SKStefanie Kroker

Stefanie Kroker

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stefanie Kroker has a total of 414 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Benchmarking dual-polarization silicon nitride photonic integrated circuits for trapped-ion quantum technologies

    by Carl-Frederik Grimpe, Anastasiia Lüßmann-Sorokina, Guochun Du, Pragya Sah, Steffen Sauer, Elena Jordan, Rijil Thomas, Pascal Gehrmann, Maksim Lipkin, Stephan Suckow, et al.

    Trapped ions are one of the most advanced platforms for quantum technologies, with applications ranging from quantum computing to precision timekeeping. A crucial step towards more compact and scalable systems involves integrating photonic integrated circuits (PICs) into surface ion traps to enable on-chip light delivery and optical addressing of individual ions. Currently, most implementations rely solely on transverse-electric (TE) mode grating couplers, where the emitted light is polarized in the plane of the chip. In this work, we design, fabricate and characterize key silicon nitride (Si 3 N 4 ) PIC components required for scaling trapped-ion based quantum systems to multiple operating zones, including incoupling structures, splitters, and grating couplers that support both TE and transverse-magnetic (TM) modes with comparable optical losses. We benchmark the PIC at 760 nm, which is a typical wavelength for Yb + -applications. The fabricated grating couplers enable the outcoupling of collimated free-space beams for both polarizations, exhibiting distinct emission angles. This dual-polarization capability gives more flexibility in polarization control and expands the accessible optical design space for trapped-ion quantum technologies.


  • Open Access

    Atomic layer deposition for hafnium oxide-based meta-optics in the ultraviolet spectral range

    by Thomas Siefke, Kristin Gerold, Svetlana Shestaeva, Pallabi Paul, Shawon Alam, Daniel Franta, Adriana Szeghalmi, Sven Schröder, Stefanie Kroker

    Hafnium oxide (HfO 2 ) is a high-index dielectric material of growing importance for optical coatings and meta-optical components operating from the ultraviolet (UV) to the visible spectral range. Its large bandgap, chemical stability, and compatibility with established semiconductor processes make it particularly attractive for applications requiring low absorption and precise thickness control. In this work, we investigate the optical material properties of HfO 2 thin films deposited by plasma-enhanced atomic layer deposition (PEALD). The complex refractive index is experimentally determined over a broad spectral range extending from the vacuum ultraviolet (140 nm) to the visible (600 nm) by combining spectroscopic ellipsometry, spectrophotometry, and infrared ellipsometry. A comprehensive dispersion model is employed to extract consistent optical constants and thickness values. The results highlight the suitability of PEALD-grown HfO 2 films for advanced optical and meta-optical applications.


  • Thermal-noise limits to the frequency stability of burned spectral holes

    by M. T. Hartman, N. Wagner, S. Kroker, S. Seidelin, B. Fang

    Techniques in frequency stabilization of lasers to fixed-spacer optical cavities have advanced to the point where the ultimate frequency stabilities are limited by thermal noise for standard cavity configurations at room temperature. In early experiments, laser stabilization via spectral-hole burning (SHB) has been shown to be a promising alternative. In this Letter, we explore the thermal-noise limits to frequency stability in spectral holes and compile known material parameters for a typical system used in SHB experiments (Eu3+ doped Y2SiO5) to make numerical estimates for the fundamental thermal-noise induced frequency instability in spectral holes for the liquid-helium temperature and dilution temperature cases. These efforts can guide the design of future SHB experiments and clarify which important material parameters remain to be measured.


  • Open Access

    Temperature-dependent mechanical losses of Eu3+:Y2SiO5 for spectral hole burning laser stabilization

    by Nico Wagner, Michael T. Hartman, Bess Fang, Johannes Dickmann, Stefanie Kroker

    We investigate the mechanical loss characteristics of Eu3+:Y2SiO5—a promising candidate for ultra-low-noise frequency stabilization through the spectral hole burning technique. Three different mechanical oscillators with varying surface-to-volume ratios and crystal orientations are evaluated. In this context, we perform mechanical ringdown and spectral measurements spanning temperatures from room temperature down to 15 K. By doing so, we measure a maximum mechanical quality factor of Q = 3676, corresponding to a loss angle of ϕ = 2.72 × 10−4. For a spectral hole burning laser stabilization experiment at 300 mK, we can estimate the Allan deviation of the fractional frequency instability due to Brownian thermal noise to be below σδν/ν0=2.4×10−18, a value lower than the estimated thermal-noise limit of any current cavity-referenced ultra-stable laser experiment.


  • Open Access

    Resolution enhancement methods in optical microscopy for dimensional optical metrology

    by Mohammad Nouri, Paolo Olivero, Stefanie Kroker, Tim Kaeseberg, Ivano Ruo-Berchera, Bernd Bodermann, Himanshu Tyagi, Deb Roy, Deshabrato Mukherjee, Thomas Siefke, et al.

    In this paper, we discuss several enhancement approaches to increase the resolution and sensitivity of optical microscopy as a tool for dimensional nanometrology. Firstly, we discuss a newly developed through-focus microscopy technique providing additional phase information from the afocal images to increase the nanoscale sensitivity of classical microscopy. We also explore different routes to label-free or semiconductor compatible labelling super-resolution microscopy suitable for a broad range of technical applications. We present initial results from, a new wide-field super-resolution imaging technique enabled by Raman scattering. In addition, we discuss super-resolution imaging using NV centres in nano-diamonds as labels and their application in future reference standards.


