    Fault Detection in Axial Deformation Sensors for Hydraulic Turbine Head-Cover Fastening Bolts Using Analytical Redundancy

    by Eddy Yujra Rivas, Alexander Vyacheslavov, Kirill Gogolinskiy, Kseniia Sapozhnikova, Roald Taymanov

    This study proposes an analytical redundancy method that combines empirical models with a Kalman filter to ensure the reliability of measurements from axial deformation sensors in a turbine head-cover bolt-monitoring system. This integration enables the development of predictive models that optimally estimate the dynamic deformation of each bolt during turbine operation at full and partial load. The test results of the models under conditions of outliers, measurement noise, and changes in turbine operating mode, evaluated using accuracy and sensitivity metrics, confirmed their high accuracy (Acc ≈ 0.146 µm) and robustness (SA < 0.001). The evaluation of the models’ responses to simulated sensor faults (offset, drift, precision degradation, stuck-at) revealed characteristic residual patterns for faults with magnitudes > 5 µm. These findings establish the foundation for developing a fault detection and isolation algorithm for continuous monitoring of these sensors’ operational health. For practical implementation, the models require validation across all operational modes, and maximum admissible deformation thresholds must be defined.


  • Open Access

    Deformation Monitoring Systems for Hydroturbine Head-Cover Fastening Bolts in Hydroelectric Power Plants

    by Eddy Yujra Rivas, Alexander Vyacheslavov, Kirill V. Gogolinskiy, Kseniia Sapozhnikova, Roald Taymanov

    This study investigates the reliability of Francis turbines and highlights the critical need for an improved deformation monitoring system for bolts that fasten a hydroturbine head-cover to its casing. During different operational stages of the hydraulic unit, such as start-up, partial load, and full load, the hydroturbine head-cover and its fastening bolts are subjected to static and cyclic loads. The loads generate vibrations and different deformations that must be monitored. Although various measuring instruments, such as vibration sensors and accelerometers, have been developed to monitor hydroturbine vibrations, only two systems—KM-Delta-8-CM and PTK KM-Delta—are currently applied to measure fastening bolt deformation. Furthermore, only one system, SKDS-SISH, was found to monitor the forces inducing this deformation. After analysis, it is evident that the described systems for monitoring the deformation of the fastening bolts do not guarantee the trustworthiness of the measuring sensors and there is a need for their improvement. The implementation of a self-checking function (including metrological features), the development of a digital twin of the sensor, and the application of technologies based on artificial intelligence could solve this problem.


  • Development of a Technique for Analysis of Tungsten-Containing Sludge Using Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES)

    by A. V. Vyacheslavov, V. V. Tsepkova, A. D. Titova, D. S. Rybin, T. N. Ermolaeva

    A technique for analysis of secondary tungsten-containing raw materials (tungsten-containing sludge) using inductively coupled plasma atomic emission spectrometry in combination with microwave autoclave sample preparation has been developed. The composition of the acid mixture and algorithm of microwave heating of the autoclave are chosen to provide a complete quantitative transfer of the sample into a convenient analytical form for subsequent ICP-AES determination of the main components (heating of the sample to 220°C in the acid mixture of NH4F, HNO3, and HCl provides a quantitative transfer of its components to be determined into the solution). Analytical lines free from spectral interference were selected to determine Ti, Cr, Fe, Co, Ni, and W. We used real industrial samples of secondary raw materials obtained in product manufacture from VK-type hard alloys [solid solution of tungsten carbide grains (WC phase) in cobalt (Co phase)] in the form of tungsten-containing powders, grinding sludge of solid sintered alloys, dust waste, defective mixtures, waste of ventilation systems, and carbide powders. Correctness of the determination of elements was proved in analysis of ferrotungsten standard samples upon determination of the matrix component (tungsten) and by the methods of additives and sample weight variation upon determination of the alloying elements and impurities. The method of internal standard (with Sc as the element of comparison) was used to improve the precision and accuracy of the tungsten determination. The relative standard deviation was thus reduced from 0.03 to 0.004. The developed precise rapid technique was tested in analysis of industrial samples of secondary tungsten-containing sludge of hard alloys. The technique is recommended to control the composition of the secondary tungsten-containing sludge of hard alloys in a wide range of concentrations.


  • Analysis of Corrosion-Resistant Ruthenium-Doped Titanium Alloys by Inductively Coupled Plasma Atomic Emission Spectroscopy

    by A. V. Vyacheslavov, Yu. Yu. Malinkina, V. B. Bichaev, A. D. Titova, T. N. Ermolaeva

    A technique for analyzing new corrosion-resistant ruthenium-doped titanium alloys using inductively coupled plasma atomic emission spectrometry (ICP-AES) with microwave sample preparation is reported. The composition of a mixture of acids and the temperature and time parameters of sample preparation of titanium alloys under microwave heating in an autoclave ensuring quantitative conversion of the sample into a convenient analytical form without loss of volatile components for subsequent ICP-AES analysis are substantiated. Optimal conditions for the excitation of the analytical signal have been found, and analytical lines of elements without spectral noise have been selected. Samples of experimental melts of industrial titanium alloys of various classes, volumetrically doped with ruthenium, which are under development and are not yet commercially produced in the Russian Federation (alloy PT-7M + Ru, PT-3B + Ru, 5B + Ru, 37 + Ru, VT-22 + Ru) have been studied. The alloy samples contained the following alloying elements (wt %): Al (1.8–6.3); V (1.0–5.5); Mo (0.7–5.5); Zr (0.2–3.0); Cr (0.5–1.5); Fe (0.5–1.5); Ru (0.05–0.15). The correctness of the determination of alloying elements has been confirmed by analyzing standard samples by varying their mass and, in the case of ruthenium, by the “introduced–found” method. The developed method significantly reduces the time of analysis by combining the multielement ICP-AES method with microwave sample preparation, expands the list of detectable elements in titanium alloys, and improves the precision of the results of analysis.


