Wendi Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wendi Gao has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Dong Sun
Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, China
13 shared publications - Libo Zhao
School of Instrument Science and Technology, Xi’an Jiaotong University, Xi’an, China
11 shared publications Zhuangde Jiang
State Key Laboratory for Manufacturing Systems Engineering, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Overseas Expertise Introduction Center for Micro/Nano Manufacturing and Nano Measurement Technologies Discipline Innovation, Xi'an Jiaotong University (Yantai) Research Institute for Intelligent Sensing Technology and System, School of Instrument Science and Technology, Xi'an Jiaotong University 1 , Xi'an 710049
6 shared publications- Tao Luo
School of Intelligent Manufacturing (Pen-Tung Sah Institute of Micro-Nano Science and Technology), Xiamen University, Xiamen, China
4 shared publications - Wenji Cui
Department of Gastroenterology, the Second Affiliated Hospital, Xian Jiaotong University, Xian 710004, China, also with the State Key Laboratory for Manufacturing Systems Engineering, the State Industry-Education Integration Center for Medical Innovations, the International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Shaanxi Innovation Center for Special Sensing and Testing Technology in Extreme Environments, and the School of Instrument Science and Technology
4 shared publications - Zhuangde Jiang
State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, China
4 shared publications
Latest Publications
- 2 November 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (18)
Manipulation of aqueous droplets in oil using contactless ultrasound
Acoustic droplet manipulation is widely used in biochemical analysis due to its excellent biocompatibility and non-contact operation. However, conventional methods performed in air suffer from aerosol-induced sample cross-contamination. To address this limitation, we propose a quad-focused acoustic tweezer (QFAT) system composed of four ultrasonic transducers orthogonally arranged with a 45° inclination angle. The interference of multiple acoustic beams in the oil phase generates a low-pressure acoustic potential well, and the resulting acoustic radiation force enables non-contact droplet manipulation. Benefiting from the intrinsic isolation of aqueous droplets by oil phase, the system significantly reduces the risk of aerosol contamination. The QFAT enables stable droplet transport and, when integrated with an automated three-axis translation stage, guides droplets along complex trajectories such as circles and hexagons with high precision. In addition, the system supports parallel collective transport of multiple droplets for orderly multi-step chemical reactions, demonstrating strong potential for parallel biochemical manipulation in oil-phase environments. This work provides a robust and highly flexible non-contact droplet manipulation method with significantly reduced contamination risks for droplet-based biochemical analysis and synthesis.
- 2 November 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (18)
Manipulation of aqueous droplets in oil using contactless ultrasound
Acoustic droplet manipulation is widely used in biochemical analysis due to its excellent biocompatibility and non-contact operation. However, conventional methods performed in air suffer from aerosol-induced sample cross-contamination. To address this limitation, we propose a quad-focused acoustic tweezer (QFAT) system composed of four ultrasonic transducers orthogonally arranged with a 45° inclination angle. The interference of multiple acoustic beams in the oil phase generates a low-pressure acoustic potential well, and the resulting acoustic radiation force enables non-contact droplet manipulation. Benefiting from the intrinsic isolation of aqueous droplets by oil phase, the system significantly reduces the risk of aerosol contamination. The QFAT enables stable droplet transport and, when integrated with an automated three-axis translation stage, guides droplets along complex trajectories such as circles and hexagons with high precision. In addition, the system supports parallel collective transport of multiple droplets for orderly multi-step chemical reactions, demonstrating strong potential for parallel biochemical manipulation in oil-phase environments. This work provides a robust and highly flexible non-contact droplet manipulation method with significantly reduced contamination risks for droplet-based biochemical analysis and synthesis.
