.25Ho0.75Ni2 were theoretically determined. The composites exhibit a nearly constant calculated magnetic entropy changes, ∼3.4 J/kg K for μ0ΔH = 1 T and ∼ 6.3 J/kg K for μ0ΔH = 2 T over a wide temperature range of 18–30 K. These results indicate that the proposed composites are promising candidates for use as refrigerants in low-temperature magnetic refrigerators.

  • Tailoring Nitinol for elastocaloric application

    by Agata Czernuszewicz, Alan R. Pelton, Matthew Carl, Julie Slaughter

  • Open Access

    From the Discovery of the Giant Magnetocaloric Effect to the Development of High‐Power‐Density Systems

    by Agata Czernuszewicz, Yaroslav Mudryk, Jun Cui, Lucas Griffith, Duane D. Johnson, Julie Slaughter

    Caloric cooling and heating promise an efficient and reliable alternative to ubiquitous vapor‐compression technology. In 1976, the very first near‐room‐temperature caloric system is developed, but it took another 20 years for this technology to fully bloom and gain global attention. The discovery of the giant magnetocaloric effect in Gd 5 Si 2 Ge 2 and the advance of the first long‐operating magnetic refrigerator, both in 1997, due to the Ames National Laboratory and Astronautics Corporation of America cooperation, are two milestones that sparked ongoing interest in caloric research, which continues to thrive to this day. This review presents a brief history of caloric heat pumping, from the discovery of the magnetocaloric effect to the most recent developments in materials and systems. The contributions of Ames National Laboratory of the U.S. Department of Energy are highlighted, celebrating its 30‐year anniversary in caloric research and paying tribute to two outstanding scientists, Vitalij K. Pecharsky and Karl A. Gschneidner, Jr., who inspired the caloric community for decades. The paper concludes with insights into remaining research and development challenges that must be addressed to enable the market transition of caloric technology and its widespread adoption.


  • Fighting the climate crisis with caloric heat pumping: Innovations to enable widespread adoption

    by Agata Czernuszewicz, Jun Cui, Duane D. Johnson, Lucas Griffith, Yaroslav Mudryk, Julie Slaughter


  • Magnetic and magnetocaloric properties of Dy1−xErxNi2 solid solutions and their promise for hydrogen liquefaction

    by Jacek Ćwik, Yurii Koshkid’kO, Kiran Shinde, Joonsik Park, Nilson Antunes de Oliveira, Michał Babij, Agata Czernuszewicz

    The ΔTad values are high and reach their maximum within a narrow temperature range below 20 K. This indicates that Dy1−xErxNi2 solid solutions may be a viable option for refrigerants in magnetic cryocoolers suitable for hydrogen liquefaction.


  • Open Access

    Rapid solidified ductile Cu-Al-Mn ribbon and its elastocaloric potential

    by Gaoyuan Ouyang, Chaochao Pan, Benjamin Hilliard, Agata Czernuszewicz, Julie Slaughter, Jun Cui

    Cu-Al-Mn alloys display martensitic transformation over a wide range of temperatures. In addition to low cost, this alloy is known for its low transformation stress with reasonable latent heat favoring elastocaloric applications. However, the ductility of Cu-Al-Mn can be limited owing to ordering and intergranular fracture. Through rapid solidification by melt spinning, we show that Cu-Al-Mn ribbon can be made highly ductile (greater than 8% tensile strain in the as-spun state and 10% tensile strain after heat treatment). The ductility of the melt-spun ribbon is related to the suppression of L21 ordering that is characterized through magnetic property measurement. Heat treatment of the ribbon promotes bamboo grain formation, and the latent heat is increased to 6.4 J g−1. Under tensile conditions, we show that the ribbon exhibited about 4 °C temperature change (4.4 °C on heating and 4.2 °C on cooling from 6.3% strain).


  • Open Access

    Balancing performance of active magnetic regenerators: a comprehensive experimental study of aspect ratio, particle size, and operating conditions

    by Agata Czernuszewicz, Lucas Griffith, Julie Slaughter, Vitalij Pecharsky

    Effective and, at the same time, efficient active magnetic regenerator (AMR) performance requires balanced geometry and operating conditions. Here the influence of regenerator shape, magnetocaloric material size, operating frequency, and utilization on the performance of gadolinium packed-particle bed AMRs is demonstrated experimentally. Various metrics are applied to assess effectiveness and efficiency. Observed temperature spans and cooling powers across a wide range of operating conditions are used to evaluate system performance and estimate exergetic cooling power and exergetic power quotient. A new metric combining exergetic cooling power and pump power provides an estimate of the maximum achievable second law efficiency. Five regenerator geometries with equal volumes and the aspect ratio from 1.0 to 3.8, and four different ranges of Gd spherical particles between 182 and 354 µm, are investigated. Improvements in system performance are demonstrated by a boost in specific cooling power of gadolinium from 0.85 to 1.16 W g−1 and maximum temperature span from 8.9 to 15.1 K. The optimum exergetic cooling power is observed for 1.37 utilization and 3 Hz operating frequency, exergetic power quotient exhibits a maximum at the same utilization but at 2 Hz frequency, while the highest efficiency is recorded at 1 Hz and utilization of 0.5, demonstrating that multiple performance metrics must be balanced to achieve regenerator design meeting all performance targets.


  • Low-force compressive and tensile actuation for elastocaloric heat pumps

    by Agata Czernuszewicz, Lucas Griffith, Julie Slaughter, Vitalij Pecharsky


  • Open Access

    Compact and efficient elastocaloric heat pumps—Is there a path forward?

    by Julie Slaughter, Agata Czernuszewicz, Lucas Griffith, Vitalij Pecharsky

    Elastocaloric cooling holds promise for energy-efficient heat pumping near room temperature with low environmental impact. Its adoption is, however, impeded by disproportionally large sizes of actuators compared with the active material volume. Taking magnetocaloric cooling as the baseline, the value of no more than 10:1 actuator volume to active material volume should lead to both size- and cost-effective solutions that may potentially be competitive with vapor-compression devices. With the goal to establish performance metrics that can lead to informed actuator selection for specific regenerator requirements, we analyze a wide range of elastocaloric materials and actuator technologies to find the best matches. We find that actuation with magnetic shape memory alloys meets all requirements; however, this technology is currently in early developmental stages and such actuators are not widely commercially available. Another promising and easily accessible option is standard rotary electric motors in combination with rotary-to-linear transduction mechanisms. A theoretical analysis of two case studies of elastocaloric systems using rotary electric motors with a Scotch yoke mechanism demonstrates the usefulness of our approach. Actuator requirements are based on two different regenerator configurations: one starting from zero strain without any mechanical energy recovery and another with 2% pre-strain and mechanical energy recovery to reduce the power and torque required from the motor. Our results indicate that the 10:1 target actuator to active material volume ratio can be met and feasibly lowered further, demonstrating that the proposed method for selecting actuators makes compact and efficient elastocaloric systems possible.