Konstantinos Diamantis
Konstantinos Diamantis has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Vassilis Sboros
School of Engineering & Physical Sciences, Heriot-Watt University, Edinburgh, EH14 4AS, Scotland, United Kingdom
16 shared publications - Jorgen Arendt Jensen
Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, 2800 Lyngby, Denmark
12 shared publications Tom Anderson
The University of Edinburgh,Centre for Cardiovascular Science,Edinburgh,UK
9 shared publications- Paul A. Dalgarno
Heriot-Watt Univ. (United Kingdom)
6 shared publications Alan H. Greenaway
School of Engineering & Physical Sciences, Heriot-Watt University, Edinburgh, UK
4 shared publications- James R. Hopgood
Institute for Imaging, Data and Communications, School of Engineering, University of Edinburgh, Edinburgh, U.K.
3 shared publications
Latest Publications
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1463-1465
Do raw signal data provide better localisation than image data for super-resolution imaging?
Super-resolution ultrasound imaging has evolved using image analysis algorithms. However, the images used are not generated with beamformers that are designed for single particle imaging, but rather for anatomy that provide continuous features (eg. delay and sum). In order to compare image- and signal- derived localisation accuracies we used multi-focal imaging combined with the simple metric of sharpness. A 7 MHz (λ=212 μm) linear array with 192 elements is used to scan a phantom that is composed of a thin wire. The average axial localisation accuracy using the sharpness method on the raw signal is ≈ 0.01λ while the centre of mass best measurement on image data provided ≈ 0.06λ. It is concluded that image derived localisation is compromised by the process that generates the image. It is therefore suggested that super-resolution imaging will benefit from alternative beamforming methods that are designed to enhance single particle imaging.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1463-1465
Do raw signal data provide better localisation than image data for super-resolution imaging?
Super-resolution ultrasound imaging has evolved using image analysis algorithms. However, the images used are not generated with beamformers that are designed for single particle imaging, but rather for anatomy that provide continuous features (eg. delay and sum). In order to compare image- and signal- derived localisation accuracies we used multi-focal imaging combined with the simple metric of sharpness. A 7 MHz (λ=212 μm) linear array with 192 elements is used to scan a phantom that is composed of a thin wire. The average axial localisation accuracy using the sharpness method on the raw signal is ≈ 0.01λ while the centre of mass best measurement on image data provided ≈ 0.06λ. It is concluded that image derived localisation is compromised by the process that generates the image. It is therefore suggested that super-resolution imaging will benefit from alternative beamforming methods that are designed to enhance single particle imaging.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 571-574
Minimum Variance beamforming for closely spaced microbubbles
The Minimum Variance beamformer (MVB) is known to outperform the conventional Delay-and-Sum (DAS) beamformer in terms of lateral resolution. Super-resolution ultrasound imaging (SRI) relies on localising several microbubbles in each image, and thus the objective of this work is to assess how the distance between two scatterers can affect their apparent size or shape on the image by using the MVB. The MVB method was employed on simulated point scatter data with a 8 MHz (λ=192 μm) 128-element linear array probe. Two scatterers were placed in variable positions in three dimensions and closely spaced to each other. The lateral Full-Width-Half-Maximum (FWHM) was used for performance evaluation. It was found that the FWHM of each scatterer was affected by the presence of another, and decreased as the distance between two scatterers increased. Relative positioning in axial (0.1mm apart) or azimuthal (1 mm apart) positions provided a tilted scatterer appearance. As the MVB differentiates scatterers at closer distances compared to the DAS beamformer, it is concluded that a larger number of microbubbles can be counted using the former.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 571-574
Minimum Variance beamforming for closely spaced microbubbles
The Minimum Variance beamformer (MVB) is known to outperform the conventional Delay-and-Sum (DAS) beamformer in terms of lateral resolution. Super-resolution ultrasound imaging (SRI) relies on localising several microbubbles in each image, and thus the objective of this work is to assess how the distance between two scatterers can affect their apparent size or shape on the image by using the MVB. The MVB method was employed on simulated point scatter data with a 8 MHz (λ=192 μm) 128-element linear array probe. Two scatterers were placed in variable positions in three dimensions and closely spaced to each other. The lateral Full-Width-Half-Maximum (FWHM) was used for performance evaluation. It was found that the FWHM of each scatterer was affected by the presence of another, and decreased as the distance between two scatterers increased. Relative positioning in axial (0.1mm apart) or azimuthal (1 mm apart) positions provided a tilted scatterer appearance. As the MVB differentiates scatterers at closer distances compared to the DAS beamformer, it is concluded that a larger number of microbubbles can be counted using the former.
