Jun-Tae Kang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jun-Tae Kang has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
Yoon-Ho Song
Electronics and Telecommunications Research Institute (Korea, Republic of)
40 shared publicationsJae-Woo Kim
Electronics and Telecommunications Research Institute (Korea, Republic of)
28 shared publicationsJin-Woo Jeong
Electronics and Telecommunications Research Institute (Korea, Republic of)
24 shared publicationsSungyoul Choi
Nano-Electron Source Creative Research Center, Electronics and Telecommunication Research Institute, 218 Gajeong-ro, Yuseong-gu, Daejeon 305-700, Republic of Korea
21 shared publications- Jin-Woo Jeong
Electronics and Telecommunications Research Institute, Daejeon 305-700, Korea
20 shared publications Hyojin Jeon
Electronics and Telecommunications Research Institute (Korea, Republic of)
18 shared publications
Latest Publications
- 24 March 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (7) , 11847-11861
Characterization of source coherence requirements for laboratory x-ray diffraction imaging
Young’s double-slit (YDS) fringe visibility provides a detector-accessible measure of spatial coherence, but implementing hard-X-ray YDS experiments with compact laboratory sources is fundamentally constrained by the coherence–flux trade-off imposed by spatial filtering. Here we present an end-to-end simulation framework that couples SHADOW3 ray statistics with WOFRY wave-optics propagation to evaluate detector-level interference patterns and feasibility metrics under partial coherence. Partial coherence is defined directly at the pinhole plane by discretizing the pinhole-filtered angular spectrum into a weighted angular-tilt ensemble, which is propagated through Fresnel (pinhole to slit) and Fraunhofer (slit to detector) operators with energy-conserving binning onto an oversampled detector grid. Across parameter sweeps of effective source size w (20–200 µm), source–pinhole distance S (3.0–4.7 m), pinhole diameter D (3–10 µm), pinhole–slit distance R (0.01–1.0 m), and Gaussian relative bandwidth σ BW (0.1–5%), we evaluate Michelson visibility V , detector-ROI photon counts N det , and a photon-statistics-aware figure of merit FOM = V 2 N det . To capture bandwidth-driven degradation not reflected by global visibility alone, we additionally introduce a longitudinal-coherence wash-out metric LC ratio . The resulting inverse-design maps reveal two distinct operating regimes. For larger sources ( w ∼200 µm), the feasible design space becomes visibility-limited, while smaller sources ( w ∼50 µm) operate primarily in a throughput-limited regime where performance improves monotonically with photon acceptance. Absolute photon statistics are anchored by calibrating the pinhole-transmitted flux to a published laboratory benchmark (≈5 × 10 3 ph/s through a 5 µm pinhole at 0.1% σ BW ), enabling exposure-time interpretation of the design maps in experimentally meaningful units. The framework therefore provides a quantitative guideline for selecting source filtering and propagation geometry in compact laboratory YDS measurements under realistic coherence and photon-statistics constraints.
- 24 March 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (7) , 11847-11861
Characterization of source coherence requirements for laboratory x-ray diffraction imaging
Young’s double-slit (YDS) fringe visibility provides a detector-accessible measure of spatial coherence, but implementing hard-X-ray YDS experiments with compact laboratory sources is fundamentally constrained by the coherence–flux trade-off imposed by spatial filtering. Here we present an end-to-end simulation framework that couples SHADOW3 ray statistics with WOFRY wave-optics propagation to evaluate detector-level interference patterns and feasibility metrics under partial coherence. Partial coherence is defined directly at the pinhole plane by discretizing the pinhole-filtered angular spectrum into a weighted angular-tilt ensemble, which is propagated through Fresnel (pinhole to slit) and Fraunhofer (slit to detector) operators with energy-conserving binning onto an oversampled detector grid. Across parameter sweeps of effective source size w (20–200 µm), source–pinhole distance S (3.0–4.7 m), pinhole diameter D (3–10 µm), pinhole–slit distance R (0.01–1.0 m), and Gaussian relative bandwidth σ BW (0.1–5%), we evaluate Michelson visibility V , detector-ROI photon counts N det , and a photon-statistics-aware figure of merit FOM = V 2 N det . To capture bandwidth-driven degradation not reflected by global visibility alone, we additionally introduce a longitudinal-coherence wash-out metric LC ratio . The resulting inverse-design maps reveal two distinct operating regimes. For larger sources ( w ∼200 µm), the feasible design space becomes visibility-limited, while smaller sources ( w ∼50 µm) operate primarily in a throughput-limited regime where performance improves monotonically with photon acceptance. Absolute photon statistics are anchored by calibrating the pinhole-transmitted flux to a published laboratory benchmark (≈5 × 10 3 ph/s through a 5 µm pinhole at 0.1% σ BW ), enabling exposure-time interpretation of the design maps in experimentally meaningful units. The framework therefore provides a quantitative guideline for selecting source filtering and propagation geometry in compact laboratory YDS measurements under realistic coherence and photon-statistics constraints.
