Jarrod Schiffbauer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jarrod Schiffbauer has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Evgeny A. Demekhin
Laboratory of Micro- and Nanoscale Electro- and Hydrodynamics, Financial University under the Government of the Russian Federation, Moscow, Russia
3 shared publications - Georgy S. Ganchenko
Financial University under the Government of the Russian Federation, Moscow, Russia
3 shared publications - Davin Lemmon
Department of Biomedical Engineering and Chemical Engineering, Klesse College of Engineering and Integrated Design, University of Texas at San Antonio, San Antonio, TX 78249, USA
1 shared publication - Gabriel Lopez
Department of Physics, School of Science, Indiana University Indianapolis, Indianapolis, IN 46202, USA
1 shared publication - Gongchen Sun
Department of Biomedical Engineering and Chemical Engineering, The University of Texas at San Antonio, San Antonio, TX 78249, USA
1 shared publication Marygrace Prinster
1 shared publication
Latest Publications
- Open Access
Harnessing C. elegans as a Biosensor: Integrating Microfluidics, Image Analysis, and Machine Learning for Environmental Sensing
Environmental contamination is becoming an increasingly evident risk to human health worldwide. The small, free-living nematode Caenorhabditis elegans (C. elegans) has become a compelling model organism for environmental toxicity studies in recent years, owing to its numerous advantages, including its transparent body, small size, well-characterized biology, genetic tractability, short lifespan, and ease of culture. Several assays have been developed using C. elegans to enable a better understanding of toxicant effects, from whole-animal to single-cell levels. While these methods can be extremely useful, they can be time-consuming and cumbersome to perform on a large scale. Recent advances in microfluidics have adapted many of these assays to enable high-throughput analysis of C. elegans, greatly reducing time and resource consumption while increasing efficiency and scalability. Further integration of these microfluidic platforms with machine learning expands their analytical capabilities and accuracy, revolutionizing what can be achieved with this model organism. This article will review the physiological basis of C. elegans as a model organism for environmental toxicity studies, and recent advances in integrating microfluidics and machine learning which could lead to using C. elegans as a promising living biosensor for environmental sensing.
Open AccessHarnessing C. elegans as a Biosensor: Integrating Microfluidics, Image Analysis, and Machine Learning for Environmental Sensing
Environmental contamination is becoming an increasingly evident risk to human health worldwide. The small, free-living nematode Caenorhabditis elegans (C. elegans) has become a compelling model organism for environmental toxicity studies in recent years, owing to its numerous advantages, including its transparent body, small size, well-characterized biology, genetic tractability, short lifespan, and ease of culture. Several assays have been developed using C. elegans to enable a better understanding of toxicant effects, from whole-animal to single-cell levels. While these methods can be extremely useful, they can be time-consuming and cumbersome to perform on a large scale. Recent advances in microfluidics have adapted many of these assays to enable high-throughput analysis of C. elegans, greatly reducing time and resource consumption while increasing efficiency and scalability. Further integration of these microfluidic platforms with machine learning expands their analytical capabilities and accuracy, revolutionizing what can be achieved with this model organism. This article will review the physiological basis of C. elegans as a model organism for environmental toxicity studies, and recent advances in integrating microfluidics and machine learning which could lead to using C. elegans as a promising living biosensor for environmental sensing.