- Open Access
- 3 May 2019
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 54 (8) , 500-516
Super-Resolution Contrast-Enhanced Ultrasound Methodology for the Identification of In Vivo Vascular Dynamics in 2D
Objectives: The aim of this study was to provide an ultrasound-based super-resolution methodology that can be implemented using clinical 2-dimensional ultrasound equipment and standard contrast-enhanced ultrasound modes. In addition, the aim is to achieve this for true-to-life patient imaging conditions, including realistic examination times of a few minutes and adequate image penetration depths that can be used to scan entire organs without sacrificing current super-resolution ultrasound imaging performance. Methods: Standard contrast-enhanced ultrasound was used along with bolus or infusion injections of SonoVue (Bracco, Geneva, Switzerland) microbubble (MB) suspensions. An image analysis methodology, translated from light microscopy algorithms, was developed for use with ultrasound contrast imaging video data. New features that are tailored for ultrasound contrast image data were developed for MB detection and segmentation, so that the algorithm can deal with single and overlapping MBs. The method was tested initially on synthetic data, then with a simple microvessel phantom, and then with in vivo ultrasound contrast video loops from sheep ovaries. Tracks detailing the vascular structure and corresponding velocity map of the sheep ovary were reconstructed. Images acquired from light microscopy, optical projection tomography, and optical coherence tomography were compared with the vasculature network that was revealed in the ultrasound contrast data. The final method was applied to clinical prostate data as a proof of principle. Results: Features of the ovary identified in optical modalities mentioned previously were also identified in the ultrasound super-resolution density maps. Follicular areas, follicle wall, vessel diameter, and tissue dimensions were very similar. An approximately 8.5-fold resolution gain was demonstrated in vessel width, as vessels of width down to 60 μm were detected and verified (λ = 514 μm). Best agreement was found between ultrasound measurements and optical coherence tomography with 10% difference in the measured vessel widths, whereas ex vivo microscopy measurements were significantly lower by 43% on average. The results were mostly achieved using video loops of under 2-minute duration that included respiratory motion. A feasibility study on a human prostate showed good agreement between density and velocity ultrasound maps with the histological evaluation of the location of a tumor. Conclusions: The feasibility of a 2-dimensional contrast-enhanced ultrasound-based super-resolution method was demonstrated using in vitro, synthetic and in vivo animal data. The method reduces the examination times to a few minutes using state-of-the-art ultrasound equipment and can provide super-resolution maps for an entire prostate with similar resolution to that achieved in other studies.
