VSVassilis Sboros

Vassilis Sboros

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Vassilis Sboros has a total of 205 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Super-resolution ultrasound imaging of ischaemia flow: An in silico study

    by Lachlan Arthur, Vasiliki Voulgaridou, Georgios Papageorgiou, Weiping Lu, Steven R. McDougall, Vassilis Sboros


  • Open Access

    Comparison of contrast-enhanced ultrasound imaging (CEUS) and super-resolution ultrasound (SRU) for the quantification of ischaemia flow redistribution: a theoretical study

    by Lachlan J M B Arthur, Vasiliki Voulgaridou, Mairead B Butler, Georgios Papageorgiou, Weiping Lu, Steven R McDougall, Vassilis Sboros

    The study of microcirculation can reveal important information related to pathology. Focusing on alterations that are represented by an obstruction of blood flow in microcirculatory regions may provide an insight into vascular biomarkers. The current in silico study assesses the capability of contrast enhanced ultrasound (CEUS) and super-resolution ultrasound imaging (SRU) flow-quantification to study occlusive actions in a microvascular bed, particularly the ability to characterise known and model induced flow behaviours. The aim is to investigate theoretical limits with the use of CEUS and SRU in order to propose realistic biomarker targets relevant for clinical diagnosis. Results from CEUS flow parameters display limitations congruent with prior investigations. Conventional resolution limits lead to signals dominated by large vessels, making discrimination of microvasculature specific signals difficult. Additionally, some occlusions lead to weakened parametric correlation against flow rate in the remainder of the network. Loss of correlation is dependent on the degree to which flow is redistributed, with comparatively minor redistribution correlating in accordance with ground truth measurements for change in mean transit time, dMTT (CEUS, R = 0.85; GT, R = 0.82) and change in peak intensity, d I p (CEUS, R = 0.87; GT, R = 0.96). Major redistributions, however, result in a loss of correlation, demonstrating that the effectiveness of time-intensity curve parameters is influenced by the site of occlusion. Conversely, results from SRU processing provides accurate depiction of the anatomy and dynamics present in the vascular bed, that extends to individual microvessels. Correspondence between model vessel structure displayed in SRU maps with the ground truth was > 91 % for cases of minor and major flow redistributions. In conclusion, SRU appears to be a highly promising technology in the quantification of subtle flow phenomena due ischaemia induced vascular flow redistribution.


  • Open Access

    Vessel recovery using ultrasound localisation microscopy: An in silico comparative study between minimum variance and delay-and-sum beamformers

    by Vasiliki Voulgaridou, Barbara Nicolas, Steven McDougall, Lachlan Arthur, Georgios Papageorgiou, Mairead Butler, Evangelos Kanoulas, Konstantinos Diamantis, Weiping Lu, Vassilis Sboros


  • ULTRA-SR Challenge: Assessment of Ultrasound Localization and TRacking Algorithms for Super-Resolution Imaging

    by Marcelo Lerendegui, Kai Riemer, Georgios Papageorgiou, Bingxue Wang, Lachlan Arthur, Arthur Chavignon, Tao Zhang, Olivier Couture, Pingtong Huang, Ashikuzzaman, et al.

    With the widespread interest and uptake of super-resolution ultrasound (SRUS) through localization and tracking of microbubbles, also known as ultrasound localization microscopy (ULM), many localization and tracking algorithms have been developed. ULM can image many centimeters into tissue in-vivo and track microvascular flow non-invasively with sub-diffraction resolution. In a significant community effort, we organized a challenge, Ultrasound Localization and TRacking Algorithms for Super-Resolution (ULTRA-SR). The aims of this paper are threefold: to describe the challenge organization, data generation, and winning algorithms; to present the metrics and methods for evaluating challenge entrants; and to report results and findings of the evaluation. Realistic ultrasound datasets containing microvascular flow for different clinical ultrasound frequencies were simulated, using vascular flow physics, acoustic field simulation and nonlinear bubble dynamics simulation. Based on these datasets, 38 submissions from 24 research groups were evaluated against ground truth using an evaluation framework with six metrics, three for localization and three for tracking. In-vivo mouse brain and human lymph node data were also provided, and performance assessed by an expert panel. Winning algorithms are described and discussed. The publicly available data with ground truth and the defined metrics for both localization and tracking present a valuable resource for researchers to benchmark algorithms and software, identify optimized methods/software for their data, and provide insight into the current limits of the field. In conclusion, Ultra-SR challenge has provided benchmarking data and tools as well as direct comparison and insights for a number of the state-of-the art localization and tracking algorithms.


  • Open Access

    Modeling atomic force microscopy and shell mechanical properties estimation of coated microbubbles

    by Alkmini Lytra, Vassilis Sboros, Antonios Giannakopoulos, Nikos Pelekasis

    We present comparison with experiments and a methodology for robust shell mechanical properties estimation, based on our theoretical/numerical model for the static response of coated microbubbles to compression from an atomic force microscope.


