Charles Mougenot
Research Subjects
Charles Mougenot has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Adam C. Waspe
Centre for Image Guided Innovation and Therapeutic Intervention, Hospital for Sick Children, Toronto, Ontario, Canada
1 shared publication - Ari Partanen
Profound Medical, Mississauga, Ontario, CANADA
1 shared publication - Benjamin Zaporzan
Thunder Bay Regional Research Institute, Thunder Bay, Ontario P7B 6V4, Canada ; Electrical Engineering, Lakehead University, Thunder Bay, Ontario P7B 5E1, Canada
1 shared publication - Bruno Quesson
CHU Bordeaux, IHU Lyric, Université de Bordeaux, Bordeaux, France
1 shared publication C. Moonen
1 shared publication- Chenchen Bing
A Department of Radiology , UT Southwestern Medical Center , Dallas , TX , USA
1 shared publication
Latest Publications
- 22 May 2016
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 32 (6) , 673-687
Drift correction for accurate PRF-shift MR thermometry during mild hyperthermia treatments with MR-HIFU
There is growing interest in performing hyperthermia treatments with clinical magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) therapy systems designed for tissue ablation. During hyperthermia treatment, however, due to the narrow therapeutic window (41–45 °C), careful evaluation of the accuracy of proton resonant frequency (PRF) shift MR thermometry for these types of exposures is required. Purpose: The purpose of this study was to evaluate the accuracy of MR thermometry using a clinical MR-HIFU system equipped with a hyperthermia treatment algorithm. Methods: Mild heating was performed in a tissue-mimicking phantom with implanted temperature sensors using the clinical MR-HIFU system. The influence of image-acquisition settings and post-acquisition correction algorithms on the accuracy of temperature measurements was investigated. The ability to achieve uniform heating for up to 40 min was evaluated in rabbit experiments. Results: Automatic centre-frequency adjustments prior to image-acquisition corrected the image-shifts in the order of 0.1 mm/min. Zero- and first-order phase variations were observed over time, supporting the use of a combined drift correction algorithm. The temperature accuracy achieved using both centre-frequency adjustment and the combined drift correction algorithm was 0.57° ± 0.58 °C in the heated region and 0.54° ± 0.42 °C in the unheated region. Conclusion: Accurate temperature monitoring of hyperthermia exposures using PRF shift MR thermometry is possible through careful implementation of image-acquisition settings and drift correction algorithms. For the evaluated clinical MR-HIFU system, centre-frequency adjustment eliminated image shifts, and a combined drift correction algorithm achieved temperature measurements with an acceptable accuracy for monitoring and controlling hyperthermia exposures.
- 22 May 2016
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 32 (6) , 673-687
Drift correction for accurate PRF-shift MR thermometry during mild hyperthermia treatments with MR-HIFU
There is growing interest in performing hyperthermia treatments with clinical magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) therapy systems designed for tissue ablation. During hyperthermia treatment, however, due to the narrow therapeutic window (41–45 °C), careful evaluation of the accuracy of proton resonant frequency (PRF) shift MR thermometry for these types of exposures is required. Purpose: The purpose of this study was to evaluate the accuracy of MR thermometry using a clinical MR-HIFU system equipped with a hyperthermia treatment algorithm. Methods: Mild heating was performed in a tissue-mimicking phantom with implanted temperature sensors using the clinical MR-HIFU system. The influence of image-acquisition settings and post-acquisition correction algorithms on the accuracy of temperature measurements was investigated. The ability to achieve uniform heating for up to 40 min was evaluated in rabbit experiments. Results: Automatic centre-frequency adjustments prior to image-acquisition corrected the image-shifts in the order of 0.1 mm/min. Zero- and first-order phase variations were observed over time, supporting the use of a combined drift correction algorithm. The temperature accuracy achieved using both centre-frequency adjustment and the combined drift correction algorithm was 0.57° ± 0.58 °C in the heated region and 0.54° ± 0.42 °C in the unheated region. Conclusion: Accurate temperature monitoring of hyperthermia exposures using PRF shift MR thermometry is possible through careful implementation of image-acquisition settings and drift correction algorithms. For the evaluated clinical MR-HIFU system, centre-frequency adjustment eliminated image shifts, and a combined drift correction algorithm achieved temperature measurements with an acceptable accuracy for monitoring and controlling hyperthermia exposures.
