MSMin Su

Min Su

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Min Su has a total of 108 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Dual-mode Ultrasound Transducer Based on Textured Ceramic for Image-guided Interstitial Ablationn

    by Li Ning, Chao Wang, Shuai Yang, Rong Liu, Haoyang Chen, Zheng Song, Le Gao, Xingying Wang, Min Su, Weichang Wu, et al.

    Ultrasound image-guided interstitial ablation is an economical and effective way in the management of unresectable tumors and other pathologically compromised tissues. However, in clinical practice, extracorporeal ultrasound imaging guidance presents challenges in target localization, while interstitial ultrasound imaging increases system complexity. The integrated dual-mode transducer that combines imaging and therapeutic capabilities emerges as an optimal solution. Due to inherent limitations of piezoelectric materials-such as the trade-offs among piezoelectric and dielectric properties-conventional dual-mode transducers generally face a compromise between imaging quality and ablation efficacy. To address these technical challenges, we have developed a miniature dual-mode ultrasound transducer based on a novel textured Pb(In1/2Nb1/2)O3-Pb(Sc1/2Nb1/2)O3-PbTiO3 (PIN-PSN-PT) ceramic with superior performance in both ultrasound imaging and therapeutic ablation. The proposed dual-mode transducer exhibited a center frequency of 6.84 MHz along with a broad fractional bandwidth of 92%. An ultrahigh negative acoustic pressure of 2.9 MPa was obtained under an excitation voltage of 50 Vpp with corresponding spatial-peak pulse-average intensity of 272.6 W·cm-2. This work presents a paradigm for high-performance dual-mode transducer and highlights the potential of textured PIN-PSN-PT ceramic for integrated diagnostic imaging and therapeutic applications. These results provide essential technical support for future clinical translation.

  • Time-Sharing Acoustic Tweezers for Parallel Manipulation of Multiple Particles

    by Juan Zhou, Laixin Huang, Min Su, Zhiqiang Zhang, Weibao Qiu, Fei Li, Hairong Zheng

    Holographic acoustic tweezers have various biomedical applications due to their ability to flexibly and rapidly synthesize acoustic fields for manipulating single or multiple particles. Existing multi-particle manipulation techniques are usually realized by precisely designing the incident wave’s phase distribution to synthesize a complex and steady-state acoustic field containing multiple acoustic trapping beams. However, interference effects between multiple beams tend to produce artifacts that trap particles in unwanted positions, limiting accuracy and the number of manipulated particles. In addition, those techniques can only holistically manipulate multiple particles, namely lacking parallel working ability. In this study, we proposed a time-sharing acoustic tweezers method to achieve the manipulation of multiple particles by rapidly switching individual trapping beams, minimizing interference artifacts. We applied this method to a 256-element phased-array acoustic tweezer system with designed ultrasonic pulse sequences to synthesize a single focused, twin trap, and vortex beam, enabling the pseudo-parallel manipulation of multiple particles in three-dimensional space at a beam switching frequency of ≥ 10 kHz. The experiments on polydimethylsiloxane particles ranging from micrometers to millimeters in diameter demonstrated that up to 96 particles can be successfully trapped and assembled into a two-dimensional lattice. Different numbers of particles were also patterned into dynamic contours, such as sinusoidal vibration (10 particles) and butterfly flapping (24 particles). Additionally, the trapped multiple particles also can be rotated around their respective orbits. The proposed technique improved the number of objects dynamically manipulated in a parallel manner, advancing holographic acoustic tweezers and their applications.


