Lucas Griffith
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lucas Griffith has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Julie Slaughter
Ames National Laboratory U.S. Department of Energy Iowa State University Ames IA 50011 USA
8 shared publications - Agata Czernuszewicz
Ames National Laboratory, U.S. Department of Energy, Iowa State University, Ames, USA
6 shared publications - Vitalij K. Pecharsky
Ames Laboratory, U.S. Department of Energy, Iowa State University 1 , Ames, Iowa 50011, USA
4 shared publications - Charles W. Monroe
Department of Engineering Science, University of Oxford, Oxford, UK
3 shared publications Alice E.S. Sleightholme
†Department of Chemical Engineering, 2300 Hayward St., University of Michigan, Ann Arbor Michigan 48109, United States
2 shared publications- Duane D. Johnson
Division of Materials Science and Engineering, Ames National Laboratory, Ames, USA
2 shared publications
Latest Publications
- Open Access
- 25 June 2025
- Published by Wiley in Advanced Materials Technologies
- Vol. 11 (22)
From the Discovery of the Giant Magnetocaloric Effect to the Development of High‐Power‐Density Systems
Caloric cooling and heating promise an efficient and reliable alternative to ubiquitous vapor‐compression technology. In 1976, the very first near‐room‐temperature caloric system is developed, but it took another 20 years for this technology to fully bloom and gain global attention. The discovery of the giant magnetocaloric effect in Gd 5 Si 2 Ge 2 and the advance of the first long‐operating magnetic refrigerator, both in 1997, due to the Ames National Laboratory and Astronautics Corporation of America cooperation, are two milestones that sparked ongoing interest in caloric research, which continues to thrive to this day. This review presents a brief history of caloric heat pumping, from the discovery of the magnetocaloric effect to the most recent developments in materials and systems. The contributions of Ames National Laboratory of the U.S. Department of Energy are highlighted, celebrating its 30‐year anniversary in caloric research and paying tribute to two outstanding scientists, Vitalij K. Pecharsky and Karl A. Gschneidner, Jr., who inspired the caloric community for decades. The paper concludes with insights into remaining research and development challenges that must be addressed to enable the market transition of caloric technology and its widespread adoption.
- 25 June 2025
- Published by Wiley in Advanced Materials Technologies
- Vol. 11 (22)
Open AccessFrom the Discovery of the Giant Magnetocaloric Effect to the Development of High‐Power‐Density Systems
Caloric cooling and heating promise an efficient and reliable alternative to ubiquitous vapor‐compression technology. In 1976, the very first near‐room‐temperature caloric system is developed, but it took another 20 years for this technology to fully bloom and gain global attention. The discovery of the giant magnetocaloric effect in Gd 5 Si 2 Ge 2 and the advance of the first long‐operating magnetic refrigerator, both in 1997, due to the Ames National Laboratory and Astronautics Corporation of America cooperation, are two milestones that sparked ongoing interest in caloric research, which continues to thrive to this day. This review presents a brief history of caloric heat pumping, from the discovery of the magnetocaloric effect to the most recent developments in materials and systems. The contributions of Ames National Laboratory of the U.S. Department of Energy are highlighted, celebrating its 30‐year anniversary in caloric research and paying tribute to two outstanding scientists, Vitalij K. Pecharsky and Karl A. Gschneidner, Jr., who inspired the caloric community for decades. The paper concludes with insights into remaining research and development challenges that must be addressed to enable the market transition of caloric technology and its widespread adoption.
- 15 November 2024
- Published by Springer Nature in MRS Energy & Sustainability
- Vol. 12 (1) , 23-31
Fighting the climate crisis with caloric heat pumping: Innovations to enable widespread adoption
- 15 November 2024
- Published by Springer Nature in MRS Energy & Sustainability
- Vol. 12 (1) , 23-31
Fighting the climate crisis with caloric heat pumping: Innovations to enable widespread adoption
- Open Access
- 15 March 2023
- Published by IOP Publishing in Journal of Physics: Energy
- Vol. 5 (2) , 024008
Balancing performance of active magnetic regenerators: a comprehensive experimental study of aspect ratio, particle size, and operating conditions
Effective and, at the same time, efficient active magnetic regenerator (AMR) performance requires balanced geometry and operating conditions. Here the influence of regenerator shape, magnetocaloric material size, operating frequency, and utilization on the performance of gadolinium packed-particle bed AMRs is demonstrated experimentally. Various metrics are applied to assess effectiveness and efficiency. Observed temperature spans and cooling powers across a wide range of operating conditions are used to evaluate system performance and estimate exergetic cooling power and exergetic power quotient. A new metric combining exergetic cooling power and pump power provides an estimate of the maximum achievable second law efficiency. Five regenerator geometries with equal volumes and the aspect ratio from 1.0 to 3.8, and four different ranges of Gd spherical particles between 182 and 354 µm, are investigated. Improvements in system performance are demonstrated by a boost in specific cooling power of gadolinium from 0.85 to 1.16 W g−1 and maximum temperature span from 8.9 to 15.1 K. The optimum exergetic cooling power is observed for 1.37 utilization and 3 Hz operating frequency, exergetic power quotient exhibits a maximum at the same utilization but at 2 Hz frequency, while the highest efficiency is recorded at 1 Hz and utilization of 0.5, demonstrating that multiple performance metrics must be balanced to achieve regenerator design meeting all performance targets.