- Open Access
- 4 June 2013
- Published by Springer Nature in Journal of Therapeutic Ultrasound
- Vol. 1 (1) , 7
MatMRI and MatHIFU: software toolboxes for real-time monitoring and control of MR-guided HIFU
Background: The availability of open and versatile software tools is a key feature to facilitate pre-clinical research for magnetic resonance imaging (MRI) and magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) and expedite clinical translation of diagnostic and therapeutic medical applications. In the present study, two customizable software tools that were developed at the Thunder Bay Regional Research Institute are presented for use with both MRI and MR-HIFU. Both tools operate in a MATLAB®; environment. The first tool is named MatMRI and enables real-time, dynamic acquisition of MR images with a Philips MRI scanner. The second tool is named MatHIFU and enables the execution and dynamic modification of user-defined treatment protocols with the Philips Sonalleve MR-HIFU therapy system to perform ultrasound exposures in MR-HIFU therapy applications. Methods: MatMRI requires four basic steps: initiate communication, subscribe to MRI data, query for new images, and unsubscribe. MatMRI can also pause/resume the imaging and perform real-time updates of the location and orientation of images. MatHIFU requires four basic steps: initiate communication, prepare treatment protocol, and execute treatment protocol. MatHIFU can monitor the state of execution and, if required, modify the protocol in real time. Results: Four applications were developed to showcase the capabilities of MatMRI and MatHIFU to perform pre-clinical research. Firstly, MatMRI was integrated with an existing small animal MR-HIFU system (FUS Instruments, Toronto, Ontario, Canada) to provide real-time temperature measurements. Secondly, MatMRI was used to perform T2-based MR thermometry in the bone marrow. Thirdly, MatHIFU was used to automate acoustic hydrophone measurements on a per-element basis of the 256-element transducer of the Sonalleve system. Finally, MatMRI and MatHIFU were combined to produce and image a heating pattern that recreates the word ‘HIFU’ in a tissue-mimicking heating phantom. Conclusions: MatMRI and MatHIFU leverage existing MRI and MR-HIFU clinical platforms to facilitate pre-clinical research. MatMRI substantially simplifies the real-time acquisition and processing of MR data. MatHIFU facilitates the testing and characterization of new therapy applications using the Philips Sonalleve clinical MR-HIFU system. Under coordination with Philips Healthcare, both MatMRI and MatHIFU are intended to be freely available as open-source software packages to other research groups.
