Zhiqiang Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhiqiang Zhang has a total of 127 co-authors. Here are the top co-authors by number of shared publications:
- Weibao Qiu
Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences
24 shared publications - Hairong Zheng
Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
16 shared publications - Min Su
Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences
15 shared publications Rong Liu
Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences
13 shared publicationsXingying Wang
Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences
7 shared publications- Yanyan Yu
National-Reginal Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory of Biomedical Measurements and Ultrasound Imaging, the School of Biomedical Engineering, and Shenzhen University Medical School, Shenzhen University, Shenzhen, China
5 shared publications
Latest Publications
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. PP, 1
A Dual-mode Ultrasound Transducer Based on Textured Ceramic for Image-guided Interstitial Ablationn
Ultrasound image-guided interstitial ablation is an economical and effective way in the management of unresectable tumors and other pathologically compromised tissues. However, in clinical practice, extracorporeal ultrasound imaging guidance presents challenges in target localization, while interstitial ultrasound imaging increases system complexity. The integrated dual-mode transducer that combines imaging and therapeutic capabilities emerges as an optimal solution. Due to inherent limitations of piezoelectric materials-such as the trade-offs among piezoelectric and dielectric properties-conventional dual-mode transducers generally face a compromise between imaging quality and ablation efficacy. To address these technical challenges, we have developed a miniature dual-mode ultrasound transducer based on a novel textured Pb(In1/2Nb1/2)O3-Pb(Sc1/2Nb1/2)O3-PbTiO3 (PIN-PSN-PT) ceramic with superior performance in both ultrasound imaging and therapeutic ablation. The proposed dual-mode transducer exhibited a center frequency of 6.84 MHz along with a broad fractional bandwidth of 92%. An ultrahigh negative acoustic pressure of 2.9 MPa was obtained under an excitation voltage of 50 Vpp with corresponding spatial-peak pulse-average intensity of 272.6 W·cm-2. This work presents a paradigm for high-performance dual-mode transducer and highlights the potential of textured PIN-PSN-PT ceramic for integrated diagnostic imaging and therapeutic applications. These results provide essential technical support for future clinical translation.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. PP, 1
A Dual-mode Ultrasound Transducer Based on Textured Ceramic for Image-guided Interstitial Ablationn
Ultrasound image-guided interstitial ablation is an economical and effective way in the management of unresectable tumors and other pathologically compromised tissues. However, in clinical practice, extracorporeal ultrasound imaging guidance presents challenges in target localization, while interstitial ultrasound imaging increases system complexity. The integrated dual-mode transducer that combines imaging and therapeutic capabilities emerges as an optimal solution. Due to inherent limitations of piezoelectric materials-such as the trade-offs among piezoelectric and dielectric properties-conventional dual-mode transducers generally face a compromise between imaging quality and ablation efficacy. To address these technical challenges, we have developed a miniature dual-mode ultrasound transducer based on a novel textured Pb(In1/2Nb1/2)O3-Pb(Sc1/2Nb1/2)O3-PbTiO3 (PIN-PSN-PT) ceramic with superior performance in both ultrasound imaging and therapeutic ablation. The proposed dual-mode transducer exhibited a center frequency of 6.84 MHz along with a broad fractional bandwidth of 92%. An ultrahigh negative acoustic pressure of 2.9 MPa was obtained under an excitation voltage of 50 Vpp with corresponding spatial-peak pulse-average intensity of 272.6 W·cm-2. This work presents a paradigm for high-performance dual-mode transducer and highlights the potential of textured PIN-PSN-PT ceramic for integrated diagnostic imaging and therapeutic applications. These results provide essential technical support for future clinical translation.