  • Open Access

    Process development and validation of next generation 3D calibration standards for application in optical microscopy

    by Celina Hellmich, Lena Heinrich, Matthias Hemmleb, Sebastian Bütefisch, Thomas Weimann, Stefanie Kroker

    A scalable wafer-based fabrication process for a new generation of 3D standards enabling the 3D calibration of optical microscopes is presented and validated. The 3D standards are based on step pyramids with several layers in the µm range and a system of cylindrical knops distributed across the layers as marks for coordinate based calibration. This enables calibration for the three coordinate axes and the orthogonality error between them in a single measurement step. The requirements necessary for such a calibration, as optical non-transparency, reproducible flatness of the pyramid step heights and the lowest possible deviations of the lateral marks coordinates, are met by optimizing the manufacturing process: The deviation of the height steps distributed over the wafer is ±3.6 nm and is primarily caused by the layer deposition processes. The lateral manufacturing accuracy was determined using calibrated scanning electron microscope (SEM) and show a mean deviation of 20 or 60 nm, depending on the lateral size of the structures. The electron beam lithography process and the level of inaccuracy of the SEM standard have an influence on the lateral scaling accuracy. Based on the tactilely generated height values and the coordinates of the mark determined by a calibrated SEM, an example calibration of a confocal laser scanning microscope was successfully performed and showed good conformity to conventional calibration techniques.


  • Open Access

    Photonic and Optomechanical Thermometry

    by Tristan Briant, Stephan Krenek, Andrea Cupertino, Ferhat Loubar, Rémy Braive, Lukas Weituschat, Daniel Ramos, Maria Jose Martin, Pablo A. Postigo, Alberto Casas, et al.

    Temperature is one of the most relevant physical quantities that affects almost all processes in nature. However, the realization of accurate temperature standards using current temperature references, like the triple point of water, is difficult due to the requirements on material purity and stability of the environment. In addition, in harsh environments, current temperature sensors with electrical readout, like platinum resistors, are difficult to implement, urging the development of optical temperature sensors. In 2018, the European consortium Photoquant, consisting of metrological institutes and academic partners, started investigating new temperature standards for self-calibrated, embedded optomechanical sensor applications, as well as optimised high resolution and high reliability photonic sensors, to measure temperature at the nano and meso-scales and as a possible replacement for the standard platinum resistant thermometers. This article presents an overview of the results obtained with sensor prototypes that exploit photonic and optomechanical techniques for sensing temperatures over a large temperature range (5 K to 300 K). Different concepts are demonstrated, including ring resonators, ladder-like resonators and suspended membrane optomechanical thermometers, highlighting initial performance and challenges, like self-heating that need to be overcome to realize photonic and optomechanical thermometry applications.


  • Open Access

    Two-Color Grating Magneto-Optical Trap for Narrow-Line Laser Cooling

    by S. Bondza, C. Lisdat, S. Kroker, T. Leopold

    We demonstrate the two-color cooling and trapping of alkaline-earth atoms in a grating magneto-optical trap (GMOT). The trap is formed by a single incident laser beam together with four secondary beams that are generated via diffraction from a nanostructured wafer. A grating structure for a GMOT operating with strontium atoms is optimized and fabricated. We trap 10688Sr atoms on the 1S0→1P1 transition at 461nm and transfer 25% of these atoms to the second cooling stage on the narrower 1S0→3P1 intercombination transition at 689nm, preparing a sample of 2.5×105 atoms at 5μK. These results demonstrate the applicability of the GMOT technology in conjunction with two widely differing wavelengths and enable the continued miniaturization of alkaline-earth-based quantum technologies like optical atomic clocks.


  • Impact of Earth’s gravity on Gaussian beam propagation in hemispherical cavities

    by S. Ulbricht, J. Dickmann, R. A. Müller, S. Kroker, A. Surzhykov

    We theoretically investigate the influence of gravity on laser light in a plano concave, i.e., hemispherical optical cavity, operating on Earth. The propagation of light in such a cavity is modeled by a Gaussian beam, affected by the Earth’s gravitational field. On laboratory scale, this field is described by the spacetime of homogeneous gravity, known as Rindler spacetime. In that spacetime, the beam is bent downwards and acquires a height dependent phase shift. As a consequence the phase fronts of the laser light differ from those of a usual Gaussian beam. Assuming that the initial beam enters the cavity along its symmetry axis, these gravitational effects cause variations of the beam phase with every cavity round trip. Detailed calculations are performed to investigate how these phase variations depend on the beam parameters and the cavity setup. Moreover, we discuss the implications of our findings for cavity calibration techniques and cavity-based laser stabilization procedures.


  • A Compact Calibratable Pulse Oximeter Based on Color Filters: Towards a Quantitative Analysis of Measurement Uncertainty

    by Wenze Wu, Finn-Niclas Stapelfeldt, Stefanie Kroker, Hutomo Suryo Wasisto, Andreas Waag

    Compact and low-cost opto-biomedical sensing systems today are ubiquitously available for measuring the oxygen saturation in blood. The oxygen saturation is derived by a complex, usually not well defined analytical process from the optical absorption of tissue at different wavelengths. The amount of information, which is originally contained in absorption measurements, is drastically reduced by this circumstance. However, the reliability of the analytical process as well as the influence of external parameters like blood pressures on the experimental uncertainty of such systems are widely unknown. Thus, to explore the experimental uncertainty quantitatively, original experimental data have to be used. In commercial systems, however, these data are usually not accessible. Therefore, test systems with full access to original absorption data are necessary. In this work, we develop and describe a test system consisting of color filters and a charge-coupled device (CCD) image sensor, which has substantial advantages in comparison to usually used systems based on multi-color light-emitting diodes (LEDs). Color filters with well-defined filter functions allow for a higher spectral resolution, and will finally guide the way to multi-spectral analysis of blood absorption measurements with reduced uncertainty.