Anne Migan-Dubois
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anne Migan-Dubois has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Demba Diallo
GeePs, CNRS, CentraleSupélec, Université Paris-Saclay, 91190 Gif-sur-Yvette, France
2 shared publications - Jordi Badosa
LMD/IPSL, École Polytechnique, IP Paris, Sorbonne Université, ENS, PSL University, CNRS, 91128 Palaiseau, France
2 shared publications - Vincent Bourdin
LIMSI-CNRS
2 shared publications - Zakaria Djebbour
GeePs (Group of electrical engineering – Paris), UMR CNRS 8507, CentraleSupélec Univ. Paris‐Sud, Université Paris‐Saclay, Sorbonne Université 11 rue Joliot‐Curie, Plateau de Moulon 91192 Gif‐sur‐Yvette Cedex France
2 shared publications A. Pinos
Department of Microelectronics and Applied Physics, Royal Institute of Technology, Electrum 229, SE-164 40 Kista, Sweden
1 shared publicationA.A. Sirenko
Department of Physics, New Jersey Institute of Technology, Newark, NJ 07102, USA
1 shared publication
Latest Publications
- 4 August 2026
- Published by Elsevier in Energy Conversion and Management
- Vol. 368
Cross-domain photovoltaic cell fault diagnosis using electroluminescence images
- 4 August 2026
- Published by Elsevier in Energy Conversion and Management
- Vol. 368
Cross-domain photovoltaic cell fault diagnosis using electroluminescence images
- Open Access
- 13 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 170418-170436
Enhanced Spectral Ensemble Clustering for Fault Diagnosis: Application to Photovoltaic Systems
The role of clustering in unsupervised fault diagnosis is significant, but different clustering techniques can yield varied results and cause inevitable uncertainty. Ensemble clustering methods have been introduced to tackle this challenge. This study presents a novel integrated technique in the field of fault diagnosis using spectral ensemble clustering. A new dimensionality reduction technique is proposed to intelligently identify faults, even in ambiguous scenarios, by exploiting the informative segment of the underlying bipartite graph. This is achieved by identifying and extracting the most informative sections of the bipartite graph based on the eigenvector centrality measure of nodes within the graph. The proposed method is applied to experimental current-voltage (I-V) curve data collected from a real photovoltaic (PV) platform. The obtained results remarkably improved the accuracy of aging fault detection to more than 83.50%, outperforming the existing state-of-the-art approaches. We also decided to separately analyze the ensemble clustering part of our FDD method, which indicated surpassing performance compared to similar methods by evaluating commonly used datasets like handwritten datasets. This proves that the proposed approach inherently holds promise for application in various real-world scenarios that are indicated by ambiguity and complexity.
- 13 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 170418-170436
Open AccessEnhanced Spectral Ensemble Clustering for Fault Diagnosis: Application to Photovoltaic Systems
The role of clustering in unsupervised fault diagnosis is significant, but different clustering techniques can yield varied results and cause inevitable uncertainty. Ensemble clustering methods have been introduced to tackle this challenge. This study presents a novel integrated technique in the field of fault diagnosis using spectral ensemble clustering. A new dimensionality reduction technique is proposed to intelligently identify faults, even in ambiguous scenarios, by exploiting the informative segment of the underlying bipartite graph. This is achieved by identifying and extracting the most informative sections of the bipartite graph based on the eigenvector centrality measure of nodes within the graph. The proposed method is applied to experimental current-voltage (I-V) curve data collected from a real photovoltaic (PV) platform. The obtained results remarkably improved the accuracy of aging fault detection to more than 83.50%, outperforming the existing state-of-the-art approaches. We also decided to separately analyze the ensemble clustering part of our FDD method, which indicated surpassing performance compared to similar methods by evaluating commonly used datasets like handwritten datasets. This proves that the proposed approach inherently holds promise for application in various real-world scenarios that are indicated by ambiguity and complexity.
