Jeong-Woong Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jeong-Woong Lee has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Eunsol Go
4 shared publicationsHyojin Jeon
4 shared publications- Sora Park
Intelligent Components and Sensors Research Section, Electronics and Telecommunications Research Institute (ETRI), 218 Gajeong-ro, Yuseong-gu, Daejeon 34129, Korea
4 shared publications Jae-Woo Kim
Emerging Device Research Group, Electronics and Telecommunications Research Institute, Daejeon 34129, Korea
3 shared publicationsJi-Hwan Yeon
Emerging Device Research Group, Electronics and Telecommunications Research Institute, Daejeon 34129, Korea
3 shared publications- Jun-Tae Kang
Electronics and Telecommunications Research Institute (Korea, Republic of)
3 shared publications
Latest Publications
- Open Access
- 1 October 2025
- Published by IOP Publishing in Metrologia
- Vol. 62 (5) , 055007
Quantifying the stability of the probe current of scanning electron microscopes
Probe current stability in a scanning electron microscopy (SEM) is a critical factor related to the realization of high-resolution imaging and accurate nanoscale metrology, including critical dimension measurements and depth estimations. While prior research has predominantly focused on noise sources and long-term drift, systematic quantifications of sensitivity coefficients and measurement uncertainties across various electron gun configurations remain insufficient. Without a clear understanding of how structural parameters such as the tip radius and extractor gap affect probe current stability, optimizing electron sources for advanced metrology continues to be a challenge. Moreover, the lack of experimental validation hinders reliable uncertainty analyses. In this study, we evaluate both short-term and long-term probe current stability levels for thermal field emission and cold field emission sources using Allan deviation and autocorrelation function analyses. Sensitivity coefficients with respect to the extraction voltage are systematically simulated over a range of tip radius and extractor gap distances, revealing direct correlations between geometric design parameters and current stability levels. Experimental measurements are combined with simulation results to quantify the combined standard uncertainty and expanded uncertainty of the probe current for various electron gun configurations. These results establish a clear correlation between emission structure parameters and probe current variations, providing a practical basis for the optimization of electron-optical systems in SEM applications for improved stability and metrology performance outcomes.
- 1 October 2025
- Published by IOP Publishing in Metrologia
- Vol. 62 (5) , 055007
Open AccessQuantifying the stability of the probe current of scanning electron microscopes
Probe current stability in a scanning electron microscopy (SEM) is a critical factor related to the realization of high-resolution imaging and accurate nanoscale metrology, including critical dimension measurements and depth estimations. While prior research has predominantly focused on noise sources and long-term drift, systematic quantifications of sensitivity coefficients and measurement uncertainties across various electron gun configurations remain insufficient. Without a clear understanding of how structural parameters such as the tip radius and extractor gap affect probe current stability, optimizing electron sources for advanced metrology continues to be a challenge. Moreover, the lack of experimental validation hinders reliable uncertainty analyses. In this study, we evaluate both short-term and long-term probe current stability levels for thermal field emission and cold field emission sources using Allan deviation and autocorrelation function analyses. Sensitivity coefficients with respect to the extraction voltage are systematically simulated over a range of tip radius and extractor gap distances, revealing direct correlations between geometric design parameters and current stability levels. Experimental measurements are combined with simulation results to quantify the combined standard uncertainty and expanded uncertainty of the probe current for various electron gun configurations. These results establish a clear correlation between emission structure parameters and probe current variations, providing a practical basis for the optimization of electron-optical systems in SEM applications for improved stability and metrology performance outcomes.
