Jie Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jie Chen has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Alian Chen
School of Control Science and Engineering, Shandong University, Jinan, China
6 shared publications - Chenghui Zhang
Shandong University
5 shared publications - Xiangyang Xing
Shandong University, Jinan, China
5 shared publications - Changwei Qin
School of Information and Electrical Engineering and Shandong Key Laboratory of Smart Buildings and Energy Efficiency, Shandong Jianzhu University, Jinan, China
3 shared publications - Xiaoyan Li
School of Information and Electrical Engineering and Shandong Key Laboratory of Smart Buildings and Energy Efficiency, Shandong Jianzhu University, Jinan, China
2 shared publications Cen Gao
Institute of Microelectronics of the Chinese Academy of Sciences, Beijing, China
1 shared publication
Latest Publications
- 19 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (5) , 4890-4900
Optimal Current Ripple PWM for Three-Level Inverter With Common Mode Voltage Reduction
Three-level inverter has been widely used in electric drives and renewable power generation system. However, the common mode voltage (CMV) and output current ripple reduction of a three-level inverter should be carefully regulated for the appropriate operation. As these two targets are mutually interrelated, the conventional space vector modulation (SVM) scheme cannot cope with them decently. To overcome this drawback, this article proposes a novel modified SVM scheme to realize CMV and current ripple reduction simultaneously. The generating mechanism of output current ripple is analyzed, and the relationship between current ripple and utilized vectors is quantitatively described. Based on the analyses, the proposed optimal current ripple and CMV reduction pulsewidth modulation (OCR-CMVRPWM) method adopts four voltage vectors (large, medium, small, and zero vectors) to reduce the root mean square value of current ripple by allocating the sequence and dwell times of utilized vectors. Compared to the existing PWM methods, the proposed OCR-CMVRPWM scheme can reduce the peak of CMV to half of the value using the conventional SVM, and obtain a significant reduction of output current total harmonic distortion. The effectiveness of the proposed method is validated by both simulation and experimental results.
- 19 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (5) , 4890-4900
Optimal Current Ripple PWM for Three-Level Inverter With Common Mode Voltage Reduction
Three-level inverter has been widely used in electric drives and renewable power generation system. However, the common mode voltage (CMV) and output current ripple reduction of a three-level inverter should be carefully regulated for the appropriate operation. As these two targets are mutually interrelated, the conventional space vector modulation (SVM) scheme cannot cope with them decently. To overcome this drawback, this article proposes a novel modified SVM scheme to realize CMV and current ripple reduction simultaneously. The generating mechanism of output current ripple is analyzed, and the relationship between current ripple and utilized vectors is quantitatively described. Based on the analyses, the proposed optimal current ripple and CMV reduction pulsewidth modulation (OCR-CMVRPWM) method adopts four voltage vectors (large, medium, small, and zero vectors) to reduce the root mean square value of current ripple by allocating the sequence and dwell times of utilized vectors. Compared to the existing PWM methods, the proposed OCR-CMVRPWM scheme can reduce the peak of CMV to half of the value using the conventional SVM, and obtain a significant reduction of output current total harmonic distortion. The effectiveness of the proposed method is validated by both simulation and experimental results.