- 31 October 2026
- Published by Zhejiang University Press in Journal of Zhejiang University-SCIENCE A
- Vol. 27 (10) , 1138-1152
Hybrid integration of flexible temperature and humidity sensors with crosstalk decoupling for wearable physiological monitoring
Accurate, synchronous monitoring of respiratory and cutaneous temperature and humidity is essential for assessing pulmonary function and exercise-induced m
- 31 October 2026
- Published by Zhejiang University Press in Journal of Zhejiang University-SCIENCE A
- Vol. 27 (10) , 1138-1152
Hybrid integration of flexible temperature and humidity sensors with crosstalk decoupling for wearable physiological monitoring
Accurate, synchronous monitoring of respiratory and cutaneous temperature and humidity is essential for assessing pulmonary function and exercise-induced m
- 28 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-13
Automated and Near-Flawless Micropipette PIH Assembly to MEMS Nanoforce Sensor With A Robotic Microscopy System
Peg-in-hole (PIH) assembly of micropipettes to micro-electromechanical system (MEMS) nanoforce sensors can be performed to improve spatial probing resolution and operation space, but their spatial attitude angle deviations and off-axial distances lead to unstable assembly, sensor performance deterioration, and even structural damage. In this article, an automated and near-flawless micropipette PIH assembly method was proposed based on the built robotic microscopy system, to the best of our knowledge, for the first time. Utilizing an ISPR-based method with a mechanical equilibrium model and a sliding mode controller, the planar deflection angle was adjusted below 0.07 ${}^{\boldsymbol{\circ}}$ without being pushed out of FOV. The out-of-plane inclination angle was then reduced to below 0.05 ${}^{\boldsymbol{\circ}}$ by the proposed GTC-based method, whose depth is obtained from a feasible FDTBR inclination metrology and mechanical contact model. The off-axial distance was actively adjusted by an AIHM-based recenter method during sensor probe insertion, leading to a high assembly successful rate of 100% with negligible contact forces of 1.64 ${\boldsymbol{\mu}}$ N. The methodology effectiveness was validated through calibration tests, wherein no structural damage and performance deterioration were produced on the processed sensor for a long-term usage, indicating its great potential in nanoforce measurement.
- 28 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-13
Automated and Near-Flawless Micropipette PIH Assembly to MEMS Nanoforce Sensor With A Robotic Microscopy System
Peg-in-hole (PIH) assembly of micropipettes to micro-electromechanical system (MEMS) nanoforce sensors can be performed to improve spatial probing resolution and operation space, but their spatial attitude angle deviations and off-axial distances lead to unstable assembly, sensor performance deterioration, and even structural damage. In this article, an automated and near-flawless micropipette PIH assembly method was proposed based on the built robotic microscopy system, to the best of our knowledge, for the first time. Utilizing an ISPR-based method with a mechanical equilibrium model and a sliding mode controller, the planar deflection angle was adjusted below 0.07 ${}^{\boldsymbol{\circ}}$ without being pushed out of FOV. The out-of-plane inclination angle was then reduced to below 0.05 ${}^{\boldsymbol{\circ}}$ by the proposed GTC-based method, whose depth is obtained from a feasible FDTBR inclination metrology and mechanical contact model. The off-axial distance was actively adjusted by an AIHM-based recenter method during sensor probe insertion, leading to a high assembly successful rate of 100% with negligible contact forces of 1.64 ${\boldsymbol{\mu}}$ N. The methodology effectiveness was validated through calibration tests, wherein no structural damage and performance deterioration were produced on the processed sensor for a long-term usage, indicating its great potential in nanoforce measurement.
- 14 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. PP (10834435) , 1-12
A Biaxial MEMS Capacitive Nanoforce Sensor Based on a Novel Bistable Bioinspired Swallow Structure for Somatic Cell Micromanipulation
Precise measurement of ultralow biaxial forces at the nano-Newton (nN) level is highly demanded for robotic micromanipulation of somatic cells. A novel microelectromechanical system capacitive nanoforce sensor was proposed to address this demand. Inspired by the stable gliding gestures of a swallow, a bistable swallow structure was introduced, offering high deformation flexibility with negligible mechanical cross-axis coupling. Considering its mechanical behaviors, a comb configuration and interconnection strategy were proposed to eliminate internal electrostatic coupling rotation. The fabricated sensor was packaged with a time-division multiplexing-based readout circuit, comprising a compact measurement system. The x-axis force sensitivity reached 0.9893 fF/nN, with a high resolution of 0.3658 nN and a linearity of 0.9994 over a range of 8.02 μN. Besides, the y-axis force sensitivity reached 0.2683 fF/nN, with a resolution of 0.8244 nN and a linearity of 0.9995 over a range of 8.11 μN. The noise floor was lower than 0.0665 nN/$\sqrt {\mathbf{Hz}} $ and 0.1688 nN/$\sqrt {\mathbf{Hz}} $ for x- and y-axes, respectively, and the cross-axis coupling error ratios were only 0.15% and 0.36%, respectively. The proposed sensor was adopted to manipulate mouse myoblast cells, allowing nN-level biaxial interaction force responses to be measured in real-time robotic manipulation for the first time.