- 23 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 67 (3) , 1192-1197
Stabilized and Equalized Field-Emission Currents From Carbon Nanotube Emitters by Cascade Active-Current-Control
- 23 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 67 (3) , 1192-1197
Stabilized and Equalized Field-Emission Currents From Carbon Nanotube Emitters by Cascade Active-Current-Control
- 4 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 39 (12) , 1936-1939
A Fully Closed Nano-Focus X-Ray Source With Carbon Nanotube Field Emitters
We developed a fully closed nano-focus x-ray source using carbon nanotube (CNT) field emitters. The nano-focus x-ray source includes a fully vacuum-sealed CNT Electron-gun (E-gun) tube and E-beam-focusing modules consisting of electrostatic and magnetic lenses, facilitating very compact and high-resolution x-ray imaging. The paste-printed CNT emitters were prepared in a small pattern as an electron source, and the entire components including the CNT emitter module, Cu tubes, collimators, and transmissive anode target were specially brazed at an elevated temperature, resulting in a very compact E-gun tube. The CNT emitter showed a stable and reliable emission current with its density of over 300 mA/cm2 even in the vacuum-sealed E-gun tube. With the anode grounded and the CNT emitter module biased to negative high voltages, we achieved a considerably magnified x-ray image of a several hundred nanometer resolution. The fully vacuum-sealed CNT E-gun tube along with the magnetic lens module can offer much more compact, easily maintainable, high-resolution x-ray imaging compared with conventional open-type thermionic x-ray sources.
- 4 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 39 (12) , 1936-1939
A Fully Closed Nano-Focus X-Ray Source With Carbon Nanotube Field Emitters
We developed a fully closed nano-focus x-ray source using carbon nanotube (CNT) field emitters. The nano-focus x-ray source includes a fully vacuum-sealed CNT Electron-gun (E-gun) tube and E-beam-focusing modules consisting of electrostatic and magnetic lenses, facilitating very compact and high-resolution x-ray imaging. The paste-printed CNT emitters were prepared in a small pattern as an electron source, and the entire components including the CNT emitter module, Cu tubes, collimators, and transmissive anode target were specially brazed at an elevated temperature, resulting in a very compact E-gun tube. The CNT emitter showed a stable and reliable emission current with its density of over 300 mA/cm2 even in the vacuum-sealed E-gun tube. With the anode grounded and the CNT emitter module biased to negative high voltages, we achieved a considerably magnified x-ray image of a several hundred nanometer resolution. The fully vacuum-sealed CNT E-gun tube along with the magnetic lens module can offer much more compact, easily maintainable, high-resolution x-ray imaging compared with conventional open-type thermionic x-ray sources.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Two applications of carbon nanotube paste emitters: nano-focus, and high-flux vacuum-sealed x-ray tubes
The printed carbon nanotube (CNT) paste emitters were applied to two types of vacuum-sealed x-ray tubes for several hundred-nanometer-resolution non-destructive testing (NDT) and cone-beam breast computed tomography (CB-BCT) applications. A single dot CNT emitter of 200 micrometer in diameter was made for a small focal spot size of NDT imaging meanwhile a 983-dots array was for a high current of CB-BCT imaging. The electron beam emitted from the single dot emitter in the nano-focus x-ray tube is strongly focused to a small focal spot size of 1 micrometer or less in diameter by help of electrostatic and magnetic focusing lenses, and the 983 emitters produce a large field emission current over 200 mA with a moderate focal spot, tentatively applicable to CB-BCT imaging. The printed CNT emitters can be used for a variety of electron sources from several hundred-nanometer focusing to high-flux xray tubes.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Two applications of carbon nanotube paste emitters: nano-focus, and high-flux vacuum-sealed x-ray tubes
The printed carbon nanotube (CNT) paste emitters were applied to two types of vacuum-sealed x-ray tubes for several hundred-nanometer-resolution non-destructive testing (NDT) and cone-beam breast computed tomography (CB-BCT) applications. A single dot CNT emitter of 200 micrometer in diameter was made for a small focal spot size of NDT imaging meanwhile a 983-dots array was for a high current of CB-BCT imaging. The electron beam emitted from the single dot emitter in the nano-focus x-ray tube is strongly focused to a small focal spot size of 1 micrometer or less in diameter by help of electrostatic and magnetic focusing lenses, and the 983 emitters produce a large field emission current over 200 mA with a moderate focal spot, tentatively applicable to CB-BCT imaging. The printed CNT emitters can be used for a variety of electron sources from several hundred-nanometer focusing to high-flux xray tubes.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 154-155
Optimization of carbon nanotube paste emitter by controlling the size distribution of SiC nanofiller aggregates
We tried to improve field emission properties of carbon nanotube (CNT) paste emitters by controlling the size distribution of aggregated SiC fillers. The SiC fillers used as an adhesion promoter strongly affects the dispersion of CNT paste, determining uniformity and reproducibility of the field emitter. We found, to date, that the optimum distribution is about 1 μm of D50, the value of the particle diameter at 50% in cumulative distribution. The CNT emitters with the optimized paste showed uniform and reproducible emission performances along with high adhesion to the cathode. The improved paste formulation and emitter fabrication could lead to successful field emission devices and applications.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 154-155
Optimization of carbon nanotube paste emitter by controlling the size distribution of SiC nanofiller aggregates
We tried to improve field emission properties of carbon nanotube (CNT) paste emitters by controlling the size distribution of aggregated SiC fillers. The SiC fillers used as an adhesion promoter strongly affects the dispersion of CNT paste, determining uniformity and reproducibility of the field emitter. We found, to date, that the optimum distribution is about 1 μm of D50, the value of the particle diameter at 50% in cumulative distribution. The CNT emitters with the optimized paste showed uniform and reproducible emission performances along with high adhesion to the cathode. The improved paste formulation and emitter fabrication could lead to successful field emission devices and applications.
