Darliana Mello Souza
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Darliana Mello Souza has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Jussiane Souza Silva
Federal University of Santa Maria
3 shared publications Leandro Michels
Federal University of Santa Maria
3 shared publications- Luana Formagini
Department of Chemistry
3 shared publications Adriano Marques Jaime
Federal University of Santa Maria
2 shared publications- Ayrton Figueiredo Martins
Chemistry Department, Federal University of Santa Maria, RS, Brazil
2 shared publications - Charles Andre Haab
Federal University of Santa Maria
2 shared publications
Latest Publications
- Open Access
- 2 November 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (45) , 70465-70474
Signal-Analytics Modeling of Fluorescence Maximum Time-to-Detection (TTD+) for E. coli in Treated Wastewater: A Joint Censoring and Sensor Model Approach Part II
Water security is a global priority and relies on reliable microbiological monitoring in treated effluents. In this work, we investigate a sensor-analytics component of Escherichia coli (E. coli) monitoring in treated wastewater through fluorescence time courses acquired with a miniaturized, Internet of Things-enabled incubation platform, named the Optical Bacterial Growth Sensor–Fluorescence Detector. The signal arises from hydrolysis of a β-d-glucuronide substrate mediated by E. coli-expressed β-glucuronidase activity, yielding characteristic kinetic profiles over time. Our primary target is the extraction and probabilistic modeling of the upper time-to-detection, TTD+, an operational timing feature of the recorded fluorescence response. In practical terms, TTD+ retrospectively identifies the onset of the upper stable signal region under the adopted criterion, providing a timing summary for assay duration planning. To model this time-domain boundary, we adopt the Joint Censoring and Sensor Model Approach (JCSMA) and further extend it by deriving analytical expressions for ordinary moments and entropy measures, including Rényi and Shannon entropies. The empirical comparison favors JCSMA within the evaluated model set, while simulation characterizes the sampling behavior of selected statistics under the fitted model. The resulting probabilities and quantiles provide summaries for assay duration planning under the adopted conditions. The study does not evaluate analytical figures of merit for E. coli quantification or the association between TTD+ and reference most probable number values.
- 2 November 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (45) , 70465-70474
Open AccessSignal-Analytics Modeling of Fluorescence Maximum Time-to-Detection (TTD+) for E. coli in Treated Wastewater: A Joint Censoring and Sensor Model Approach Part II
Water security is a global priority and relies on reliable microbiological monitoring in treated effluents. In this work, we investigate a sensor-analytics component of Escherichia coli (E. coli) monitoring in treated wastewater through fluorescence time courses acquired with a miniaturized, Internet of Things-enabled incubation platform, named the Optical Bacterial Growth Sensor–Fluorescence Detector. The signal arises from hydrolysis of a β-d-glucuronide substrate mediated by E. coli-expressed β-glucuronidase activity, yielding characteristic kinetic profiles over time. Our primary target is the extraction and probabilistic modeling of the upper time-to-detection, TTD+, an operational timing feature of the recorded fluorescence response. In practical terms, TTD+ retrospectively identifies the onset of the upper stable signal region under the adopted criterion, providing a timing summary for assay duration planning. To model this time-domain boundary, we adopt the Joint Censoring and Sensor Model Approach (JCSMA) and further extend it by deriving analytical expressions for ordinary moments and entropy measures, including Rényi and Shannon entropies. The empirical comparison favors JCSMA within the evaluated model set, while simulation characterizes the sampling behavior of selected statistics under the fitted model. The resulting probabilities and quantiles provide summaries for assay duration planning under the adopted conditions. The study does not evaluate analytical figures of merit for E. coli quantification or the association between TTD+ and reference most probable number values.
- Open Access
- 2 July 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (28) , 41534-41542
Signal-Analytics Modeling of Fluorescence Time-to-Detection for E. coli in Treated Wastewater: A Joint Censoring and Sensor Model Approach
- 2 July 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (28) , 41534-41542
Open AccessSignal-Analytics Modeling of Fluorescence Time-to-Detection for E. coli in Treated Wastewater: A Joint Censoring and Sensor Model Approach
- Open Access
- 27 February 2026
- Published by Elsevier in SSRN Electronic Journal
Voltammetric Determination of Mirtazapine in Water and Domestic Effluents Using Screen-Printed Electrodes
This work focuses on the development of a simple and sensitive voltammetric method for the antidepressant mirtazapine (MIR) determination in aqueous environmental samples by using carbon screen printed electrodes (SPE). Electrochemical characteristics of MIR were evaluated by cyclic voltammetry (CV). The results indicate an irreversible oxidation process controlled by diffusion, involving a ratio of 1:1 of electrons and protons exchange. Differential pulse voltammetry (DPV) and square wave voltammetry (SWV) were used for MIR quantification. Phosphate, Tris-HCl and BR buffers were evaluated in order to establish the best supporting electrolyte, where the good analytical performance was achieved by DPV using BR 0.1 mol L-1 at pH 7.0. The method showed good linearity in the concentration range of 0.94 to 28.76 μmol L-1 MIR, with good repeatability (RSD less than 10%), sensitivity, accuracy and robustness. Limits of detection and quantification were 0.22 and 0.67 μmol L-1, respectively. The method was applied for MIR determination in drinking water, surface water and domestic effluent. Samples were only filtered before analysis. MIR was not detected. Analyte recovery and comparison of the results with UV spectrophotometry were used to check interferences and accuracy of the method. Analyte recovery is in the range of 99% to 106%, and good agreement of the results from UV was achieved. The work shows the viability of using carbon SPEs as a rapid analytical method for emerging contaminant determination with minimal sample treatment, turning the method useful for in field application.
