Denis Savoie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Denis Savoie has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Bess Fang
LNE-SYRTE Observatoire de Paris Université PSL CNRS Sorbonne Université 61 Avenue de l'Observatoire 75014 Paris France
4 shared publications - Arnaud Landragin
LTE LNE Observatoire de Paris Université PSL Sorbonne Université Université de Lille CNRS 61 Avenue de l'Observatoire 75014 Paris France
3 shared publications - M. Altorio
LNE-SYRTE, Observatoire de Paris-Université PSL, CNRS, Sorbonne Université, 61 Avenue de l’Observatoire, 75014 Paris, France
3 shared publications - Remi Geiger
LNE-SYRTE Observatoire de Paris Université PSL CNRS Sorbonne Université 61 Avenue de l'Observatoire 75014 Paris France
3 shared publications A. Landragin
LNE-SYRTE, Observatoire de Paris, PSL Research University, CNRS, Sorbonne Universités, UPMC Univ. Paris 06, Paris, France
2 shared publicationsB. Venon
LNE-SYRTE, Observatoire de Paris, PSL Research University, CNRS, Sorbonne Universités, UPMC Univ. Paris 06, 61 avenue de l'Observatoire, 75014 Paris, France
2 shared publications
Latest Publications
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Fonctionnements continu et entrelacé d'un gyromètre à atomes froids et amélioration de sa stabilité
Les gyromètres Sagnac atomiques ont un grand potentiel en raison de leur sensibilité élevée à la rotation. Le gyromètre atomique du SYRTE utilise des atomes de césium refroidis par lasers. À l'aide de transitions Raman stimulées, nous formons un interféromètre de type Mach-Zehnder replié. L'instrument permet d'atteindre un temps d'interrogation maximal de 800 ms, ce qui correspond à une aire Sagnac de 11 cm², la plus grande démontrée pour un interféromètre atomique. Les objectifs de ma thèse sont de tirer au mieux parti du potentiel de l'instrument, et d'étudier des modes d'interrogations jointif et jointif entrelacé. C'est une étape importante pour l'application de tels instruments entre autres en navigation inertielle. Je décris les méthodes mises en place pour pousser la sensibilité court terme et mené une première étude détaillée des effets systématiques. Nous avons démontré une stabilité à court terme de 30nrad.s⁻¹.Hz^{-1/2} en interrogation jointive triplement entrelacée, ce qui est une amélioration d'un facteur 3 de l'état de l'art pour les gyromètres à atomes froids. L'état de l'art a également été amélioré d'un facteur 4 à long terme avec une stabilité de 0,2 nrad.s⁻¹ en 30 000 s.
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Fonctionnements continu et entrelacé d'un gyromètre à atomes froids et amélioration de sa stabilité
Les gyromètres Sagnac atomiques ont un grand potentiel en raison de leur sensibilité élevée à la rotation. Le gyromètre atomique du SYRTE utilise des atomes de césium refroidis par lasers. À l'aide de transitions Raman stimulées, nous formons un interféromètre de type Mach-Zehnder replié. L'instrument permet d'atteindre un temps d'interrogation maximal de 800 ms, ce qui correspond à une aire Sagnac de 11 cm², la plus grande démontrée pour un interféromètre atomique. Les objectifs de ma thèse sont de tirer au mieux parti du potentiel de l'instrument, et d'étudier des modes d'interrogations jointif et jointif entrelacé. C'est une étape importante pour l'application de tels instruments entre autres en navigation inertielle. Je décris les méthodes mises en place pour pousser la sensibilité court terme et mené une première étude détaillée des effets systématiques. Nous avons démontré une stabilité à court terme de 30nrad.s⁻¹.Hz^{-1/2} en interrogation jointive triplement entrelacée, ce qui est une amélioration d'un facteur 3 de l'état de l'art pour les gyromètres à atomes froids. L'état de l'art a également été amélioré d'un facteur 4 à long terme avec une stabilité de 0,2 nrad.s⁻¹ en 30 000 s.
