Vincent Bourdin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Vincent Bourdin has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Ph. Grenier
LIMSI-CNRS
8 shared publicationsF. Meunier
Limsi BP 133 F91403 Orsay, France
4 shared publicationsL.M. Sun
LIMSI-CNRS
4 shared publicationsA. Malka-Edery
LIMSI-CNRS
2 shared publicationsAnne Migan-Dubois
GeePs; CNRS UMR 8507; CentraleSuplec; Univ Paris-Sud; Sorbonne Universit,Gif-sur-Yvette Cedex,France,F-91192
2 shared publications- Anne Migan-Dubois
University Paris-Saclay, CentraleSupelec, CNRS, GeePs, Gif-Sur-Yvette, France
2 shared publications
Latest Publications
- Open Access
- 15 October 2021
- Published by Wiley in International Journal of Photoenergy
- Vol. 2021, 1-14
Estimation of the Uncertainty due to Each Step of Simulating the Photovoltaic Conversion under Real Operating Conditions
The simulation of photovoltaic installations is a major issue for their sizing, their smart grid operation, and their fault detection and diagnosis. In this article, we study in detail every step of the simulation chain, either from the global horizontal irradiance and the ambient temperature (i.e., 4 steps of simulation) or considering the global in-plane irradiance and the module operating temperature (i.e., 1 step of simulation). The average quality estimation of the models is made through the calculations of average annual error between estimations and measurements, from 2016 to 2020. We have shown that the most uncertain step is the conversion of the global irradiance in its diffuse and direct components (17.2%, 2 models tested). If the model goes up to the in-plane irradiance, the average annual error decreases to 5.3% (6 models tested). The photovoltaic module temperature calculation induces an error of less than 2°C (4 models tested with 2 configurations). Meanwhile, the photoelectrical conversion shows a 3.5% error, similar to the measurement uncertainties, considering as input, the modules temperature, and the in-plane irradiance. If the simulation goes from the global irradiance and the ambient temperature measured locally, the estimation leads to a 6.7% average annual error. If the local measurements are not available, we can use the closest meteorological station’s records (13 for our study), and the error becomes 12.1%. Finally, we can also use the satellite images that lead to a 15.2% error, for average per year. The impact of available input shows that modeling the DC photovoltaic production, using global horizontal irradiance and ambient temperature, gives rise to an error of 6.6% for local measurements, 12.1% for weather station measurements, and 15.2% for satellite images estimations. This article thus draws up a review of the existing models, allowing to calculate the DC production of a photovoltaic module, depending on the atmospheric conditions, and highlights the most precise or most critical steps, considering in situ and weather station ground-based measurements, and also estimation from satellite images.
- 15 October 2021
- Published by Wiley in International Journal of Photoenergy
- Vol. 2021, 1-14
Open AccessEstimation of the Uncertainty due to Each Step of Simulating the Photovoltaic Conversion under Real Operating Conditions
The simulation of photovoltaic installations is a major issue for their sizing, their smart grid operation, and their fault detection and diagnosis. In this article, we study in detail every step of the simulation chain, either from the global horizontal irradiance and the ambient temperature (i.e., 4 steps of simulation) or considering the global in-plane irradiance and the module operating temperature (i.e., 1 step of simulation). The average quality estimation of the models is made through the calculations of average annual error between estimations and measurements, from 2016 to 2020. We have shown that the most uncertain step is the conversion of the global irradiance in its diffuse and direct components (17.2%, 2 models tested). If the model goes up to the in-plane irradiance, the average annual error decreases to 5.3% (6 models tested). The photovoltaic module temperature calculation induces an error of less than 2°C (4 models tested with 2 configurations). Meanwhile, the photoelectrical conversion shows a 3.5% error, similar to the measurement uncertainties, considering as input, the modules temperature, and the in-plane irradiance. If the simulation goes from the global irradiance and the ambient temperature measured locally, the estimation leads to a 6.7% average annual error. If the local measurements are not available, we can use the closest meteorological station’s records (13 for our study), and the error becomes 12.1%. Finally, we can also use the satellite images that lead to a 15.2% error, for average per year. The impact of available input shows that modeling the DC photovoltaic production, using global horizontal irradiance and ambient temperature, gives rise to an error of 6.6% for local measurements, 12.1% for weather station measurements, and 15.2% for satellite images estimations. This article thus draws up a review of the existing models, allowing to calculate the DC production of a photovoltaic module, depending on the atmospheric conditions, and highlights the most precise or most critical steps, considering in situ and weather station ground-based measurements, and also estimation from satellite images.
