Michael Smith
Research Subjects
Michael Smith has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Daniel Byles
West of England Eye Unit, Royal Devon and Exeter Hospital, Exeter, UK
2 shared publicationsGraham E. MB BCh Trope
Department of Ophthalmology and Visual Sciences, Toronto Western Hospital, Toronto, Ontario, Canada
2 shared publicationsLei-Ai Lim
Ophthalmology Department, Musgrove Park Hospital, Taunton, UK
2 shared publicationsNoa Geffen
Department of Ophthalmology and Visual Sciences, Toronto Western Hospital, Toronto, Ontario, Canada
2 shared publicationsTariq Alasbali
Department of Ophthalmology and Visual Sciences, Toronto Western Hospital, Toronto, Ontario, Canada
2 shared publicationsYvonne M. Md Buys
Department of Ophthalmology and Visual Sciences, Toronto Western Hospital, Toronto, Ontario, Canada
2 shared publications
Latest Publications
- Open Access
- 1 April 2021
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 15, 1715-1726
Pilot Study of Clinician-Patient Collaboration in Glaucoma
Purpose: This pilot study was undertaken to examine the feasibility of a larger scale trial examining the effect of interventions to improve patient-clinician collaboration. The primary outcome was the extent of clinician-patient collaboration during glaucoma consultations. The secondary outcomes were the results of the Patient Experience Questionnaire and the patients’ opinion of how involved they were in decisions about their care and how keen they would be to increase this involvement. Methods: This is an observational study of clinician-patient communication involving 9 glaucoma clinicians and 37 patients attending a glaucoma monitoring clinic. Consultations were videotaped and later assessed for the degree of collaboration. Patients completed a validated Patient Experience Questionnaire and a questionnaire designed to collect the patients’ opinion of how involved they were in decisions about their care. Results: The consultations were largely “clinician centred” with clinicians speaking 58% of the sentences and asking a mean of 8.1 questions compared to the patients 2.6. Glaucoma medications were discussed in 97% of consultations. When a treatment change was recommended in 53% of cases different options were discussed. Patients had an overall positive opinion of the consultations. Although 80% of patients indicated they were happy with how involved they were in decisions about their care 44% said they would like to be more involved, and 47% would welcome written information or information sessions on how to be more involved in decisions about their care. Conclusion: Glaucoma consultations remain “clinician-centred” and, in view of the evidence of the benefits of good clinician-patient collaboration, further studies to examine interventions to improve clinician-patient collaboration may be of benefit to glaucoma patients. These interventions could target both clinicians and patients, and many patients in this study indicated they would like to be more involved in decisions about their care and would welcome support in achieving this.
- 1 April 2021
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 15, 1715-1726
Open AccessPilot Study of Clinician-Patient Collaboration in Glaucoma
Purpose: This pilot study was undertaken to examine the feasibility of a larger scale trial examining the effect of interventions to improve patient-clinician collaboration. The primary outcome was the extent of clinician-patient collaboration during glaucoma consultations. The secondary outcomes were the results of the Patient Experience Questionnaire and the patients’ opinion of how involved they were in decisions about their care and how keen they would be to increase this involvement. Methods: This is an observational study of clinician-patient communication involving 9 glaucoma clinicians and 37 patients attending a glaucoma monitoring clinic. Consultations were videotaped and later assessed for the degree of collaboration. Patients completed a validated Patient Experience Questionnaire and a questionnaire designed to collect the patients’ opinion of how involved they were in decisions about their care. Results: The consultations were largely “clinician centred” with clinicians speaking 58% of the sentences and asking a mean of 8.1 questions compared to the patients 2.6. Glaucoma medications were discussed in 97% of consultations. When a treatment change was recommended in 53% of cases different options were discussed. Patients had an overall positive opinion of the consultations. Although 80% of patients indicated they were happy with how involved they were in decisions about their care 44% said they would like to be more involved, and 47% would welcome written information or information sessions on how to be more involved in decisions about their care. Conclusion: Glaucoma consultations remain “clinician-centred” and, in view of the evidence of the benefits of good clinician-patient collaboration, further studies to examine interventions to improve clinician-patient collaboration may be of benefit to glaucoma patients. These interventions could target both clinicians and patients, and many patients in this study indicated they would like to be more involved in decisions about their care and would welcome support in achieving this.