- 10 March 2020
- Published by American Physical Society (APS) in Physical Review A
- Vol. 101 (3) , 033606
Accurate trajectory alignment in cold-atom interferometers with separated laser beams
Cold-atom interferometers commonly face systematic effects originating from the coupling between the trajectory of the atomic wave packet and the wavefront of the laser beams driving the interferometer. Detrimental for the accuracy and the stability of such inertial sensors, these systematics are particularly enhanced in architectures based on spatially separated laser beams. Here we analyze the effect of a coupling between the relative alignment of two separated laser beams and the trajectory of the atomic wave packet in a four-light-pulse cold-atom gyroscope operated in fountain configuration. We present a method to align the two laser beams at the level and to determine the optimal mean velocity of the atomic wave packet with an accuracy of . Such fine tuning constrains the associated gyroscope bias to a level of . In addition, we reveal this coupling using the point-source interferometry technique by analyzing single-shot time-of-flight fluorescence traces, which allows us to measure large angular misalignments between the interrogation beams. The alignment method which we present here can be employed in other sensor configurations and is particularly relevant to emerging gravitational wave detector concepts based on cold-atom interferometry.- 10 March 2020
- Published by American Physical Society (APS) in Physical Review A
- Vol. 101 (3) , 033606
Accurate trajectory alignment in cold-atom interferometers with separated laser beams
Cold-atom interferometers commonly face systematic effects originating from the coupling between the trajectory of the atomic wave packet and the wavefront of the laser beams driving the interferometer. Detrimental for the accuracy and the stability of such inertial sensors, these systematics are particularly enhanced in architectures based on spatially separated laser beams. Here we analyze the effect of a coupling between the relative alignment of two separated laser beams and the trajectory of the atomic wave packet in a four-light-pulse cold-atom gyroscope operated in fountain configuration. We present a method to align the two laser beams at the level and to determine the optimal mean velocity of the atomic wave packet with an accuracy of . Such fine tuning constrains the associated gyroscope bias to a level of . In addition, we reveal this coupling using the point-source interferometry technique by analyzing single-shot time-of-flight fluorescence traces, which allows us to measure large angular misalignments between the interrogation beams. The alignment method which we present here can be employed in other sensor configurations and is particularly relevant to emerging gravitational wave detector concepts based on cold-atom interferometry.- Open Access
- 7 December 2018
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 4 (12) , eaau7948
Interleaved atom interferometry for high-sensitivity inertial measurements
Cold-atom inertial sensors target several applications in navigation, geoscience, and tests of fundamental physics. Achieving high sampling rates and high inertial sensitivities, obtained with long interrogation times, represents a challenge for these applications. We report on the interleaved operation of a cold-atom gyroscope, where three atomic clouds are interrogated simultaneously in an atom interferometer featuring a sampling rate of 3.75 Hz and an interrogation time of 801 ms. Interleaving improves the inertial sensitivity by efficiently averaging vibration noise and allows us to perform dynamic rotation measurements in a so far unexplored range. We demonstrate a stability of 3 × 10−10 rad s−1 , which competes with the best stability levels obtained with fiber-optic gyroscopes. Our work validates interleaving as a key concept for future atom-interferometry sensors probing time-varying signals, as in on-board navigation and gravity gradiometry, searches for dark matter, or gravitational wave detection.
- 7 December 2018
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 4 (12) , eaau7948
Open AccessInterleaved atom interferometry for high-sensitivity inertial measurements
Cold-atom inertial sensors target several applications in navigation, geoscience, and tests of fundamental physics. Achieving high sampling rates and high inertial sensitivities, obtained with long interrogation times, represents a challenge for these applications. We report on the interleaved operation of a cold-atom gyroscope, where three atomic clouds are interrogated simultaneously in an atom interferometer featuring a sampling rate of 3.75 Hz and an interrogation time of 801 ms. Interleaving improves the inertial sensitivity by efficiently averaging vibration noise and allows us to perform dynamic rotation measurements in a so far unexplored range. We demonstrate a stability of 3 × 10−10 rad s−1 , which competes with the best stability levels obtained with fiber-optic gyroscopes. Our work validates interleaving as a key concept for future atom-interferometry sensors probing time-varying signals, as in on-board navigation and gravity gradiometry, searches for dark matter, or gravitational wave detection.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 798-799
High-sensitivity cold-atom gyroscope with real-time vibration compensation
Our cold-atom gyroscope is based on a four-pulse configuration with a very large Sagnac area. Its short-term stability is limited by aliasing effects of the inertial forces (acceleration and rotation). We will show how continuous measurements and real-time compensation of the vibration during the interferometer sequence overcome this limit.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 798-799
High-sensitivity cold-atom gyroscope with real-time vibration compensation
Our cold-atom gyroscope is based on a four-pulse configuration with a very large Sagnac area. Its short-term stability is limited by aliasing effects of the inertial forces (acceleration and rotation). We will show how continuous measurements and real-time compensation of the vibration during the interferometer sequence overcome this limit.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Cold-atom inertial sensor without deadtime
We report the operation of a cold-atom inertial sensor in a joint interrogation scheme, where we simultaneously prepare a cold-atom source and operate an atom interferometer in order to eliminate dead times [1]. This is illustrated in Fig. 1. Dead times and noise aliasing are consequences of the sequential operation which is intrinsic to cold-atom interferometers. Both phenomena have deleterious effects on the performance of these sensors. We show that our continuous operation improves the short-term sensitivity of atom interferometers, by demonstrating a record rotation sensitivity of 100 nrad.s -1 /√Hz in a cold-atom gyroscope of 11 cm 2 Sagnac area. We also demonstrate a rotation stability of 1 nrad.s -1 after 10 4 s of integration, improving previous results by an order of magnitude [2-4]. We expect that the continuous operation will allow cold-atom inertial sensors with long interrogation time to reach their full sensitivity, determined by the quantum noise limit.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Cold-atom inertial sensor without deadtime
We report the operation of a cold-atom inertial sensor in a joint interrogation scheme, where we simultaneously prepare a cold-atom source and operate an atom interferometer in order to eliminate dead times [1]. This is illustrated in Fig. 1. Dead times and noise aliasing are consequences of the sequential operation which is intrinsic to cold-atom interferometers. Both phenomena have deleterious effects on the performance of these sensors. We show that our continuous operation improves the short-term sensitivity of atom interferometers, by demonstrating a record rotation sensitivity of 100 nrad.s -1 /√Hz in a cold-atom gyroscope of 11 cm 2 Sagnac area. We also demonstrate a rotation stability of 1 nrad.s -1 after 10 4 s of integration, improving previous results by an order of magnitude [2-4]. We expect that the continuous operation will allow cold-atom inertial sensors with long interrogation time to reach their full sensitivity, determined by the quantum noise limit.
- 25 April 2016
- Published by EDP Sciences in Revue française de métrologie
- No. 41,p. 21-27
Gyromètre à atomes froids de grande sensibilité
- 25 April 2016
- Published by EDP Sciences in Revue française de métrologie
- No. 41,p. 21-27
Gyromètre à atomes froids de grande sensibilité