JLJohn G. Linn

John G. Linn

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


John G. Linn has a total of 61 co-authors. Here are the top co-authors by number of shared publications:

  • Woody Denham

    NorthShore University HealthSystem, Evanston, USA

    11 shared publications
  • Michael Ujiki

    NorthShore University HealthSystem, Evanston, USA

    10 shared publications
  • JoAnn Carbray

    NorthShore University HealthSystem, Evanston, USA

    8 shared publications
  • Michael B. Ujiki

    Section of Minimally Invasive Surgery, Department of Surgery, NorthShore Center for Simulation and Innovation, NorthShore University HealthSystem, 2650 Ridge Ave, Evanston, IL, 60201, USA

    5 shared publications
  • Amy K. Yetasook

    4 shared publications
  • Brandon Johnson

    Section of Minimally Invasive Surgery, Department of Surgery, NorthShore Center for Simulation and Innovation, NorthShore University HealthSystem, 2650 Ridge Ave, Evanston, IL, 60201, USA

    4 shared publications

Latest Publications

  • Open Access

    Ventral Hernia Repair With a Hybrid Absorbable-permanent Preperitoneal Mesh

    by Matthew I. Goldblatt, Matthew Reynolds, Carl R. Doerhoff, Karl LeBlanc, Mario Leyba, Eric J. Mallico, John G. Linn

    Objective: To analyze device safety and clinical outcomes of ventral hernia repair with the GORE SYNECOR Preperitoneal Biomaterial (PRE device), a permanent high-strength mesh with bioabsorbable web scaffold technology. Materials and Methods: This multicenter retrospective review analyzed device/procedure endpoints and patient-reported outcomes in patients treated for hernia repair ≥1 year from study enrollment. Results: Included in this analysis were 148 patients with a mean age of 56 years; 66.2% met the Ventral Hernia Working Group grade 2 classification. Median hernia size was 30.0 cm2 and 58.8% of patients had an incisional hernia. Repairs were primarily a robotic (53.4%) or open approach (41.9%). All meshes were placed extraperitoneal. Procedure-related adverse events within 30 days occurred in 13 (8.8%) patients and included 7 (4.8%) patients with surgical site infection, 2 (1.4%) with surgical site occurrence (SSO), 4 (2.7%) requiring readmission, and 3 (2.0%) who had reoperation. The rate of SSO events requiring procedural intervention was 2.7% (4 patients) through 30 days and 3.4% (5 patients) at 12 months. The rate of procedure-related surgical site infection remained at 4.8% through 12 months (no further reports after 30 d) and 3.4% for SSO (2 reports after 30 d). There were no site-reported clinically diagnosed hernia recurrences throughout the study. Median patient follow-up including in-person visit, physical examination, reported adverse event, explant, death, and questionnaire response was 28 months (n = 148). Median patient follow-up with patient questionnaire was 36 months (n = 88). Conclusions: Use of the PRE device, which incorporates the proven advantages of both an absorbable synthetic mesh and the long-term durability of a permanent macroporous mesh, is safe and effective in complex ventral hernia repairs. When used in the retromuscular space, the combination of these 2 materials had lower wound complications and recurrence rates than either type of material alone.


  • Open Access

    Correction: Evaluation of long-term performance of an intraperitoneal biomaterial in the treatment of ventral hernias

    by John G. Linn, Eric J. Mallico, Carl R. Doerhoff, David W. Grantham, Raymond G. Washington


  • Open Access

    Correction: Evaluation of long-term performance of an intraperitoneal biomaterial in the treatment of ventral hernias

    by John G. Linn, Eric J. Mallico, Carl R. Doerhoff, David W. Grantham, Raymond G. Washington


  • Open Access

    Evaluation of Long-term Performance of the GORE SYNECOR Intraperitoneal Biomaterial in the Treatment of Inguinal Hernias

    by David W. Md Grantham, Carl R. Doerhoff, John G. Linn, Eric J. Mallico, Raymond G. Jr Md Washington