- 14 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. PP (10834435) , 1-12
A Biaxial MEMS Capacitive Nanoforce Sensor Based on a Novel Bistable Bioinspired Swallow Structure for Somatic Cell Micromanipulation
Precise measurement of ultralow biaxial forces at the nano-Newton (nN) level is highly demanded for robotic micromanipulation of somatic cells. A novel microelectromechanical system capacitive nanoforce sensor was proposed to address this demand. Inspired by the stable gliding gestures of a swallow, a bistable swallow structure was introduced, offering high deformation flexibility with negligible mechanical cross-axis coupling. Considering its mechanical behaviors, a comb configuration and interconnection strategy were proposed to eliminate internal electrostatic coupling rotation. The fabricated sensor was packaged with a time-division multiplexing-based readout circuit, comprising a compact measurement system. The x-axis force sensitivity reached 0.9893 fF/nN, with a high resolution of 0.3658 nN and a linearity of 0.9994 over a range of 8.02 μN. Besides, the y-axis force sensitivity reached 0.2683 fF/nN, with a resolution of 0.8244 nN and a linearity of 0.9995 over a range of 8.11 μN. The noise floor was lower than 0.0665 nN/$\sqrt {\mathbf{Hz}} $ and 0.1688 nN/$\sqrt {\mathbf{Hz}} $ for x- and y-axes, respectively, and the cross-axis coupling error ratios were only 0.15% and 0.36%, respectively. The proposed sensor was adopted to manipulate mouse myoblast cells, allowing nN-level biaxial interaction force responses to be measured in real-time robotic manipulation for the first time.
- 10 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-13
An Inverse Capacitance Differential Equation-Based Six-Axis Force/Torque Sensor for the High-Accuracy Decoupling of Complex Multi-Axis Loads
Currently, space-variable, capacitive multi-axis force/torque sensors have limited detection accuracy in the measurement of complex multi-axis loads owing to their inherent nonlinearity and coupling errors in full range. The nonlinearity and coupling of the conventional capacitance differential equation were experimentally verified for a pre-developed space-variable capacitive six-axis force/torque sensing chip. An inverse capacitance differential decoupling equation was practically applied to the chip to suppress the inherent nonlinearity and coupling errors in full range (2.5 N and 12.5 N·mm) under multi-axis loads. The results of complex multi-axis coupled loading tests align with the theoretical analysis. When the inverse decoupling equation is adopted, the maximum nonlinearities of 18.59%FS (Full Scale) and coupling errors of 254.1%FS for the conventional equation can be reduced to 1.05%FS and 10.90%FS, respectively. The efficient decoupling structure combined with the inverse capacitance differential equation can provide critical theoretical guidance for developing high-accuracy capacitive multi-axis force/torque sensors.
- 10 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-13
An Inverse Capacitance Differential Equation-Based Six-Axis Force/Torque Sensor for the High-Accuracy Decoupling of Complex Multi-Axis Loads
Currently, space-variable, capacitive multi-axis force/torque sensors have limited detection accuracy in the measurement of complex multi-axis loads owing to their inherent nonlinearity and coupling errors in full range. The nonlinearity and coupling of the conventional capacitance differential equation were experimentally verified for a pre-developed space-variable capacitive six-axis force/torque sensing chip. An inverse capacitance differential decoupling equation was practically applied to the chip to suppress the inherent nonlinearity and coupling errors in full range (2.5 N and 12.5 N·mm) under multi-axis loads. The results of complex multi-axis coupled loading tests align with the theoretical analysis. When the inverse decoupling equation is adopted, the maximum nonlinearities of 18.59%FS (Full Scale) and coupling errors of 254.1%FS for the conventional equation can be reduced to 1.05%FS and 10.90%FS, respectively. The efficient decoupling structure combined with the inverse capacitance differential equation can provide critical theoretical guidance for developing high-accuracy capacitive multi-axis force/torque sensors.
