Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xun Wu has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Deep-Learning-Based High-Intensity Focused Ultrasound Lesion Segmentation in Multi-Wavelength Photoacoustic Imaging

    by Xun Wu, Jean L. Sanders, M. Murat Dundar, Ömer Oralkan

    Photoacoustic (PA) imaging can be used to monitor high-intensity focused ultrasound (HIFU) therapies because ablation changes the optical absorption spectrum of the tissue, and this change can be detected with PA imaging. Multi-wavelength photoacoustic (MWPA) imaging makes this change easier to detect by repeating PA imaging at multiple optical wavelengths and sampling the optical absorption spectrum more thoroughly. Real-time pixel-wise classification in MWPA imaging can assist clinicians in monitoring HIFU lesion formation and will be a crucial milestone towards full HIFU therapy automation based on artificial intelligence. In this paper, we present a deep-learning-based approach to segment HIFU lesions in MWPA images. Ex vivo bovine tissue is ablated with HIFU and imaged via MWPA imaging. The acquired MWPA images are then used to train and test a convolutional neural network (CNN) for lesion segmentation. Traditional machine learning algorithms are also trained and tested to compare with the CNN, and the results show that the performance of the CNN significantly exceeds traditional machine learning algorithms. Feature selection is conducted to reduce the number of wavelengths to facilitate real-time implementation while retaining good segmentation performance. This study demonstrates the feasibility and high performance of the deep-learning-based lesion segmentation method in MWPA imaging to monitor HIFU lesion formation and the potential to implement this method in real time.


  • A Low-Power Wearable E-Nose System Based on a Capacitive Micromachined Ultrasonic Transducer (CMUT) Array for Indoor VOC Monitoring

    by Marzana Mantasha Mahmud, Chunkyun Seok, Xun Wu, Erdem Sennik, Ali Onder Biliroglu, Oluwafemi Joel Adelegan, Inhwan Kim, Jesse S. Jur, Feysel Yalcin Yamaner, Omer Oralkan

    Volatile organic compounds (VOCs) are pervasive in the environment and their real-time continuous monitoring can facilitate better understanding of their effects on human health by combining environmental factors with physiological conditions. The scope of wearable sensors for detection of VOCs is evident as the accuracy of the sensor prediction depends on its proximity to the VOC source along with the sensitivity and selectivity of the sensor itself. In this paper, we present a low-power wearable e-nose system based on a capacitive micromachined ultrasonic transducer (CMUT) array. CMUTs offer inherent benefits of excellent mass resolution, easy array fabrication, and integration with electronics, which make them an appropriate choice as a transducer element for gravimetric e-nose systems. A 5-channel CMUT sensor array was chemically functionalized and used for the detection of four volatiles, ethanol, toluene, p-xylene, and styrene. All the channels of the sensor array achieved a resolution below 10 ppm within 0.2–3% of OSHA-PEL time-weighted average (TWA) for each volatile. For each test cycle, the maximum frequency shift, the rate of adsorption, and the rate of desorption were extracted as features. Linear discriminant analysis (LDA) was applied to visualize the discrimination performance of the sensor array. The system performance was characterized using an automated testing system. The presented sensor system can be used for identification of volatiles with suitable pattern-recognition techniques.


  • Design and Fabrication of Wideband Air-Coupled Capacitive Micromachined Ultrasonic Transducers With Varying Width Annular-Ring and Spiral Cell Structures

    by Oluwafemi Joel Adelegan, Zachary A. Coutant, Xun Wu, Feysel Yalcin Yamaner, Omer Oralkan