- Open Access
- 27 November 2019
- Published by Wiley in Clinical Case Reports
- Vol. 8 (1) , 13-17
Repair of iatrogenic pulmonary vein occlusion with a vascularized atrial flap
Pulmonary vein obstruction is a rare condition, most commonly reported following pulmonary vein catheter ablation for atrial arrhythmia. This novel technique for treatment of pulmonary venous obstruction has the advantage of utilizing an autologous vascularized flap with intact endothelium for reconstruction of the pulmonary vein and to prevent restenosis.
- 27 November 2019
- Published by Wiley in Clinical Case Reports
- Vol. 8 (1) , 13-17
Open AccessRepair of iatrogenic pulmonary vein occlusion with a vascularized atrial flap
Pulmonary vein obstruction is a rare condition, most commonly reported following pulmonary vein catheter ablation for atrial arrhythmia. This novel technique for treatment of pulmonary venous obstruction has the advantage of utilizing an autologous vascularized flap with intact endothelium for reconstruction of the pulmonary vein and to prevent restenosis.
- 14 December 2018
- Published by Springer Nature in Eye
- Vol. 33 (5) , 761-766
1-year outcomes of the Xen45 glaucoma implant
To describe the 12-month outcomes of the Xen45 glaucoma stent. Non-comparative retrospective study of all cases who underwent Xen glaucoma surgery in April 2017 or earlier and completed 12 months of follow-up. The primary outcome measures were intraocular pressure (IOP) reduction and number of glaucoma medications at 12 months postoperatively. The secondary outcome measures were surgical complications and the success rate of surgery at 1 year. Success rate was defined according to the multiple IOP thresholds of 15 mmHg, 18 mmHg, and 21 mmHg with all requiring a drop of 20% and no additional glaucoma surgery. Revision or needling of the Xen conjunctival bleb was not considered to constitute a surgical failure. Sixty-eight eyes were included in the study. Mean IOP dropped from 22.1 mmHg preoperatively to 14.8 mmHg at 12 months, a 33% drop (p < 0.0001). Mean number of glaucoma medications reduced from 2.9 preoperatively to 1.1 at 12 months (p < 0.0001). In total, 54.4% of cases were back on glaucoma medications by 12 months. Success rate varied from 32.4% when defined as IOP ≤ 15 mmHg and ≥ 6 mmHg and ≥ 20% reduction without medications to 70.6% when defined as IOP ≤ 21 mmHg and ≥ 6 mmHg and ≥ 20% reduction with or without medications. Thirty cases (44.1%) required bleb needling or surgical revision. The Xen45 is effective at reducing IOP and glaucoma medication use at 12 months postoperatively. Patients considering this procedure should be warned that by 12 months postoperatively there is a significant chance of requiring postoperative bleb intervention and glaucoma drops.
- 14 December 2018
- Published by Springer Nature in Eye
- Vol. 33 (5) , 761-766
1-year outcomes of the Xen45 glaucoma implant
To describe the 12-month outcomes of the Xen45 glaucoma stent. Non-comparative retrospective study of all cases who underwent Xen glaucoma surgery in April 2017 or earlier and completed 12 months of follow-up. The primary outcome measures were intraocular pressure (IOP) reduction and number of glaucoma medications at 12 months postoperatively. The secondary outcome measures were surgical complications and the success rate of surgery at 1 year. Success rate was defined according to the multiple IOP thresholds of 15 mmHg, 18 mmHg, and 21 mmHg with all requiring a drop of 20% and no additional glaucoma surgery. Revision or needling of the Xen conjunctival bleb was not considered to constitute a surgical failure. Sixty-eight eyes were included in the study. Mean IOP dropped from 22.1 mmHg preoperatively to 14.8 mmHg at 12 months, a 33% drop (p < 0.0001). Mean number of glaucoma medications reduced from 2.9 preoperatively to 1.1 at 12 months (p < 0.0001). In total, 54.4% of cases were back on glaucoma medications by 12 months. Success rate varied from 32.4% when defined as IOP ≤ 15 mmHg and ≥ 6 mmHg and ≥ 20% reduction without medications to 70.6% when defined as IOP ≤ 21 mmHg and ≥ 6 mmHg and ≥ 20% reduction with or without medications. Thirty cases (44.1%) required bleb needling or surgical revision. The Xen45 is effective at reducing IOP and glaucoma medication use at 12 months postoperatively. Patients considering this procedure should be warned that by 12 months postoperatively there is a significant chance of requiring postoperative bleb intervention and glaucoma drops.
