Cedar I. Urwyler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cedar I. Urwyler has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Vijay Viswam
Department of Biosystems Science and Engineering, ETH Zurich, Basel, Switzerland
2 shared publications - Amir Shadmani
Bio Engineering Laboratory, Department of Biosystems Science and Engineering, ETH Zurich, Basel 4058, Switzerland
1 shared publication - Andreas Hierlemann
Department of Biosystems Science and Engineering, ETH Zurich, Basel, Switzerland
1 shared publication Andreas R. Hierlemann
ETH Zürich, D-BSSE, Switzerland
1 shared publication- Jan Muller
Department of Biosystems Science and Engineering, ETH Zurich, Basel, Switzerland
1 shared publication - Jelena Dragas
Department of Health Sciences and Technology, ETH Zürich, Zürich, Switzerland
1 shared publication
Latest Publications
- 11 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (6) , 1356-1368
Impedance Spectroscopy and Electrophysiological Imaging of Cells With a High-Density CMOS Microelectrode Array System
A monolithic multi-functional CMOS microelectrode array system was developed that enables label-free electrochemical impedance spectroscopy of cells in vitro at high spatiotemporal resolution. The electrode array includes 59,760 platinum microelectrodes, densely packed within a 4.5 mm × 2.5 mm sensing region at a pitch of 13.5 μm. A total of 32 on-chip lock-in amplifiers can be used to measure the impedance of any arbitrarily chosen subset of electrodes in the array. A sinusoidal voltage, generated by an on-chip waveform generator with a frequency range from 1 Hz to 1 MHz, was applied to the reference electrode. The sensing currents through the selected recording electrodes were amplified, demodulated, filtered, and digitized to obtain the magnitude and phase information of the respective impedances. The circuitry consumes only 412 μW at 3.3 V supply voltage and occupies only 0.1 mm 2 , for each channel. The system also included 2048 extracellular action-potential recording channels on the same chip. Proof of concept measurements of electrical impedance imaging and electrophysiology recording of cardiac cells and brain slices are demonstrated in this paper. Optical and impedance images showed a strong correlation.
- 11 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (6) , 1356-1368
Impedance Spectroscopy and Electrophysiological Imaging of Cells With a High-Density CMOS Microelectrode Array System
A monolithic multi-functional CMOS microelectrode array system was developed that enables label-free electrochemical impedance spectroscopy of cells in vitro at high spatiotemporal resolution. The electrode array includes 59,760 platinum microelectrodes, densely packed within a 4.5 mm × 2.5 mm sensing region at a pitch of 13.5 μm. A total of 32 on-chip lock-in amplifiers can be used to measure the impedance of any arbitrarily chosen subset of electrodes in the array. A sinusoidal voltage, generated by an on-chip waveform generator with a frequency range from 1 Hz to 1 MHz, was applied to the reference electrode. The sensing currents through the selected recording electrodes were amplified, demodulated, filtered, and digitized to obtain the magnitude and phase information of the respective impedances. The circuitry consumes only 412 μW at 3.3 V supply voltage and occupies only 0.1 mm 2 , for each channel. The system also included 2048 extracellular action-potential recording channels on the same chip. Proof of concept measurements of electrical impedance imaging and electrophysiology recording of cardiac cells and brain slices are demonstrated in this paper. Optical and impedance images showed a strong correlation.