- Open Access
Transport Regimes of Underdamped Brownian Particles in a Tilted Washboard Potential
In this paper, a comprehensive examination of the temperature- and bias-dependent diffusion regimes of underdamped Brownian particles is presented. A temperature threshold for a transition between anomalous and normal diffusive behaviors is located, yielding a new phase diagram for the system. In the low-temperature regime, the system exhibits an apparent negative differential mobility due to persistent, long-time subdiffusion at low-bias; at high temperature (or critical bias,) the system rapidly approaches normal diffusion below an intermediate barrier height, $U_o \sim k_B T$. By consideration of numerical results, comparison to the overdamped case, and the related Kramers multistable escape problems, it is demonstrated that the low-bias non-monotonic temperature dependence of the diffusivity, persistent subdiffusion, and negative differential mobility can be traced to inertial effects, which are evident in the oscillatory modes of the velocity power spectra at low bias. In the giant diffusion regime, the velocity power spectra exhibit coupling between the ``locked" and ``running" states, with a characteristic frequency corresponding to the principal frequency of the limit cycles of a damped, driven plane pendulum near critical bias. Non-linear second harmonic generation, corresponding to oscillatory transient anomalous diffusivity, is observed with increasing bias and decreasing temperature, further emphasizing that the low-noise diffusion problem converges to noise-free dynamics, complementing analytic results for the average velocity [L. Cheng and N.K. Yip, Physica D, 2015].Open AccessTransport Regimes of Underdamped Brownian Particles in a Tilted Washboard Potential
In this paper, a comprehensive examination of the temperature- and bias-dependent diffusion regimes of underdamped Brownian particles is presented. A temperature threshold for a transition between anomalous and normal diffusive behaviors is located, yielding a new phase diagram for the system. In the low-temperature regime, the system exhibits an apparent negative differential mobility due to persistent, long-time subdiffusion at low-bias; at high temperature (or critical bias,) the system rapidly approaches normal diffusion below an intermediate barrier height, $U_o \sim k_B T$. By consideration of numerical results, comparison to the overdamped case, and the related Kramers multistable escape problems, it is demonstrated that the low-bias non-monotonic temperature dependence of the diffusivity, persistent subdiffusion, and negative differential mobility can be traced to inertial effects, which are evident in the oscillatory modes of the velocity power spectra at low bias. In the giant diffusion regime, the velocity power spectra exhibit coupling between the ``locked" and ``running" states, with a characteristic frequency corresponding to the principal frequency of the limit cycles of a damped, driven plane pendulum near critical bias. Non-linear second harmonic generation, corresponding to oscillatory transient anomalous diffusivity, is observed with increasing bias and decreasing temperature, further emphasizing that the low-noise diffusion problem converges to noise-free dynamics, complementing analytic results for the average velocity [L. Cheng and N.K. Yip, Physica D, 2015]. - 23 September 2021
- Published by Wiley in Electrophoresis
- Vol. 42 (23) , 2511-2518
Novel electroosmotic micromixer configuration based on ion‐selective microsphere
In this paper, a micromixer of a new configuration is presented, consisting of a spherical chamber in the center of which an ion‐selective microsphere is placed. Stratified liquid is introduced through the chamber via inlet and outlet holes under an external pressure gradient and an external electric field is directed in such a way that the resulting electroosmotic flow is directed against the pressure‐driven flow, resulting in mixing. The investigation is carried out by direct numerical simulation on a super‐computer. Optimal values of the applied electric field are determined to yield strong mixing. Above this optimal mixing regime, a number of instabilities and bifurcations are realized, which qualitatively coincide with those occurring during electrophoresis of an ion‐selective microgranule. As shown by our calculation, these instabilities do not lead to an enhanced mixing. The resulting electroconvective vortices remain confined near the surface of the microgranule, and do not sufficiently perturb the stratified fluid flow further from the granule. On the other hand, another type of instability caused by the salt concentration gradient can generate sufficiently strong oscillations to enhance mixing. However, this only occurs when the external electric field is sufficiently high that the electroosmotic flow is comparable to the pressure‐driven flow. This ultimately leads to creation of reverse flows of the liquid and cessation of the device operation. Thus, it was shown that the best mixing occurs in the absence of electrokinetic instability. Based on the data obtained, it is possible to select the necessary geometric characteristics of the micromixer to achieve the optimal mixing mode for a given set of liquids, which may be ten times more effective than passive mixers at the same flow rates. A comparison with the experimental data of the other authors confirms the effectiveness of this device and its other capabilities. Furthermore, the basic device design can be operated in other modes, for example, an electrohydrodynamic pump, a streaming current generator, or even a micro‐reactor, depending on the system parameters and choice of an ion‐selective granule.
