Yangqiu Xia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yangqiu Xia has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Qiu Hu
Institute of Machinery Manufacturing Technology, China Academy of Engineering Physics, Mianyang, China
3 shared publications- Liang Mi
CAEP, Inst Machinery Mfg Technol, Mianyang, Sichuan, Peoples R China
2 shared publications Mengyang Li
, China Academy of Engineering Physics Institute of Machinery Manufacturing Technology, Mianyang, CHINA
2 shared publicationsMing Huang
, China Academy of Engineering Physics Institute of Machinery Manufacturing Technology, Mianyang, CHINA
2 shared publicationsQiang Tang
, China Academy of Engineering Physics Institute of Machinery Manufacturing Technology, Mianyang, CHINA
2 shared publications- Qiang Tang
CAEP, Inst Machinery Mfg Technol, Mianyang, Sichuan, Peoples R China
2 shared publications
Latest Publications
- 20 July 2023
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 28 (1) , 181-190
An improved angle calibration method of a high-precision angle comparator
- 20 July 2023
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 28 (1) , 181-190
An improved angle calibration method of a high-precision angle comparator
- Open Access
- 30 November 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (12) , 2121
Radial Error Motion Measurement and Its Uncertainty Estimation of Ultra Precision Axes of Rotation with Nanometer Level Precision
The radial error is the key performance indicator of ultra-precision axis. In order to measure and evaluate the radial error of ultra-precision axis with nanometer accuracy, a measurement system with an accuracy of nanometer based on capacitive displacement probes and standard spheres is developed. The nonlinearity error of capacitive displacement probes, misalignment error of the probes, eccentric error of standard spheres, error caused by environment temperature change, environment vibration and error separation methods are analyzed and the effects of the above factors are obtained; Multiple measurement examples carried out with the measurement system this paaper constructed indicate the repeatability of the measurement system reaches 10.5 nm and the roundness error of artifact separated is less than 4.03 nm. In order to evaluate the measurement dispersion of the ultra-precision axis radial error, the major uncertainty components and the complete process of the comprehensive evaluation of the measurement uncertainty are proposed. The combined uncertainty of radial error motion measurement of the ultra-precision axis with Donaldson reversal is 31.64 nm (k = 2).
- 30 November 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (12) , 2121
Open AccessRadial Error Motion Measurement and Its Uncertainty Estimation of Ultra Precision Axes of Rotation with Nanometer Level Precision
The radial error is the key performance indicator of ultra-precision axis. In order to measure and evaluate the radial error of ultra-precision axis with nanometer accuracy, a measurement system with an accuracy of nanometer based on capacitive displacement probes and standard spheres is developed. The nonlinearity error of capacitive displacement probes, misalignment error of the probes, eccentric error of standard spheres, error caused by environment temperature change, environment vibration and error separation methods are analyzed and the effects of the above factors are obtained; Multiple measurement examples carried out with the measurement system this paaper constructed indicate the repeatability of the measurement system reaches 10.5 nm and the roundness error of artifact separated is less than 4.03 nm. In order to evaluate the measurement dispersion of the ultra-precision axis radial error, the major uncertainty components and the complete process of the comprehensive evaluation of the measurement uncertainty are proposed. The combined uncertainty of radial error motion measurement of the ultra-precision axis with Donaldson reversal is 31.64 nm (k = 2).
- Open Access
- 14 October 2019
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (2) , 025007
Evaluation of measurement uncertainty for a high-precision angle comparator with a vacuum preloaded structure
Angle measurement is widely used in various fields of science and technology. With the development of technology, the measurement uncertainty of angle metrology becomes more and more demanding. To achieve high-precision calibration of a high-precision angle comparator with a sub-arc-second level, a method of angle position error calibration and measurement uncertainty evaluation based on no material reference was established. Firstly, the structure of the angle comparator with a vacuum preloaded air bearing driven by an ultrasonic motor drive and the construction of the whole calibration system are briefly introduced. Then, the basic principle, algorithm and error separation principle of angle calibration based on the optical angle measurement method were studied, and the test process is introduced. Finally, the measurement results and error sources were analyzed, the measurement uncertainty model was established and the measurement uncertainty was evaluated. The experimental results show that the high-precision angle comparator with a vacuum preloaded structure has an angle position error of 0.12″ and a measurement uncertainty of 0.05″ (k = 2). Through many experiments, it is shown that the measurement system has a stable high-precision calibration capability with a sub-arc-second level for circular division artifacts.