- Open Access
A Two-Step Energy Management Method Guided by Day-Ahead Quantile Solar Forecasts: Cross-Impacts on Four Services for Smart-Buildings
The research work hereby presented, emerges from the urge to answer the well-known question of how the uncertainty of intermittent renewable sources affects the performance of a microgrid and how could we deal with it. More specifically, we want to evaluate what could be the impact in performance of a microgrid that is intended to serve a smart-building (powered by photovoltaic panels and with battery energy storage), when the uncertainty of the photovoltaic-production forecasts is considered in the energy management process through the use of quantile forecasts. For this, several objectives (or services) are targeted based in a two-step (double-objective) energy management framework, which combines optimization-based and rule-based algorithms. The performance is evaluated based on some particular services, namely: energy cost, carbon footprint, grid peak power, and grid commitment; with the latter being a novel service proposed in the domain of microgrids. Simulations are performed whlie using data of a study-case microgrid (Drahi-Xnovation center, Ecole Polytechnique, France). The use of quantile forecasts (obtained with an analog-ensemble method) is tested as a mean to deal with (i.e., decrease) the uncertainty of the solar PV production. The proposed energy management framework is compared with basic reference strategies and the results show the superior performance of the former in almost all of the proposed services and forecasting scenarios. The fact of how optimizing for some services during the scheduling (i.e., grid commitment) can be highly detrimental for the performance of the non-targeted services, is an interesting finding of this work. The differences regarding the optimal forecasting eccentricity (i.e., the forecasting quantile) required when optimizing for the different services and seasons of the year is also considered an important conclusion of the study. This fact highlights the usefulness of the quantile forecasting approach in an energy management system, as a tool to deal with the intrinsic uncertainty of PV power production.
Open AccessA Two-Step Energy Management Method Guided by Day-Ahead Quantile Solar Forecasts: Cross-Impacts on Four Services for Smart-Buildings
The research work hereby presented, emerges from the urge to answer the well-known question of how the uncertainty of intermittent renewable sources affects the performance of a microgrid and how could we deal with it. More specifically, we want to evaluate what could be the impact in performance of a microgrid that is intended to serve a smart-building (powered by photovoltaic panels and with battery energy storage), when the uncertainty of the photovoltaic-production forecasts is considered in the energy management process through the use of quantile forecasts. For this, several objectives (or services) are targeted based in a two-step (double-objective) energy management framework, which combines optimization-based and rule-based algorithms. The performance is evaluated based on some particular services, namely: energy cost, carbon footprint, grid peak power, and grid commitment; with the latter being a novel service proposed in the domain of microgrids. Simulations are performed whlie using data of a study-case microgrid (Drahi-Xnovation center, Ecole Polytechnique, France). The use of quantile forecasts (obtained with an analog-ensemble method) is tested as a mean to deal with (i.e., decrease) the uncertainty of the solar PV production. The proposed energy management framework is compared with basic reference strategies and the results show the superior performance of the former in almost all of the proposed services and forecasting scenarios. The fact of how optimizing for some services during the scheduling (i.e., grid commitment) can be highly detrimental for the performance of the non-targeted services, is an interesting finding of this work. The differences regarding the optimal forecasting eccentricity (i.e., the forecasting quantile) required when optimizing for the different services and seasons of the year is also considered an important conclusion of the study. This fact highlights the usefulness of the quantile forecasting approach in an energy management system, as a tool to deal with the intrinsic uncertainty of PV power production.