- 23 September 2021
- Published by Wiley in Electrophoresis
- Vol. 42 (23) , 2511-2518
Novel electroosmotic micromixer configuration based on ion‐selective microsphere
In this paper, a micromixer of a new configuration is presented, consisting of a spherical chamber in the center of which an ion‐selective microsphere is placed. Stratified liquid is introduced through the chamber via inlet and outlet holes under an external pressure gradient and an external electric field is directed in such a way that the resulting electroosmotic flow is directed against the pressure‐driven flow, resulting in mixing. The investigation is carried out by direct numerical simulation on a super‐computer. Optimal values of the applied electric field are determined to yield strong mixing. Above this optimal mixing regime, a number of instabilities and bifurcations are realized, which qualitatively coincide with those occurring during electrophoresis of an ion‐selective microgranule. As shown by our calculation, these instabilities do not lead to an enhanced mixing. The resulting electroconvective vortices remain confined near the surface of the microgranule, and do not sufficiently perturb the stratified fluid flow further from the granule. On the other hand, another type of instability caused by the salt concentration gradient can generate sufficiently strong oscillations to enhance mixing. However, this only occurs when the external electric field is sufficiently high that the electroosmotic flow is comparable to the pressure‐driven flow. This ultimately leads to creation of reverse flows of the liquid and cessation of the device operation. Thus, it was shown that the best mixing occurs in the absence of electrokinetic instability. Based on the data obtained, it is possible to select the necessary geometric characteristics of the micromixer to achieve the optimal mixing mode for a given set of liquids, which may be ten times more effective than passive mixers at the same flow rates. A comparison with the experimental data of the other authors confirms the effectiveness of this device and its other capabilities. Furthermore, the basic device design can be operated in other modes, for example, an electrohydrodynamic pump, a streaming current generator, or even a micro‐reactor, depending on the system parameters and choice of an ion‐selective granule.
- Open Access
- 7 September 2020
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 21 (18) , 6526
Transitions and Instabilities in Imperfect Ion-Selective Membranes
Numerical investigation of the underlimiting, limiting, and overlimiting current modes and their transitions in imperfect ion-selective membranes with fluid flow through permitted through the membrane is presented. The system is treated as a three layer composite system of electrolyte-porous membrane-electrolyte where the Nernst–Planck–Poisson–Stokes system of equations is used in the electrolyte, and the Darcy–Brinkman approach is employed in the nanoporous membrane. In order to resolve thin Debye and Darcy layers, quasi-spectral methods are applied using Chebyshev polynomials for their accumulation of zeros and, hence, best resolution in the layers. The boundary between underlimiting and overlimiting current regimes is subject of linear stability analysis, where the transition to overlimiting current is assumed due to the electrokinetic instability of the one-dimensional quiescent state. However, the well-developed overlimiting current is inherently a problem of nonlinear stability and is subject of the direct numerical simulation of the full system of equations. Both high and low fixed charge density membranes (low- and high concentration electrolyte solutions), acting respectively as (nearly) perfect or imperfect membranes, are considered. The perfect membrane is adequately described by a one-layer model while the imperfect membrane has a more sophisticated response. In particular, the direct transition from underlimiting to overlimiting currents, bypassing the limiting currents, is found to be possible for imperfect membranes (high-concentration electrolyte). The transition to the overlimiting currents for the low-concentration electrolyte solutions is monotonic, while for the high-concentration solutions it is oscillatory. Despite the fact that velocities in the porous membrane are much smaller than in the electrolyte region, it is further demonstrated that they can dramatically influence the nature and transition to the overlimiting regimes. A map of the bifurcations, transitions, and regimes is constructed in coordinates of the fixed membrane charge and the Darcy number.