- 14 October 2019
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (2) , 025007
Open AccessEvaluation of measurement uncertainty for a high-precision angle comparator with a vacuum preloaded structure
Angle measurement is widely used in various fields of science and technology. With the development of technology, the measurement uncertainty of angle metrology becomes more and more demanding. To achieve high-precision calibration of a high-precision angle comparator with a sub-arc-second level, a method of angle position error calibration and measurement uncertainty evaluation based on no material reference was established. Firstly, the structure of the angle comparator with a vacuum preloaded air bearing driven by an ultrasonic motor drive and the construction of the whole calibration system are briefly introduced. Then, the basic principle, algorithm and error separation principle of angle calibration based on the optical angle measurement method were studied, and the test process is introduced. Finally, the measurement results and error sources were analyzed, the measurement uncertainty model was established and the measurement uncertainty was evaluated. The experimental results show that the high-precision angle comparator with a vacuum preloaded structure has an angle position error of 0.12″ and a measurement uncertainty of 0.05″ (k = 2). Through many experiments, it is shown that the measurement system has a stable high-precision calibration capability with a sub-arc-second level for circular division artifacts.
- Open Access
- 26 December 2018
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 10 (12)
Development of comprehensive performance testing technology for motorized spindle
The comprehensive performance test of motorized spindle will contribute to improve the machining quality of machine tool. But existing standards for testing the performance of motorized spindle are limited to test its partial static and dynamic performances. Meantime, most of the researches only focus on the vibration, thermal deformation, and rotary accuracy of motorized spindle. Consequently, how to accurately and comprehensively test the performance of motorized spindle is the key problem. For solving this problem, a comprehensive testing technology is presented in this article. In detail, some principles for establishing a test index system are proposed. And, by synthetically and systematically analyzing the process of structural design, manufacturing and assembly, use, and service, an index system for characterizing the comprehensive performance of motorized spindle is built. Then, some operational test methods are provided to evaluate the selected indexes. Finally, the proposed technology is taken to test a motorized spindle. In brief, the proposed technology will make the performance test of motorized spindle more comprehensive and operational and can provide support for improving the comprehensive performance of the motorized spindle.
- 26 December 2018
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 10 (12)
Open AccessDevelopment of comprehensive performance testing technology for motorized spindle
The comprehensive performance test of motorized spindle will contribute to improve the machining quality of machine tool. But existing standards for testing the performance of motorized spindle are limited to test its partial static and dynamic performances. Meantime, most of the researches only focus on the vibration, thermal deformation, and rotary accuracy of motorized spindle. Consequently, how to accurately and comprehensively test the performance of motorized spindle is the key problem. For solving this problem, a comprehensive testing technology is presented in this article. In detail, some principles for establishing a test index system are proposed. And, by synthetically and systematically analyzing the process of structural design, manufacturing and assembly, use, and service, an index system for characterizing the comprehensive performance of motorized spindle is built. Then, some operational test methods are provided to evaluate the selected indexes. Finally, the proposed technology is taken to test a motorized spindle. In brief, the proposed technology will make the performance test of motorized spindle more comprehensive and operational and can provide support for improving the comprehensive performance of the motorized spindle.
- Open Access
- 9 February 2017
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 95, 07022
Calibration of an Indexing Table Using a High Precision Angle Comparator
MATEC Web of Conferences, open access proceedings in Materials science, Engineering and Chemistry
- 9 February 2017
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 95, 07022
Open AccessCalibration of an Indexing Table Using a High Precision Angle Comparator
MATEC Web of Conferences, open access proceedings in Materials science, Engineering and Chemistry
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 100-104
Random vibration reliability analysis of disc magazine based on the peak beyond method
In order to analyze the effect of random vibration on the accuracy of disc magazine in tool changing process, dimensionless dynamics model of tool change system is established, using the model to study the random vibration of disc magazine in tool changing process. Through the study of peak beyond as basis failure criterion for evaluation of vibration reliability, a vibration reliability analysis method is developed by using the peak beyond method to evaluate the system reliability. And the vibration reliability of a disc magazine is calculated by Matlab simulation, the calculation results show that the randomness of system parameters in a controllable range can ensure the system vibration reliability.
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 100-104
Random vibration reliability analysis of disc magazine based on the peak beyond method
In order to analyze the effect of random vibration on the accuracy of disc magazine in tool changing process, dimensionless dynamics model of tool change system is established, using the model to study the random vibration of disc magazine in tool changing process. Through the study of peak beyond as basis failure criterion for evaluation of vibration reliability, a vibration reliability analysis method is developed by using the peak beyond method to evaluate the system reliability. And the vibration reliability of a disc magazine is calculated by Matlab simulation, the calculation results show that the randomness of system parameters in a controllable range can ensure the system vibration reliability.