- 1 September 2018
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 44 (9) , 1097-1102
Phacoemulsification and endocyclophotocoagulation in uncontrolled glaucoma: Three-year results
To describe the 3-year outcomes of combined cataract surgery and 360-degree endocyclophotocoagulation (ECP) in eyes with uncontrolled glaucoma and no previous glaucoma drainage surgery. University Hospital Eye Department, Exeter, United Kingdom. Retrospective case series. The study included patients who had combined cataract surgery and 360-degree ECP. The primary outcome measure was intraocular pressure (IOP) reduction at 3 years postoperatively. Secondary outcome measures were the cumulative probability of failure of the surgical procedure at 3 years and the complications of surgery. Failure was defined by 1 of 2 criteria: (1) IOP higher than 21 mm Hg or lower than 6 mm Hg or not reduced by 20% from baseline at the 1-, 2-, or 3-year timepoint and (2) further laser or other surgery to reduce IOP at any timepoint. The study comprised 84 patients (84 eyes). The mean IOP dropped from 18.7 mm Hg preoperatively to 13.3 mm Hg, 13.8 mm Hg, and 14.0 mm Hg at 1, 2, and 3 years postoperatively, respectively. By the 3-year timepoint, 58.3% had met the criteria for failure. The mean number of glaucoma medications was similar at 2.5 at 3 years postoperatively compared with 2.6 preoperatively. Nine patients (10.7%) had a significant complication, but all resolved without long-term sequelae. At 3 years postoperatively, combined cataract surgery and 360-degree ECP achieved a modest but significant drop in IOP in phakic patients with uncontrolled glaucoma and no previous drainage surgery. There was a low incidence of serious side effects but nearly 60% were classified as failures by 3 years.
- 1 September 2018
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 44 (9) , 1097-1102
Phacoemulsification and endocyclophotocoagulation in uncontrolled glaucoma: Three-year results
To describe the 3-year outcomes of combined cataract surgery and 360-degree endocyclophotocoagulation (ECP) in eyes with uncontrolled glaucoma and no previous glaucoma drainage surgery. University Hospital Eye Department, Exeter, United Kingdom. Retrospective case series. The study included patients who had combined cataract surgery and 360-degree ECP. The primary outcome measure was intraocular pressure (IOP) reduction at 3 years postoperatively. Secondary outcome measures were the cumulative probability of failure of the surgical procedure at 3 years and the complications of surgery. Failure was defined by 1 of 2 criteria: (1) IOP higher than 21 mm Hg or lower than 6 mm Hg or not reduced by 20% from baseline at the 1-, 2-, or 3-year timepoint and (2) further laser or other surgery to reduce IOP at any timepoint. The study comprised 84 patients (84 eyes). The mean IOP dropped from 18.7 mm Hg preoperatively to 13.3 mm Hg, 13.8 mm Hg, and 14.0 mm Hg at 1, 2, and 3 years postoperatively, respectively. By the 3-year timepoint, 58.3% had met the criteria for failure. The mean number of glaucoma medications was similar at 2.5 at 3 years postoperatively compared with 2.6 preoperatively. Nine patients (10.7%) had a significant complication, but all resolved without long-term sequelae. At 3 years postoperatively, combined cataract surgery and 360-degree ECP achieved a modest but significant drop in IOP in phakic patients with uncontrolled glaucoma and no previous drainage surgery. There was a low incidence of serious side effects but nearly 60% were classified as failures by 3 years.
- 29 August 2018
- Published by Springer Nature in Eye
- Vol. 32 (12) , 1893-1899
Long-term outcome of mitomycin C-augmented needle revision of trabeculectomy blebs for late trabeculectomy failure
To describe the 3-year outcomes of mitomycin C (MMC)-augmented bleb needling procedures following late trabeculectomy failure. A retrospective, observational chart review of 44 eyes that underwent MMC-augmented bleb needling following late trabeculectomy failure. The primary outcome measure was IOP at 3 years post-operatively. Secondary outcome measures were the number of topical glaucoma medications and success rate at 3 years. Success was defined on the basis of IOP (≤21 mmHg and ≥5 mmHg with a reduction of ≥ 20% from pre-operative baseline), need for ocular hypotensive medications, and need for further laser or surgical intervention. Mean IOP was reduced from 19.8 mmHg preoperatively to 13.9 mmHg (29.5% reduction) at 3 years. By the 3-year time point, 26 eyes (59.1%) had met one or more of the criteria for failure. A lower immediate post-operative IOP was found to be associated with greater likelihood of success. Bleb needling augmented with MMC can achieve a significant reduction in IOP in eyes with late trabeculectomy failure. By 3 years however, 59% of eyes were classified as failures, with half requiring further glaucoma surgery or laser. Patients undergoing this procedure should therefore be warned of the likelihood of requiring further intervention, and a repeat antimetabolite-augmented trabeculectomy or glaucoma tube shunt surgery in the first instance can be considered instead.