    Air-coupled transducers with broad bandwidth are desired for many airborne applications, such as obstacle detection, haptic feedback, and flow metering. In this article, we present a design strategy and demonstrate a fabrication process for developing improved concentric annular- and novel spiral-shaped capacitive micromachined ultrasonic transducers (CMUTs) that can generate high output pressure and provide wide bandwidth in air. We explore the ability to implement complex geometries by photolithographic definition to improve the bandwidth of air-coupled CMUTs. The ring widths in the annular design were varied so that the device can be improved in terms of bandwidth when these rings resonate in parallel. Using the same ring width parameters for the spiral-shaped design but with a smoother transition between the ring widths along the spiral, the bandwidth of the spiral-shaped device is improved. With the reduced process complexity associated with the anodic-bonding-based fabrication process, a 25- μm vibrating silicon plate was bonded to a borosilicate glass wafer with up to 15- μm deep cavities. The fabricated devices show an atmospheric deflection profile that is in agreement with the FEM results to verify the vacuum sealing of the devices. The devices show a 3-dB fractional bandwidth (FBW) of 12% and 15% for spiral- and annular-shaped CMUTs, respectively. We measured a 127-dB sound pressure level at the surface of the transducers. The angular response of the fabricated CMUTs was also characterized. The results demonstrated in this article show the possibility of improving the bandwidth of air-coupled devices by exploring the flexibility in the design process associated with CMUT technology.


  • A Row-Column (RC) Addressed 2-D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array on a Glass Substrate

    by Jean L. Sanders, Ali Onder Biliroglu, Xun Wu, Oluwafemi J. Adelegan, Feysel Yalcin Yamaner, Omer Oralkan

    This article presents a row-column (RC) capacitive micromachined ultrasonic transducer (CMUT) array fabricated using anodic bonding on a borosilicate glass substrate. This is shown to reduce the bottom electrode-to-substrate capacitive coupling. This subsequently improves the relative response of the elements when top or bottom electrodes are used as the “signal” (active) electrode. This results in a more uniform performance for the two cases. Measured capacitance and resonant frequency, pulse-echo signal amplitude, and frequency response are presented to support this. Biasing configurations with varying ac and dc arrangements are applied and subsequently explored. Setting the net dc bias voltage across an off element to zero is found to be most effective to minimize spurious transmission. To achieve this, a custom switching circuit was designed and implemented. This circuit was also used to obtain orthogonal B-mode cross-sectional images of a rotationally asymmetric target.


  • An FPGA-Based Backend System for Intravascular Photoacoustic and Ultrasound Imaging

    by Xun Wu, Jean L. Sanders, Xiao Zhang, Feysel Yalcin Yamaner, Omer Oralkan

    The integration of intravascular ultrasound (IVUS) and intravascular photoacoustic (IVPA) imaging produces an imaging modality with high sensitivity and specificity which is particularly needed in interventional cardiology. Conventional side-looking IVUS imaging with a single-element ultrasound (US) transducer lacks forward-viewing capability, which limits the application of this imaging mode in intravascular intervention guidance, Doppler-based flow measurement, and visualization of nearly, or totally blocked arteries. For both side-looking and forward-looking imaging, the necessity to mechanically scan the US transducer limits the imaging frame rate, and therefore, array-based solutions are desired. In this paper, we present a low-cost, compact, high-speed, and programmable imaging system based on a field-programmable gate array suitable for dual-mode forward-looking IVUS/IVPA imaging. The system has 16 US transmit and receive channels and functions in multiple modes including interleaved photoacoustic (PA) and US imaging, hardware-based high-frame-rate US imaging, software-driven US imaging, and velocity measurement. The system is implemented in the register-transfer level, and the central system controller is implemented as a finite-state machine. The system was tested with a capacitive micromachined ultrasonic transducer array. A 170-frames-per-second (FPS) US imaging frame rate is achieved in the hardware-based high-frame-rate US imaging mode while the interleaved PA and US imaging mode operates at a 60-FPS US and a laser-limited 20-FPS PA imaging frame rate. The performance of the system benefits from the flexibility and efficiency provided by the low-level implementation. The resulting system provides a convenient backend platform for research and clinical IVPA and IVUS imaging.


