P. Morten Hundt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
P. Morten Hundt has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Béla Tuzson
Empa, Laboratory for Air Pollution/Environmental Technology, Dübendorf, Switzerland
3 shared publications Herbert Looser
Empa-Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Air Pollution and Environmental Technology
3 shared publications- Lukas Emmenegger
Empa, Laboratory for Air Pollution/Environmental Technology, Dübendorf, Switzerland
3 shared publications Philipp Scheidegger
Empa-Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Air Pollution and Environmental Technology
3 shared publications- Christoph Hueglin
Empa, Laboratory for Air Pollution/Environmental Technology, Dübendorf, Switzerland
2 shared publications Markus Mangold
Laboratory for Air Pollution and Environmental Technology, Empa, 8600 Dübendorf, Switzerland
2 shared publications
Latest Publications
- 17 May 2018
- Published by Springer Nature in Applied Physics B
- Vol. 124 (6) , 108
Multi-species trace gas sensing with dual-wavelength QCLs
- 17 May 2018
- Published by Springer Nature in Applied Physics B
- Vol. 124 (6) , 108
Multi-species trace gas sensing with dual-wavelength QCLs
- Open Access
- 7 May 2018
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 11 (5) , 2669-2681
Mid-IR spectrometer for mobile, real-time urban NO2 measurements
Detailed knowledge about the urban NO2 concentration field is a key element for obtaining accurate pollution maps and individual exposure estimates. These are required for improving the understanding of the impact of ambient NO2 on human health and for related air quality measures. However, city-scale NO2 concentration maps with high spatio-temporal resolution are still lacking, mainly due to the difficulty of accurate measurement of NO2 at the required sub-ppb level precision. We contribute to close this gap through the development of a compact instrument based on mid-infrared laser absorption spectroscopy. Leveraging recent advances in infrared laser and detection technology and a novel circular absorption cell, we demonstrate the feasibility and robustness of this technique for demanding mobile applications. A fully autonomous quantum cascade laser absorption spectrometer (QCLAS) has been successfully deployed on a tram, performing long-term and real-time concentration measurements of NO2 in the city of Zurich (Switzerland). For ambient NO2 concentrations, the instrument demonstrated a precision of 0.23 ppb at one second time resolution and of 0.03 ppb after 200 s averaging. Whilst the combined uncertainty estimated for the retrieved spectroscopic values was less than 5 %, laboratory intercomparison measurements with standard CLD instruments revealed a systematic NO2 wall loss of about 10 % within the laser spectrometer. For the field campaign, the QCLAS has been referenced to a CLD using urban atmospheric air, despite the potential cross sensitivity of CLD to other nitrogen containing compounds. However, this approach allowed a direct comparison and continuous validation of the spectroscopic data to measurements at regulatory air quality monitoring (AQM) stations along the tram-line. The analysis of the recorded high-resolution time series allowed us to gain more detailed insights into the spatio-temporal concentration distribution of NO2 in an urban environment. Furthermore, our results demonstrate that for reliable city-scale concentration maps a larger data set and better spatial coverage is needed, e.g., by deploying more mobile and stationary instruments to account for mainly two shortcomings of the current approach: (i) limited residence time close to sources with large short-term NO2 variations, and (ii) insufficient representativeness of the tram tracks for the complex urban environment.
- 7 May 2018
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 11 (5) , 2669-2681
Open AccessMid-IR spectrometer for mobile, real-time urban NO2 measurements
Detailed knowledge about the urban NO2 concentration field is a key element for obtaining accurate pollution maps and individual exposure estimates. These are required for improving the understanding of the impact of ambient NO2 on human health and for related air quality measures. However, city-scale NO2 concentration maps with high spatio-temporal resolution are still lacking, mainly due to the difficulty of accurate measurement of NO2 at the required sub-ppb level precision. We contribute to close this gap through the development of a compact instrument based on mid-infrared laser absorption spectroscopy. Leveraging recent advances in infrared laser and detection technology and a novel circular absorption cell, we demonstrate the feasibility and robustness of this technique for demanding mobile applications. A fully autonomous quantum cascade laser absorption spectrometer (QCLAS) has been successfully deployed on a tram, performing long-term and real-time concentration measurements of NO2 in the city of Zurich (Switzerland). For ambient NO2 concentrations, the instrument demonstrated a precision of 0.23 ppb at one second time resolution and of 0.03 ppb after 200 s averaging. Whilst the combined uncertainty estimated for the retrieved spectroscopic values was less than 5 %, laboratory intercomparison measurements with standard CLD instruments revealed a systematic NO2 wall loss of about 10 % within the laser spectrometer. For the field campaign, the QCLAS has been referenced to a CLD using urban atmospheric air, despite the potential cross sensitivity of CLD to other nitrogen containing compounds. However, this approach allowed a direct comparison and continuous validation of the spectroscopic data to measurements at regulatory air quality monitoring (AQM) stations along the tram-line. The analysis of the recorded high-resolution time series allowed us to gain more detailed insights into the spatio-temporal concentration distribution of NO2 in an urban environment. Furthermore, our results demonstrate that for reliable city-scale concentration maps a larger data set and better spatial coverage is needed, e.g., by deploying more mobile and stationary instruments to account for mainly two shortcomings of the current approach: (i) limited residence time close to sources with large short-term NO2 variations, and (ii) insufficient representativeness of the tram tracks for the complex urban environment.