- 1 February 2020
- Published by Elsevier in Solar Energy
- Vol. 197, 266-278
Errors in PV power modelling due to the lack of spectral and angular details of solar irradiance inputs
- 1 February 2020
- Published by Elsevier in Solar Energy
- Vol. 197, 266-278
Errors in PV power modelling due to the lack of spectral and angular details of solar irradiance inputs
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1572-1577
Evaluation of the plane of array irradiance for a photovoltaic installation equipped with flat reflectors in different geographical locations
This work describes a plane of array irradiance (GPOA) estimation study performed for a PV system equipped with flat reflectors. In fact, adding planar reflectors in front of the PV arrays will result in an increased GPOA reaching the panel’s surface. This paper focuses on the GPOA study for a PV-Reflector system architecture in six different geographical locations. The study was conducted over a five years period of time and under various weather conditions. An analytical model was developed and experimentally validated for that purpose allowing the estimation and assessment of the GPOA for such system. Therefore, the study was performed according to an architectural optimization approach considering several geometrical variations in order to achieve the highest plane of array irradiance. The highest annual gain in GPOA added by the reflectors was obtained for Athens (35%) and regions with close latitudes showed quite similar results.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1572-1577
Evaluation of the plane of array irradiance for a photovoltaic installation equipped with flat reflectors in different geographical locations
This work describes a plane of array irradiance (GPOA) estimation study performed for a PV system equipped with flat reflectors. In fact, adding planar reflectors in front of the PV arrays will result in an increased GPOA reaching the panel’s surface. This paper focuses on the GPOA study for a PV-Reflector system architecture in six different geographical locations. The study was conducted over a five years period of time and under various weather conditions. An analytical model was developed and experimentally validated for that purpose allowing the estimation and assessment of the GPOA for such system. Therefore, the study was performed according to an architectural optimization approach considering several geometrical variations in order to achieve the highest plane of array irradiance. The highest annual gain in GPOA added by the reflectors was obtained for Athens (35%) and regions with close latitudes showed quite similar results.
- 28 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 5 (6) , 1686-1691
Experimental and Numerical Study of the Influence of String Mismatch on the Yield of PV Modules Augmented By Static Planar Reflectors
Photovoltaic (PV) modules are generally installed by the application of empirical rules aimed at reducing shadows during the periods of high solar irradiation. A traditional installation on a horizontal surface results in largely spaced rows of modules with a relatively low tilt angle. The addition of interrow reflectors results in more direct and diffuse flux transmitted to the cells. The Amélioration de l'Efficacité Photovoltaïque (Aleph) project aims to define clear rules for optimal settings of systems of PV module rows with fixed interrow planar reflectors in a given location and under a given climate. Two PV technologies are tested for performance with this type of system: amorphous silicon (a-Si) and polycrystalline silicon (p-Si). This study combines experiments on panel behavior in an outdoor environment on the Site Instrumental de Recherche par Télédétection Atmosphérique (SIRTA) meteorology platform and a multiphysics numerical model used to couple all the important physical phenomena and accurately describe the system behavior. The model includes a ray tracing radiation/optics module based on the Monte-Carlo method, as well as an electrical module simulated in SPICE. This study presents the influence of the string mismatch losses, which is present at periods of heterogeneous illumination, on the yield of PV modules augmented by static planar reflectors.