  • ICP-AES Analysis of Secondary Tungsten-Containing Raw Materials for Production of Hard Alloys

    by A. V. Vyacheslavov, V. B. Bichaev, A. D. Titova, D. S. Rybin, T. N. Ermolaeva

    A method for ICP-AES determination of Ti, V, Cr, Fe, Co, Ni, Cu, Zn, and Ta in recycled cemented tungsten carbide is developed including preliminary microwave sample decomposition in a steam...


  • Analysis of surfacing materials from cast carbide alloys using inductively coupled plasma atomic emission spectrometry (ICP-AES)

    by A. V. Vyacheslavov, V. V. Tsepkova, A. D. Titova, T. N. Ermolaeva

    A technique for analysis of surfacing materials (cast cobalt-based carbide alloys) using by ICP-AES in combination with microwave autoclave sample preparation is developed. Composition of the acid mixture, temperature and time parameters of the sample preparation under microwave heating in an autoclave are specified, thus ensuring complete quantitative transfer of the sample into a convenient analytical form without losses of volatile components for the subsequent ICP-AES analysis. Analytic lines of the elements free from spectral interference were chosen to determine all the rated components in the casting materials from cast carbide alloys. Study of surfacing materials was carried out using alloys Pr-B3K-PrH-U10Kh63B5, Pr-B3K-P-PrN-U20Kh57B10 and TsN-2-E-190K62X29B5C2, containing the alloying elements (% wt.): Co (up to 65); Cr (28.0 – 32.0); W (4.0 – 11.0); Si (1.0 to 3.0); C (1.0 – 2.0); Ni (0.1 – 2.0); Mn (0.3 – 0.6) and Fe (up to 2.0). The correctness of determining rated element was confirmed in analysis of standard samples using sample weight variation. The developed technique was tested on industrial prototypes of surfacing materials made of cobalt-based cast carbide alloys of tested grades. The method is rapid (11-fold reduction in the time of analysis) and reagent-saving (by 12.5 times) procedure compared to single-element methods by 11 times and reduction of the volume of applied reagents. Combination of the multielement ICP-AES method with microwave sample preparation provides an increase in the accuracy of Si, Cr, Mn, Fe, Ni, and W determination in surfacing materials of cast carbide alloys within a range of rated concentrations.

  • ANALYSIS OF CORROSION-RESISTANT TITANIUM ALLOYS DOPED WITH RUTHENIUM BY ICP-AES

    by A. V. Vyacheslavov, Yu. Yu. Malinkina, V. B. Bichaev, A. D. Titova, T. N. Ermolaeva

    Представлена методика анализа новых коррозионно-стойких титановых сплавов, легированных рутением, методом атомно-эмиссионной спектрометрии с индуктивно-связанной плазмой (АЭС ИСП), включающая микроволновую подготовку пробы. Обоснованы состав кислотной смеси и температурно-временные параметры пробоподготовки титановых сплавов в условиях микроволнового нагрева в автоклаве, обеспечивающие количественное переведение пробы в удобную аналитическую форму без потерь летучих компонентов для последующего АЭС-ИСП анализа. Найдены оптимальные условия возбуждения аналитического сигнала, выбраны аналитические линии элементов, свободные от спектральных помех. Исследовали образцы опытных плавок промышленных титановых сплавов различных классов, объемно легированные рутением, которые находятся в стадии разработки и в РФ промышленно пока не выпускаются (марки сплавов ПТ-7М+Ru, ПТ-3В+Ru, 5В+Ru, 37+Ru, ВТ-22+Ru). Образцы сплавов содержали следующие легирующие элементы (% масс.): Al (1,8 – 6,3); V (1,0 – 5,5); Mo (0,7 – 5,5); Zr (0,2 – 3,0); Cr (0,5 – 1,5); Fe (0,5 – 1,5); Ru (0,05 – 0,15). Правильность определения легирующих элементов подтверждали путем анализа стандартных образцов методом варьирования навески, а в случае рутения — методом «введено – найдено». Разработанная методика позволяет существенно сократить продолжительность анализа за счет сочетания многоэлементного метода АЭС-ИСП с микроволновой пробоподготовкой, расширить перечень определяемых элементов в титановых сплавах и повысить прецизионность результатов анализа.


  • AES-ISP Analysis of Secondary Tungsten-Containing Raw Materials for Production of Hard Alloys

    by A. V. Vyacheslavov, V. B. Bichaev, A. D. Titova, D. S. Rybin, T. N. Ermolaeva, Saint Peterburg Virial Ltd

    Заводская лаборатория. Диагностика материалов