ABAnthony Butler

Anthony Butler

*This is an algorithmically generated author record based on publicly available information.

Anthony Butler has a total of 116 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Deep Few-View High-Resolution Photon-Counting CT at Halved Dose for Extremity Imaging

    by Mengzhou Li, Chuang Niu, Ge Wang, Maya R. Amma, Krishna M. Chapagain, Stefan Gabrielson, Andrew Li, Kevin Jonker, Niels de Ruiter, Jennifer A. Clark, et al.

    X-ray photon-counting computed tomography (PCCT) for extremity allows multi-energy high-resolution (HR) imaging but its radiation dose can be further improved. Despite the great potential of deep learning techniques, their application in HR volumetric PCCT reconstruction has been challenged by the large memory burden, training data scarcity, and domain gap issues. In this paper, we propose a deep learning-based approach for PCCT image reconstruction at halved dose and doubled speed for a New Zealand clinical trial. Specifically, we design a patch-based volumetric refinement network to alleviate the GPU memory limitation, train network with synthetic data, and use model-based iterative refinement to bridge the gap between synthetic and clinical data. Our results in a reader study of 8 patients from the clinical trial demonstrate a great potential to cut the radiation dose to half that of the clinical PCCT standard without compromising image quality and diagnostic value.


  • Open Access

    A Proof-of-Concept Solution for Co-locating 2D Histology Images in 3D for Histology-to-CT and MR Image Registration: Closing the Loop for Bone Sarcoma Treatment Planning

    by Robert Phillips, Constantine Zakkaroff, Keren Dittmer, Nicholas Robilliard, Kenzie Baer, Anthony Butler

    This work presents a proof-of-concept solution designed to facilitate more accurate radiographic feature characterisation in pre-surgical CT/MR volumes. The solution involves 3D co-location of 2D digital histology slides within ex-vivo , tumour tissue CT volumes. Initially, laboratory dissection measurements seed the placement of histology slices in corresponding CT volumes, followed by in-plane point-based registration of bone in histology images to the bone in CT. Validation using six bisected canine humerus ex-vivo CT datasets indicated a plane misalignment of 0.19 ± 1.8 mm. User input sensitivity was assessed at 0.08 ± 0.2 mm for plane translation and 0–1.6° deviation. These results show a similar magnitude of error to related prostate histology co-location work. Although demonstrated with a femoral canine sarcoma tumour, this solution can be generalised to various orthopaedic geometries and sites. It supports high-fidelity histology image co-location to improve understanding of tissue characterisation accuracy in clinical radiology. This solution requires only minimal adjustment to routine workflows. By integrating histology insights earlier in the presentation-diagnosis-planning-surgery-recovery loop, this solution guides data co-location to support the continued evaluation of safe pre-surgical margins.


  • Probability Mapping of Spectral CT Material Decomposition to Aid in Determining Material Identification and Quantification Likelihood

    by Theodorus Dapamede, Krishna M. Chapagain, Mahdieh Moghiseh, James Atlas, Philip H. Butler, Anthony P. H. Butler, MARS Collaboration

  • LHRH conjugated gold nanoparticles assisted efficient ovarian cancer targeting evaluated via spectral photon-counting CT imaging: a proof-of-concept research

    by Dhiraj Kumar, Mahdieh Moghiseh, Kenny Chitcholtan, Isha Mutreja, Chiara Lowe, Ajeet Kaushik, Anthony Butler, Peter Sykes, Nigel Anderson, Aamir Raja

    Emerging multifunctional nanoparticulate formulations take advantage of nano-meter scale size and surface chemistry to work as a therapeutic delivery agent and a diagnostic tool for non-invasive real-time monitoring using imaging technologies. Here, we evaluate the selective uptake of 18 nm and 80 nm sized gold nanoparticles (AuNPs) by SKOV3 (4 times higher) ovarian cancer (OC) cells (compared to OVCAR5) in vitro, quantified by inductively coupled plasma (ICP) and MARS spectral photon-counting CT imaging (MARS SPCCT). Based on in vitro analysis, pristine AuNPs (18 nm) and surface modified AuNPs (18 nm) were chosen as a contrast agent for MARS SPCCT. The chemical analysis by FTIR spectroscopy confirmed the luteinizing hormone-releasing hormone (LHRH) conjugation to the AuNPs surface. For the first time, LHRH conjugated AuNPs were used for in vitro and selective in vivo OC targeting. The ICP-MS analysis confirmed preferential uptake of LHRH modified AuNPs by organs residing in the abdominal cavity with OC nodules (pancreas: 0.46 ng mg−1, mesentery: 0.89 ng mg−1, ovary: 1.43 ng mg−1, and abdominal wall: 2.12 ng mg−1) whereas the MARS SPCCT analysis suggested scattered accumulation of metal around the abdominal cavity. Therefore, the study showed the exciting potential of LHRH conjugated AuNPs to target ovarian cancer and also as a potential contrast agent for novel SPCCT imaging technology.