- 10 October 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (42) , 49854-49864
Effects of Interfacial Electron Transport on Field Electron Emission from Carbon Nanotube Paste Emitters
Field electron emission from carbon nanotubes (CNT) is preceded by the transport of electrons from the cathode metal to emission sites. Specifically, a supporting layer indispensable for adhesion of CNT paste emitters onto the cathode metal would impose a potential barrier, depending on its work function and interfacial electron transport behaviors. In this paper, we investigated the supporting layer of silicon carbide and nickel nanoparticles reacted onto a Kovar alloy (Fe-Ni-Co) cathode substrate, which has been adopted for reliable CNT paste emitters. The X-ray diffraction, X-ray photoelectron spectroscopy, ultraviolet photoelectron spectroscopy, and electrical conductivity measurements showed that the reaction of silicon carbide and nickel nanoparticles on the Kovar metal strongly depends upon the post-vacuum-annealing conditions and can be classified into two procedures of a diffusion-induced reaction (DIR) and a diffusion-limited reaction (DLR). The prolonged annealing at 750 °C for 5 h before the main annealing of the CNT paste emitters at 800 °C for 5 min led to the DIR that has enhanced the Ni silicide phase and a lower potential barrier for the interfacial electron transport, resulting in increased and weakly temperature-dependent field electron emission from the CNT paste emitters. On the other hand, the DLR with only the main anneal of the CNT paste emitters at 800 °C for 5 min gave rise to a higher potential barrier for the electron transport and so lower and strongly temperature-dependent field electron emission. From the results of the interfacial electron transport for the DIR and DLR mechanisms in the CNT paste emitters, we concluded that the ambient temperature dependency of field electron emission from CNT tips in the moderate range of up to 400 °C, still controversial, is mainly attributed to the supporting layer of the CNT emitter rather than its intrinsic electron emission.
- 10 October 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (42) , 49854-49864
Effects of Interfacial Electron Transport on Field Electron Emission from Carbon Nanotube Paste Emitters
Field electron emission from carbon nanotubes (CNT) is preceded by the transport of electrons from the cathode metal to emission sites. Specifically, a supporting layer indispensable for adhesion of CNT paste emitters onto the cathode metal would impose a potential barrier, depending on its work function and interfacial electron transport behaviors. In this paper, we investigated the supporting layer of silicon carbide and nickel nanoparticles reacted onto a Kovar alloy (Fe-Ni-Co) cathode substrate, which has been adopted for reliable CNT paste emitters. The X-ray diffraction, X-ray photoelectron spectroscopy, ultraviolet photoelectron spectroscopy, and electrical conductivity measurements showed that the reaction of silicon carbide and nickel nanoparticles on the Kovar metal strongly depends upon the post-vacuum-annealing conditions and can be classified into two procedures of a diffusion-induced reaction (DIR) and a diffusion-limited reaction (DLR). The prolonged annealing at 750 °C for 5 h before the main annealing of the CNT paste emitters at 800 °C for 5 min led to the DIR that has enhanced the Ni silicide phase and a lower potential barrier for the interfacial electron transport, resulting in increased and weakly temperature-dependent field electron emission from the CNT paste emitters. On the other hand, the DLR with only the main anneal of the CNT paste emitters at 800 °C for 5 min gave rise to a higher potential barrier for the electron transport and so lower and strongly temperature-dependent field electron emission. From the results of the interfacial electron transport for the DIR and DLR mechanisms in the CNT paste emitters, we concluded that the ambient temperature dependency of field electron emission from CNT tips in the moderate range of up to 400 °C, still controversial, is mainly attributed to the supporting layer of the CNT emitter rather than its intrinsic electron emission.