- 4 October 2024
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 11 (4)
Intelligent sensing for the autonomous manipulation of microrobots toward minimally invasive cell surgery
The physiology and pathogenesis of biological cells have drawn enormous research interest. Benefiting from the rapid development of microfabrication and microelectronics, miniaturized robots with a tool size below micrometers have widely been studied for manipulating biological cells in vitro and in vivo. Traditionally, the complex physiological environment and biological fragility require human labor interference to fulfill these tasks, resulting in high risks of irreversible structural or functional damage and even clinical risk. Intelligent sensing devices and approaches have been recently integrated within robotic systems for environment visualization and interaction force control. As a consequence, microrobots can be autonomously manipulated with visual and interaction force feedback, greatly improving accuracy, efficiency, and damage regulation for minimally invasive cell surgery. This review first explores advanced tactile sensing in the aspects of sensing principles, design methodologies, and underlying physics. It also comprehensively discusses recent progress on visual sensing, where the imaging instruments and processing methods are summarized and analyzed. It then introduces autonomous micromanipulation practices utilizing visual and tactile sensing feedback and their corresponding applications in minimally invasive surgery. Finally, this work highlights and discusses the remaining challenges of current robotic micromanipulation and their future directions in clinical trials, providing valuable references about this field.
- 4 October 2024
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 11 (4)
Intelligent sensing for the autonomous manipulation of microrobots toward minimally invasive cell surgery
The physiology and pathogenesis of biological cells have drawn enormous research interest. Benefiting from the rapid development of microfabrication and microelectronics, miniaturized robots with a tool size below micrometers have widely been studied for manipulating biological cells in vitro and in vivo. Traditionally, the complex physiological environment and biological fragility require human labor interference to fulfill these tasks, resulting in high risks of irreversible structural or functional damage and even clinical risk. Intelligent sensing devices and approaches have been recently integrated within robotic systems for environment visualization and interaction force control. As a consequence, microrobots can be autonomously manipulated with visual and interaction force feedback, greatly improving accuracy, efficiency, and damage regulation for minimally invasive cell surgery. This review first explores advanced tactile sensing in the aspects of sensing principles, design methodologies, and underlying physics. It also comprehensively discusses recent progress on visual sensing, where the imaging instruments and processing methods are summarized and analyzed. It then introduces autonomous micromanipulation practices utilizing visual and tactile sensing feedback and their corresponding applications in minimally invasive surgery. Finally, this work highlights and discusses the remaining challenges of current robotic micromanipulation and their future directions in clinical trials, providing valuable references about this field.
- 12 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (7) , 7467-7477
A High-Resolution MEMS Capacitive Force Sensor With Bionic Swallow Comb Arrays for Ultralow Multiphysics Measurement
Precise force sensing is essential for the mechanical characterization and robotic micromanipulation of biological targets. In this work, a high-resolution microelectromechanical system capacitive force sensor is proposed for measuring ultralow multiphysics. A bionic swallow structure that contained multiple feathered comb arrays is designed for reducing chip dimension and eliminating undesirable mechanical cross-coupling effect. The comb structure is optimized for maximum sensitivity, linearity, and compact chip size. Utilizing a novel interconnection configuration, interferences derived from parasitic capacitance and electrostatic forces exerted negligible effects on the sensor output. The proposed bionic force sensor is fabricated following a simple three-mask process and integrated with application-specific integrated circuit readouts. Its measuring sensitivity is 7.151 fF/nm, 0.529 aF/nN, and 4.247 pF/g for displacement, force, and inclination measurements, respectively. The proposed sensor has a large measurement range of 1000.00 nm and 13.83 μN with a high linearity of 0.9998. The 1-σ resolution is 0.0328 nm and 0.4436 nN, and the noise floor resolution is 0.0044 nm $\sqrt {\mathbf{Hz}} $ and 0.0597 nN/ $\sqrt {\mathbf{Hz}} $ for displacement and force measurements, respectively. The bias stability of Allan deviance is 0.0050 nm and 0.0678 nN at an integration time of 0.65 s. The proposed bionic swallow sensor exhibits considerable improvement over existing capacitive sensors and feasibility for ultralow multiphysics measurement in biomedical applications.