- 4 June 2013
- Published by Springer Nature in Journal of Therapeutic Ultrasound
- Vol. 1 (1) , 7
Open AccessMatMRI and MatHIFU: software toolboxes for real-time monitoring and control of MR-guided HIFU
Background: The availability of open and versatile software tools is a key feature to facilitate pre-clinical research for magnetic resonance imaging (MRI) and magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) and expedite clinical translation of diagnostic and therapeutic medical applications. In the present study, two customizable software tools that were developed at the Thunder Bay Regional Research Institute are presented for use with both MRI and MR-HIFU. Both tools operate in a MATLAB®; environment. The first tool is named MatMRI and enables real-time, dynamic acquisition of MR images with a Philips MRI scanner. The second tool is named MatHIFU and enables the execution and dynamic modification of user-defined treatment protocols with the Philips Sonalleve MR-HIFU therapy system to perform ultrasound exposures in MR-HIFU therapy applications. Methods: MatMRI requires four basic steps: initiate communication, subscribe to MRI data, query for new images, and unsubscribe. MatMRI can also pause/resume the imaging and perform real-time updates of the location and orientation of images. MatHIFU requires four basic steps: initiate communication, prepare treatment protocol, and execute treatment protocol. MatHIFU can monitor the state of execution and, if required, modify the protocol in real time. Results: Four applications were developed to showcase the capabilities of MatMRI and MatHIFU to perform pre-clinical research. Firstly, MatMRI was integrated with an existing small animal MR-HIFU system (FUS Instruments, Toronto, Ontario, Canada) to provide real-time temperature measurements. Secondly, MatMRI was used to perform T2-based MR thermometry in the bone marrow. Thirdly, MatHIFU was used to automate acoustic hydrophone measurements on a per-element basis of the 256-element transducer of the Sonalleve system. Finally, MatMRI and MatHIFU were combined to produce and image a heating pattern that recreates the word ‘HIFU’ in a tissue-mimicking heating phantom. Conclusions: MatMRI and MatHIFU leverage existing MRI and MR-HIFU clinical platforms to facilitate pre-clinical research. MatMRI substantially simplifies the real-time acquisition and processing of MR data. MatHIFU facilitates the testing and characterization of new therapy applications using the Philips Sonalleve clinical MR-HIFU system. Under coordination with Philips Healthcare, both MatMRI and MatHIFU are intended to be freely available as open-source software packages to other research groups.
- 19 March 2012
- Published by Wiley in Medical Physics
- Vol. 39 (4) , 1936-1945
High intensity focused ultrasound with large aperture transducers: A MRI based focal point correction for tissue heterogeneity
Purpose:: The risk of undesired tissue damage to thoracic cage, heart, and lung during MR guided HIFU ablations of breast cancer can be greatly reduced if a phased array transducer design with a lateral beam direction is used in combination with a large aperture. The disadvantage is an increased sensitivity to focus aberrations due to tissue heterogeneity. Here, the authors propose to restore the focal coherence by using a matched aperture phase correction, which is based on a noninvasively obtained tissue model.Methods:: The method combines high resolution MRI with ultrasound wave measurements of different tissue types to determine a phase correction, which compensates focal point aberrations caused by tissue heterogeneity. 3D segmentation of tissue is used to quantify the relative proportion of each tissue type along a line running from the center of each element of the phased array to the target focal point.Results:: For tissue types with a celerity difference of 3%, the proposed method allows to quantify the phase aberration with an accuracy of 6° ± 20° and a correlation factor R² = 0.95. Using the refocusing method for a complex heterogeneous phantom resulted in 95% of the maximal pressure, whereas only 70% of the maximal pressure is obtained in absence of any phase correction.Conclusions:: Since the proposed refocusing algorithm is compatible with a standard interventional preplanning and requires only a minimal amount of processing, it presents a promising approach to compensate for aberration in heterogeneous tissues such as the human breast.
- 19 March 2012
- Published by Wiley in Medical Physics
- Vol. 39 (4) , 1936-1945
High intensity focused ultrasound with large aperture transducers: A MRI based focal point correction for tissue heterogeneity
Purpose:: The risk of undesired tissue damage to thoracic cage, heart, and lung during MR guided HIFU ablations of breast cancer can be greatly reduced if a phased array transducer design with a lateral beam direction is used in combination with a large aperture. The disadvantage is an increased sensitivity to focus aberrations due to tissue heterogeneity. Here, the authors propose to restore the focal coherence by using a matched aperture phase correction, which is based on a noninvasively obtained tissue model.Methods:: The method combines high resolution MRI with ultrasound wave measurements of different tissue types to determine a phase correction, which compensates focal point aberrations caused by tissue heterogeneity. 3D segmentation of tissue is used to quantify the relative proportion of each tissue type along a line running from the center of each element of the phased array to the target focal point.Results:: For tissue types with a celerity difference of 3%, the proposed method allows to quantify the phase aberration with an accuracy of 6° ± 20° and a correlation factor R² = 0.95. Using the refocusing method for a complex heterogeneous phantom resulted in 95% of the maximal pressure, whereas only 70% of the maximal pressure is obtained in absence of any phase correction.Conclusions:: Since the proposed refocusing algorithm is compatible with a standard interventional preplanning and requires only a minimal amount of processing, it presents a promising approach to compensate for aberration in heterogeneous tissues such as the human breast.