- Open Access
- 15 October 2021
- Published by Wiley in International Journal of Photoenergy
- Vol. 2021, 1-14
Estimation of the Uncertainty due to Each Step of Simulating the Photovoltaic Conversion under Real Operating Conditions
The simulation of photovoltaic installations is a major issue for their sizing, their smart grid operation, and their fault detection and diagnosis. In this article, we study in detail every step of the simulation chain, either from the global horizontal irradiance and the ambient temperature (i.e., 4 steps of simulation) or considering the global in-plane irradiance and the module operating temperature (i.e., 1 step of simulation). The average quality estimation of the models is made through the calculations of average annual error between estimations and measurements, from 2016 to 2020. We have shown that the most uncertain step is the conversion of the global irradiance in its diffuse and direct components (17.2%, 2 models tested). If the model goes up to the in-plane irradiance, the average annual error decreases to 5.3% (6 models tested). The photovoltaic module temperature calculation induces an error of less than 2°C (4 models tested with 2 configurations). Meanwhile, the photoelectrical conversion shows a 3.5% error, similar to the measurement uncertainties, considering as input, the modules temperature, and the in-plane irradiance. If the simulation goes from the global irradiance and the ambient temperature measured locally, the estimation leads to a 6.7% average annual error. If the local measurements are not available, we can use the closest meteorological station’s records (13 for our study), and the error becomes 12.1%. Finally, we can also use the satellite images that lead to a 15.2% error, for average per year. The impact of available input shows that modeling the DC photovoltaic production, using global horizontal irradiance and ambient temperature, gives rise to an error of 6.6% for local measurements, 12.1% for weather station measurements, and 15.2% for satellite images estimations. This article thus draws up a review of the existing models, allowing to calculate the DC production of a photovoltaic module, depending on the atmospheric conditions, and highlights the most precise or most critical steps, considering in situ and weather station ground-based measurements, and also estimation from satellite images.
- 15 October 2021
- Published by Wiley in International Journal of Photoenergy
- Vol. 2021, 1-14
Open AccessEstimation of the Uncertainty due to Each Step of Simulating the Photovoltaic Conversion under Real Operating Conditions
The simulation of photovoltaic installations is a major issue for their sizing, their smart grid operation, and their fault detection and diagnosis. In this article, we study in detail every step of the simulation chain, either from the global horizontal irradiance and the ambient temperature (i.e., 4 steps of simulation) or considering the global in-plane irradiance and the module operating temperature (i.e., 1 step of simulation). The average quality estimation of the models is made through the calculations of average annual error between estimations and measurements, from 2016 to 2020. We have shown that the most uncertain step is the conversion of the global irradiance in its diffuse and direct components (17.2%, 2 models tested). If the model goes up to the in-plane irradiance, the average annual error decreases to 5.3% (6 models tested). The photovoltaic module temperature calculation induces an error of less than 2°C (4 models tested with 2 configurations). Meanwhile, the photoelectrical conversion shows a 3.5% error, similar to the measurement uncertainties, considering as input, the modules temperature, and the in-plane irradiance. If the simulation goes from the global irradiance and the ambient temperature measured locally, the estimation leads to a 6.7% average annual error. If the local measurements are not available, we can use the closest meteorological station’s records (13 for our study), and the error becomes 12.1%. Finally, we can also use the satellite images that lead to a 15.2% error, for average per year. The impact of available input shows that modeling the DC photovoltaic production, using global horizontal irradiance and ambient temperature, gives rise to an error of 6.6% for local measurements, 12.1% for weather station measurements, and 15.2% for satellite images estimations. This article thus draws up a review of the existing models, allowing to calculate the DC production of a photovoltaic module, depending on the atmospheric conditions, and highlights the most precise or most critical steps, considering in situ and weather station ground-based measurements, and also estimation from satellite images.
- Open Access
A Two-Step Energy Management Method Guided by Day-Ahead Quantile Solar Forecasts: Cross-Impacts on Four Services for Smart-Buildings
The research work hereby presented, emerges from the urge to answer the well-known question of how the uncertainty of intermittent renewable sources affects the performance of a microgrid and how could we deal with it. More specifically, we want to evaluate what could be the impact in performance of a microgrid that is intended to serve a smart-building (powered by photovoltaic panels and with battery energy storage), when the uncertainty of the photovoltaic-production forecasts is considered in the energy management process through the use of quantile forecasts. For this, several objectives (or services) are targeted based in a two-step (double-objective) energy management framework, which combines optimization-based and rule-based algorithms. The performance is evaluated based on some particular services, namely: energy cost, carbon footprint, grid peak power, and grid commitment; with the latter being a novel service proposed in the domain of microgrids. Simulations are performed whlie using data of a study-case microgrid (Drahi-Xnovation center, Ecole Polytechnique, France). The use of quantile forecasts (obtained with an analog-ensemble method) is tested as a mean to deal with (i.e., decrease) the uncertainty of the solar PV production. The proposed energy management framework is compared with basic reference strategies and the results show the superior performance of the former in almost all of the proposed services and forecasting scenarios. The fact of how optimizing for some services during the scheduling (i.e., grid commitment) can be highly detrimental for the performance of the non-targeted services, is an interesting finding of this work. The differences regarding the optimal forecasting eccentricity (i.e., the forecasting quantile) required when optimizing for the different services and seasons of the year is also considered an important conclusion of the study. This fact highlights the usefulness of the quantile forecasting approach in an energy management system, as a tool to deal with the intrinsic uncertainty of PV power production.