- 18 January 2021
- Published by Springer Nature in Analog Integrated Circuits and Signal Processing
- Vol. 108 (1) , 89-99
A 15.5x-gain 0.29-mm2 CMOS readout circuit for 1.5-Mpixel 60-fps CMOS image sensor
- 18 January 2021
- Published by Springer Nature in Analog Integrated Circuits and Signal Processing
- Vol. 108 (1) , 89-99
A 15.5x-gain 0.29-mm2 CMOS readout circuit for 1.5-Mpixel 60-fps CMOS image sensor
- 20 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 67 (10) , 8980-8990
Double Vector Model Predictive Control to Reduce Common-Mode Voltage Without Weighting Factors for Three-Level Inverters
The conventional model predictive control (MPC) suffers from high common-mode voltage (CMV) magnitude and large current ripples. In this paper, the reduced CMV MPC strategy with double vector (RCMV-MPCDV) is proposed for three-level inverters, which adopts double vector to reduce the CMV and current ripple simultaneously in per-sampling period. Firstly, based on geometric relationship of median, a novel cost function that evaluate median line distance is proposed to reduce the computational complexity, rather than evaluating the closest distance. Secondly, in order to reduce the computational burden, the double vector preselection (DVP) algorithm is presented with fewer evaluation times. Thirdly, the candidate vectors are reclassified and regrouped from partial basic vectors, which restricts CMV magnitude within one-sixth of DC-link voltage. In addition, to select more satisfactory double vectors for RCMV-MPCDV scheme, two improved methods are proposed to compensate the losing candidate vectors. The simulation and experimental results with steady-state performance and dynamic response validate the effectiveness of the proposed method.
- 20 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 67 (10) , 8980-8990
Double Vector Model Predictive Control to Reduce Common-Mode Voltage Without Weighting Factors for Three-Level Inverters
The conventional model predictive control (MPC) suffers from high common-mode voltage (CMV) magnitude and large current ripples. In this paper, the reduced CMV MPC strategy with double vector (RCMV-MPCDV) is proposed for three-level inverters, which adopts double vector to reduce the CMV and current ripple simultaneously in per-sampling period. Firstly, based on geometric relationship of median, a novel cost function that evaluate median line distance is proposed to reduce the computational complexity, rather than evaluating the closest distance. Secondly, in order to reduce the computational burden, the double vector preselection (DVP) algorithm is presented with fewer evaluation times. Thirdly, the candidate vectors are reclassified and regrouped from partial basic vectors, which restricts CMV magnitude within one-sixth of DC-link voltage. In addition, to select more satisfactory double vectors for RCMV-MPCDV scheme, two improved methods are proposed to compensate the losing candidate vectors. The simulation and experimental results with steady-state performance and dynamic response validate the effectiveness of the proposed method.
- 25 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 35 (7) , 7492-7505
A Fault-Tolerant Control Strategy for T-Type Three-Level Rectifier With Neutral Point Voltage Balance and Loss Reduction
This paper presents a fault-tolerant control strategy when an open-circuit fault (OCF) occurs in T-type three-level rectifiers, in which the neutral-point (NP) voltage balance and loss reduction are considered simultaneously. When an OCF occurs, one fundamental period is classified into two time intervals: the normal time interval (NTI) and abnormal time interval (ATI). In the NTI, a time-offset is utilized to achieve the NP voltage balance and loss reduction within a switching period. Aside from this, the extra switching event between the switching periods is also reduced by employing an appropriate carrier. In the ATI, the proposed method is explained by dividing fault into two conditions: the faulty condition of half-bridge (HB) switches and NP switches. When OCF occurs at HB switches, a restriction of the time-offset is introduced during the ATI. While, if an OCF occurs at NP switches, the two-level modulation strategy is applied in the faulty phase during the ATI. Besides, the principle of carrier selection of the faulty phase is changed correspondingly to avoid the extra switching event. The performance of the fault-tolerant control with respect to the NP voltage balance and loss reduction is illustrated and verified by the simulation and experimental results.
- 25 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 35 (7) , 7492-7505
A Fault-Tolerant Control Strategy for T-Type Three-Level Rectifier With Neutral Point Voltage Balance and Loss Reduction
This paper presents a fault-tolerant control strategy when an open-circuit fault (OCF) occurs in T-type three-level rectifiers, in which the neutral-point (NP) voltage balance and loss reduction are considered simultaneously. When an OCF occurs, one fundamental period is classified into two time intervals: the normal time interval (NTI) and abnormal time interval (ATI). In the NTI, a time-offset is utilized to achieve the NP voltage balance and loss reduction within a switching period. Aside from this, the extra switching event between the switching periods is also reduced by employing an appropriate carrier. In the ATI, the proposed method is explained by dividing fault into two conditions: the faulty condition of half-bridge (HB) switches and NP switches. When OCF occurs at HB switches, a restriction of the time-offset is introduced during the ATI. While, if an OCF occurs at NP switches, the two-level modulation strategy is applied in the faulty phase during the ATI. Besides, the principle of carrier selection of the faulty phase is changed correspondingly to avoid the extra switching event. The performance of the fault-tolerant control with respect to the NP voltage balance and loss reduction is illustrated and verified by the simulation and experimental results.