- 29 August 2018
- Published by Springer Nature in Eye
- Vol. 32 (12) , 1893-1899
Long-term outcome of mitomycin C-augmented needle revision of trabeculectomy blebs for late trabeculectomy failure
To describe the 3-year outcomes of mitomycin C (MMC)-augmented bleb needling procedures following late trabeculectomy failure. A retrospective, observational chart review of 44 eyes that underwent MMC-augmented bleb needling following late trabeculectomy failure. The primary outcome measure was IOP at 3 years post-operatively. Secondary outcome measures were the number of topical glaucoma medications and success rate at 3 years. Success was defined on the basis of IOP (≤21 mmHg and ≥5 mmHg with a reduction of ≥ 20% from pre-operative baseline), need for ocular hypotensive medications, and need for further laser or surgical intervention. Mean IOP was reduced from 19.8 mmHg preoperatively to 13.9 mmHg (29.5% reduction) at 3 years. By the 3-year time point, 26 eyes (59.1%) had met one or more of the criteria for failure. A lower immediate post-operative IOP was found to be associated with greater likelihood of success. Bleb needling augmented with MMC can achieve a significant reduction in IOP in eyes with late trabeculectomy failure. By 3 years however, 59% of eyes were classified as failures, with half requiring further glaucoma surgery or laser. Patients undergoing this procedure should therefore be warned of the likelihood of requiring further intervention, and a repeat antimetabolite-augmented trabeculectomy or glaucoma tube shunt surgery in the first instance can be considered instead.
- 1 January 2010
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 19 (1) , 11-14
Digital Ocular Massage for Hypertensive Phase After Ahmed Valve Surgery
Purpose To examine the role of ocular massage during the hypertensive phase after Ahmed valve surgery Methods Nonrandomized prospective study. Results Eighteeen patients with intraocular pressure (IOP) above target 1 to 8 weeks after Ahmed glaucoma drainage device surgery underwent digital ocular massage. The mean IOP 1 hour after massage was 4.3 mm Hg lower than before massage (18.8%, P=0.0008). We used a 20% reduction in IOP at 1-hour postmassage to differentiate responders from nonresponders and by this definition 50% responded to ocular massage. One patient (5.6%) responded well but was unable to perform massage at home. The remaining 8 patients (44.4%) performed regular digital massage and the 20% drop in IOP was maintained at the 2-week, 6-week, and 6-month review, although by 6 months 50% required glaucoma drops to achieve target IOP. There were no massage-associated complications in this series. Conclusions Digital ocular massage has a useful role to play in the management of the hypertensive phase after Ahmed glaucoma drainage device surgery. In this series 50% of patients achieved a 20% drop in IOP with massage.
- 1 January 2010
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 19 (1) , 11-14
Digital Ocular Massage for Hypertensive Phase After Ahmed Valve Surgery
Purpose To examine the role of ocular massage during the hypertensive phase after Ahmed valve surgery Methods Nonrandomized prospective study. Results Eighteeen patients with intraocular pressure (IOP) above target 1 to 8 weeks after Ahmed glaucoma drainage device surgery underwent digital ocular massage. The mean IOP 1 hour after massage was 4.3 mm Hg lower than before massage (18.8%, P=0.0008). We used a 20% reduction in IOP at 1-hour postmassage to differentiate responders from nonresponders and by this definition 50% responded to ocular massage. One patient (5.6%) responded well but was unable to perform massage at home. The remaining 8 patients (44.4%) performed regular digital massage and the 20% drop in IOP was maintained at the 2-week, 6-week, and 6-month review, although by 6 months 50% required glaucoma drops to achieve target IOP. There were no massage-associated complications in this series. Conclusions Digital ocular massage has a useful role to play in the management of the hypertensive phase after Ahmed glaucoma drainage device surgery. In this series 50% of patients achieved a 20% drop in IOP with massage.