- Open Access
- 31 March 2017
- Published by Copernicus GmbH in EGUsphere
- p. 1-21
Spectroscopic real-time monitoring of NO2 for city scale modelling
Detailed knowledge about the urban NO2 concentration field is a key element for obtaining accurate, individual exposure estimates. These are required for improving the understanding of the impact of ambient NO2 on human health and for related air quality measures. We developed a compact and robust quantum cascade laser absorption spectrometer (QCLAS) and deployed it on a tram in the city of Zurich (Switzerland) to perform mobile real-time concentration measurements of NO2. Thorough analysis of the obtained NO2 data, for instance by comparison with data from fixed air quality monitoring (AQM) sites, revealed the instrument to be highly accurate and valuable for collection of data that can be used in statistical models for the calculation of spatio-temporally resolved NO2 concentration maps. The combination of fast mobile measurements with AQM data proved to be very suitable, but the statistical data analysis also showed that a single mobile instrument is not sufficient in the studied urban area, for mainly two reasons: (i) short residence close to sources with large short-term NO2 variations and (ii) limited representativeness of the tram tracks for the entire urban environment.
- 31 March 2017
- Published by Copernicus GmbH in EGUsphere
- p. 1-21
Open AccessSpectroscopic real-time monitoring of NO2 for city scale modelling
Detailed knowledge about the urban NO2 concentration field is a key element for obtaining accurate, individual exposure estimates. These are required for improving the understanding of the impact of ambient NO2 on human health and for related air quality measures. We developed a compact and robust quantum cascade laser absorption spectrometer (QCLAS) and deployed it on a tram in the city of Zurich (Switzerland) to perform mobile real-time concentration measurements of NO2. Thorough analysis of the obtained NO2 data, for instance by comparison with data from fixed air quality monitoring (AQM) sites, revealed the instrument to be highly accurate and valuable for collection of data that can be used in statistical models for the calculation of spatio-temporally resolved NO2 concentration maps. The combination of fast mobile measurements with AQM data proved to be very suitable, but the statistical data analysis also showed that a single mobile instrument is not sufficient in the studied urban area, for mainly two reasons: (i) short residence close to sources with large short-term NO2 variations and (ii) limited representativeness of the tram tracks for the entire urban environment.
- Open Access
Dual-Section DFB-QCLs for Multi-Species Trace Gas Analysis
We report on the dynamic behavior of dual-wavelength distributed feedback (DFB) quantum cascade lasers (QCLs) in continuous wave and intermittent continuous wave operation. We investigate inherent etaloning effects based on spectrally resolved light-current-voltage (LIV) characterization and perform time-resolved spectral analysis of thermal chirping during long (>5 µs) current pulses. The theoretical aspects of the observed behavior are discussed using a combination of finite element method simulations and transfer matrix method calculations of dual-section DFB structures. Based on these results, we demonstrate how the internal etaloning can be minimized using anti-reflective (AR) coatings. Finally, the potential and benefits of these devices for high precision trace gas analysis are demonstrated using a laser absorption spectroscopic setup. Thereby, the atmospherically highly relevant compounds CO2 (including its major isotopologues), CO and N2O are simultaneously determined with a precision of 0.16 ppm, 0.22 ppb and 0.26 ppb, respectively, using a 1-s integration time and an optical path-length of 36 m. This creates exciting new opportunities in the development of compact, multi-species trace gas analyzers.
Open AccessDual-Section DFB-QCLs for Multi-Species Trace Gas Analysis
We report on the dynamic behavior of dual-wavelength distributed feedback (DFB) quantum cascade lasers (QCLs) in continuous wave and intermittent continuous wave operation. We investigate inherent etaloning effects based on spectrally resolved light-current-voltage (LIV) characterization and perform time-resolved spectral analysis of thermal chirping during long (>5 µs) current pulses. The theoretical aspects of the observed behavior are discussed using a combination of finite element method simulations and transfer matrix method calculations of dual-section DFB structures. Based on these results, we demonstrate how the internal etaloning can be minimized using anti-reflective (AR) coatings. Finally, the potential and benefits of these devices for high precision trace gas analysis are demonstrated using a laser absorption spectroscopic setup. Thereby, the atmospherically highly relevant compounds CO2 (including its major isotopologues), CO and N2O are simultaneously determined with a precision of 0.16 ppm, 0.22 ppb and 0.26 ppb, respectively, using a 1-s integration time and an optical path-length of 36 m. This creates exciting new opportunities in the development of compact, multi-species trace gas analyzers.