- Open Access
- 6 August 2025
- Published by Elsevier in The Innovation
- Vol. 7 (1)
Stepped 2D array needle transducer for 4D ultrasound imaging-guided spinal puncture
- 6 August 2025
- Published by Elsevier in The Innovation
- Vol. 7 (1)
Open AccessStepped 2D array needle transducer for 4D ultrasound imaging-guided spinal puncture
- 10 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (3) , 380-389
Time-Sharing Acoustic Tweezers for Parallel Manipulation of Multiple Particles
Holographic acoustic tweezers have various biomedical applications due to their ability to flexibly and rapidly synthesize acoustic fields for manipulating single or multiple particles. Existing multi-particle manipulation techniques are usually realized by precisely designing the incident wave’s phase distribution to synthesize a complex and steady-state acoustic field containing multiple acoustic trapping beams. However, interference effects between multiple beams tend to produce artifacts that trap particles in unwanted positions, limiting accuracy and the number of manipulated particles. In addition, those techniques can only holistically manipulate multiple particles, namely lacking parallel working ability. In this study, we proposed a time-sharing acoustic tweezers method to achieve the manipulation of multiple particles by rapidly switching individual trapping beams, minimizing interference artifacts. We applied this method to a 256-element phased-array acoustic tweezer system with designed ultrasonic pulse sequences to synthesize a single focused, twin trap, and vortex beam, enabling the pseudo-parallel manipulation of multiple particles in three-dimensional space at a beam switching frequency of ≥ 10 kHz. The experiments on polydimethylsiloxane particles ranging from micrometers to millimeters in diameter demonstrated that up to 96 particles can be successfully trapped and assembled into a two-dimensional lattice. Different numbers of particles were also patterned into dynamic contours, such as sinusoidal vibration (10 particles) and butterfly flapping (24 particles). Additionally, the trapped multiple particles also can be rotated around their respective orbits. The proposed technique improved the number of objects dynamically manipulated in a parallel manner, advancing holographic acoustic tweezers and their applications.
- 10 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (3) , 380-389
Time-Sharing Acoustic Tweezers for Parallel Manipulation of Multiple Particles
Holographic acoustic tweezers have various biomedical applications due to their ability to flexibly and rapidly synthesize acoustic fields for manipulating single or multiple particles. Existing multi-particle manipulation techniques are usually realized by precisely designing the incident wave’s phase distribution to synthesize a complex and steady-state acoustic field containing multiple acoustic trapping beams. However, interference effects between multiple beams tend to produce artifacts that trap particles in unwanted positions, limiting accuracy and the number of manipulated particles. In addition, those techniques can only holistically manipulate multiple particles, namely lacking parallel working ability. In this study, we proposed a time-sharing acoustic tweezers method to achieve the manipulation of multiple particles by rapidly switching individual trapping beams, minimizing interference artifacts. We applied this method to a 256-element phased-array acoustic tweezer system with designed ultrasonic pulse sequences to synthesize a single focused, twin trap, and vortex beam, enabling the pseudo-parallel manipulation of multiple particles in three-dimensional space at a beam switching frequency of ≥ 10 kHz. The experiments on polydimethylsiloxane particles ranging from micrometers to millimeters in diameter demonstrated that up to 96 particles can be successfully trapped and assembled into a two-dimensional lattice. Different numbers of particles were also patterned into dynamic contours, such as sinusoidal vibration (10 particles) and butterfly flapping (24 particles). Additionally, the trapped multiple particles also can be rotated around their respective orbits. The proposed technique improved the number of objects dynamically manipulated in a parallel manner, advancing holographic acoustic tweezers and their applications.
- Open Access
- 4 December 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-14
Transparent ultrasonic transducers based on relaxor ferroelectric crystals for advanced photoacoustic imaging
Photoacoustic imaging is a promising non-invasive functional imaging modality for fundamental research and clinical diagnosis. However, achieving capillary-level resolution, wide field-of-view, and high frame rates remains challenging. To address this, we propose a transparent ultrasonic transducer design using our developed transparent Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3 crystals. Our fabrication technique incorporates quartz-glass-and-epoxy matching layers with low-resistance indium-tin-oxide electrodes through a brass-ring based structure, enabling a high frequency (28.5 MHz), wide bandwidth (78%), and enhanced pulse-echo sensitivity (2.5 V under 2-μJ pulse excitation). Our Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3-based transparent ultrasonic transducer demonstrates a four-fold enhancement in photoacoustic detection sensitivity when compared to the LiNbO3-based counterpart, leading to a 13 dB improvement of signal-to-noise ratio in microvascular photoacoustic imaging. This enables dynamic monitoring of mouse cerebral cortex microvasculature during seizures at 0.8 Hz frame rates over a 1.5 × 1.5 mm2 field-of-view. Our work paves the way for high-performance and compact photoacoustic imaging systems using advanced piezoelectric materials.