- 12 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 67 (8) , 6583-6596
An Optimized Zero-Sequence Voltage Injection Method for Eliminating Circulating Current and Reducing Common Mode Voltage of Parallel-Connected Three-Level Converters
Parallel three-level inverters have attracted increasing attention due to the advantages to increase the power rating and the flexibility of power conversion systems. However, this type of configuration requires to suppress the zero-sequence circulating current (ZSCC) through either modulation or active control strategies, to avoid overloading problems of a single three-level inverter. For the operation of paralleled three-level T-type inverters ( $\text{3LT}^2 \text{Is}$ ), another requirement is to reduce the common mode voltage (CMV) associated with PWM method. To better solve these problems simultaneously, an optimized zero-sequence voltage injection method is proposed to both reduce CMV and eliminate ZSCC for multi-parallel-connected three-level inverters. A generalized CMV reduction strategy is developed, which can reduce the magnitude of CMV to one-second of the value using the conventional space vector modulation (SVM). The highlight of the method is that ZSCC is eliminated by adding an optimal compensation value to the reference duty signals with lower CMV. This compensation value is calculated simply by ZSCC, duty cycles and filter parameters. The better ZSCC suppression performance can be obtained in both steady and transient states with the proposed scheme, thus, improving the quality of currents.- 12 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 67 (8) , 6583-6596
An Optimized Zero-Sequence Voltage Injection Method for Eliminating Circulating Current and Reducing Common Mode Voltage of Parallel-Connected Three-Level Converters
Parallel three-level inverters have attracted increasing attention due to the advantages to increase the power rating and the flexibility of power conversion systems. However, this type of configuration requires to suppress the zero-sequence circulating current (ZSCC) through either modulation or active control strategies, to avoid overloading problems of a single three-level inverter. For the operation of paralleled three-level T-type inverters ( $\text{3LT}^2 \text{Is}$ ), another requirement is to reduce the common mode voltage (CMV) associated with PWM method. To better solve these problems simultaneously, an optimized zero-sequence voltage injection method is proposed to both reduce CMV and eliminate ZSCC for multi-parallel-connected three-level inverters. A generalized CMV reduction strategy is developed, which can reduce the magnitude of CMV to one-second of the value using the conventional space vector modulation (SVM). The highlight of the method is that ZSCC is eliminated by adding an optimal compensation value to the reference duty signals with lower CMV. This compensation value is calculated simply by ZSCC, duty cycles and filter parameters. The better ZSCC suppression performance can be obtained in both steady and transient states with the proposed scheme, thus, improving the quality of currents.- 20 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (11) , 10988-11001
A Carrier-Based Fault-Tolerant Control Strategy for T-Type Rectifier With Neutral-Point Voltage Oscillations Suppression
This paper proposes a carrier-based fault-tolerant control strategy for T-type three-level rectifier with neutral-point (NP) voltage oscillations suppression when an open-circuit fault occurs. The proposed fault-tolerant control is demonstrated by dividing fault into two conditions: the faulty condition of outer switches and inner switches. In the case of outer switches open-circuit fault, the requirement to maintain the normal operation with sinusoidal currents is demonstrated. Meanwhile, in order to suppress the NP voltage oscillations, a hybrid NP voltage control strategy which is implemented by adding a compensation value to the reference voltage and a dc bias are used. In the case of inner switches open-circuit fault, the fundamental period of the input current is divided into two areas: normal half cycle and abnormal half cycle. In the abnormal half cycle, the reference voltage of the faulty leg is compared with a single carrier. In addition, a new compensation value is added to the reference voltage to suppress the NP voltage oscillations. While in the normal half cycle, the hybrid NP voltage control strategy and the dc bias are applied. The feasibility and performance of the proposed tolerant control are illustrated and verified through the simulation and experimental results.