- 3 May 2019
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 54 (8) , 500-516
Open AccessSuper-Resolution Contrast-Enhanced Ultrasound Methodology for the Identification of In Vivo Vascular Dynamics in 2D
Objectives: The aim of this study was to provide an ultrasound-based super-resolution methodology that can be implemented using clinical 2-dimensional ultrasound equipment and standard contrast-enhanced ultrasound modes. In addition, the aim is to achieve this for true-to-life patient imaging conditions, including realistic examination times of a few minutes and adequate image penetration depths that can be used to scan entire organs without sacrificing current super-resolution ultrasound imaging performance. Methods: Standard contrast-enhanced ultrasound was used along with bolus or infusion injections of SonoVue (Bracco, Geneva, Switzerland) microbubble (MB) suspensions. An image analysis methodology, translated from light microscopy algorithms, was developed for use with ultrasound contrast imaging video data. New features that are tailored for ultrasound contrast image data were developed for MB detection and segmentation, so that the algorithm can deal with single and overlapping MBs. The method was tested initially on synthetic data, then with a simple microvessel phantom, and then with in vivo ultrasound contrast video loops from sheep ovaries. Tracks detailing the vascular structure and corresponding velocity map of the sheep ovary were reconstructed. Images acquired from light microscopy, optical projection tomography, and optical coherence tomography were compared with the vasculature network that was revealed in the ultrasound contrast data. The final method was applied to clinical prostate data as a proof of principle. Results: Features of the ovary identified in optical modalities mentioned previously were also identified in the ultrasound super-resolution density maps. Follicular areas, follicle wall, vessel diameter, and tissue dimensions were very similar. An approximately 8.5-fold resolution gain was demonstrated in vessel width, as vessels of width down to 60 μm were detected and verified (λ = 514 μm). Best agreement was found between ultrasound measurements and optical coherence tomography with 10% difference in the measured vessel widths, whereas ex vivo microscopy measurements were significantly lower by 43% on average. The results were mostly achieved using video loops of under 2-minute duration that included respiratory motion. A feasibility study on a human prostate showed good agreement between density and velocity ultrasound maps with the histological evaluation of the location of a tumor. Conclusions: The feasibility of a 2-dimensional contrast-enhanced ultrasound-based super-resolution method was demonstrated using in vitro, synthetic and in vivo animal data. The method reduces the examination times to a few minutes using state-of-the-art ultrasound equipment and can provide super-resolution maps for an entire prostate with similar resolution to that achieved in other studies.
- Open Access
- 24 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 6297-6309
Development of Super-Resolution Sharpness-Based Axial Localization for Ultrasound Imaging
Super-resolution ultrasound mostly uses imagebased methods for the localization of single scatterers. These methods are largely based on the centre of mass (COM) calculation. Sharpness-based localization is an alternative to COM for scatterer localization in the axial direction. Simulated ultrasound point scatterer data (centre frequency f0 = 7 MHz, wavelength λ = 220 μm) showed that the normalized sharpness method can provide scatterer axial localization with an accuracy down to 2 μm (< 0.01λ), which is a two-order of magnitude improvement compared to that achievable by conventional imaging (≈λ), and a 5-fold improvement compared to the COM estimate (≈10 μm or 0.05λ). Similar results were obtained experimentally using wire-target data acquired by the Synthetic Aperture Real-time Ultrasound System (SARUS). The performance of the proposed method was also found to be consistent across different types of ultrasound transmission. The localization precision deteriorates in the presence of noise, but even in very low signal-to-noise-ratio (SNR = 0 dB) the uncertainty was not higher than 6 μm, which outperforms the COM estimate. The method can be implemented in image data as well as using the raw signals. It is proposed that signal derived localization should replace the image-based equivalent, as it provides at least a 10 times improved accuracy.