  • A Novel Coded Excitation Imaging Platform for Ultra-High Frequency (>100 MHz) Ultrasound Applications

    by Baoqiang Liu, Min Su, Zhiqiang Zhang, Lei Sun, Yanyan Yu, Weibao Qiu

    Ultra-high frequency (UHF, >100 MHz) ultrasound imaging has significant potential applications in musculoskeletal anatomy, skin, oral mucosa, and the eyes as a new high-resolution imaging technique. However, large acoustic attenuation of biological tissues greatly limits the depth of penetration of UHF ultrasound. Improving penetration depth while maintaining high-definition images is of clinical importance for UHF ultrasound imaging. Coded excitation imaging is known to be an effective method to increase the penetration depth of high-frequency ultrasound. Nevertheless, the feasibility of this technique has not yet been established in UHF ultrasound imaging. In addition, conventional coded excitation imaging systems are bulky, expensive, and lack flexibility. In this study, we propose a coded excitation imaging platform for UHF ultrasound. The platform integrates a high-performance ultrasound transmitter and a high sampling rate signal receiver to enable UHF ultrasound applications. A UHF ultrasound transducer was developed using LiNbO3 with a center frequency of 121.5 MHz to validate the imaging performance of the platform. High voltage short pulse and chirp coded pulse are used for the imaging, and the data show that the proposed coded method improved the signal-to-noise ratio (SNR) by nearly 10 dB at a similar spatial resolution. The results indicate that this platform has promising applications in UHF ultrasound imaging.


  • Open Access

    Deep-subwavelength ultrasonic imaging by MHz column-structured metalens: First evidence of quantitative visualization of subsurface defects

    by Shuxiao Zhang, Shifeng Guo, Yehai Li, Huanqing Cao, Min Su, Zhijun Yao, Wei Feng

    High-resolution ultrasonic imaging, which is highly demanded in nondestructive evaluation, is inherently limited by the detection wavelength. Acoustic metamaterial is an emerging technique to achieve subwavelength-resolution ultrasonic imaging beyond the diffraction limit due to its unprecedented acoustic properties. However, existing reports focus on metalenses for manipulating acoustic waves propagating in fluids like air and water, typically at a low-frequency range below 10 kHz. In this paper, a 0.5 MHz periodic column-structured metalens is designed and fabricated to realize deep-subwavelength ultrasonic imaging for quantitive visualization of subsurface defects in solid structures. The silicon-based metalens is designed based on Fabry–Pérot resonance theory. It consists of silicon columns arranged periodically with a lattice constant of 0.2 mm. The Fabry–Pérot resonance frequency is analyzed theoretically and the wave fields of the metalens at resonance mode are verified numerically. The subwavelength ultrasonic imaging performance of the proposed metalens is numerically proved and experimentally demonstrated. As a result, super-resolution ultrasonic imaging (λ/30, with λ being the wavelength) with a high resolving contrast is realized to identify two separated subsurface defects in a stainless-steel structure experimentally with the designed column-structured metalens. This work demonstrates a valuable deep-subwavelength imaging method that beyond traditional diffraction limits and paves the way for enhanced applications in nondestructive evaluation and biomedical diagnosis.


  • Portal Vein Pressure Estimation and Portal Hypertension Discrimination Based on Subharmonic Scattering of Ultrasound Contrast Agent Microbubbles

    by Gang Xu, Yun Wang, Huimin Lu, Changcan Li, Laixin Huang, Min Su, Huayu Yang, Deyu Li, Weibao Qiu, Minghao Sun, et al.

    Objective: The acquisition of real-time portal vein pressure (PVP) is important for portal hypertension (PH) discrimination to monitor disease progress and select treatment options. To date, the PVP evaluation approaches are either invasive or noninvasive but with less stability and sensitivity. Methods : We customized an open ultrasound scanner to explore in vitro and in vivo the ultrasound contrast agent SonoVue microbubbles’ subharmonic characteristics with acoustic pressure and local ambient pressure, and obtained promising results of PVP measurements in canine models with induced PH by ligation or embolization of portal vein. Results: In in vitro experiments, the highest correlations between the subharmonic amplitude of SonoVue microbubbles and ambient pressure were observed at acoustic pressures of 523 kPa and 563 kPa (r = −0.993, −0.993, P 16 mmHg) diagnostic capacity also achieved a high level (563 kPa, sensitivity = 93.3%, specificity = 91.7%, accuracy = 92.6%). Conclusion: This study proposes a promising measurement for PVP with the highest accuracy, sensitivity, and specificity in an in vivo model compared to existing studies. Future investigations are planned to assess the feasibility of this technique in clinical practice. Significance: This is the first study that comprehensively investigates the role of the subharmonic scattering signals from SonoVue microbubbles in evaluating PVP in vivo. It represents a promising alternative to invasive measurements for portal pressure.