- 20 December 2010
- Published by Wiley in Medical Physics
- Vol. 38 (1) , 272-282
Quantification of near‐field heating during volumetric MR‐HIFU ablation
Purpose: High‐intensity focused ultrasound guided by magnetic resonance imaging has been extensively evaluated during the past decade as a clinical alternative for thermal ablation of tumor tissue. However, the maximal ablation volume is limited by the extensive treatment duration resulting from the small size of the focal point as compared to the average tumor size. Volumetric sonication has been shown to efficiently enlarge the ablated volume per sonication, but remains limited by the temperature increase induced in the skin and fat layers. In this study, multiplane MR thermometry is proposed for monitoring the near‐field temperature rise in order to prevent related unintended thermal damage.Methods: The method was evaluated by performing sonications in the thigh muscle of 11 pigs maintained under general anesthesia. Volumetric ablations were performed by steering the focal point along trajectories consisting of multiple outward‐moving concentric circles. Near‐field heating was characterized with MR temperature maps and thermal dose maps. The results from the MR measurements were compared to simulations.Results: In this study, the measured maximum temperature rise was found to correlate linearly with the surface energy density within the near field of the beam path with a slope of. This simple linear model appears to be almost independent of the trajectory pattern and the sonication depth. The safety limit to avoid lethal damage of the subcutaneous tissues of the porcine thigh was identified to be an absolute temperature of , corresponding to a surface energy density of at 1.2 MHz.Conclusions: A linear relationship can be established to estimate the temperature increase based on the chosen power prior to ablation, thereby providing ana priori safety check for possible excessive near‐field heating using a known surface energy density threshold. This method would also give the clinician the possibility to abort the sonication should excessive near‐field temperature rise be seen before fat layer damage or skin burns are inflicted.
- 20 December 2010
- Published by Wiley in Medical Physics
- Vol. 38 (1) , 272-282
Quantification of near‐field heating during volumetric MR‐HIFU ablation
Purpose: High‐intensity focused ultrasound guided by magnetic resonance imaging has been extensively evaluated during the past decade as a clinical alternative for thermal ablation of tumor tissue. However, the maximal ablation volume is limited by the extensive treatment duration resulting from the small size of the focal point as compared to the average tumor size. Volumetric sonication has been shown to efficiently enlarge the ablated volume per sonication, but remains limited by the temperature increase induced in the skin and fat layers. In this study, multiplane MR thermometry is proposed for monitoring the near‐field temperature rise in order to prevent related unintended thermal damage.Methods: The method was evaluated by performing sonications in the thigh muscle of 11 pigs maintained under general anesthesia. Volumetric ablations were performed by steering the focal point along trajectories consisting of multiple outward‐moving concentric circles. Near‐field heating was characterized with MR temperature maps and thermal dose maps. The results from the MR measurements were compared to simulations.Results: In this study, the measured maximum temperature rise was found to correlate linearly with the surface energy density within the near field of the beam path with a slope of. This simple linear model appears to be almost independent of the trajectory pattern and the sonication depth. The safety limit to avoid lethal damage of the subcutaneous tissues of the porcine thigh was identified to be an absolute temperature of , corresponding to a surface energy density of at 1.2 MHz.Conclusions: A linear relationship can be established to estimate the temperature increase based on the chosen power prior to ablation, thereby providing ana priori safety check for possible excessive near‐field heating using a known surface energy density threshold. This method would also give the clinician the possibility to abort the sonication should excessive near‐field temperature rise be seen before fat layer damage or skin burns are inflicted.