- 4 December 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-14
Open AccessTransparent ultrasonic transducers based on relaxor ferroelectric crystals for advanced photoacoustic imaging
Photoacoustic imaging is a promising non-invasive functional imaging modality for fundamental research and clinical diagnosis. However, achieving capillary-level resolution, wide field-of-view, and high frame rates remains challenging. To address this, we propose a transparent ultrasonic transducer design using our developed transparent Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3 crystals. Our fabrication technique incorporates quartz-glass-and-epoxy matching layers with low-resistance indium-tin-oxide electrodes through a brass-ring based structure, enabling a high frequency (28.5 MHz), wide bandwidth (78%), and enhanced pulse-echo sensitivity (2.5 V under 2-μJ pulse excitation). Our Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3-based transparent ultrasonic transducer demonstrates a four-fold enhancement in photoacoustic detection sensitivity when compared to the LiNbO3-based counterpart, leading to a 13 dB improvement of signal-to-noise ratio in microvascular photoacoustic imaging. This enables dynamic monitoring of mouse cerebral cortex microvasculature during seizures at 0.8 Hz frame rates over a 1.5 × 1.5 mm2 field-of-view. Our work paves the way for high-performance and compact photoacoustic imaging systems using advanced piezoelectric materials.
- 2 December 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 22 (6)
Parallel droplet ejection with artificial-structure-based holographic acoustic fields
- 2 December 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 22 (6)
Parallel droplet ejection with artificial-structure-based holographic acoustic fields
- 14 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (4) , 1298-1305
A Novel Coded Excitation Imaging Platform for Ultra-High Frequency (>100 MHz) Ultrasound Applications
Ultra-high frequency (UHF, >100 MHz) ultrasound imaging has significant potential applications in musculoskeletal anatomy, skin, oral mucosa, and the eyes as a new high-resolution imaging technique. However, large acoustic attenuation of biological tissues greatly limits the depth of penetration of UHF ultrasound. Improving penetration depth while maintaining high-definition images is of clinical importance for UHF ultrasound imaging. Coded excitation imaging is known to be an effective method to increase the penetration depth of high-frequency ultrasound. Nevertheless, the feasibility of this technique has not yet been established in UHF ultrasound imaging. In addition, conventional coded excitation imaging systems are bulky, expensive, and lack flexibility. In this study, we propose a coded excitation imaging platform for UHF ultrasound. The platform integrates a high-performance ultrasound transmitter and a high sampling rate signal receiver to enable UHF ultrasound applications. A UHF ultrasound transducer was developed using LiNbO3 with a center frequency of 121.5 MHz to validate the imaging performance of the platform. High voltage short pulse and chirp coded pulse are used for the imaging, and the data show that the proposed coded method improved the signal-to-noise ratio (SNR) by nearly 10 dB at a similar spatial resolution. The results indicate that this platform has promising applications in UHF ultrasound imaging.
- 14 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (4) , 1298-1305
A Novel Coded Excitation Imaging Platform for Ultra-High Frequency (>100 MHz) Ultrasound Applications
Ultra-high frequency (UHF, >100 MHz) ultrasound imaging has significant potential applications in musculoskeletal anatomy, skin, oral mucosa, and the eyes as a new high-resolution imaging technique. However, large acoustic attenuation of biological tissues greatly limits the depth of penetration of UHF ultrasound. Improving penetration depth while maintaining high-definition images is of clinical importance for UHF ultrasound imaging. Coded excitation imaging is known to be an effective method to increase the penetration depth of high-frequency ultrasound. Nevertheless, the feasibility of this technique has not yet been established in UHF ultrasound imaging. In addition, conventional coded excitation imaging systems are bulky, expensive, and lack flexibility. In this study, we propose a coded excitation imaging platform for UHF ultrasound. The platform integrates a high-performance ultrasound transmitter and a high sampling rate signal receiver to enable UHF ultrasound applications. A UHF ultrasound transducer was developed using LiNbO3 with a center frequency of 121.5 MHz to validate the imaging performance of the platform. High voltage short pulse and chirp coded pulse are used for the imaging, and the data show that the proposed coded method improved the signal-to-noise ratio (SNR) by nearly 10 dB at a similar spatial resolution. The results indicate that this platform has promising applications in UHF ultrasound imaging.