- 12 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (7) , 7467-7477
A High-Resolution MEMS Capacitive Force Sensor With Bionic Swallow Comb Arrays for Ultralow Multiphysics Measurement
Precise force sensing is essential for the mechanical characterization and robotic micromanipulation of biological targets. In this work, a high-resolution microelectromechanical system capacitive force sensor is proposed for measuring ultralow multiphysics. A bionic swallow structure that contained multiple feathered comb arrays is designed for reducing chip dimension and eliminating undesirable mechanical cross-coupling effect. The comb structure is optimized for maximum sensitivity, linearity, and compact chip size. Utilizing a novel interconnection configuration, interferences derived from parasitic capacitance and electrostatic forces exerted negligible effects on the sensor output. The proposed bionic force sensor is fabricated following a simple three-mask process and integrated with application-specific integrated circuit readouts. Its measuring sensitivity is 7.151 fF/nm, 0.529 aF/nN, and 4.247 pF/g for displacement, force, and inclination measurements, respectively. The proposed sensor has a large measurement range of 1000.00 nm and 13.83 μN with a high linearity of 0.9998. The 1-σ resolution is 0.0328 nm and 0.4436 nN, and the noise floor resolution is 0.0044 nm $\sqrt {\mathbf{Hz}} $ and 0.0597 nN/ $\sqrt {\mathbf{Hz}} $ for displacement and force measurements, respectively. The bias stability of Allan deviance is 0.0050 nm and 0.0678 nN at an integration time of 0.65 s. The proposed bionic swallow sensor exhibits considerable improvement over existing capacitive sensors and feasibility for ultralow multiphysics measurement in biomedical applications.
- Open Access
- 31 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
An Area-variant Type MEMS Capacitive Sensor Based on A Novel Bionic Swallow Structure for High Sensitive Nano-indentation Measurement
In this paper, a high sensitive area-variant type MEMS capacitive sensor was proposed for nano-indentation measurement. The proposed bionic swallow structure processed a high mechanical sensitivity without influences from the load coupling effect. Six comb arrays were optimized and integrated into the proposed sensor with a novel comb sensing configuration for eliminating electrostatic interferences resulting from multiple combs and maintaining compact chip size. Based on the proposed micro-machined process, comb arrays have been fabricated with great consistency, which exhibited a static differential output of 0.0554 pF. The fabricated sensor has been characterized with rigid glass cube and AFM cantilevers, and the measured force sensitivity can reach 98.54 aF/nN for a larger measurement range of 142 µN with a linearity of 0.9996. The fabricated sensor also exhibited a high resolution of 0.9819 nN, indicating its great feasibility in nano-indentation measurement at the sub-nano-Newton level.
- 31 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessAn Area-variant Type MEMS Capacitive Sensor Based on A Novel Bionic Swallow Structure for High Sensitive Nano-indentation Measurement
In this paper, a high sensitive area-variant type MEMS capacitive sensor was proposed for nano-indentation measurement. The proposed bionic swallow structure processed a high mechanical sensitivity without influences from the load coupling effect. Six comb arrays were optimized and integrated into the proposed sensor with a novel comb sensing configuration for eliminating electrostatic interferences resulting from multiple combs and maintaining compact chip size. Based on the proposed micro-machined process, comb arrays have been fabricated with great consistency, which exhibited a static differential output of 0.0554 pF. The fabricated sensor has been characterized with rigid glass cube and AFM cantilevers, and the measured force sensitivity can reach 98.54 aF/nN for a larger measurement range of 142 µN with a linearity of 0.9996. The fabricated sensor also exhibited a high resolution of 0.9819 nN, indicating its great feasibility in nano-indentation measurement at the sub-nano-Newton level.