Mid-IR spectrometer for mobile, real-time urban NO2 measurements
Open Access
- 7 May 2018
- journal article
- research article
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 11 (5) , 2669-2681
Abstract
Detailed knowledge about the urban NO2 concentration field is a key element for obtaining accurate pollution maps and individual exposure estimates. These are required for improving the understanding of the impact of ambient NO2 on human health and for related air quality measures. However, city-scale NO2 concentration maps with high spatio-temporal resolution are still lacking, mainly due to the difficulty of accurate measurement of NO2 at the required sub-ppb level precision. We contribute to close this gap through the development of a compact instrument based on mid-infrared laser absorption spectroscopy. Leveraging recent advances in infrared laser and detection technology and a novel circular absorption cell, we demonstrate the feasibility and robustness of this technique for demanding mobile applications. A fully autonomous quantum cascade laser absorption spectrometer (QCLAS) has been successfully deployed on a tram, performing long-term and real-time concentration measurements of NO2 in the city of Zurich (Switzerland). For ambient NO2 concentrations, the instrument demonstrated a precision of 0.23 ppb at one second time resolution and of 0.03 ppb after 200 s averaging. Whilst the combined uncertainty estimated for the retrieved spectroscopic values was less than 5 %, laboratory intercomparison measurements with standard CLD instruments revealed a systematic NO2 wall loss of about 10 % within the laser spectrometer. For the field campaign, the QCLAS has been referenced to a CLD using urban atmospheric air, despite the potential cross sensitivity of CLD to other nitrogen containing compounds. However, this approach allowed a direct comparison and continuous validation of the spectroscopic data to measurements at regulatory air quality monitoring (AQM) stations along the tram-line. The analysis of the recorded high-resolution time series allowed us to gain more detailed insights into the spatio-temporal concentration distribution of NO2 in an urban environment. Furthermore, our results demonstrate that for reliable city-scale concentration maps a larger data set and better spatial coverage is needed, e.g., by deploying more mobile and stationary instruments to account for mainly two shortcomings of the current approach: (i) limited residence time close to sources with large short-term NO2 variations, and (ii) insufficient representativeness of the tram tracks for the complex urban environment.Keywords
All Related Versions
This publication has 39 references indexed in Scilit:
- The use of electrochemical sensors for monitoring urban air quality in low-cost, high-density networksAtmospheric Environment, 2013
- Development of a new Long Path Absorption Photometer (LOPAP) instrument for the sensitive detection of NO2 in the atmosphereAtmospheric Measurement Techniques, 2011
- The development of a nitrogen dioxide sondeAtmospheric Measurement Techniques, 2010
- A Sensitive and Versatile Detector for Atmospheric NO2 and NOX Based on Blue Diode Laser Cavity Ring-Down SpectroscopyEnvironmental Science & Technology, 2009
- Laser induced fluorescence instrument for NO2 measurements: Observations at a central Italy background siteAtmospheric Environment, 2009
- A Cohort Study of Traffic-Related Air Pollution Impacts on Birth OutcomesEnvironmental Health Perspectives, 2008
- Evaluation of nitrogen dioxide chemiluminescence monitors in a polluted urban environmentAtmospheric Chemistry and Physics, 2007
- Sub-parts-per-billion level detection of NO2using room-temperature quantum cascade lasersProceedings of the National Academy of Sciences, 2006
- Detection of Nitrogen Dioxide by Cavity Attenuated Phase Shift SpectroscopyAnalytical Chemistry, 2004
- The ν1, 2ν2, and ν3 interacting bands of 14N16O2: Line positions and intensitiesJournal of Molecular Spectroscopy, 1992