- 1 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10948, 53
Ultra-short, high-dose rate digital x-ray tube based on carbon nanotube emitters for advanced cone-beam breast computed tomography
Cone-beam breast computed tomography (CBCT) would be a promising modality in screening and diagnosis of breast, providing complete 3-dimensional images with little painful compression of breast during the imaging compared to conventional mammography and tomosynthesis. To date, all CBCT systems including a commercial one by Koning have been utilizing a typical filament-based x-ray tube. However, the filament-based x-ray tube even in a grid type has strict limitation in time resolution, of longer than few milliseconds, with a limited dose rate to cause a large motion blur in CBCT projection images. Micro-calcifications of less than 1 mm in early breast cancer could be hardly distinguished by using conventional CBCT systems. We tried to solve this problem by adopting a fast digital x-ray tube based on carbon nanotube (CNT) field emitters. We, for the first time, developed a rotational anode x-ray tube with CNT emitters for advanced CBCTs. The x-ray tube consisted of CNT paste-emitters and a rotating anode made of W/Re target, and was fully vacuum-sealed with a glass envelope. Ultra-short x-ray pulses of less than sub-ms with a moderate high current of more than 200 mA and a focal spot of ~0.3 in nominal value was successfully obtained. We performed preliminary studies on CBCT imaging using the digital x-ray tube and achieved 300 projection images for 10 s, great reducing motion blurs in the images. It is expected that the CNT digital x-ray tube developed improves CBCT imaging greatly and then promotes CBCT modality in breast screening and diagnosis.
- 1 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10948, 53
Ultra-short, high-dose rate digital x-ray tube based on carbon nanotube emitters for advanced cone-beam breast computed tomography
Cone-beam breast computed tomography (CBCT) would be a promising modality in screening and diagnosis of breast, providing complete 3-dimensional images with little painful compression of breast during the imaging compared to conventional mammography and tomosynthesis. To date, all CBCT systems including a commercial one by Koning have been utilizing a typical filament-based x-ray tube. However, the filament-based x-ray tube even in a grid type has strict limitation in time resolution, of longer than few milliseconds, with a limited dose rate to cause a large motion blur in CBCT projection images. Micro-calcifications of less than 1 mm in early breast cancer could be hardly distinguished by using conventional CBCT systems. We tried to solve this problem by adopting a fast digital x-ray tube based on carbon nanotube (CNT) field emitters. We, for the first time, developed a rotational anode x-ray tube with CNT emitters for advanced CBCTs. The x-ray tube consisted of CNT paste-emitters and a rotating anode made of W/Re target, and was fully vacuum-sealed with a glass envelope. Ultra-short x-ray pulses of less than sub-ms with a moderate high current of more than 200 mA and a focal spot of ~0.3 in nominal value was successfully obtained. We performed preliminary studies on CBCT imaging using the digital x-ray tube and achieved 300 projection images for 10 s, great reducing motion blurs in the images. It is expected that the CNT digital x-ray tube developed improves CBCT imaging greatly and then promotes CBCT modality in breast screening and diagnosis.
- 4 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 39 (12) , 1936-1939
A Fully Closed Nano-Focus X-Ray Source With Carbon Nanotube Field Emitters
We developed a fully closed nano-focus x-ray source using carbon nanotube (CNT) field emitters. The nano-focus x-ray source includes a fully vacuum-sealed CNT Electron-gun (E-gun) tube and E-beam-focusing modules consisting of electrostatic and magnetic lenses, facilitating very compact and high-resolution x-ray imaging. The paste-printed CNT emitters were prepared in a small pattern as an electron source, and the entire components including the CNT emitter module, Cu tubes, collimators, and transmissive anode target were specially brazed at an elevated temperature, resulting in a very compact E-gun tube. The CNT emitter showed a stable and reliable emission current with its density of over 300 mA/cm2 even in the vacuum-sealed E-gun tube. With the anode grounded and the CNT emitter module biased to negative high voltages, we achieved a considerably magnified x-ray image of a several hundred nanometer resolution. The fully vacuum-sealed CNT E-gun tube along with the magnetic lens module can offer much more compact, easily maintainable, high-resolution x-ray imaging compared with conventional open-type thermionic x-ray sources.