- 1 December 2009
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 18 (9) , 674-678
Outcome of Ahmed Valve Implantation When Preoperative IOP Less Than 21 mm Hg
Purpose To examine the results of Ahmed glaucoma drainage device (GDD) implantation in patients with a preoperative intraocular pressure (IOP) of 20 mm Hg or less. Methods Noncomparative retrospective case series. Results Sixty-six surgeries in 63 patients were analyzed. Mean follow-up was 51 months. The mean drop in IOP was 3.8 mm Hg (23.3%, PP<0.0001) at final follow-up. The number of glaucoma medications used postoperatively was significantly less than preoperatively. Although the mean visual acuity was poorer postoperatively this did not reach statistical significance. Surgical success was defined as IOP ≥5 mm Hg and 20% lower than preoperatively with or without hypotensive therapy, visual acuity perception of light or better and no further glaucoma surgery. About 57.6% and 53.0% of patients were considered a success at 12 months and final follow-up, respectively. Fourteen patients (21.2%) underwent additional glaucoma surgery, 8 of which had a second Ahmed GDD inserted whereas 6 had cyclodestruction. All failures were due to inadequate IOP control or further glaucoma surgery, with no cases considered failures due to vision loss or hypotony. Perioperative complications developed in 6 cases (9.1%) whereas long-term problems related to surgery occurred in 8 cases (12.1%). Conclusions In patients with IOPs of 20 mm Hg or less who require IOPs in the low teens and below Ahmed GDD surgery does seem to be an effective option. The success rates of surgery, however, must be balanced against the risk of complications. In addition, the relative merits of Ahmed GDD implantation versus mitomycin trabeculectomy and/or nonvalved GDDs requires further investigation.
- 1 December 2009
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 18 (9) , 674-678
Outcome of Ahmed Valve Implantation When Preoperative IOP Less Than 21 mm Hg
Purpose To examine the results of Ahmed glaucoma drainage device (GDD) implantation in patients with a preoperative intraocular pressure (IOP) of 20 mm Hg or less. Methods Noncomparative retrospective case series. Results Sixty-six surgeries in 63 patients were analyzed. Mean follow-up was 51 months. The mean drop in IOP was 3.8 mm Hg (23.3%, PP<0.0001) at final follow-up. The number of glaucoma medications used postoperatively was significantly less than preoperatively. Although the mean visual acuity was poorer postoperatively this did not reach statistical significance. Surgical success was defined as IOP ≥5 mm Hg and 20% lower than preoperatively with or without hypotensive therapy, visual acuity perception of light or better and no further glaucoma surgery. About 57.6% and 53.0% of patients were considered a success at 12 months and final follow-up, respectively. Fourteen patients (21.2%) underwent additional glaucoma surgery, 8 of which had a second Ahmed GDD inserted whereas 6 had cyclodestruction. All failures were due to inadequate IOP control or further glaucoma surgery, with no cases considered failures due to vision loss or hypotony. Perioperative complications developed in 6 cases (9.1%) whereas long-term problems related to surgery occurred in 8 cases (12.1%). Conclusions In patients with IOPs of 20 mm Hg or less who require IOPs in the low teens and below Ahmed GDD surgery does seem to be an effective option. The success rates of surgery, however, must be balanced against the risk of complications. In addition, the relative merits of Ahmed GDD implantation versus mitomycin trabeculectomy and/or nonvalved GDDs requires further investigation.
- 1 April 2009
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 18 (4) , 336-340
Second Ahmed Valve Insertion in the Same Eye
To examine the results of same-eye second Ahmed glaucoma drainage device (GDD) insertion in eyes with refractory glaucoma despite previous Ahmed GDD insertion and maximal tolerated medical therapy. Noncomparative retrospective case series. Twenty-one patients who had undergone 2 GDD surgeries in the same eye were identified. Following chart review, 19 patients had follow-up of at least 1 year and were included in the analysis. All surgeries involved Ahmed valves. The mean drop in intraocular pressure (IOP) at 12 months and at final follow-up was 8 (43%) and 7.9 mm Hg (42%), respectively. The mean number of glaucoma medications used postoperatively (2.4 at 12 mo and 2.6 at final follow-up) was significantly less than preoperatively (4.1). Although the mean visual acuity was poorer postoperatively, this did not reach statistical significance. Sixteen of the 19 patients (84.2%) were defined as complete or partial success, as they achieved IOP of >/=5 and /=20% decrease on preoperative IOP with or without glaucoma drops. Three patients were considered complete failures at 12 months and final follow-up. There were no significant intraoperative complications. One patient (5.3%) required anterior chamber reformation on day 1 postoperatively. One patient (5.3%) suffered a decrease in vision from 20/70 preoperatively to counting fingers postoperatively owing to corneal decompensation. Second Ahmed GDD surgery seems to be a safe and effective option when IOP remains uncontrolled despite previous GDD implantation.