- 15 March 2023
- Published by IOP Publishing in Journal of Physics: Energy
- Vol. 5 (2) , 024008
Open AccessBalancing performance of active magnetic regenerators: a comprehensive experimental study of aspect ratio, particle size, and operating conditions
Effective and, at the same time, efficient active magnetic regenerator (AMR) performance requires balanced geometry and operating conditions. Here the influence of regenerator shape, magnetocaloric material size, operating frequency, and utilization on the performance of gadolinium packed-particle bed AMRs is demonstrated experimentally. Various metrics are applied to assess effectiveness and efficiency. Observed temperature spans and cooling powers across a wide range of operating conditions are used to evaluate system performance and estimate exergetic cooling power and exergetic power quotient. A new metric combining exergetic cooling power and pump power provides an estimate of the maximum achievable second law efficiency. Five regenerator geometries with equal volumes and the aspect ratio from 1.0 to 3.8, and four different ranges of Gd spherical particles between 182 and 354 µm, are investigated. Improvements in system performance are demonstrated by a boost in specific cooling power of gadolinium from 0.85 to 1.16 W g−1 and maximum temperature span from 8.9 to 15.1 K. The optimum exergetic cooling power is observed for 1.37 utilization and 3 Hz operating frequency, exergetic power quotient exhibits a maximum at the same utilization but at 2 Hz frequency, while the highest efficiency is recorded at 1 Hz and utilization of 0.5, demonstrating that multiple performance metrics must be balanced to achieve regenerator design meeting all performance targets.
- 1 September 2021
- Published by Elsevier in Acta Materialia
- Vol. 217
Toward efficient elastocaloric systems: Predicting material thermal properties with high fidelity
- 1 September 2021
- Published by Elsevier in Acta Materialia
- Vol. 217
Toward efficient elastocaloric systems: Predicting material thermal properties with high fidelity
- Open Access
- 2 November 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (11) , e0241620
Comparison of heart rate obtained from shorter duration Holter recordings to 24-hour mean heart rate in dogs with atrial fibrillation
The objective of this study was to evaluate the accuracy of short duration electrocardiographic (ECG) recordings extracted from ambulatory continuous ECG (Holter) to assess 24-hour mean heart rate in dogs with atrial fibrillation. In this retrospective study, Holter recordings obtained from 20 dogs with atrial fibrillation were selected for analysis. Ten out of 20 dogs were receiving drugs to control heart rate at the time of Holter evaluation. From the Holter recordings, heart rate averages were calculated for various sample durations (five-minutes, 30 minutes, one-hour, two-hours, and three-hours) for each dog. Percentage of these shorter duration ECG obtained HR averages that fell within ±10%, ±15% and ± 20% of 24-hour mean heart rate was determined for each sample duration and for each dog. Seventy five percent of heart rate averages obtained from three-hour ECG recordings fell within ±10% of 24-hour mean HR. All the heart rate averages obtained from two-hour ECG recordings fell within ±20% of 24-hour mean heart rate. Based on the results of this study it can be concluded that the duration of the ECG recording affects the prediction accuracy for 24-hour Holter mean HR. Only two and three hours of Holter recordings provided all heart rate averages within ±20% of 24-hour mean heart rate. No significant differences were noted in the prediction accuracy of shorter duration ECG recordings based on rate control therapy status. Further prospective studies are needed to assess the accuracy of HR obtained at home using various ECG recording devices to predict 24-hour mean heart rate in dogs with atrial fibrillation.