    Background: The objective of this study was to analyze device safety and clinical outcomes of inguinal hernia repair with the GORE SYNECOR Intraperitoneal Biomaterial device, a hybrid composite mesh. Methods: This retrospective case review analyzed device/procedure endpoints beyond 1 year in patients treated for inguinal hernia repair with the device. Three objectives were evaluated: procedural endpoint—incidence through 30 days of surgical site infection, surgical site occurrence (SSO), ileus, readmission, reoperation, and death; device endpoint—serious device incidence of mesh erosion, infection, excision/removal, exposure, migration, shrinkage, device-related bowel obstruction and fistula, and hernia recurrence through 12 months; and patient-reported outcomes of the bulge, physical symptoms, and pain. Results: A total of 157 patients (mean age: 67±13 y) with 201 inguinal hernias (mean size: 5.1±5 cm2) were included. Laparoscopic approach and bridging repair were performed in 99.4% of patients. All device location was preperitoneal. No procedure-related adverse events within 30 days were reported. No surgical site infection or SSO events or device-related hernia recurrence occurred through 12 months. Procedure-related serious adverse events occurred in 6 patients; 5 recurrent inguinal hernias (at 1 and 2 y) and 1 scrotal hematoma (at 6 mo). Through 24 months, no SSO events requiring procedural intervention occurred. Through 50 months, 6 (2.98%) patients had confirmed hernia recurrence and 4 (1.99%) patients had hernia reoperation. The patient-reported outcome for pain was reported by 7.9% (10/126) of patients who completed the questionnaire. Conclusions: In this study, inguinal hernia repair with the hybrid composite mesh was successful in most patients and the rate of recurrence was low, further supporting the long-term safety and device performance.


  • Open Access

    Evaluation of long-term performance of an intraperitoneal biomaterial in the treatment of ventral hernias

    by John G. Linn, Eric J. Mallico, Carl R. Doerhoff, David W. Grantham, Raymond G. Washington

    Background: One-year device safety and clinical outcomes of ventral hernia repair with the GORE® SYNECOR Intraperitoneal Biomaterial, a hybrid composite mesh was evaluated. Methods: This retrospective, multicenter, case review analyzed device/procedure endpoints and patient-reported outcomes in patients treated for hernia repair ≥ 1 year from study enrollment. Results: Included were 459 patients (with 469 ventral hernias) with a mean age of 58 ± 15 years; 77.1% met Ventral Hernia Working Group 2 (VHWG2) classification. Mean hernia size was 18.9 cm2 and 57.3% of hernias were incisional. Laparoscopic or robotic approach was utilized in 95.4% of patients. Mesh location was intraperitoneal for 75.6% and bridging repair was performed in 57.3%. Procedure-related adverse events within 30-days occurred in 5.0% of patients and included surgical site infection (SSI), surgical site occurrence (SSO), ileus, readmission, and re-operation. Procedure-related SSI or SSO events were 3.8% through 12 months. SSO events requiring procedural intervention (SSOPI) were 2.6% through 24 months. Four patients (0.9%) had confirmed hernia recurrence through the study (the mean follow-up was 32-months, range 14–53 months). Subgroup comparisons were conducted for all type recurrence; only diabetes was found to be statistically significant (p = .0506). Conclusion: In this analysis, ventral hernia repair with hybrid, composite mesh results in successful outcomes in most patients. This study represents a heterogeneous patient population undergoing repair using various approaches, mesh fixation, and mesh placement locations. These data appear to confirm long-term acceptable safety and device performance with a low rate of recurrence in a predominantly VHWG2 population.


  • Short-term quality of life comparison of laparoscopic, open, and robotic incisional hernia repairs

    by Beau Forester, Mikhail Attaar, Kara Donovan, Kristine Kuchta, Michael Ujiki, Woody Denham, Stephen P. Haggerty, JoAnn Carbray, John Linn

