Johannes Dickmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Johannes Dickmann has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
Stefanie Kroker
Technical University of Braunschweig, Institute for Semiconductor Technology, Braunschweig, Germany
16 shared publicationsMika Gaedtke
Institute for Semiconductor Technology, Technical University of Braunschweig, Brunswick, Germany
8 shared publications- Stefanie Kroker
TU Braunschweig, Institute of Semiconductor Technology
8 shared publications - Sebastian Ulbricht
Fundamentale Physik für Metrologie FPM, Physikalisch-Technische Bundesanstalt PTB, Braunschweig, Germany
6 shared publications Jan Meyer
Institute for Semiconductor Technology, Technical University of Braunschweig, Brunswick, Germany
5 shared publicationsSteffen Sauer
CAVITY technologies UG (haftungsbeschränkt), Braunschweig, Germany
5 shared publications
Latest Publications
- Open Access
- 1 June 2025
- Published by AIP Publishing in APL Materials
- Vol. 13 (6)
Temperature-dependent mechanical losses of Eu3+:Y2SiO5 for spectral hole burning laser stabilization
We investigate the mechanical loss characteristics of Eu3+:Y2SiO5—a promising candidate for ultra-low-noise frequency stabilization through the spectral hole burning technique. Three different mechanical oscillators with varying surface-to-volume ratios and crystal orientations are evaluated. In this context, we perform mechanical ringdown and spectral measurements spanning temperatures from room temperature down to 15 K. By doing so, we measure a maximum mechanical quality factor of Q = 3676, corresponding to a loss angle of ϕ = 2.72 × 10−4. For a spectral hole burning laser stabilization experiment at 300 mK, we can estimate the Allan deviation of the fractional frequency instability due to Brownian thermal noise to be below σδν/ν0=2.4×10−18, a value lower than the estimated thermal-noise limit of any current cavity-referenced ultra-stable laser experiment.
- 1 June 2025
- Published by AIP Publishing in APL Materials
- Vol. 13 (6)
Open AccessTemperature-dependent mechanical losses of Eu3+:Y2SiO5 for spectral hole burning laser stabilization
We investigate the mechanical loss characteristics of Eu3+:Y2SiO5—a promising candidate for ultra-low-noise frequency stabilization through the spectral hole burning technique. Three different mechanical oscillators with varying surface-to-volume ratios and crystal orientations are evaluated. In this context, we perform mechanical ringdown and spectral measurements spanning temperatures from room temperature down to 15 K. By doing so, we measure a maximum mechanical quality factor of Q = 3676, corresponding to a loss angle of ϕ = 2.72 × 10−4. For a spectral hole burning laser stabilization experiment at 300 mK, we can estimate the Allan deviation of the fractional frequency instability due to Brownian thermal noise to be below σδν/ν0=2.4×10−18, a value lower than the estimated thermal-noise limit of any current cavity-referenced ultra-stable laser experiment.
- Open Access
- 25 January 2024
- Published by Springer Nature in Communications Engineering
- Vol. 3 (1) , 1-8
Moderate-coherence sensing with optical cavities: ultra-high accuracy meets ultra-high measurement bandwidth and range
Interferometric sensors, renowned for their exceptional accuracy, leverage the wave properties of coherent electromagnetic radiation. The periodicity of the measurement signal often critically limits the measurement range of sensors utilizing interferometry. Here we introduce a cavity-based interferometry concept that capitalizes on a laser with moderate coherence, thereby combining ultra-high accuracy with ultra-high measurement bandwidth and range. To this end mid-fringe detection is combined with measurements of the interferometric visibility. We present experimental results that demonstrate the effectiveness of our approach exemplarily for length sensing. Notably, our system achieves an accuracy of 1 nm with a measurement range of 120 μm (relative uncertainty of 0.00083 %) and a bandwidth ranging from 0 Hz to 20 kHz. These findings support advancements in high-precision sensing applications that demand simultaneous accuracy, measurement range and bandwidth.
- 25 January 2024
- Published by Springer Nature in Communications Engineering
- Vol. 3 (1) , 1-8
Open AccessModerate-coherence sensing with optical cavities: ultra-high accuracy meets ultra-high measurement bandwidth and range
Interferometric sensors, renowned for their exceptional accuracy, leverage the wave properties of coherent electromagnetic radiation. The periodicity of the measurement signal often critically limits the measurement range of sensors utilizing interferometry. Here we introduce a cavity-based interferometry concept that capitalizes on a laser with moderate coherence, thereby combining ultra-high accuracy with ultra-high measurement bandwidth and range. To this end mid-fringe detection is combined with measurements of the interferometric visibility. We present experimental results that demonstrate the effectiveness of our approach exemplarily for length sensing. Notably, our system achieves an accuracy of 1 nm with a measurement range of 120 μm (relative uncertainty of 0.00083 %) and a bandwidth ranging from 0 Hz to 20 kHz. These findings support advancements in high-precision sensing applications that demand simultaneous accuracy, measurement range and bandwidth.