- Open Access
- 1 January 2018
- Published by Frontiers Media SA in Frontiers in Cellular Neuroscience
- Vol. 12
Electrical Impedance Tomography on High-density Microelectrode Arrays
Electrical impedance tomography (EIT) is a non-invasive, label-free imaging technique that enables to reconstruct the conductivity distribution in a body from a series of impedance measurements. Impedance measurements can be used to determine the position, morphology, and growth of cells or tissues, as well as pathological signs, e.g., precancerous tissue conditions (Gersing 1999). The newest high-density microelectrode array (MEA) system developed in our group features 59,760 integrated electrodes (Dragas et al. 2017). The chip features a variety of electrophysiological functions: Action-potential recording (2048 channels), cyclic voltammetry (28 channels), local-field-potential recording (32 channels) and extracellular stimulation (16 channels) [Fig 1A]. The chip can also measure impedance through 32 channels, which enables EIT measurements. We were able to establish a proof of concept for EIT (Viswam et al. 2017). The current goal of this project is to develop an impedance measurement protocol and an appropriate reconstruction algorithm that allow for single-cell-resolution impedance imaging. Material and Methods An acute slice of mouse brain was placed on the array within a well containing carbogen-bubbled calcium-free artificial cerebrospinal fluid. A sinusoidal voltage, generated with the chip’s built-in wave generator was applied to the reference electrode, and the induced current was sensed with the MEA electrodes. Using 120 configurations of 3840 sparsely configured electrodes, an impedance map was measured. The raw data, containing the magnitude and phase of the measured signals was then processed in Matlab using a custom-made code. We are currently working on an alternate impedance measurement protocol, where selected electrodes in the array are used for the input signal, and the induced currents are then measured in adjacent electrodes [Fig. 1B]. By rapidly changing electrode configurations, a scan of the region of interest can be obtained. Results By creating an impedance magnitude heat map of the tissue, we established a proof of concept for EIT measurements with our chip. Discussion As a pixel of the array is 13.5 µm x 13.5 µm, it should be possible to improve the resolution down to single cell level, which enables exact localization of cells on the array. This is the focus of our ongoing work. After establishing a suitable electrode configuration sequence, we will develop a reconstruction code, drawing on the material available through the Electrical Impedance and Diffuse Optical Reconstruction Software project (Adler et al. 2017).
- 1 January 2018
- Published by Frontiers Media SA in Frontiers in Cellular Neuroscience
- Vol. 12
Open AccessElectrical Impedance Tomography on High-density Microelectrode Arrays
Electrical impedance tomography (EIT) is a non-invasive, label-free imaging technique that enables to reconstruct the conductivity distribution in a body from a series of impedance measurements. Impedance measurements can be used to determine the position, morphology, and growth of cells or tissues, as well as pathological signs, e.g., precancerous tissue conditions (Gersing 1999). The newest high-density microelectrode array (MEA) system developed in our group features 59,760 integrated electrodes (Dragas et al. 2017). The chip features a variety of electrophysiological functions: Action-potential recording (2048 channels), cyclic voltammetry (28 channels), local-field-potential recording (32 channels) and extracellular stimulation (16 channels) [Fig 1A]. The chip can also measure impedance through 32 channels, which enables EIT measurements. We were able to establish a proof of concept for EIT (Viswam et al. 2017). The current goal of this project is to develop an impedance measurement protocol and an appropriate reconstruction algorithm that allow for single-cell-resolution impedance imaging. Material and Methods An acute slice of mouse brain was placed on the array within a well containing carbogen-bubbled calcium-free artificial cerebrospinal fluid. A sinusoidal voltage, generated with the chip’s built-in wave generator was applied to the reference electrode, and the induced current was sensed with the MEA electrodes. Using 120 configurations of 3840 sparsely configured electrodes, an impedance map was measured. The raw data, containing the magnitude and phase of the measured signals was then processed in Matlab using a custom-made code. We are currently working on an alternate impedance measurement protocol, where selected electrodes in the array are used for the input signal, and the induced currents are then measured in adjacent electrodes [Fig. 1B]. By rapidly changing electrode configurations, a scan of the region of interest can be obtained. Results By creating an impedance magnitude heat map of the tissue, we established a proof of concept for EIT measurements with our chip. Discussion As a pixel of the array is 13.5 µm x 13.5 µm, it should be possible to improve the resolution down to single cell level, which enables exact localization of cells on the array. This is the focus of our ongoing work. After establishing a suitable electrode configuration sequence, we will develop a reconstruction code, drawing on the material available through the Electrical Impedance and Diffuse Optical Reconstruction Software project (Adler et al. 2017).