    Background Outcomes of incisional hernia repair (IHR) include recurrence and quality of life (QOL). Operative approaches include laparoscopic, open, and robotic approaches. Data regarding comparative QOL outcomes among these repair types are unknown. Our study evaluates quality of life after three approaches to IHR. Study design Patients undergoing open (OHR), laparoscopic (LIHR), and robotic extra-peritoneal (RIHR) at a single institution from 2009 to 2019 were reviewed from a prospectively managed quality database. Short-term QOL was compared among the three procedures using the Surgical Outcomes Measurement System (SOMS) and Carolinas Comfort Scale (CCS), objective pain scores and postoperative narcotic use. Data regarding length of stay (LOS), emergency department (ED) visits, readmission, reoperations and surgical site infection (SSI) were also collected. Results A total of 795 patients undergoing IHR were analyzed (418 open, 300 laparoscopic and 77 robotic). Patient were similar in age, gender and co-morbidities. LIHR patients had higher BMI and RIHR patients had larger hernia and mesh size. LOS was longer and rate of SSI was higher for OIHR compared to laparoscopic and RIHR. Patients undergoing LIHR reported increased narcotic use, Visual Analogue Scale (VAS) and CCS pain scores compared to open and robotic repair. Return to daily activity was 4 days shorter for robotic than open and laparoscopic repair; ED visits, readmissions, reoperations, and other QOL domains were similar. Conclusion Our data suggests that short-term quality of life after robotic extra-peritoneal IHR is improved compared to open and laparoscopic repair. Additional follow up is required to determine differences in long-term QOL after IHR.


  • An analysis of results in a single-blinded, prospective randomized controlled trial comparing non-fixating versus self-fixating mesh for laparoscopic inguinal hernia repair

    by Merritt Denham, Brandon Johnson, Michelle Leong, Kristine Kuchta, Eliza Conaty, Michael B. Ujiki, Woody Denham, Stephen P. Haggerty, Zeeshan Butt, JoAnn Carbray, et al.

    It remains unclear whether use of self-fixating mesh during laparoscopic inguinal hernia repair (LIHR) impacts postoperative quality of life (QoL). We hypothesize patients receiving self-fixating mesh during totally extraperitoneal (TEP) LIHR will report less pain and improved QoL compared to those receiving non-fixating mesh.


  • Su1305 - Outcomes of Ventral Hernia Repair with Intraperitoneal Mesh in Patients with Crohn's Disease

    by Kara Donovan, Merritt Denham, Michelle Leong, Kristine Kuchta, JoAnn Carbray, Woody Denham, Stephen P. Haggerty, John G. Linn, Michael Ujiki

  • Predicting Progression in Barrett's Esophagus

    by Craig S. Brown, Brittany Lapin, Jay L. Goldstein, John G. Linn, Mark S. Talamonti, Joann Carbray, Michael B. Ujiki

    To develop and validate a scoring tool capable of accurately predicting which patients with Barrett's esophagus (BE) will progress to dysplasia and/or esophageal adenocarcinoma. Endoscopic therapies have emerged capable of eradicating BE with high efficacy and low complication rates, but which patients should receive treatment is still debated. Current knowledge of risk factors is insufficient to allow for the accurate prediction of which patients will progress to dysplasia or adenocarcinoma. We retrospectively collected data from a cohort of BE patients over a 13-year period. A multivariable logistic regression model was constructed to predict progression. A simplified risk of progression (ROP) score was developed from weighted beta coefficients. Internal validation was performed using bootstrap analysis, and model discrimination was assessed using k-fold cross-validation. The cohort included 2591 BE patients of which 133 progressed to dysplasia/adenocarcinoma. Multivariable analysis with bootstrap internal validation resulted in 5 variables associated with an increased ROP (age ≥70 years, male sex, lack of proton-pump inhibitor use, segment greater than 3 cm, and history of esophageal candidiasis). Using this model, we developed a simple ROP score between 0 and 8. Receiver operating characteristic analysis showed a cutoff of 3 or higher to have a sensitivity and specificity of 70% and 79%, respectively. Patients with a score of 3 or higher had an odds ratio of 9.04 (95% confidence interval 6.06–13.46). The c-statistic obtained from 10-fold cross-validation was 0.76 (95% confidence interval 0.72–0.79), indicating good overall discrimination. Our data show the development and internal validation of the Barrett's Esophagus Assessment of Risk Score as capable of quantifying the likelihood of progression to dysplasia/adenocarcinoma. The Barrett's Esophagus Assessment of Risk Score can be used clinically to guide treatment decisions in nondysplastic BE patients.


  • Endoscopic Gastrojejunal Revision Results in More Weight Loss Than Medical Management Alone for Weight Regain after Gastric Bypass

    by Herbert M. Hedberg, Alexander Trenk, Eliza Conaty, John G. Linn, Joann Carbray, Michael Ujiki