- 18 January 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 109 (2) , 022005
Using gravitational light deflection in optical cavities for laser frequency stabilization
We theoretically investigate the propagation of light in the presence of a homogeneous gravitational field. To model this, we derive the solutions of the wave equation in Rindler spacetime, which account for gravitational redshift and light deflection. The developed theoretical framework is used to explore the propagation of plane light waves in a horizontal Fabry-Pérot cavity. We pay particular attention to the cavity output power. It is shown that this power depends not only on the input frequency but also on the vertical position of a detector. We state that the height-dependent detector signal arising from the cavity internal light deflection effect also opens a new alternative way to frequency stabilization in Earth-based laser experiments and to study gravitational light deflection at laboratory scales.
- 18 January 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 109 (2) , 022005
Using gravitational light deflection in optical cavities for laser frequency stabilization
We theoretically investigate the propagation of light in the presence of a homogeneous gravitational field. To model this, we derive the solutions of the wave equation in Rindler spacetime, which account for gravitational redshift and light deflection. The developed theoretical framework is used to explore the propagation of plane light waves in a horizontal Fabry-Pérot cavity. We pay particular attention to the cavity output power. It is shown that this power depends not only on the input frequency but also on the vertical position of a detector. We state that the height-dependent detector signal arising from the cavity internal light deflection effect also opens a new alternative way to frequency stabilization in Earth-based laser experiments and to study gravitational light deflection at laboratory scales.
- 2 December 2023
- Published by Allerton Press in Kinematics and Physics of Celestial Bodies
- Vol. 39 (6) , 356-359
Modification of Inertia Resulting from a Hubble-Scale Casimir Effect Contradicts Classical Inertia
Inertia is one of the most vivid and at the same time puzzling physical properties of bodies. As an equivalence between inertial and gravitational mass in
- 2 December 2023
- Published by Allerton Press in Kinematics and Physics of Celestial Bodies
- Vol. 39 (6) , 356-359
Modification of Inertia Resulting from a Hubble-Scale Casimir Effect Contradicts Classical Inertia
Inertia is one of the most vivid and at the same time puzzling physical properties of bodies. As an equivalence between inertial and gravitational mass in
- Open Access
- 9 November 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-6
Temperature-dependent photo-elastic coefficient of silicon at 1550 nm
This paper presents a study on the temperature dependent photo-elastic coefficient in single-crystal silicon with (100) and (110) orientations at a wavelength of 1550 nm. The measurement of the photo-elastic coefficient was performed using a polarimetric scheme across a wide temperature range from 5 to 300 K. The experimental setup employed high-sensitivity techniques and incorporated automatic beam path correction, ensuring precise and accurate determination of the coefficient’s values. The results show excellent agreement with previous measurements at room temperature, specifically yielding a value of $$dn/d\sigma = -2.463 \times 10^{-11}$$ 1/Pa for the (100) orientation. Interestingly, there is a significant difference in photo-elasticity between the different crystal orientations of approximately $$50\%$$ . The photo-elastic coefficient’s absolute value increases by approximately 40% with decreasing temperature down to 5 K. These findings provide valuable insights into the photo-elastic properties of silicon and its behavior under varying mechanical stress, particularly relevant for optomechanical precision experiments like cryogenic gravitational wave detectors and microscale optomechanical quantum sensors.- 9 November 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-6
Open AccessTemperature-dependent photo-elastic coefficient of silicon at 1550 nm
This paper presents a study on the temperature dependent photo-elastic coefficient in single-crystal silicon with (100) and (110) orientations at a wavelength of 1550 nm. The measurement of the photo-elastic coefficient was performed using a polarimetric scheme across a wide temperature range from 5 to 300 K. The experimental setup employed high-sensitivity techniques and incorporated automatic beam path correction, ensuring precise and accurate determination of the coefficient’s values. The results show excellent agreement with previous measurements at room temperature, specifically yielding a value of $$dn/d\sigma = -2.463 \times 10^{-11}$$ 1/Pa for the (100) orientation. Interestingly, there is a significant difference in photo-elasticity between the different crystal orientations of approximately $$50\%$$ . The photo-elastic coefficient’s absolute value increases by approximately 40% with decreasing temperature down to 5 K. These findings provide valuable insights into the photo-elastic properties of silicon and its behavior under varying mechanical stress, particularly relevant for optomechanical precision experiments like cryogenic gravitational wave detectors and microscale optomechanical quantum sensors. - Open Access
- 18 October 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 287, 04019
Ultra-low noise meta-mirrors with optical losses below 500 ppm
Interferometric experiments are often limited in sensitivity by the thermal noise of the mirrors. In particular, interferometric gravitational wave detectors and laser stabilization resonators can benefit from reduced mirror noise. We present results of experimental investigations on micro-structured mirrors (meta-mirrors) and hybrid etalon mirrors (meta-etalons) promising particularly low thermal noise. We show the first characterization of meta-etalons scattering and absorption losses, demonstrating optical losses below 500 ppm. This level of optical losses is sufficient for planning direct thermal noise measurement in dedicated optical cavity experiments. These measurements would be very important for validating the thermal noise predictions. We present our development toward the integration of meta-etalons in ultra-stable optical cavities.
