Abstract
Peg-in-hole (PIH) assembly of micropipettes to micro-electromechanical system (MEMS) nanoforce sensors can be performed to improve spatial probing resolution and operation space, but their spatial attitude angle deviations and off-axial distances lead to unstable assembly, sensor performance deterioration, and even structural damage. In this article, an automated and near-flawless micropipette PIH assembly method was proposed based on the built robotic microscopy system, to the best of our knowledge, for the first time. Utilizing an ISPR-based method with a mechanical equilibrium model and a sliding mode controller, the planar deflection angle was adjusted below 0.07 ${}^{\boldsymbol{\circ}}$ without being pushed out of FOV. The out-of-plane inclination angle was then reduced to below 0.05 ${}^{\boldsymbol{\circ}}$ by the proposed GTC-based method, whose depth is obtained from a feasible FDTBR inclination metrology and mechanical contact model. The off-axial distance was actively adjusted by an AIHM-based recenter method during sensor probe insertion, leading to a high assembly successful rate of 100% with negligible contact forces of 1.64 ${\boldsymbol{\mu}}$ N. The methodology effectiveness was validated through calibration tests, wherein no structural damage and performance deterioration were produced on the processed sensor for a long-term usage, indicating its great potential in nanoforce measurement.