  • Top Cited Papers
    Open Access

    Modulation of deep neural circuits with sonogenetics

    by Quanxiang Xian, Zhihai Qiu, Suresh Murugappan, Shashwati Kala, Kin Fung Wong, Danni Li, Guofeng Li, Yizhou Jiang, Yong Wu, Min Su, et al.

    Noninvasive control of neuronal activity in the deep brain can be illuminating for probing brain function and treating dysfunctions. Here, we present a sonogenetic approach for controlling distinct mouse behavior with circuit specificity and subsecond temporal resolution. Targeted neurons in subcortical regions were made to express a mutant large conductance mechanosensitive ion channel (MscL-G22S), enabling ultrasound to trigger activity in MscL-expressing neurons in the dorsal striatum and increase locomotion in freely moving mice. Ultrasound stimulation of MscL-expressing neurons in the ventral tegmental area could activate the mesolimbic pathway to trigger dopamine release in the nucleus accumbens and modulate appetitive conditioning. Moreover, sonogenetic stimulation of the subthalamic nuclei of Parkinson’s disease model mice improved their motor coordination and mobile time. Neuronal responses to ultrasound pulse trains were rapid, reversible, and repeatable. We also confirmed that the MscL-G22S mutant is more effective to sensitize neurons to ultrasound compared to the wild-type MscL. Altogether, we lay out a sonogenetic approach which can selectively manipulate targeted cells to activate defined neural pathways, affect specific behaviors, and relieve symptoms of neurodegenerative disease.


  • Open Access

    Noninvasive Estimation of Tumor Interstitial Fluid Pressure from Subharmonic Scattering of Ultrasound Contrast Microbubbles

    by Yun Wang, Huimin Lu, Laixin Huang, Deyu Li, Weibao Qiu, Lingling Li, Gang Xu, Min Su, Jianhua Zhou, Fei Li

    The noninvasive estimation of interstitial fluid pressure (IFP) using ultrasound contrast agent (UCA) microbubbles as pressure sensors will provide tumor treatments and efficacy assessments with a promising tool. This study aimed to verify the efficacy of the optimal acoustic pressure in vitro in the prediction of tumor IFPs based on UCA microbubbles’ subharmonic scattering. A customized ultrasound scanner was used to generate subharmonic signals from microbubbles’ nonlinear oscillations, and the optimal acoustic pressure was determined in vitro when the subharmonic amplitude reached the most sensitive to hydrostatic pressure changes. This optimal acoustic pressure was then applied to predict IFPs in tumor-bearing mouse models, which were further compared with the reference IFPs measured using a standard tissue fluid pressure monitor. An inverse linear relationship and good correlation (r = −0.853, p < 0.001) existed between the subharmonic amplitude and tumor IFPs at the optimal acoustic pressure of 555 kPa, and pressure sensitivity was 1.019 dB/mmHg. No statistical differences were found between the pressures measured by the standard device and those estimated via the subharmonic amplitude, as confirmed by cross-validation (mean absolute errors from 2.00 to 3.09 mmHg, p > 0.05). Our findings demonstrated that in vitro optimized acoustic parameters for UCA microbubbles’ subharmonic scattering can be applied for the noninvasive estimation of tumor IFPs.