Open AccessA Two-Step Energy Management Method Guided by Day-Ahead Quantile Solar Forecasts: Cross-Impacts on Four Services for Smart-Buildings
The research work hereby presented, emerges from the urge to answer the well-known question of how the uncertainty of intermittent renewable sources affects the performance of a microgrid and how could we deal with it. More specifically, we want to evaluate what could be the impact in performance of a microgrid that is intended to serve a smart-building (powered by photovoltaic panels and with battery energy storage), when the uncertainty of the photovoltaic-production forecasts is considered in the energy management process through the use of quantile forecasts. For this, several objectives (or services) are targeted based in a two-step (double-objective) energy management framework, which combines optimization-based and rule-based algorithms. The performance is evaluated based on some particular services, namely: energy cost, carbon footprint, grid peak power, and grid commitment; with the latter being a novel service proposed in the domain of microgrids. Simulations are performed whlie using data of a study-case microgrid (Drahi-Xnovation center, Ecole Polytechnique, France). The use of quantile forecasts (obtained with an analog-ensemble method) is tested as a mean to deal with (i.e., decrease) the uncertainty of the solar PV production. The proposed energy management framework is compared with basic reference strategies and the results show the superior performance of the former in almost all of the proposed services and forecasting scenarios. The fact of how optimizing for some services during the scheduling (i.e., grid commitment) can be highly detrimental for the performance of the non-targeted services, is an interesting finding of this work. The differences regarding the optimal forecasting eccentricity (i.e., the forecasting quantile) required when optimizing for the different services and seasons of the year is also considered an important conclusion of the study. This fact highlights the usefulness of the quantile forecasting approach in an energy management system, as a tool to deal with the intrinsic uncertainty of PV power production.
- 14 January 2019
- Published by Wiley in Progress in Photovoltaics: Research and Applications
- Vol. 27 (4) , 306-315
Bandgap engineered smart three‐terminal solar cell: New perspectives towards very high efficiencies in the silicon world
We present the design of a new architecture of three‐terminal (3‐T) photovoltaic tandem solar cells. It combines an interdigitated back contacted (IBC) bottom lateral subcell with a heterojunction vertical top cell. In this concept, the two subcells can work independently and there is no need for tunnel junctions. It is particularly well suited to silicon back contact subcells and to various types of top cell materials from III‐V compounds or perovskites. The working principle is detailed here using as an example a p/i III‐V front stack onto n‐type silicon IBC bottom cell. We perform two‐dimensional (2D) modeling using realistic material input parameters and show how interface bandgap engineering can improve the tandem cell efficiency up to a reachable 35% value. The proposed cell concept named bandgap engineered smart silicon three‐terminal (BESTT) cell can be realized with less technological steps and at a lower cost compared with the conventional four‐terminal process.
- 14 January 2019
- Published by Wiley in Progress in Photovoltaics: Research and Applications
- Vol. 27 (4) , 306-315
Bandgap engineered smart three‐terminal solar cell: New perspectives towards very high efficiencies in the silicon world
We present the design of a new architecture of three‐terminal (3‐T) photovoltaic tandem solar cells. It combines an interdigitated back contacted (IBC) bottom lateral subcell with a heterojunction vertical top cell. In this concept, the two subcells can work independently and there is no need for tunnel junctions. It is particularly well suited to silicon back contact subcells and to various types of top cell materials from III‐V compounds or perovskites. The working principle is detailed here using as an example a p/i III‐V front stack onto n‐type silicon IBC bottom cell. We perform two‐dimensional (2D) modeling using realistic material input parameters and show how interface bandgap engineering can improve the tandem cell efficiency up to a reachable 35% value. The proposed cell concept named bandgap engineered smart silicon three‐terminal (BESTT) cell can be realized with less technological steps and at a lower cost compared with the conventional four‐terminal process.
- 26 August 2008
- Published by Elsevier in Journal of Crystal Growth
- Vol. 310 (23) , 4927-4931
AlGaN/AlN multiple quantum wells grown by MOVPE on AlN templates using nitrogen as a carrier gas
- 26 August 2008
- Published by Elsevier in Journal of Crystal Growth
- Vol. 310 (23) , 4927-4931
AlGaN/AlN multiple quantum wells grown by MOVPE on AlN templates using nitrogen as a carrier gas