  • A Row-Column (RC) Addressed 2D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array on a Glass Substrate: Preliminary Results

    by Jean L. Sanders, Xun Wu, Oluwafemi J. Adelegan, Marzana M. Mahmud, F. Yalcin Yamaner, Caterina M. Gallippi, Omer Oralkan

    In this work, we present preliminary characterization results from a 32 x 32 row-column (RC) addressed 2D capacitive micromachined ultrasonic transducer (CMUT) array. The device was fabricated using anodic bonding on a borosilicate glass substrate, which eliminates the substrate - bottom electrode coupling previously observed in traditional CMUT RC arrays fabricated on silicon substrates. The characterization results were compared for the top and bottom electrodes and include impedance measurements, pulseecho impulse responses, and 2D scans of the pressure field using a calibrated hydrophone. The results showed that the array elements behave similarly when ground and hot electrodes were switched between the top and bottom electrodes for all of the measured parameters including device capacitance, center frequency, and pulse-echo response amplitude. The pressure scans verified the highly customizable nature of RC arrays by showing multiple active element configurations. A sample cross-sectional image of a metal target was also demonstrated.


  • A front-end integrated circuit for a 2D capacitive micromachined ultrasound transducer (CMUT) array for a noninvasive neural interface to the retina

    by Chunkyun Seok, Xun Wu, F. Yalcin Yamaner, Omer Oralkan

    A recent study showed that focused ultrasound can noninvasively create neural response in the retina in a similar way to light stimulus. To implement such functionality, we developed an algorithm for a 2D transducer array to project an image to the retina as an ultrasound field pattern (USFP) in a previous study. In this work, we report a front-end integrated circuit (IC) for a 2D CMUT array that realizes a USFP with quantized phases and amplitudes. In addition, we evaluated the projected image quality with Field II simulations considering non-linearity in phases extracted from a fabricated prototype chip.

  • A handheld 1D transparent CMUT array probe for photoacoustic imaging

    by Jean L. Sanders, Xiao Zhang, Xun Wu, Oluwafemi Joel Adelegan, F. Yalcin Yamaner, Michael Kudenov, Omer Oralkan

    A transparent transducer array is desired in backward-mode photoacoustic imaging (PAI). CMUT technology is especially suitable for this application because of its wide bandwidth and a wide selection of processing materials. We have previously demonstrated a single-element CMUT with an ITO bottom electrode for improved transparency. The device showed 40% to 70% optical transmission from 700 nm to 900 nm, which is the wavelength range commonly used for in-vivo PAI. In this work, we will make a 1D PAI probe that integrates a fully packaged 1D CMUT array with improved transparency, a fiber bundle, in-probe optics, and low-noise amplifiers which will interface with a real-time imaging system.


  • A handheld 1D transparent CMUT array probe for photoacoustic imaging: Preliminary results

    by Jean L. Sanders, Xiao Zhang, Xun Wu, Oluwafemi Joel Adelegan, F. Yalcin Yamaner, Michael Kudenov, Omer Oralkan

    A transparent transducer array is desired in backward-mode photoacoustic imaging (PAI). CMUT technology is especially suitable for this application because of its wide bandwidth and a wide selection of processing materials. We have previously demonstrated a single-element CMUT with an ITO bottom electrode for improved transparency. The device showed 40% to 70% optical transmission from 700 nm to 900 nm, which is the wavelength range commonly used for in-vivo PAI. In this work, we present a 1D PAI probe that integrates a 1D CMUT array, a fiber bundle, in-probe optics, and low-noise amplifiers which interface with a real-time imaging system. We also demonstrate the PAI capability of a single transparent CMUT element. In this experiment, the phantom was a polyethylene tube filled with indocyanine green (ICG) solution embedded in a tissue-mimicking material. In this setup, the light introduced from the back side of the CMUT enabled direct illumination of the imaging field. We are currently developing 1D arrays for use in PAI with high Vis-NIR transmission. As a proof of principle, we built a 128-channel handheld probe which integrates light from the back side and allows for in-probe front-end amplifiers. The center of the probe houses a compact optical design for the illuminator based on cylindrical lenses. The probe electronics consists of two printed circuit boards, each with 64 channels of low-noise amplifiers with integrated transmit/receive switching and biasing circuitry. This handheld probe has been used in initial tests with a standard nontransparent 1D CMUT array to show the basic electrical functionality.