- 18 October 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 287, 04019
Open AccessUltra-low noise meta-mirrors with optical losses below 500 ppm
Interferometric experiments are often limited in sensitivity by the thermal noise of the mirrors. In particular, interferometric gravitational wave detectors and laser stabilization resonators can benefit from reduced mirror noise. We present results of experimental investigations on micro-structured mirrors (meta-mirrors) and hybrid etalon mirrors (meta-etalons) promising particularly low thermal noise. We show the first characterization of meta-etalons scattering and absorption losses, demonstrating optical losses below 500 ppm. This level of optical losses is sufficient for planning direct thermal noise measurement in dedicated optical cavity experiments. These measurements would be very important for validating the thermal noise predictions. We present our development toward the integration of meta-etalons in ultra-stable optical cavities.
- Open Access
- 4 October 2023
- Published by Springer Nature in Research Square
Temperature-dependent Photo-Elastic Coefficient of Silicon at 1550 nm
This paper presents a study on the temperature dependent photo-elastic coefficient in single-crystal silicon with (100) and (110) orientations at a wavelength of 1550 nm. The measurement of the photo-elastic coefficient was performed using a polarimetric scheme across a wide temperature range from 5 K to 300 K. The experimental setup employed high-sensitivity techniques and incorporated automatic beam path correction, ensuring precise and accurate determination of the coefficient’s values. The results show excellent agreement with previous measurements at room temperature, specifically yielding a value of dn/dσ = −2.463 × 10-11 1/Pa for the (100) orientation. Interestingly, there is a significant difference in photo-elasticity between the different crystal orientations of approximately 50 %. The photo-elastic coefficient’s absolute value increases by approximately 40 % with decreasing temperature down to 5 K. These findings provide valuable insights into the photo-elastic properties of silicon and its behavior under varying mechanical stress, particularly relevant for optomechanical precision experiments like cryogenic gravitational wave detectors and microscale optomechanical quantum sensors.
- 4 October 2023
- Published by Springer Nature in Research Square
Open AccessTemperature-dependent Photo-Elastic Coefficient of Silicon at 1550 nm
This paper presents a study on the temperature dependent photo-elastic coefficient in single-crystal silicon with (100) and (110) orientations at a wavelength of 1550 nm. The measurement of the photo-elastic coefficient was performed using a polarimetric scheme across a wide temperature range from 5 K to 300 K. The experimental setup employed high-sensitivity techniques and incorporated automatic beam path correction, ensuring precise and accurate determination of the coefficient’s values. The results show excellent agreement with previous measurements at room temperature, specifically yielding a value of dn/dσ = −2.463 × 10-11 1/Pa for the (100) orientation. Interestingly, there is a significant difference in photo-elasticity between the different crystal orientations of approximately 50 %. The photo-elastic coefficient’s absolute value increases by approximately 40 % with decreasing temperature down to 5 K. These findings provide valuable insights into the photo-elastic properties of silicon and its behavior under varying mechanical stress, particularly relevant for optomechanical precision experiments like cryogenic gravitational wave detectors and microscale optomechanical quantum sensors.
- Open Access
- 20 September 2023
- Published by Springer Nature in Research Square
Moderate-coherence sensing with optical cavities: ultra-high accuracy meets ultra-high measurement bandwidth and range
Interferometric sensors, renowned for their exceptional accuracy, leverage the wave properties of coherent electromagnetic radiation. The periodicity of the measurement signal often critically limits the measurement range of sensors utilizing interferometry. This contribution introduces a cavity-based interferometry concept that capitalizes on a laser with moderate coherence, thereby combining ultra-high accuracy with ultra-high measurement bandwidth and range. To this end mid-fringe detection is combined with measurements of the interferometric visibility. We present experimental results that demonstrate the effectiveness of our approach exemplarily for length sensing. Notably, our system achieves an accuracy of 1 nm with a measurement range of 120 μm (0.00083%) and a bandwidth ranging from 0 Hz to 20 kHz. These findings pave the way for advancements in high-precision sensing applications that demand simultaneous accuracy, measurement range and bandwidth.