- 27 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessVoltammetric Determination of Mirtazapine in Water and Domestic Effluents Using Screen-Printed Electrodes
This work focuses on the development of a simple and sensitive voltammetric method for the antidepressant mirtazapine (MIR) determination in aqueous environmental samples by using carbon screen printed electrodes (SPE). Electrochemical characteristics of MIR were evaluated by cyclic voltammetry (CV). The results indicate an irreversible oxidation process controlled by diffusion, involving a ratio of 1:1 of electrons and protons exchange. Differential pulse voltammetry (DPV) and square wave voltammetry (SWV) were used for MIR quantification. Phosphate, Tris-HCl and BR buffers were evaluated in order to establish the best supporting electrolyte, where the good analytical performance was achieved by DPV using BR 0.1 mol L-1 at pH 7.0. The method showed good linearity in the concentration range of 0.94 to 28.76 μmol L-1 MIR, with good repeatability (RSD less than 10%), sensitivity, accuracy and robustness. Limits of detection and quantification were 0.22 and 0.67 μmol L-1, respectively. The method was applied for MIR determination in drinking water, surface water and domestic effluent. Samples were only filtered before analysis. MIR was not detected. Analyte recovery and comparison of the results with UV spectrophotometry were used to check interferences and accuracy of the method. Analyte recovery is in the range of 99% to 106%, and good agreement of the results from UV was achieved. The work shows the viability of using carbon SPEs as a rapid analytical method for emerging contaminant determination with minimal sample treatment, turning the method useful for in field application.
- Open Access
- 16 February 2026
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 6 (3) , 1360-1376
Advanced Oxidation Processes for the Removal of Selected Antidepressants and Anxiolytics from Aqueous Matrixes: Current Status, Knowledge Gaps, and Future Perspectives
- 16 February 2026
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 6 (3) , 1360-1376
Open AccessAdvanced Oxidation Processes for the Removal of Selected Antidepressants and Anxiolytics from Aqueous Matrixes: Current Status, Knowledge Gaps, and Future Perspectives
- Open Access
- 30 October 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (44) , 24438-24448
Feasibility for Real-Time Monitoring of Bacterial Growth in Raw Milk Using a New Contactless Sensor
A novel method was developed for real-time quantification of the total bacterial count in raw milk using an electrical bacterial growth sensor based on a capacitively coupled contactless resonance frequency detector. The proposed method continuously monitors changes in the resonance frequency induced by bacterial metabolic activity, allowing for the construction of growth curves without requiring sample pretreatment or reagent addition. Growth curve analysis was performed using the Gompertz model, and the inflection point (β) was used to construct a predictive model for determining the total bacterial count. A total of 55 raw milk samples were used for the predictive model and application of the proposed method, which were compared to the standard plate count reference method. The predictive model demonstrated a good coefficient of determination (R2 = 0.75). A comparative analysis between the proposed and reference methods showed no significant difference (t-test, 95% confidence level). The proposed method presented a limit of detection of 2.40 log CFU mL-1. The results also demonstrate that the proposed method presents a higher greenness score (score = 0.75) compared to the reference method (score = 0.39) and that the analysis time could be reduced from 48 to 8 h to classify the raw milk according to Normative Instruction No. 55/2020. These findings highlight the feasibility of the proposed method for rapid, green, and real-time monitoring of bacterial growth, allowing a promising alternative to microbiological quality control in the dairy industry.
- 30 October 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (44) , 24438-24448
Open AccessFeasibility for Real-Time Monitoring of Bacterial Growth in Raw Milk Using a New Contactless Sensor
A novel method was developed for real-time quantification of the total bacterial count in raw milk using an electrical bacterial growth sensor based on a capacitively coupled contactless resonance frequency detector. The proposed method continuously monitors changes in the resonance frequency induced by bacterial metabolic activity, allowing for the construction of growth curves without requiring sample pretreatment or reagent addition. Growth curve analysis was performed using the Gompertz model, and the inflection point (β) was used to construct a predictive model for determining the total bacterial count. A total of 55 raw milk samples were used for the predictive model and application of the proposed method, which were compared to the standard plate count reference method. The predictive model demonstrated a good coefficient of determination (R2 = 0.75). A comparative analysis between the proposed and reference methods showed no significant difference (t-test, 95% confidence level). The proposed method presented a limit of detection of 2.40 log CFU mL-1. The results also demonstrate that the proposed method presents a higher greenness score (score = 0.75) compared to the reference method (score = 0.39) and that the analysis time could be reduced from 48 to 8 h to classify the raw milk according to Normative Instruction No. 55/2020. These findings highlight the feasibility of the proposed method for rapid, green, and real-time monitoring of bacterial growth, allowing a promising alternative to microbiological quality control in the dairy industry.
