    Longer heating duration increases localized doxorubicin deposition and therapeutic index in Vx2 tumors using MR-HIFU mild hyperthermia and thermosensitive liposomal doxorubicin

    by Chenchen Bing, Pratik Patel, Robert M. Staruch, Sumbul Shaikh, Joris Nofiele, Michelle Wodzak Staruch, Debra Szczepanski, Noelle S. Williams, Theodore Laetsch, Rajiv Chopra

    Thermosensitive liposomal doxorubicin (LTSL-Dox) combined with mild hyperthermia enhances the localized delivery of doxorubicin (Dox) within a heated region. The optimal heating duration and the impact of extended heating on systemic drug distribution are unknown. Here we evaluated local and systemic Dox delivery with two different mild hyperthermia durations (42 °C for 10 or 40 minutes) in a Vx2 rabbit tumor model. We hypothesized that longer duration of hyperthermia would increase Dox concentration in heated tumors without increasing systemic exposure. Temporally and spatially accurate controlled hyperthermia was achieved using a clinical MR-HIFU system for the prescribed heating durations. Forty-minutes of heating resulted in a nearly 6-fold increase in doxorubicin concentration in heated vs unheated tumors in the same animals. Therapeutic ratio, defined as the ratio of Dox delivered into the heated tumor vs the heart, increased from 1.9-fold with 10 minutes heating to 4.4-fold with 40 minutes heating. MR-HIFU can be used to guide, deliver and monitor mild hyperthermia of a Vx2 tumor model in a rabbit model, and an increased duration of heating leads to higher Dox deposition from LTSL-Dox in a target tumor without a concomitant increase in systemic exposure. Results from this preclinical study can be used to help establish clinical treatment protocols for hyperthermia mediated drug delivery.


  • Open Access

    Characterization of different bubble formulations for blood-brain barrier opening using a focused ultrasound system with acoustic feedback control

    by Chenchen Bing, Yu Hong, Christopher Hernandez, Megan Rich, Bingbing Cheng, Imalka Munaweera, Debra Szczepanski, Yin Xi, Mark Bolding, Agata Exner, et al.

    Focused ultrasound combined with bubble-based agents serves as a non-invasive way to open the blood-brain barrier (BBB). Passive acoustic detection was well studied recently to monitor the acoustic emissions induced by the bubbles under ultrasound energy, but the ability to perform reliable BBB opening with a real-time feedback control algorithm has not been fully evaluated. This study focuses on characterizing the acoustic emissions of different types of bubbles: Optison, Definity, and a custom-made nanobubble. Their performance on reliable BBB opening under real-time feedback control based on acoustic detection was evaluated bothin-vitroandin-vivo. The experiments were conducted using a 0.5 MHz focused ultrasound transducer within-vivofocal pressure ranges from 0.1–0.7 MPa. Successful feedback control was achieved with all three agents when combining with infusion injection. Localized opening was confirmed with Evans blue dye leakage. Microscopic images were acquired to review the opening effects. Under similar total gas volume, nanobubble showed a more reliable opening effect compared to Optison and Definity (p < 0.05). The conclusions obtained from this study confirm the possibilities of performing stable opening using a feedback control algorithm combined with infusion injection. It also opens another potential research area of BBB opening using sub-micron bubbles.


  • Drift correction for accurate PRF-shift MR thermometry during mild hyperthermia treatments with MR-HIFU

    by Chenchen Bing, Robert M. Staruch, Matti Tillander, Max O. Köhler, Charles Mougenot, Mika Ylihautala, Theodore W. Laetsch, Rajiv Chopra

    There is growing interest in performing hyperthermia treatments with clinical magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) therapy systems designed for tissue ablation. During hyperthermia treatment, however, due to the narrow therapeutic window (41–45 °C), careful evaluation of the accuracy of proton resonant frequency (PRF) shift MR thermometry for these types of exposures is required. Purpose: The purpose of this study was to evaluate the accuracy of MR thermometry using a clinical MR-HIFU system equipped with a hyperthermia treatment algorithm. Methods: Mild heating was performed in a tissue-mimicking phantom with implanted temperature sensors using the clinical MR-HIFU system. The influence of image-acquisition settings and post-acquisition correction algorithms on the accuracy of temperature measurements was investigated. The ability to achieve uniform heating for up to 40 min was evaluated in rabbit experiments. Results: Automatic centre-frequency adjustments prior to image-acquisition corrected the image-shifts in the order of 0.1 mm/min. Zero- and first-order phase variations were observed over time, supporting the use of a combined drift correction algorithm. The temperature accuracy achieved using both centre-frequency adjustment and the combined drift correction algorithm was 0.57° ± 0.58 °C in the heated region and 0.54° ± 0.42 °C in the unheated region. Conclusion: Accurate temperature monitoring of hyperthermia exposures using PRF shift MR thermometry is possible through careful implementation of image-acquisition settings and drift correction algorithms. For the evaluated clinical MR-HIFU system, centre-frequency adjustment eliminated image shifts, and a combined drift correction algorithm achieved temperature measurements with an acceptable accuracy for monitoring and controlling hyperthermia exposures.


  • Open Access

    Trans-cranial opening of the blood-brain barrier in targeted regions using astereotaxic brain atlas and focused ultrasound energy

    by Chenchen Bing, Michelle Ladouceur-Wodzak, Clinton R Wanner, John M Shelton, James A Richardson, Rajiv Chopra

    The blood-brain barrier (BBB) protects the brain by preventing the entry of largemolecules; this poses a major obstacle for the delivery of drugs to the brain. Anovel technique using focused ultrasound (FUS) energy combined with microbubblecontrast agents has been widely used for non-invasive trans-cranial BBB opening.Traditionally, FUS research is conducted with magnetic resonance imaging (MRI)guidance, which is expensive and poses physical limitations due to the magneticfield. A system that could allow researchers to test brain therapies without MRintervention could facilitate and accelerate translational research. In this study, we present a novel FUS system that uses a custom-built FUSgenerator mounted on a motorized stereotaxic apparatus with embedded brain atlasto locally open the BBB in rodents. The system was initially characterized using atissue-mimicking phantom. Rodent studies were also performed to evaluate whethernon-invasive, localized BBB opening could be achieved using brain atlas-basedtargeting. Brains were exposed to pulsed focused ultrasound energy at1.06 MHz in rats and 3.23 MHz in mice, with the focal pressure estimatedto be 0.5–0.6 MPa through the skull. BBB opening was confirmed in grosstissue sections by the presence of Evans blue leakage in the exposed region of thebrain and by histological assessment. The targeting accuracy of the stereotaxic system was better than 0.5 mm inthe tissue-mimicking phantom. Reproducible localized BBB opening was verified withEvans blue dye leakage in 32/33 rats and had a targeting accuracy of±0.3 mm. The use of higher frequency exposures in mice enabled a similarprecision of localized BBB opening as was observed with the low frequency in therat model. With this dedicated small-animal motorized stereotaxic-FUS system, we achievedaccurate targeting of focused ultrasound exposures in the brain for non-invasiveopening of the BBB. This system can be used as an alternative to MR-guided FUS andoffers researchers the ability to perform efficient studies (30 min perexperiment including preparation) at a reduced cost in a conventional laboratoryenvironment.