- 3 September 2024
- Published by Elsevier in Ultrasonics
- Vol. 145, 107448
Fast acoustic droplet ejection based on annular array transducer
- 3 September 2024
- Published by Elsevier in Ultrasonics
- Vol. 145, 107448
Fast acoustic droplet ejection based on annular array transducer
- 25 August 2024
- Published by Elsevier in Ultrasonics
- Vol. 144, 107446
An adaptive spatiotemporal filter for ultrasound localization microscopy based on density canopy clustering
- 25 August 2024
- Published by Elsevier in Ultrasonics
- Vol. 144, 107446
An adaptive spatiotemporal filter for ultrasound localization microscopy based on density canopy clustering
- 20 July 2024
- Published by Elsevier in Ultrasonics
- Vol. 143, 107405
A transcranial multiple waves suppression method for plane wave imaging based on Radon transform
- 20 July 2024
- Published by Elsevier in Ultrasonics
- Vol. 143, 107405
A transcranial multiple waves suppression method for plane wave imaging based on Radon transform
- 22 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (5) , 1628-1639
A New Method of Plane-Wave Ultrasound Imaging Based on Reverse Time Migration
Coherent plane-wave compounding technique enables rapid ultrasound imaging with comparable image quality to traditional B-mode imaging that relies on focused beam transmission. However, existing methods assume homogeneity in the imaged medium, neglecting the heterogeneity in sound velocities and densities present in real tissues, resulting in noise reverberation. This study introduces the Reverse Time Migration (RTM) method for ultrasound plane-wave imaging to overcome this limitation, which is combined with a method for estimating the speed of sound in layered media. Simulation results in a homogeneous background demonstrate that RTM reduces side lobes and grating lobes by approximately 30 dB, enhancing the contrast-to-noise ratio by 20% compared to conventional delay and sum (DAS) beamforming. Moreover, RTM achieves superior imaging outcomes with fewer compounding angles. The lateral resolution of the RTM with 5–9 angle compounding is able to achieve the effectiveness of the DAS method with 15–19 angle compounding, and the CNR of the RTM with 11-angle compounding is almost the same as that of the DAS with 21-angle compounding. In a heterogeneous background, experimental simulations and in vitro wire phantom experiments confirm RTM's capability to correct depth imaging, focusing reflected waves on point targets. In vitro porcine tissue experiments enable accurate imaging of layer interfaces by estimating the velocities of multiple layers containing muscle and fat. The proposed imaging procedure optimizes velocity estimation in complex media, compensates for the impact of velocity differences, provides more reliable imaging results.
- 22 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (5) , 1628-1639
A New Method of Plane-Wave Ultrasound Imaging Based on Reverse Time Migration
Coherent plane-wave compounding technique enables rapid ultrasound imaging with comparable image quality to traditional B-mode imaging that relies on focused beam transmission. However, existing methods assume homogeneity in the imaged medium, neglecting the heterogeneity in sound velocities and densities present in real tissues, resulting in noise reverberation. This study introduces the Reverse Time Migration (RTM) method for ultrasound plane-wave imaging to overcome this limitation, which is combined with a method for estimating the speed of sound in layered media. Simulation results in a homogeneous background demonstrate that RTM reduces side lobes and grating lobes by approximately 30 dB, enhancing the contrast-to-noise ratio by 20% compared to conventional delay and sum (DAS) beamforming. Moreover, RTM achieves superior imaging outcomes with fewer compounding angles. The lateral resolution of the RTM with 5–9 angle compounding is able to achieve the effectiveness of the DAS method with 15–19 angle compounding, and the CNR of the RTM with 11-angle compounding is almost the same as that of the DAS with 21-angle compounding. In a heterogeneous background, experimental simulations and in vitro wire phantom experiments confirm RTM's capability to correct depth imaging, focusing reflected waves on point targets. In vitro porcine tissue experiments enable accurate imaging of layer interfaces by estimating the velocities of multiple layers containing muscle and fat. The proposed imaging procedure optimizes velocity estimation in complex media, compensates for the impact of velocity differences, provides more reliable imaging results.