- 1 April 2009
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 18 (4) , 336-340
Second Ahmed Valve Insertion in the Same Eye
To examine the results of same-eye second Ahmed glaucoma drainage device (GDD) insertion in eyes with refractory glaucoma despite previous Ahmed GDD insertion and maximal tolerated medical therapy. Noncomparative retrospective case series. Twenty-one patients who had undergone 2 GDD surgeries in the same eye were identified. Following chart review, 19 patients had follow-up of at least 1 year and were included in the analysis. All surgeries involved Ahmed valves. The mean drop in intraocular pressure (IOP) at 12 months and at final follow-up was 8 (43%) and 7.9 mm Hg (42%), respectively. The mean number of glaucoma medications used postoperatively (2.4 at 12 mo and 2.6 at final follow-up) was significantly less than preoperatively (4.1). Although the mean visual acuity was poorer postoperatively, this did not reach statistical significance. Sixteen of the 19 patients (84.2%) were defined as complete or partial success, as they achieved IOP of >/=5 and /=20% decrease on preoperative IOP with or without glaucoma drops. Three patients were considered complete failures at 12 months and final follow-up. There were no significant intraoperative complications. One patient (5.3%) required anterior chamber reformation on day 1 postoperatively. One patient (5.3%) suffered a decrease in vision from 20/70 preoperatively to counting fingers postoperatively owing to corneal decompensation. Second Ahmed GDD surgery seems to be a safe and effective option when IOP remains uncontrolled despite previous GDD implantation.
- 1 March 2009
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 18 (3) , 217-219
Correlation Between the Indiana Bleb Appearance Grading Scale and Intraocular Pressure After Phacotrabeculectomy
To investigate the relationship between bleb morphology, recorded using the Indiana Bleb Appearance Grading Scale (IBAGS), and intraocular pressure (IOP) after phacotrabeculectomy. Two years postphacotrabeculectomy, a single observer compared bleb morphology to the IBAGS standard photographs in 76 eyes of 76 patients. In addition, the presence or absence of microcysts was recorded. IOP was also measured. On multivariate analysis increasing bleb height was associated with a low IOP (P=0.017). An increase in IBAGS height score by 1 U resulted in a reduction in IOP of 2.16 mm Hg (95% confidence interval=0.40-3.92 mm Hg). In this study, there was no association between vascularity, bleb extent or microcysts, and IOP. There were no cases of bleb leak in this series. Two years postphacotrabeculectomy increased bleb height, as measured by the IBAGS, was associated with a decrease in IOP, with a 1 point increase in IBAGS height score resulting in a decrease of 2.16 mm Hg. We found no association between bleb extent, vascularity, or the presence or absence of conjunctival microcysts. As there were no cases of bleb leak in this study this characteristic could not be evaluated.
- 1 March 2009
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 18 (3) , 217-219
Correlation Between the Indiana Bleb Appearance Grading Scale and Intraocular Pressure After Phacotrabeculectomy
To investigate the relationship between bleb morphology, recorded using the Indiana Bleb Appearance Grading Scale (IBAGS), and intraocular pressure (IOP) after phacotrabeculectomy. Two years postphacotrabeculectomy, a single observer compared bleb morphology to the IBAGS standard photographs in 76 eyes of 76 patients. In addition, the presence or absence of microcysts was recorded. IOP was also measured. On multivariate analysis increasing bleb height was associated with a low IOP (P=0.017). An increase in IBAGS height score by 1 U resulted in a reduction in IOP of 2.16 mm Hg (95% confidence interval=0.40-3.92 mm Hg). In this study, there was no association between vascularity, bleb extent or microcysts, and IOP. There were no cases of bleb leak in this series. Two years postphacotrabeculectomy increased bleb height, as measured by the IBAGS, was associated with a decrease in IOP, with a 1 point increase in IBAGS height score resulting in a decrease of 2.16 mm Hg. We found no association between bleb extent, vascularity, or the presence or absence of conjunctival microcysts. As there were no cases of bleb leak in this study this characteristic could not be evaluated.