- 4 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 39 (12) , 1936-1939
A Fully Closed Nano-Focus X-Ray Source With Carbon Nanotube Field Emitters
We developed a fully closed nano-focus x-ray source using carbon nanotube (CNT) field emitters. The nano-focus x-ray source includes a fully vacuum-sealed CNT Electron-gun (E-gun) tube and E-beam-focusing modules consisting of electrostatic and magnetic lenses, facilitating very compact and high-resolution x-ray imaging. The paste-printed CNT emitters were prepared in a small pattern as an electron source, and the entire components including the CNT emitter module, Cu tubes, collimators, and transmissive anode target were specially brazed at an elevated temperature, resulting in a very compact E-gun tube. The CNT emitter showed a stable and reliable emission current with its density of over 300 mA/cm2 even in the vacuum-sealed E-gun tube. With the anode grounded and the CNT emitter module biased to negative high voltages, we achieved a considerably magnified x-ray image of a several hundred nanometer resolution. The fully vacuum-sealed CNT E-gun tube along with the magnetic lens module can offer much more compact, easily maintainable, high-resolution x-ray imaging compared with conventional open-type thermionic x-ray sources.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Two applications of carbon nanotube paste emitters: nano-focus, and high-flux vacuum-sealed x-ray tubes
The printed carbon nanotube (CNT) paste emitters were applied to two types of vacuum-sealed x-ray tubes for several hundred-nanometer-resolution non-destructive testing (NDT) and cone-beam breast computed tomography (CB-BCT) applications. A single dot CNT emitter of 200 micrometer in diameter was made for a small focal spot size of NDT imaging meanwhile a 983-dots array was for a high current of CB-BCT imaging. The electron beam emitted from the single dot emitter in the nano-focus x-ray tube is strongly focused to a small focal spot size of 1 micrometer or less in diameter by help of electrostatic and magnetic focusing lenses, and the 983 emitters produce a large field emission current over 200 mA with a moderate focal spot, tentatively applicable to CB-BCT imaging. The printed CNT emitters can be used for a variety of electron sources from several hundred-nanometer focusing to high-flux xray tubes.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Two applications of carbon nanotube paste emitters: nano-focus, and high-flux vacuum-sealed x-ray tubes
The printed carbon nanotube (CNT) paste emitters were applied to two types of vacuum-sealed x-ray tubes for several hundred-nanometer-resolution non-destructive testing (NDT) and cone-beam breast computed tomography (CB-BCT) applications. A single dot CNT emitter of 200 micrometer in diameter was made for a small focal spot size of NDT imaging meanwhile a 983-dots array was for a high current of CB-BCT imaging. The electron beam emitted from the single dot emitter in the nano-focus x-ray tube is strongly focused to a small focal spot size of 1 micrometer or less in diameter by help of electrostatic and magnetic focusing lenses, and the 983 emitters produce a large field emission current over 200 mA with a moderate focal spot, tentatively applicable to CB-BCT imaging. The printed CNT emitters can be used for a variety of electron sources from several hundred-nanometer focusing to high-flux xray tubes.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
A novel vacuum-sealed field emission x-ray tube with graphene-gated carbon nanotube emitters
Multilayer graphene-gated carbon nanotube (CNT) emitters are introduced to novel vacuum-sealed x-ray tubes. We characterized field emission performances and electron-beam (Ebeam) converging of the graphene-gated emitter in a vacuum chamber. Thermal durability of the graphene-gate was well achieved to apply it to x-ray tubes processed with brazing at a high temperature. A transmissive anode target with a Be window, ceramic insulators, and the graphene-gated CNT emitters were successfully brazed to a fully vacuum-sealed x-ray tube, maintaining an unique graphene-gated field emission performance.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
A novel vacuum-sealed field emission x-ray tube with graphene-gated carbon nanotube emitters
Multilayer graphene-gated carbon nanotube (CNT) emitters are introduced to novel vacuum-sealed x-ray tubes. We characterized field emission performances and electron-beam (Ebeam) converging of the graphene-gated emitter in a vacuum chamber. Thermal durability of the graphene-gate was well achieved to apply it to x-ray tubes processed with brazing at a high temperature. A transmissive anode target with a Be window, ceramic insulators, and the graphene-gated CNT emitters were successfully brazed to a fully vacuum-sealed x-ray tube, maintaining an unique graphene-gated field emission performance.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Field Emission Performance of Boron Nitride Nanotube Emitters According to Vacuum Pressure
Field emission performance of boron nitride nanotube (BNNT) fabricated by simple filtration-transfer method, were evaluated according to vacuum pressure to estimate its potential use for robust electron sources. Even though there is little change in the current density-electric field characteristics, the stability test for a relatively long time shows somewhat large degradation at a vacuum pressure of over 10 -5 Torr. To investigate a key factor of the degradation, we changed the vacuum ambient from air to argon. Under argon ambient condition, the current degradation and fluctuation rates were almost the same as those measured under air ambient at a vacuum pressure of 10 -5 Torr. Consequently, ion bombardment dominantly induced the current degradation of the BNNT field emitters rather than oxidation effect.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Field Emission Performance of Boron Nitride Nanotube Emitters According to Vacuum Pressure