- 7 September 2020
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 21 (18) , 6526
Open AccessTransitions and Instabilities in Imperfect Ion-Selective Membranes
Numerical investigation of the underlimiting, limiting, and overlimiting current modes and their transitions in imperfect ion-selective membranes with fluid flow through permitted through the membrane is presented. The system is treated as a three layer composite system of electrolyte-porous membrane-electrolyte where the Nernst–Planck–Poisson–Stokes system of equations is used in the electrolyte, and the Darcy–Brinkman approach is employed in the nanoporous membrane. In order to resolve thin Debye and Darcy layers, quasi-spectral methods are applied using Chebyshev polynomials for their accumulation of zeros and, hence, best resolution in the layers. The boundary between underlimiting and overlimiting current regimes is subject of linear stability analysis, where the transition to overlimiting current is assumed due to the electrokinetic instability of the one-dimensional quiescent state. However, the well-developed overlimiting current is inherently a problem of nonlinear stability and is subject of the direct numerical simulation of the full system of equations. Both high and low fixed charge density membranes (low- and high concentration electrolyte solutions), acting respectively as (nearly) perfect or imperfect membranes, are considered. The perfect membrane is adequately described by a one-layer model while the imperfect membrane has a more sophisticated response. In particular, the direct transition from underlimiting to overlimiting currents, bypassing the limiting currents, is found to be possible for imperfect membranes (high-concentration electrolyte). The transition to the overlimiting currents for the low-concentration electrolyte solutions is monotonic, while for the high-concentration solutions it is oscillatory. Despite the fact that velocities in the porous membrane are much smaller than in the electrolyte region, it is further demonstrated that they can dramatically influence the nature and transition to the overlimiting regimes. A map of the bifurcations, transitions, and regimes is constructed in coordinates of the fixed membrane charge and the Darcy number.
- 1 November 2018
- Published by AIP Publishing in Biomicrofluidics
- Vol. 12 (6) , 064107
Overlimiting current due to electro-diffusive amplification of the second Wien effect at a cation-anion bipolar membrane junction
Numerical simulations are presented for the transient and steady-state response of a model electrodiffusive cell with a bipolar ion-selective membrane under electric current. The model uses a continuum Poisson-Nernst-Planck theory including source terms to account for the catalytic second Wien effect between ionogenic groups in the membranes and resolves the Debye layers at interfaces. The resulting electric field at the membrane junction is increased by as much as four orders of magnitude in comparison to the field external to the membrane. This leads to a significant amplification of the second Wien effect, creating an increased ionic flux due to the catalytic decomposition of water. The effect also induces an exaltation effect wherein the salt ion flux undergoes a concomitant increase as well. The interplay of effects results in a unique over-limiting current mechanism due to concentration polarization internal, rather than external, to the membranes. In addition to the case of two equal but oppositely charged membranes under the standard simplifying assumption of equal ionic diffusivities, two variations on this model are studied. Asymmetric diffusivities, representative of the actual mobility difference in dissociated water ions, and the effect of the membrane charge density ratio were also considered. The latter elucidates an overlimiting current shift mechanism for DNA adsorption on anion-selective membranes proposed by Slouka et al. [Langmuir 29, 8275 (2013)]. The former provides more realistic picture of multi-ion transport and demonstrates a surprising steady-state effect due to the asymmetry in the diffusivity of hydroxide and hydronium.
- 1 November 2018
- Published by AIP Publishing in Biomicrofluidics
- Vol. 12 (6) , 064107
Overlimiting current due to electro-diffusive amplification of the second Wien effect at a cation-anion bipolar membrane junction
Numerical simulations are presented for the transient and steady-state response of a model electrodiffusive cell with a bipolar ion-selective membrane under electric current. The model uses a continuum Poisson-Nernst-Planck theory including source terms to account for the catalytic second Wien effect between ionogenic groups in the membranes and resolves the Debye layers at interfaces. The resulting electric field at the membrane junction is increased by as much as four orders of magnitude in comparison to the field external to the membrane. This leads to a significant amplification of the second Wien effect, creating an increased ionic flux due to the catalytic decomposition of water. The effect also induces an exaltation effect wherein the salt ion flux undergoes a concomitant increase as well. The interplay of effects results in a unique over-limiting current mechanism due to concentration polarization internal, rather than external, to the membranes. In addition to the case of two equal but oppositely charged membranes under the standard simplifying assumption of equal ionic diffusivities, two variations on this model are studied. Asymmetric diffusivities, representative of the actual mobility difference in dissociated water ions, and the effect of the membrane charge density ratio were also considered. The latter elucidates an overlimiting current shift mechanism for DNA adsorption on anion-selective membranes proposed by Slouka et al. [Langmuir 29, 8275 (2013)]. The former provides more realistic picture of multi-ion transport and demonstrates a surprising steady-state effect due to the asymmetry in the diffusivity of hydroxide and hydronium.