  • Do raw signal data provide better localisation than image data for super-resolution imaging?

    by Konstantinos Diamantis, Tom Anderson, Paul Dalgarno, Jorgen Arendt Jensen, Vassilis Sboros

    Super-resolution ultrasound imaging has evolved using image analysis algorithms. However, the images used are not generated with beamformers that are designed for single particle imaging, but rather for anatomy that provide continuous features (eg. delay and sum). In order to compare image- and signal- derived localisation accuracies we used multi-focal imaging combined with the simple metric of sharpness. A 7 MHz (λ=212 μm) linear array with 192 elements is used to scan a phantom that is composed of a thin wire. The average axial localisation accuracy using the sharpness method on the raw signal is ≈ 0.01λ while the centre of mass best measurement on image data provided ≈ 0.06λ. It is concluded that image derived localisation is compromised by the process that generates the image. It is therefore suggested that super-resolution imaging will benefit from alternative beamforming methods that are designed to enhance single particle imaging.

  • Minimum Variance beamforming for closely spaced microbubbles

    by Konstantinos Diamantis, Mairead Butler, Tom Anderson, Jorgen Arendt Jensen, Vassilis Sboros

    The Minimum Variance beamformer (MVB) is known to outperform the conventional Delay-and-Sum (DAS) beamformer in terms of lateral resolution. Super-resolution ultrasound imaging (SRI) relies on localising several microbubbles in each image, and thus the objective of this work is to assess how the distance between two scatterers can affect their apparent size or shape on the image by using the MVB. The MVB method was employed on simulated point scatter data with a 8 MHz (λ=192 μm) 128-element linear array probe. Two scatterers were placed in variable positions in three dimensions and closely spaced to each other. The lateral Full-Width-Half-Maximum (FWHM) was used for performance evaluation. It was found that the FWHM of each scatterer was affected by the presence of another, and decreased as the distance between two scatterers increased. Relative positioning in axial (0.1mm apart) or azimuthal (1 mm apart) positions provided a tilted scatterer appearance. As the MVB differentiates scatterers at closer distances compared to the DAS beamformer, it is concluded that a larger number of microbubbles can be counted using the former.


  • Open Access

    Differentiation of Vascular Characteristics Using Contrast-Enhanced Ultrasound Imaging

    by Mairead Butler, Antonios Perperidis, Jean-Luc Matteo Zahra, Nadia Silva, Michalakis Averkiou, W. Colin Duncan, Alan McNeilly, Vassilis Sboros


  • Open Access

    Super-Resolution Contrast-Enhanced Ultrasound Methodology for the Identification of In Vivo Vascular Dynamics in 2D

    by Evangelos Kanoulas, Mairead Butler, Caitlin Rowley, Vasiliki Voulgaridou, Konstantinos Diamantis, William Colin Duncan, Alan McNeilly, Michalakis Averkiou, Hessel Wijkstra, Massimo Mischi, et al.

    Objectives: The aim of this study was to provide an ultrasound-based super-resolution methodology that can be implemented using clinical 2-dimensional ultrasound equipment and standard contrast-enhanced ultrasound modes. In addition, the aim is to achieve this for true-to-life patient imaging conditions, including realistic examination times of a few minutes and adequate image penetration depths that can be used to scan entire organs without sacrificing current super-resolution ultrasound imaging performance. Methods: Standard contrast-enhanced ultrasound was used along with bolus or infusion injections of SonoVue (Bracco, Geneva, Switzerland) microbubble (MB) suspensions. An image analysis methodology, translated from light microscopy algorithms, was developed for use with ultrasound contrast imaging video data. New features that are tailored for ultrasound contrast image data were developed for MB detection and segmentation, so that the algorithm can deal with single and overlapping MBs. The method was tested initially on synthetic data, then with a simple microvessel phantom, and then with in vivo ultrasound contrast video loops from sheep ovaries. Tracks detailing the vascular structure and corresponding velocity map of the sheep ovary were reconstructed. Images acquired from light microscopy, optical projection tomography, and optical coherence tomography were compared with the vasculature network that was revealed in the ultrasound contrast data. The final method was applied to clinical prostate data as a proof of principle. Results: Features of the ovary identified in optical modalities mentioned previously were also identified in the ultrasound super-resolution density maps. Follicular areas, follicle wall, vessel diameter, and tissue dimensions were very similar. An approximately 8.5-fold resolution gain was demonstrated in vessel width, as vessels of width down to 60 μm were detected and verified (λ = 514 μm). Best agreement was found between ultrasound measurements and optical coherence tomography with 10% difference in the measured vessel widths, whereas ex vivo microscopy measurements were significantly lower by 43% on average. The results were mostly achieved using video loops of under 2-minute duration that included respiratory motion. A feasibility study on a human prostate showed good agreement between density and velocity ultrasound maps with the histological evaluation of the location of a tumor. Conclusions: The feasibility of a 2-dimensional contrast-enhanced ultrasound-based super-resolution method was demonstrated using in vitro, synthetic and in vivo animal data. The method reduces the examination times to a few minutes using state-of-the-art ultrasound equipment and can provide super-resolution maps for an entire prostate with similar resolution to that achieved in other studies.