- 24 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 6297-6309
Open AccessDevelopment of Super-Resolution Sharpness-Based Axial Localization for Ultrasound Imaging
Super-resolution ultrasound mostly uses imagebased methods for the localization of single scatterers. These methods are largely based on the centre of mass (COM) calculation. Sharpness-based localization is an alternative to COM for scatterer localization in the axial direction. Simulated ultrasound point scatterer data (centre frequency f0 = 7 MHz, wavelength λ = 220 μm) showed that the normalized sharpness method can provide scatterer axial localization with an accuracy down to 2 μm (< 0.01λ), which is a two-order of magnitude improvement compared to that achievable by conventional imaging (≈λ), and a 5-fold improvement compared to the COM estimate (≈10 μm or 0.05λ). Similar results were obtained experimentally using wire-target data acquired by the Synthetic Aperture Real-time Ultrasound System (SARUS). The performance of the proposed method was also found to be consistent across different types of ultrasound transmission. The localization precision deteriorates in the presence of noise, but even in very low signal-to-noise-ratio (SNR = 0 dB) the uncertainty was not higher than 6 μm, which outperforms the COM estimate. The method can be implemented in image data as well as using the raw signals. It is proposed that signal derived localization should replace the image-based equivalent, as it provides at least a 10 times improved accuracy.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Bayesian Spectrum Analysis of Non-Linear Ultrasound Contrast Microbubble Signals
The localization of individual contrast microbubbles (MBs)is key to the emerging field of super-resolution ultrasound. The Fourier Transform (FT)is typically used for the frequency domain analysis of MB signals in ultrasound contrast imaging. Bayesian spectrum analysis offers a viable solution to overcome the limited frequency resolution achieved by the FT for MB scatterers. A typical MB signal sampled at 20 MHz and consisting of approximately 80 samples was investigated. The conventional frequency resolution for Fourier-based methods in this instance was 241 kHz. The Bayesian spectral estimation resulted in 12 distinct frequency components many of which were separated by less than 241 kHz. The smallest separation was 52 kHz. The resulting frequency and amplitude estimates matched relatively well with the Fast Fourier Transform (FFT)spectral peaks. Using these estimates the MB signal was reconstructed, and a correlation coefficient of approximately 0.99 was achieved between original and reconstructed signals. The result was reproduced in the analysis of a synthetic MB signal, similar to the original one, and all 12 frequencies were always resolved. Overall, the method promises high spectral resolution without sacrificing the temporal one, and provides information that may be used to differentiate the MB non-linear signal from that of linear scatterers.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Bayesian Spectrum Analysis of Non-Linear Ultrasound Contrast Microbubble Signals
The localization of individual contrast microbubbles (MBs)is key to the emerging field of super-resolution ultrasound. The Fourier Transform (FT)is typically used for the frequency domain analysis of MB signals in ultrasound contrast imaging. Bayesian spectrum analysis offers a viable solution to overcome the limited frequency resolution achieved by the FT for MB scatterers. A typical MB signal sampled at 20 MHz and consisting of approximately 80 samples was investigated. The conventional frequency resolution for Fourier-based methods in this instance was 241 kHz. The Bayesian spectral estimation resulted in 12 distinct frequency components many of which were separated by less than 241 kHz. The smallest separation was 52 kHz. The resulting frequency and amplitude estimates matched relatively well with the Fast Fourier Transform (FFT)spectral peaks. Using these estimates the MB signal was reconstructed, and a correlation coefficient of approximately 0.99 was achieved between original and reconstructed signals. The result was reproduced in the analysis of a synthetic MB signal, similar to the original one, and all 12 frequencies were always resolved. Overall, the method promises high spectral resolution without sacrificing the temporal one, and provides information that may be used to differentiate the MB non-linear signal from that of linear scatterers.
- Open Access
- 26 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 38 (1) , 194-204
Resolving Ultrasound Contrast Microbubbles Using Minimum Variance Beamforming
Minimum Variance (MV) beamforming is known to improve the lateral resolution of ultrasound images and enhance the separation of isolated point scatterers. This paper aims to evaluate the adaptive beamformer's performance with flowing microbubbles (MBs) which are relevant to super-resolution ultrasound imaging. Simulations using point scatterer data from single emissions were complemented by an experimental investigation performed using a capillary tube phantom and the Synthetic Aperture Real-time Ultrasound System (SARUS). The MV performance was assessed by the minimum distance that allows the display of two scatterers positioned side-by-side, the lateral Full-Width-at-Half-Maximum (FWHM), and the Peak-Sidelobe-Level (PSL). In the tube, scatterer responses separated by down to 196 μm (or 1.05λ) were distinguished by the MV method, while the standard Delay-And-Sum (DAS) beamformers were unable to achieve such separation. Up to ninefold FWHM decrease was also measured in favor of the MV beamformer for individual echoes from MBs. The lateral distance between two scatterers impacted on their FWHM value, and additional differences in the scatterers' axial or out-of-plane position also impacted on their size and appearance. The simulation and experimental results were in agreement in terms of lateral resolution. The point scatterer study showed that the proposed MV imaging scheme provided clear resolution benefits compared to DAS. Current super-resolution methods mainly depend on DAS beamformers. Instead, the use of the MV method may provide a larger number of detected, and potentially better localized, MB scatterers.