- 23 August 2025
- Published by Elsevier in Science of The Total Environment
- Vol. 998, 180269
Psychotropic pharmaceuticals in aquatic environments: Occurrence and analytical challenges
- 23 August 2025
- Published by Elsevier in Science of The Total Environment
- Vol. 998, 180269
Psychotropic pharmaceuticals in aquatic environments: Occurrence and analytical challenges
- 10 January 2025
- Published by Brazilian Journal of Analytical Chemistry in Brazilian Journal of Analytical Chemistry
Anticancer Drug Docetaxel in Hospital Effluent: Development of Chromatographic Method, Occurrence, and Degradation via Ozonation
Anticancer agents, specifically designed to induce cell death in neoplastic cells, have become increasingly prevalent contaminants in various environmental matrices. Their extensive use has resulted in their detection across multiple settings, including hospital and pharmaceutical factory effluents, domestic wastewater, and surface waters. This study aimed to develop an analytical method for determining docetaxel residues in hospital effluent using Solid-Phase Extraction (SPE) and HPLC-DAD. The SPE method demonstrated R² greater than 0.99, with recovery rates reaching 95% and an RSD of less than 2%. The LOQ was established at 10.0 μg L−1, with no significant matrix effects observed for docetaxel. The validated SPE method was deemed suitable for its intended application, as all evaluated parameters met the specifications outlined in current regulatory guidelines. Docetaxel was quantified at 29.9 μg L−1 (±1.3%) in one of the 14 effluent samples collected over a week from the Federal University of Santa Maria Hospital (HUSM). Given that the microbiological treatment system at HUSM does not effectively remove this drug, an advanced degradation process using ozonation was investigated. A Dispersive Liquid-Liquid Microextraction (DLLME) method was developed for bench-scale degradation studies and subsequently applied to assess the degradation of docetaxel via ozonation in real samples. The optimized extraction conditions for docetaxel involved a 10 mL hospital effluent sample at pH 9, with ionic strength adjusted using Na₂SO₄. Methanol served as the disperser solvent, while chloroform was the extracting solvent. The ozonation process achieved a removal efficiency exceeding 97% after 60 minutes of reaction, under optimal conditions of pH 7 and an average ozone production rate of 1.5 g O₃ h⁻¹. These findings indicate that ozonation is an effective treatment strategy, significantly reducing docetaxel concentrations in hospital effluent within a short reaction timeframe.
- 10 January 2025
- Published by Brazilian Journal of Analytical Chemistry in Brazilian Journal of Analytical Chemistry
Anticancer Drug Docetaxel in Hospital Effluent: Development of Chromatographic Method, Occurrence, and Degradation via Ozonation
Anticancer agents, specifically designed to induce cell death in neoplastic cells, have become increasingly prevalent contaminants in various environmental matrices. Their extensive use has resulted in their detection across multiple settings, including hospital and pharmaceutical factory effluents, domestic wastewater, and surface waters. This study aimed to develop an analytical method for determining docetaxel residues in hospital effluent using Solid-Phase Extraction (SPE) and HPLC-DAD. The SPE method demonstrated R² greater than 0.99, with recovery rates reaching 95% and an RSD of less than 2%. The LOQ was established at 10.0 μg L−1, with no significant matrix effects observed for docetaxel. The validated SPE method was deemed suitable for its intended application, as all evaluated parameters met the specifications outlined in current regulatory guidelines. Docetaxel was quantified at 29.9 μg L−1 (±1.3%) in one of the 14 effluent samples collected over a week from the Federal University of Santa Maria Hospital (HUSM). Given that the microbiological treatment system at HUSM does not effectively remove this drug, an advanced degradation process using ozonation was investigated. A Dispersive Liquid-Liquid Microextraction (DLLME) method was developed for bench-scale degradation studies and subsequently applied to assess the degradation of docetaxel via ozonation in real samples. The optimized extraction conditions for docetaxel involved a 10 mL hospital effluent sample at pH 9, with ionic strength adjusted using Na₂SO₄. Methanol served as the disperser solvent, while chloroform was the extracting solvent. The ozonation process achieved a removal efficiency exceeding 97% after 60 minutes of reaction, under optimal conditions of pH 7 and an average ozone production rate of 1.5 g O₃ h⁻¹. These findings indicate that ozonation is an effective treatment strategy, significantly reducing docetaxel concentrations in hospital effluent within a short reaction timeframe.