  • Open Access

    Spectral Photon-Counting CT Imaging of Gold Nanoparticle Labelled Monocytes for Detection of Atherosclerosis: A Preclinical Study

    by Mahdieh Moghiseh, Emily Searle, Devyani Dixit, Johoon Kim, Yuxi C. Dong, David P. Cormode, Anthony Butler, Steven P. Gieseg, Mars Bioimaging Ltd.

    A key process in the development of atherosclerotic plaques is the recruitment of monocytes into the artery wall. Using spectral photon-counting computed tomography we examine whether monocyte deposition within the artery wall of ApoE-/- mouse can be detected. Primary mouse monocytes were labelled by incubating them with 15 nm gold nanoparticles coated with 11-mercaptoundecanoic acid The monocyte uptake of the particle was confirmed by electron microscopy of the cells before injection into 6-week-old apolipoprotein E deficient (ApoE-/-) mouse that had been fed with the Western diet for 10 weeks. Four days following injection, the mouse was sacrificed and imaged using a MARS spectral photon counting computed tomography scanner with a spectral range of 7 to 120 KeV with five energy bins. Imaging analysis showed the presence of X-ray dense material within the mouse aortic arch which was consistent with the spectral characteristic of gold rather than calcium. The imaging is interpreted as showing the deposition of gold nanoparticles containing monocytes within the mouse aorta. The results of our study determined that spectral photon-counting computed tomography could provide quantitative information about gold nanoparticles labelled monocytes in voxels of 90 × 90 × 90 µm3. The imaging was consistent with previous micro-CT and electron microscopy of mice using the same nanoparticles. This study demonstrates that spectral photon-counting computed tomography, using a MARS small bore scanner, can detect a fundamental atherogenic process within mouse models of atherogenesis. The present study demonstrates the feasibility of spectral photon-counting computed tomography as an emerging molecular imaging modality to detect atherosclerotic disease.


  • Hitchhiking probiotic vectors to deliver ultra-small hafnia nanoparticles for ‘Color’ gastrointestinal tract photon counting X-ray imaging

    by Fatemeh Ostadhossein, Parikshit Moitra, Nivetha Gunaseelan, Michael Nelappana, Chiara Lowe, Mahdieh Moghiseh, Anthony Butler, Niels de Ruiter, Harish Mandalika, Indu Tripathi, et al.

    Gastrointestinal (GI) tract is one of the hard-to-reach target tissues for the delivery of contrast agents and drugs mediated by nanoparticles due to its harsh environment. Herein, we overcame this barrier by designing orally ingestible probiotic vectors for ‘hitchhiking’ ultrasmall hafnia (HfO2) (∼1–2 nm) nanoparticles. The minute-made synthesis of these nanoparticles is accomplished through a simple reduction reaction. These nanoparticles were incubated with probiotic bacteria with potential health benefits and were non-specifically taken up due to their small size. Subsequently, the bacteria were lyophilized and packed into a capsule to be administered orally as the radiopaque contrast agents for delineating the GI features. These nano-bio-hybrid entities could successfully be utilized as contrast agents in vivo in the conventional and multispectral computed tomography (CT). We demonstrated in ‘color’ the accumulated nanoparticles using advanced detectors of the photon counting CT. The enhanced nano-bio-interfacing capability achieved here can circumvent traditional nanoparticle solubility and delivery problems while offering a patient friendly approach for GI imaging to replace the currently practiced barium meal.


  • Open Access

    Spectral CT imaging of human osteoarthritic cartilage via quantitative assessment of glycosaminoglycan content using multiple contrast agents

    by Kenzie Baer, Sandra Kieser, Ben Schon, Kishore Rajendran, Timen Ten Harkel, Mohsen Ramyar, Caroline Löbker, Christopher Bateman, Anthony Butler, Aamir Raja, et al.