- 26 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 38 (1) , 194-204
Open AccessResolving Ultrasound Contrast Microbubbles Using Minimum Variance Beamforming
Minimum Variance (MV) beamforming is known to improve the lateral resolution of ultrasound images and enhance the separation of isolated point scatterers. This paper aims to evaluate the adaptive beamformer's performance with flowing microbubbles (MBs) which are relevant to super-resolution ultrasound imaging. Simulations using point scatterer data from single emissions were complemented by an experimental investigation performed using a capillary tube phantom and the Synthetic Aperture Real-time Ultrasound System (SARUS). The MV performance was assessed by the minimum distance that allows the display of two scatterers positioned side-by-side, the lateral Full-Width-at-Half-Maximum (FWHM), and the Peak-Sidelobe-Level (PSL). In the tube, scatterer responses separated by down to 196 μm (or 1.05λ) were distinguished by the MV method, while the standard Delay-And-Sum (DAS) beamformers were unable to achieve such separation. Up to ninefold FWHM decrease was also measured in favor of the MV beamformer for individual echoes from MBs. The lateral distance between two scatterers impacted on their FWHM value, and additional differences in the scatterers' axial or out-of-plane position also impacted on their size and appearance. The simulation and experimental results were in agreement in terms of lateral resolution. The point scatterer study showed that the proposed MV imaging scheme provided clear resolution benefits compared to DAS. Current super-resolution methods mainly depend on DAS beamformers. Instead, the use of the MV method may provide a larger number of detected, and potentially better localized, MB scatterers.
- Open Access
- 19 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 6, 14188-14203
Super-Resolved Ultrasound Echo Spectra With Simultaneous Localization Using Parametric Statistical Estimation
Ultrasound contrast imaging (UCI) aims to detect flow changes in the vascular bed that can help differentiate normal from diseased tissues thus providing an early screening tool for diagnosis or treatment monitoring. Ultrasound contrast agents (UCAs), used in UCI, are microbubbles that scatter ultrasound non-linearly. To date the signal processing research has successfully subtracted signals from the linear response of tissue (linear signals), but, in general, has not provided a sensitive detection that is specific to the UCA signal. This paper develops a method for the temporal and spectral estimation of linear and non-linear ultrasound echo signals. This technique is based on non-parametric methods for coarse estimation, followed by a parametric method within a Bayesian framework for estimation refinement. The results show that the pulse location can be estimated to within ±3 sample points accuracy for signals consisting of ≈80 sample points depending on the signal type, while the frequency content can be estimated to within 0.050 MHz deviations for frequencies in the 1 to 4 MHz range. This parametric spectral estimation achieved a 5-fold improvement in the frequency resolution compared with Fourier-based methods, and revealed previously unresolved frequency information that led to over 80% correct signal classification for linear and non-linear echo signals.