- 20 September 2023
- Published by Springer Nature in Research Square
Open AccessModerate-coherence sensing with optical cavities: ultra-high accuracy meets ultra-high measurement bandwidth and range
Interferometric sensors, renowned for their exceptional accuracy, leverage the wave properties of coherent electromagnetic radiation. The periodicity of the measurement signal often critically limits the measurement range of sensors utilizing interferometry. This contribution introduces a cavity-based interferometry concept that capitalizes on a laser with moderate coherence, thereby combining ultra-high accuracy with ultra-high measurement bandwidth and range. To this end mid-fringe detection is combined with measurements of the interferometric visibility. We present experimental results that demonstrate the effectiveness of our approach exemplarily for length sensing. Notably, our system achieves an accuracy of 1 nm with a measurement range of 120 μm (0.00083%) and a bandwidth ranging from 0 Hz to 20 kHz. These findings pave the way for advancements in high-precision sensing applications that demand simultaneous accuracy, measurement range and bandwidth.
- 27 April 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (10) , 15953-15965
Levitating the noise performance of ultra-stable laser cavities assisted by a deep neural network: the non-intuitive role of the mirrors
The most precise measurand available to science is the frequency of ultra-stable lasers. With a relative deviation of 4 × 10−17 over a wide range of measuring times between one second and 100 seconds, the smallest effects in nature can thus be made measurable. To enable cutting-edge precision, the laser frequency is stabilized to an external optical cavity. This complex optical device must be manufactured to the highest standards and shielded from environmental influences. Given this assumption, the smallest internal sources of perturbation become dominant, namely the internal noise of the optical components. In this work, we present the optimization of all relevant noise sources from all components of the frequency-stabilized laser. We discuss the correlation between each individual noise source and the different parameters of the system and discover the significance of the mirrors. The optimized laser offers a design stability of 8 × 10−18 for an operation at room temperature for measuring times between one second and 100 seconds.
- 27 April 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (10) , 15953-15965
Levitating the noise performance of ultra-stable laser cavities assisted by a deep neural network: the non-intuitive role of the mirrors
The most precise measurand available to science is the frequency of ultra-stable lasers. With a relative deviation of 4 × 10−17 over a wide range of measuring times between one second and 100 seconds, the smallest effects in nature can thus be made measurable. To enable cutting-edge precision, the laser frequency is stabilized to an external optical cavity. This complex optical device must be manufactured to the highest standards and shielded from environmental influences. Given this assumption, the smallest internal sources of perturbation become dominant, namely the internal noise of the optical components. In this work, we present the optimization of all relevant noise sources from all components of the frequency-stabilized laser. We discuss the correlation between each individual noise source and the different parameters of the system and discover the significance of the mirrors. The optimized laser offers a design stability of 8 × 10−18 for an operation at room temperature for measuring times between one second and 100 seconds.
- Open Access
Using gravitational light deflection in optical cavities for laser frequency stabilization
We theoretically investigate the propagation of light in the presence of a homogeneous gravitational field. To model this, we derive the solutions of the wave equation in Rindler spacetime, which account for gravitational redshift and light deflection. The developed theoretical framework is used to explore the propagation of plane light waves in a horizontal Fabry-Perot cavity. We pay particular attention to the cavity output power. It is shown that this power depends not only on the input frequency, but also on the vertical position of a detector. We state that the height-dependent detector signal arising from the cavity internal light deflection effect (CILD-effect) also opens a new alternative way to frequency stabilization in Earth-based laser experiments and to study gravitational light deflection at laboratory scales.
Open AccessUsing gravitational light deflection in optical cavities for laser frequency stabilization
We theoretically investigate the propagation of light in the presence of a homogeneous gravitational field. To model this, we derive the solutions of the wave equation in Rindler spacetime, which account for gravitational redshift and light deflection. The developed theoretical framework is used to explore the propagation of plane light waves in a horizontal Fabry-Perot cavity. We pay particular attention to the cavity output power. It is shown that this power depends not only on the input frequency, but also on the vertical position of a detector. We state that the height-dependent detector signal arising from the cavity internal light deflection effect (CILD-effect) also opens a new alternative way to frequency stabilization in Earth-based laser experiments and to study gravitational light deflection at laboratory scales.