- 20 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (11) , 10988-11001
A Carrier-Based Fault-Tolerant Control Strategy for T-Type Rectifier With Neutral-Point Voltage Oscillations Suppression
This paper proposes a carrier-based fault-tolerant control strategy for T-type three-level rectifier with neutral-point (NP) voltage oscillations suppression when an open-circuit fault occurs. The proposed fault-tolerant control is demonstrated by dividing fault into two conditions: the faulty condition of outer switches and inner switches. In the case of outer switches open-circuit fault, the requirement to maintain the normal operation with sinusoidal currents is demonstrated. Meanwhile, in order to suppress the NP voltage oscillations, a hybrid NP voltage control strategy which is implemented by adding a compensation value to the reference voltage and a dc bias are used. In the case of inner switches open-circuit fault, the fundamental period of the input current is divided into two areas: normal half cycle and abnormal half cycle. In the abnormal half cycle, the reference voltage of the faulty leg is compared with a single carrier. In addition, a new compensation value is added to the reference voltage to suppress the NP voltage oscillations. While in the normal half cycle, the hybrid NP voltage control strategy and the dc bias are applied. The feasibility and performance of the proposed tolerant control are illustrated and verified through the simulation and experimental results.
- 7 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (4) , 2837-2846
Fault-Tolerant Control Strategies for T-Type Three-Level Inverters Considering Neutral-Point Voltage Oscillations
Recently, a few fault-tolerant control strategies have been proposed for T-type three-level inverters to improve the reliability of the inverter system. However, the neutral-point (NP) voltage oscillations suppression is never considered in the previous fault-tolerant control strategies. In order to suppress the NP voltage oscillations when open-circuit fault occurs to NP switches, this paper proposes two novel fault-tolerant control strategies named as improved two-level switching tolerant control (I2LS-TC) and hybrid switching tolerant control (HS-TC). Both methods are implemented by adding an optimal time-offset to the three-phase turn-on times. The corresponding time-offset value of each method is simply calculated considering the phase current and dwell time of [O] state. Moreover, a NP voltage balancing algorithm to eliminate the dc deviation and a dc bias to further reduce the NP voltage oscillations are used in the HS-TC. The performance and comparison of the tolerant controls with respect to the NP voltage oscillations, current total harmonic distortion (THD) and dynamic response are illustrated and analyzed through the simulation and experimental results.
- 7 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (4) , 2837-2846
Fault-Tolerant Control Strategies for T-Type Three-Level Inverters Considering Neutral-Point Voltage Oscillations
Recently, a few fault-tolerant control strategies have been proposed for T-type three-level inverters to improve the reliability of the inverter system. However, the neutral-point (NP) voltage oscillations suppression is never considered in the previous fault-tolerant control strategies. In order to suppress the NP voltage oscillations when open-circuit fault occurs to NP switches, this paper proposes two novel fault-tolerant control strategies named as improved two-level switching tolerant control (I2LS-TC) and hybrid switching tolerant control (HS-TC). Both methods are implemented by adding an optimal time-offset to the three-phase turn-on times. The corresponding time-offset value of each method is simply calculated considering the phase current and dwell time of [O] state. Moreover, a NP voltage balancing algorithm to eliminate the dc deviation and a dc bias to further reduce the NP voltage oscillations are used in the HS-TC. The performance and comparison of the tolerant controls with respect to the NP voltage oscillations, current total harmonic distortion (THD) and dynamic response are illustrated and analyzed through the simulation and experimental results.