- 28 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 5 (6) , 1686-1691
Experimental and Numerical Study of the Influence of String Mismatch on the Yield of PV Modules Augmented By Static Planar Reflectors
Photovoltaic (PV) modules are generally installed by the application of empirical rules aimed at reducing shadows during the periods of high solar irradiation. A traditional installation on a horizontal surface results in largely spaced rows of modules with a relatively low tilt angle. The addition of interrow reflectors results in more direct and diffuse flux transmitted to the cells. The Amélioration de l'Efficacité Photovoltaïque (Aleph) project aims to define clear rules for optimal settings of systems of PV module rows with fixed interrow planar reflectors in a given location and under a given climate. Two PV technologies are tested for performance with this type of system: amorphous silicon (a-Si) and polycrystalline silicon (p-Si). This study combines experiments on panel behavior in an outdoor environment on the Site Instrumental de Recherche par Télédétection Atmosphérique (SIRTA) meteorology platform and a multiphysics numerical model used to couple all the important physical phenomena and accurately describe the system behavior. The model includes a ray tracing radiation/optics module based on the Monte-Carlo method, as well as an electrical module simulated in SPICE. This study presents the influence of the string mismatch losses, which is present at periods of heterogeneous illumination, on the yield of PV modules augmented by static planar reflectors.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Experimental and numerical study of the influence of string mismatch on the yield of PV modules augmented by static planar reflectors
Photovoltaic (PV) modules are generally installed by the application of empirical rules aimed at reducing shadows during the periods of high solar irradiation. A traditional installation on a horizontal surface results in largely spaced rows of modules with a relatively low tilt angle. The addition of inter-row reflectors results in more direct and diffuse flux transmitted to the cells. The “Aleph” (Amélioration de l'Efficacité Photovoltaïque) project aims to define clear rules for optimal settings of systems of PV module rows with fixed inter-row planar reflectors in a given location and under a given climate. Two PV technologies are tested for performance with this type of system: amorphous silicon (a-Si) and polycrystalline silicon (p-Si). This work combines experiments on panel behavior in an outdoor environment on the SIRTA (Site Instrumental de Recherche par Télédétection Atmosphérique) meteorology platform and a multiphysics numerical model used to couple all the important physical phenomena and accurately describe the system behavior. The model includes a ray tracing radiation/optics module based on the Monte-Carlo method, as well as an electrical module simulated in SPICE. This work presents the influence of the string mismatch losses, present at periods of heterogeneous illumination, on the yield of PV modules augmented by static planar reflectors.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Experimental and numerical study of the influence of string mismatch on the yield of PV modules augmented by static planar reflectors
Photovoltaic (PV) modules are generally installed by the application of empirical rules aimed at reducing shadows during the periods of high solar irradiation. A traditional installation on a horizontal surface results in largely spaced rows of modules with a relatively low tilt angle. The addition of inter-row reflectors results in more direct and diffuse flux transmitted to the cells. The “Aleph” (Amélioration de l'Efficacité Photovoltaïque) project aims to define clear rules for optimal settings of systems of PV module rows with fixed inter-row planar reflectors in a given location and under a given climate. Two PV technologies are tested for performance with this type of system: amorphous silicon (a-Si) and polycrystalline silicon (p-Si). This work combines experiments on panel behavior in an outdoor environment on the SIRTA (Site Instrumental de Recherche par Télédétection Atmosphérique) meteorology platform and a multiphysics numerical model used to couple all the important physical phenomena and accurately describe the system behavior. The model includes a ray tracing radiation/optics module based on the Monte-Carlo method, as well as an electrical module simulated in SPICE. This work presents the influence of the string mismatch losses, present at periods of heterogeneous illumination, on the yield of PV modules augmented by static planar reflectors.
- 1 June 2014
- Published by Elsevier in Solar Energy Materials and Solar Cells
- Vol. 125, 325-338
Coupling optical and thermal models to accurately predict PV panel electricity production
- 1 June 2014
- Published by Elsevier in Solar Energy Materials and Solar Cells
- Vol. 125, 325-338
Coupling optical and thermal models to accurately predict PV panel electricity production
- Open Access
- 25 September 2005
- Published by Leipzig University Library in Diffusion Fundamentals
- Vol. 2
Diffusion of n-alkanes in MFI-type zeolites
- 25 September 2005
- Published by Leipzig University Library in Diffusion Fundamentals
- Vol. 2
Open AccessDiffusion of n-alkanes in MFI-type zeolites
- 1 January 2001
- Published by Springer Nature in Adsorption
- Vol. 7 (1) , 5-16
Determination of the Kinetic and Thermodynamic Parameters of Adsorption Processes by a Volume Step Thermal Method
- 1 January 2001
- Published by Springer Nature in Adsorption
- Vol. 7 (1) , 5-16
Determination of the Kinetic and Thermodynamic Parameters of Adsorption Processes by a Volume Step Thermal Method
- 1 March 1999
- Published by Springer Nature in Adsorption
- Vol. 5 (2) , 135-143
A Temperature Frequency Response Method for Adsorption Kinetics Measurements
- 1 March 1999
- Published by Springer Nature in Adsorption
- Vol. 5 (2) , 135-143
A Temperature Frequency Response Method for Adsorption Kinetics Measurements