- 19 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 6, 14188-14203
Open AccessSuper-Resolved Ultrasound Echo Spectra With Simultaneous Localization Using Parametric Statistical Estimation
Ultrasound contrast imaging (UCI) aims to detect flow changes in the vascular bed that can help differentiate normal from diseased tissues thus providing an early screening tool for diagnosis or treatment monitoring. Ultrasound contrast agents (UCAs), used in UCI, are microbubbles that scatter ultrasound non-linearly. To date the signal processing research has successfully subtracted signals from the linear response of tissue (linear signals), but, in general, has not provided a sensitive detection that is specific to the UCA signal. This paper develops a method for the temporal and spectral estimation of linear and non-linear ultrasound echo signals. This technique is based on non-parametric methods for coarse estimation, followed by a parametric method within a Bayesian framework for estimation refinement. The results show that the pulse location can be estimated to within ±3 sample points accuracy for signals consisting of ≈80 sample points depending on the signal type, while the frequency content can be estimated to within 0.050 MHz deviations for frequencies in the 1 to 4 MHz range. This parametric spectral estimation achieved a 5-fold improvement in the frequency resolution compared with Fourier-based methods, and revealed previously unresolved frequency information that led to over 80% correct signal classification for linear and non-linear echo signals.
- Open Access
- 6 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 65 (8) , 1840-1851
Super-Resolution Axial Localization of Ultrasound Scatter Using Multi-Focal Imaging
Objective: This paper aims to develop a method for achieving micrometre axial scatterer localization for medical ultrasound, surpassing the inherent, pulse length dependence limiting ultrasound imaging. Methods: The method, directly translated from cellular microscopy, is based on multi-focal imaging and the simple, aberration dependent, image sharpness metric of a single point scatterer. The localization of a point scatterer relies on the generation of multiple overlapping sharpness curves, created by deploying three foci during receive processing, and by assessing the sharpness values after each acquisition as a function of depth. Each derived curve peaks around the receive focus and the unique position of the scatterer is identified by combining the data from all curves using a maximum likelihood algorithm with a calibration standard. Results: Simulated and experimental ultrasound point scatter data show that the sharpness method can provide scatterer axial localization with an average accuracy down to 10.21 μm ($\approx\lambda $/21) and with up to 11.4 times increased precision compared to conventional localization. The improvements depend on the rate of change of sharpness using each focus, and the signal to noise ratio in each image. Conclusion: Super-resolution axial imaging from optical microscopy has been successfully translated into ultrasound imaging by using raw ultrasound data and standard beamforming. Significance: The normalized sharpness method has the potential to be used in scatterer localization applications and contribute in current super-resolution ultrasound imaging techniques.
- 6 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 65 (8) , 1840-1851
Open AccessSuper-Resolution Axial Localization of Ultrasound Scatter Using Multi-Focal Imaging
Objective: This paper aims to develop a method for achieving micrometre axial scatterer localization for medical ultrasound, surpassing the inherent, pulse length dependence limiting ultrasound imaging. Methods: The method, directly translated from cellular microscopy, is based on multi-focal imaging and the simple, aberration dependent, image sharpness metric of a single point scatterer. The localization of a point scatterer relies on the generation of multiple overlapping sharpness curves, created by deploying three foci during receive processing, and by assessing the sharpness values after each acquisition as a function of depth. Each derived curve peaks around the receive focus and the unique position of the scatterer is identified by combining the data from all curves using a maximum likelihood algorithm with a calibration standard. Results: Simulated and experimental ultrasound point scatter data show that the sharpness method can provide scatterer axial localization with an average accuracy down to 10.21 μm ($\approx\lambda $/21) and with up to 11.4 times increased precision compared to conventional localization. The improvements depend on the rate of change of sharpness using each focus, and the signal to noise ratio in each image. Conclusion: Super-resolution axial imaging from optical microscopy has been successfully translated into ultrasound imaging by using raw ultrasound data and standard beamforming. Significance: The normalized sharpness method has the potential to be used in scatterer localization applications and contribute in current super-resolution ultrasound imaging techniques.
- Open Access
- 1 August 2017
- Published by Elsevier in Ultrasonics
- Vol. 79, 87-95
Experimental performance assessment of the sub-band minimum variance beamformer for ultrasound imaging
- 1 August 2017
- Published by Elsevier in Ultrasonics
- Vol. 79, 87-95
Open AccessExperimental performance assessment of the sub-band minimum variance beamformer for ultrasound imaging