- 2 November 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (11) , e0241620
Open AccessComparison of heart rate obtained from shorter duration Holter recordings to 24-hour mean heart rate in dogs with atrial fibrillation
The objective of this study was to evaluate the accuracy of short duration electrocardiographic (ECG) recordings extracted from ambulatory continuous ECG (Holter) to assess 24-hour mean heart rate in dogs with atrial fibrillation. In this retrospective study, Holter recordings obtained from 20 dogs with atrial fibrillation were selected for analysis. Ten out of 20 dogs were receiving drugs to control heart rate at the time of Holter evaluation. From the Holter recordings, heart rate averages were calculated for various sample durations (five-minutes, 30 minutes, one-hour, two-hours, and three-hours) for each dog. Percentage of these shorter duration ECG obtained HR averages that fell within ±10%, ±15% and ± 20% of 24-hour mean heart rate was determined for each sample duration and for each dog. Seventy five percent of heart rate averages obtained from three-hour ECG recordings fell within ±10% of 24-hour mean HR. All the heart rate averages obtained from two-hour ECG recordings fell within ±20% of 24-hour mean heart rate. Based on the results of this study it can be concluded that the duration of the ECG recording affects the prediction accuracy for 24-hour Holter mean HR. Only two and three hours of Holter recordings provided all heart rate averages within ±20% of 24-hour mean heart rate. No significant differences were noted in the prediction accuracy of shorter duration ECG recordings based on rate control therapy status. Further prospective studies are needed to assess the accuracy of HR obtained at home using various ECG recording devices to predict 24-hour mean heart rate in dogs with atrial fibrillation.
- 1 June 2020
- Published by Elsevier in Applied Materials Today
- Vol. 19
Low-force compressive and tensile actuation for elastocaloric heat pumps
- 1 June 2020
- Published by Elsevier in Applied Materials Today
- Vol. 19
Low-force compressive and tensile actuation for elastocaloric heat pumps
- Open Access
- 19 May 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 127 (19) , 194501
Compact and efficient elastocaloric heat pumps—Is there a path forward?
Elastocaloric cooling holds promise for energy-efficient heat pumping near room temperature with low environmental impact. Its adoption is, however, impeded by disproportionally large sizes of actuators compared with the active material volume. Taking magnetocaloric cooling as the baseline, the value of no more than 10:1 actuator volume to active material volume should lead to both size- and cost-effective solutions that may potentially be competitive with vapor-compression devices. With the goal to establish performance metrics that can lead to informed actuator selection for specific regenerator requirements, we analyze a wide range of elastocaloric materials and actuator technologies to find the best matches. We find that actuation with magnetic shape memory alloys meets all requirements; however, this technology is currently in early developmental stages and such actuators are not widely commercially available. Another promising and easily accessible option is standard rotary electric motors in combination with rotary-to-linear transduction mechanisms. A theoretical analysis of two case studies of elastocaloric systems using rotary electric motors with a Scotch yoke mechanism demonstrates the usefulness of our approach. Actuator requirements are based on two different regenerator configurations: one starting from zero strain without any mechanical energy recovery and another with 2% pre-strain and mechanical energy recovery to reduce the power and torque required from the motor. Our results indicate that the 10:1 target actuator to active material volume ratio can be met and feasibly lowered further, demonstrating that the proposed method for selecting actuators makes compact and efficient elastocaloric systems possible.
- 19 May 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 127 (19) , 194501
Open AccessCompact and efficient elastocaloric heat pumps—Is there a path forward?
Elastocaloric cooling holds promise for energy-efficient heat pumping near room temperature with low environmental impact. Its adoption is, however, impeded by disproportionally large sizes of actuators compared with the active material volume. Taking magnetocaloric cooling as the baseline, the value of no more than 10:1 actuator volume to active material volume should lead to both size- and cost-effective solutions that may potentially be competitive with vapor-compression devices. With the goal to establish performance metrics that can lead to informed actuator selection for specific regenerator requirements, we analyze a wide range of elastocaloric materials and actuator technologies to find the best matches. We find that actuation with magnetic shape memory alloys meets all requirements; however, this technology is currently in early developmental stages and such actuators are not widely commercially available. Another promising and easily accessible option is standard rotary electric motors in combination with rotary-to-linear transduction mechanisms. A theoretical analysis of two case studies of elastocaloric systems using rotary electric motors with a Scotch yoke mechanism demonstrates the usefulness of our approach. Actuator requirements are based on two different regenerator configurations: one starting from zero strain without any mechanical energy recovery and another with 2% pre-strain and mechanical energy recovery to reduce the power and torque required from the motor. Our results indicate that the 10:1 target actuator to active material volume ratio can be met and feasibly lowered further, demonstrating that the proposed method for selecting actuators makes compact and efficient elastocaloric systems possible.