    Detection of early osteoarthritis to stabilize or reverse the damage to articular cartilage would improve patient function, reduce disability, and limit the need for joint replacement. In this study, we investigated nondestructive photon-processing spectral computed tomography (CT) for the quantitative measurement of the glycosaminoglycan (GAG) content compared to destructive histological and biochemical assay techniques in normal and osteoarthritic tissues. Cartilage-bone cores from healthy bovine stifles were incubated in 50% ioxaglate (Hexabrix®) or 100% gadobenate dimeglumine (MultiHance®). A photon-processing spectral CT (MARS) scanner with a CdTe-Medipix3RX detector imaged samples. Calibration phantoms of ioxaglate and gadobenate dimeglumine were used to determine iodine and gadolinium concentrations from photon-processing spectral CT images to correlate with the GAG content measured using a dimethylmethylene blue assay. The zonal distribution of GAG was compared between photon-processing spectral CT images and histological sections. Furthermore, discrimination and quantification of GAG in osteoarthritic human tibial plateau tissue using the same contrast agents were demonstrated. Contrast agent concentrations were inversely related to the GAG content. The GAG concentration increased from 25 μg/ml (85 mg/ml iodine or 43 mg/ml gadolinium) in the superficial layer to 75 μg/ml (65 mg/ml iodine or 37 mg/ml gadolinium) in the deep layer of healthy bovine cartilage. Deep zone articular cartilage could be distinguished from subchondral bone by utilizing the material decomposition technique. Photon-processing spectral CT images correlated with histological sections in healthy and osteoarthritic tissues. Post-imaging material decomposition was able to quantify the GAG content and distribution throughout healthy and osteoarthritic cartilage using Hexabrix® and MultiHance® while differentiating the underlying subchondral bone.


  • Interactive Image Segmentation of MARS Datasets Using Bag of Features

    by Praveenkumar Kanithi, Niels J. A. de Ruiter, Maya R. Amma, Robert W. Lindeman, Anthony P. H. Butler, Philip H. Butler, Alexander I. Chernoglazov, V. B. H. Mandalika, Sikiru A. Adebileje, Steven D. Alexander, et al.

    In this article, we propose a slice-based interactive segmentation of spectral CT datasets using a bag of features method. The data are acquired from a MARS scanner that divides up the X-ray spectrum into multiple energy bins for imaging. In literature, most existing segmentation methods are limited to performing a specific task or tied to a particular imaging modality. Therefore, when applying generalized methods to MARS datasets, the additional energy information acquired from the scanner cannot be sufficiently utilized. We describe a new approach that circumvents this problem by effectively aggregating the data from multiple channels. Our method solves a classification problem to get the solution for segmentation. Starting with a set of labeled pixels, we partition the data using superpixels. Then, a set of local descriptors, extracted from each superpixel, are encoded into a codebook and pooled together to create a global superpixel-level descriptor (bag of features representation). We propose to use the vector of locally aggregated descriptors as our encoding/pooling strategy, as it is efficient to compute and leads to good results with simple linear classifiers. A linear support vector machine is then used to classify the superpixels into different labels. The proposed method was evaluated on multiple MARS datasets. Experimental results show that our method achieved an average of more than 10% increase in the accuracy over other state-of-the-art methods.

  • Open Access

    Ultrasmall hafnium oxide nanoparticles for the detection of bone microdamage using color spectral CT

    by Anthony Butler, Indu Tripathi, Lily Benig, Mahdieh Moghiseh, Chiara Lowe, Dipanjan Pan, Ostadhossein Fatemeh

  • Assessment of Material Identification Errors, Image Quality, and Radiation Doses Using Small Animal Spectral Photon-Counting CT

    by Emmanuel Marfo, Nigel G. Anderson, Anthony P. H. Butler, Nanette Schleich, Pierre Carbonez, Jérôme Damet, Chiara Lowe, Joe Healy, Alexander I. Chernoglazov, Mahdieh Moghiseh, et al.

    Photon-counting CT offers the potential to provide new diagnostic information. In this study, we sought to determine the interplay between material identification errors, image quality indicators, and radiation doses using photon-counting spectral CT, and to determine whether this relationship is replicated in spectral CT scans of mice. Custom-built Perspex phantoms were used to measure signal-to-noise ratio and spatial resolution, and to measure radiation dose using thermoluminescent dosimeters. A multi-contrast calibration phantom containing inserts with different concentrations of gadolinium (1, 2, 4 and 8 mg/mL), hydroxyapatite rods (0, 54.3, 104.3, 211.7, 402.3 and 808.5 mg/mL) along with water and lipid was used to assess material identification errors. Image acquisition was performed using the MARS photon-counting scanner with four energy channels (30-45, 45-60, 60-78 and 78-118 keV) at four different tube currents (24, 34, 44 and 55 mA). As increased tube current showed no significant effect on material characterisation, small animal dosimetry was performed with 24 mA tube current using two non-contrast mice and one mouse injected with gadolinium. Results demonstrated that a tube current increase from 24 to 54 mA improved the signal-to-noise ratio and spatial resolution by <10%, gadolinium identification by 160%. Imaging results of the mice showed no obvious artefacts, and the mean absorbed dose measured for the three mice was 27.3±2.4 mGy. The results suggest that the energy resolving capability of photon-counting CT maintains diagnostically relevant image quality with high levels of material discrimination at reduced radiation dose.