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 5192-5195
A Wearable Context Aware System for Ubiquitous Healthcare
Recent developments of information technologies are leading the advent of the era of ubiquitous healthcare, which means healthcare services at any time and at any places. The ubiquitous healthcare service needs a wearable system for more continual measurement of biological signals of a user, which gives information of the user from wearable sensors. In this paper, we propose a wearable context aware system for ubiquitous healthcare, and its systematic design process of a ubiquitous healthcare service. Some wearable sensor systems are introduced with Zigbee communication. We develop a context aware framework to send information from wearable sensors to healthcare service entities as a middleware to solve the interoperability problem between sensor makers and healthcare service providers. And, we propose a systematic process of design of ubiquitous healthcare services with the context aware framework. In order to show the feasibility of the proposed system, some application examples are given, which are applied to remote monitoring, and a self check service
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 5192-5195
A Wearable Context Aware System for Ubiquitous Healthcare
Recent developments of information technologies are leading the advent of the era of ubiquitous healthcare, which means healthcare services at any time and at any places. The ubiquitous healthcare service needs a wearable system for more continual measurement of biological signals of a user, which gives information of the user from wearable sensors. In this paper, we propose a wearable context aware system for ubiquitous healthcare, and its systematic design process of a ubiquitous healthcare service. Some wearable sensor systems are introduced with Zigbee communication. We develop a context aware framework to send information from wearable sensors to healthcare service entities as a middleware to solve the interoperability problem between sensor makers and healthcare service providers. And, we propose a systematic process of design of ubiquitous healthcare services with the context aware framework. In order to show the feasibility of the proposed system, some application examples are given, which are applied to remote monitoring, and a self check service
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 5192-5195
A Wearable Context Aware System for Ubiquitous Healthcare
Recent developments of information technologies are leading the advent of the era of ubiquitous healthcare, which means healthcare services at any time and at any places. The ubiquitous healthcare service needs a wearable system for more continual measurement of biological signals of a user, which gives information of the user from wearable sensors. In this paper, we propose a wearable context aware system for ubiquitous healthcare, and its systematic design process of a ubiquitous healthcare service. Some wearable sensor systems are introduced with Zigbee communication. We develop a context aware framework to send information from wearable sensors to healthcare service entities as a middleware to solve the interoperability problem between sensor makers and healthcare service providers. And, we propose a systematic process of design of ubiquitous healthcare services with the context aware framework. In order to show the feasibility of the proposed system, some application examples are given, which are applied to remote monitoring, and a self check service
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 5192-5195
A Wearable Context Aware System for Ubiquitous Healthcare
Recent developments of information technologies are leading the advent of the era of ubiquitous healthcare, which means healthcare services at any time and at any places. The ubiquitous healthcare service needs a wearable system for more continual measurement of biological signals of a user, which gives information of the user from wearable sensors. In this paper, we propose a wearable context aware system for ubiquitous healthcare, and its systematic design process of a ubiquitous healthcare service. Some wearable sensor systems are introduced with Zigbee communication. We develop a context aware framework to send information from wearable sensors to healthcare service entities as a middleware to solve the interoperability problem between sensor makers and healthcare service providers. And, we propose a systematic process of design of ubiquitous healthcare services with the context aware framework. In order to show the feasibility of the proposed system, some application examples are given, which are applied to remote monitoring, and a self check service