  • A Novel Dual-Element Catheter for Improving Non-Uniform Rotational Distortion in Intravascular Ultrasound

    by Baoqiang Liu, Min Su, Zhiqiang Zhang, Rong Liu, Lei Sun, Hairong Zheng, Weibao Qiu

    For the early diagnosis of atherosclerosis and interventions, intravascular ultrasound (IVUS) is a valuable tool for intravascular luminal imaging. Compared with the array-based method, mechanically rotating IVUS catheters dominate the clinical applications because of their less complexity and better suitability for high-frequency ultrasound imaging. However, mechanically rotating catheters are suffering from non-uniform rotational distortion (NURD) which hinders accurate image acquisition. In this study, a dual-element imaging catheter is proposed, in which two elements with the same frequency and similar performance are assembled in a back-to-back arrangement. When the catheter encounters a NURD due to acute bending, the abnormal image of one element can be replaced by the normal image of the opposite element, thus eliminating the NURD in the reconstructed image. Moreover, two images can be obtained in one rotation and the imaging frame rate is doubled in the absence of NURD. The performance of the two elements was quantitatively assessed by a wire phantom. And the complementary imaging protocols were evaluated by a tissue phantom and ex vivo porcine vessel. The results show that the proposed strategy can be promising in clinical studies.


  • High frequency focal transducer with a Fresnel zone plate for intravascular ultrasound

    by Min Su, Xiangxiang Xia, Baoqiang Liu, Zhiqiang Zhang, Rong Liu, Feiyan Cai, Weibao Qiu, Lei Sun

    The diameter of an intravascular ultrasound (IVUS) catheter is always less than 1 mm, because it must be inserted into a blood vessel to obtain ultrasound images. Owing to this requisite small size, it is difficult to perform geometric focusing on the surface of an IVUS transducer to improve the spatial resolution of the image. This study proposes a high frequency transducer with a Fresnel zone plate (FZP) for intravascular ultrasound imaging. Through theoretical calculations, the parameters and structure of the transducer are optimized for high-frequency ultrasound. The acoustic beam is simulated using COMSOL software. The aperture size of the ultrasound element is 0.778 × 0.9 mm2. Transducers with or without the FZP layer are designed and fabricated in this study. The center frequency and –6 dB bandwidth of the FZP transducer are 52.5 MHz and 42%, respectively. Meanwhile, the center frequency and –6 dB bandwidth of the plane-shape transducer are 51.3 MHz and 58%, respectively. Wire phantom and porcine artery imaging experiments were performed to evaluate the performance of the designed transducers. The spatial resolution of the FZP transducer is 46.8 μm axially and 183.6 μm laterally, and the resolution of the plane-shape transducer is 44.3 μm axially and 313.5 μm laterally. The results demonstrate that the FZP transducer provides superior lateral imaging resolution for IVUS applications.


  • Evaluation of Blood Induced Influence for High-Definition Intravascular Ultrasound (HD-IVUS)

    by Suzi Liang, Min Su, Baoqiang Liu, Rong Liu, Hairong Zheng, Weibao Qiu, Zhiqiang Zhang

    High-definition intravascular ultrasound (HD-IVUS) utilizing more than 80 MHz frequency to assess atherosclerotic plaque, can theoretically achieve an axial resolution of less than $20~\mu \text{m}$ . However, the blood is a high-attenuation source at high frequency, which would affect the imaging quality. There has been no research evaluating the blood-induced influence on HD-IVUS imaging. And whether a temporary removal of blood is needed for HD-IVUS is unknown. In this study, an ultrahigh-frequency (100 MHz) ultrasound transducer was developed to evaluate the blood-induced attenuation for HD-IVUS imaging. A series of tungsten-wire phantom images in saline and blood at varying hematocrits were obtained. The images showed that blood did influence the ultrahigh-frequency imaging quality greatly. The signal-to-noise ratio (SNR) decrease by 71.7% in porcine whole blood compared to that in saline at the same depth of 2.3 mm. Moreover, the potential flushing schemes for HD-IVUS were studied in varying hematocrits. Three flushing agents commonly used in intravascular optical coherence tomography (IV-OCT) were investigated, including iohexol, mannitol, and dextran 5% and saline as the control group. The attenuation of blood in varying hematocrits/flushing agents was measured from 90 to 110 MHz. The result indicated dextran 5% was a suitable flushing agent for HD-IVUS due to its less signal attenuation compared to others.