Field emission performance of boron nitride nanotube (BNNT) fabricated by simple filtration-transfer method, were evaluated according to vacuum pressure to estimate its potential use for robust electron sources. Even though there is little change in the current density-electric field characteristics, the stability test for a relatively long time shows somewhat large degradation at a vacuum pressure of over 10 -5 Torr. To investigate a key factor of the degradation, we changed the vacuum ambient from air to argon. Under argon ambient condition, the current degradation and fluctuation rates were almost the same as those measured under air ambient at a vacuum pressure of 10 -5 Torr. Consequently, ion bombardment dominantly induced the current degradation of the BNNT field emitters rather than oxidation effect.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
High-performance carbon nanotube paste emitters by using the optimal size distribution of SiC nanometer-fillers aggregates
We improved carbon nanotube (CNT) paste field emitter by optimizing the size distribution of SiC aggregates as inorganic fillers using a novel milling process. The average size of SiC aggregates was reduced to sub-micrometer with a relatively narrow distribution. The CNT paste emitter with the optimized small SiC fillers of 1 m in D50, by the milling process, exhibited better adhesive property and more uniform surface morphology than that with large fillers from the as-purchased SiC. Furthermore, the optimized small fillers shows superior field emission performance even under a high current density, making the CNT paste technology very useful for a variety of field emission devices.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
High-performance carbon nanotube paste emitters by using the optimal size distribution of SiC nanometer-fillers aggregates
We improved carbon nanotube (CNT) paste field emitter by optimizing the size distribution of SiC aggregates as inorganic fillers using a novel milling process. The average size of SiC aggregates was reduced to sub-micrometer with a relatively narrow distribution. The CNT paste emitter with the optimized small SiC fillers of 1 m in D50, by the milling process, exhibited better adhesive property and more uniform surface morphology than that with large fillers from the as-purchased SiC. Furthermore, the optimized small fillers shows superior field emission performance even under a high current density, making the CNT paste technology very useful for a variety of field emission devices.
- 9 March 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10573, 87
A fully vacuum-sealed miniature x-ray tube with carbon nanotube field emitters for compact portable dental x-ray system
There have been many efforts to develop x-ray sources using field electron emitters instead of conventional thermionic cathodes for digital controlling of x-rays in medical imaging. Specially, portable x-ray systems need a miniature x-ray tube with less-power consumption, easy insulation of high voltage and light shielding of x-rays. Carbon nanotube (CNT) has attracted much attention as the most promising field emitter due to its geometric high aspect ratio, high physical and chemical inertness. To date, however, CNT field emitters have not been satisfactorily incorporated into a fully vacuum-sealed x-ray tube due to their instability and/or unreliability. We successfully developed a fully vacuum-sealed, miniature x-ray tube with CNT emitters for portable dental x-ray systems. The x-ray tube was designed in a triode configuration with a self-electron focusing gate and reliable CNT emitters, and was fully vacuum-sealed within a miniaturized volume of 15 mm in diagonal and 65 mm in length, very tiny and small as compared with conventional thermionic one. The nominal focal spot size of the x-ray tube is 0.4 mm with an operational tube voltage of 65 kV and a current of 3 mA, which offers quite good x-ray images of a human tooth phantom. No heating the miniature x-ray tube for electron emission leads to easy insulation of high tube voltage and light shielding of x-rays, giving a compact and light portable x-ray system. Furthermore, digital operation of the x-ray tube through an active-current control could provide a commercial lifetime along with pretty good stability.
- 9 March 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10573, 87
A fully vacuum-sealed miniature x-ray tube with carbon nanotube field emitters for compact portable dental x-ray system
There have been many efforts to develop x-ray sources using field electron emitters instead of conventional thermionic cathodes for digital controlling of x-rays in medical imaging. Specially, portable x-ray systems need a miniature x-ray tube with less-power consumption, easy insulation of high voltage and light shielding of x-rays. Carbon nanotube (CNT) has attracted much attention as the most promising field emitter due to its geometric high aspect ratio, high physical and chemical inertness. To date, however, CNT field emitters have not been satisfactorily incorporated into a fully vacuum-sealed x-ray tube due to their instability and/or unreliability. We successfully developed a fully vacuum-sealed, miniature x-ray tube with CNT emitters for portable dental x-ray systems. The x-ray tube was designed in a triode configuration with a self-electron focusing gate and reliable CNT emitters, and was fully vacuum-sealed within a miniaturized volume of 15 mm in diagonal and 65 mm in length, very tiny and small as compared with conventional thermionic one. The nominal focal spot size of the x-ray tube is 0.4 mm with an operational tube voltage of 65 kV and a current of 3 mA, which offers quite good x-ray images of a human tooth phantom. No heating the miniature x-ray tube for electron emission leads to easy insulation of high tube voltage and light shielding of x-rays, giving a compact and light portable x-ray system. Furthermore, digital operation of the x-ray tube through an active-current control could provide a commercial lifetime along with pretty good stability.