- 1 November 2019
- Published by Elsevier in Energy Conversion and Management
- Vol. 199
CaloriSMART: Small-scale test-stand for rapid evaluation of active magnetic regenerator performance
- 1 November 2019
- Published by Elsevier in Energy Conversion and Management
- Vol. 199
CaloriSMART: Small-scale test-stand for rapid evaluation of active magnetic regenerator performance
- Top Cited Papers
- 16 January 2018
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 123 (3)
Material-based figure of merit for caloric materials
The efficient use of reversible thermal effects in magnetocaloric, electrocaloric, and elastocaloric materials is a promising avenue that can lead to a substantially increased efficiency of refrigeration and heat pumping devices, most importantly, those used in household and commercial cooling applications near ambient temperature. A proliferation in caloric material research has resulted in a wide array of materials where only the isothermal change in entropy in response to a handful of different field strengths over a limited range of temperatures has been evaluated and reported. Given the abundance of such data, there is a clear need for a simple and reliable figure of merit enabling fast screening and down-selection to justify further detailed characterization of those material systems that hold the greatest promise. Based on the analysis of several well-known materials that exhibit vastly different magnetocaloric effects, the Temperature averaged Entropy Change is introduced as a suitable early indicator of the material's utility for magnetocaloric cooling applications, and its adoption by the caloric community is recommended.
- 16 January 2018
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 123 (3)
Top Cited PapersMaterial-based figure of merit for caloric materials
The efficient use of reversible thermal effects in magnetocaloric, electrocaloric, and elastocaloric materials is a promising avenue that can lead to a substantially increased efficiency of refrigeration and heat pumping devices, most importantly, those used in household and commercial cooling applications near ambient temperature. A proliferation in caloric material research has resulted in a wide array of materials where only the isothermal change in entropy in response to a handful of different field strengths over a limited range of temperatures has been evaluated and reported. Given the abundance of such data, there is a clear need for a simple and reliable figure of merit enabling fast screening and down-selection to justify further detailed characterization of those material systems that hold the greatest promise. Based on the analysis of several well-known materials that exhibit vastly different magnetocaloric effects, the Temperature averaged Entropy Change is introduced as a suitable early indicator of the material's utility for magnetocaloric cooling applications, and its adoption by the caloric community is recommended.
- 16 March 2015
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 7 (14) , 7670-7678
Correlating Li/O2 Cell Capacity and Product Morphology with Discharge Current
The discharge rate is critical to the performance of lithium/oxygen batteries: it impacts both cell capacity and discharge-phase morphology, and in so doing may also affect the efficiency of the oxygen-evolution reaction during recharging. First-discharge data from tens of Li/O2 cells discharged across four rates are analyzed statistically to inform these connections. In the practically significant superficial current-density range of 0.1 to 1 mA cm–2, capacity is found to fall as a power law, with a Peukert’s-law exponent of 1.6 ± 0.1. X-ray diffractometry confirms the dominant presence of crystalline Li2O2 in the discharged electrodes. A completely air-free sample-transfer technique was developed to implement scanning electron microscopy (SEM) of the discharge product. SEM imaging of electrodes with near-average capacities provides statistically significant measures of the shape and size variation of electrodeposited Li2O2 particles with respect to discharge current. At lower rates, typical “toroidal” particles are observed that are well approximated as cylindrical structures, whose average radii remain relatively constant as discharge rate increases, whereas their average heights decrease. At the highest rate studied, air-free SEM shows that particles take needle-like shapes rather than forming the nanosheets or compact films described elsewhere. Average particle volumes decrease with current while particle surface-to-volume ratios increase dramatically, supporting the notion that Li2O2 grows by a locally mass-transfer-limited nucleation and growth mechanism.
- 16 March 2015
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 7 (14) , 7670-7678
Correlating Li/O2 Cell Capacity and Product Morphology with Discharge Current
The discharge rate is critical to the performance of lithium/oxygen batteries: it impacts both cell capacity and discharge-phase morphology, and in so doing may also affect the efficiency of the oxygen-evolution reaction during recharging. First-discharge data from tens of Li/O2 cells discharged across four rates are analyzed statistically to inform these connections. In the practically significant superficial current-density range of 0.1 to 1 mA cm–2, capacity is found to fall as a power law, with a Peukert’s-law exponent of 1.6 ± 0.1. X-ray diffractometry confirms the dominant presence of crystalline Li2O2 in the discharged electrodes. A completely air-free sample-transfer technique was developed to implement scanning electron microscopy (SEM) of the discharge product. SEM imaging of electrodes with near-average capacities provides statistically significant measures of the shape and size variation of electrodeposited Li2O2 particles with respect to discharge current. At lower rates, typical “toroidal” particles are observed that are well approximated as cylindrical structures, whose average radii remain relatively constant as discharge rate increases, whereas their average heights decrease. At the highest rate studied, air-free SEM shows that particles take needle-like shapes rather than forming the nanosheets or compact films described elsewhere. Average particle volumes decrease with current while particle surface-to-volume ratios increase dramatically, supporting the notion that Li2O2 grows by a locally mass-transfer-limited nucleation and growth mechanism.