Kyeongha Kwon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kyeongha Kwon has a total of 358 co-authors. Here are the top co-authors by number of shared publications:
- John Allen Rogers
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, 60208, USA
16 shared publications - Yonggang Huang
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
11 shared publications - Yoonseok Park
Department of Materials Science and Engineering, Kyung Hee University, Yongin 17104, Republic of Korea
9 shared publications Jong Uk Kim
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, USA
7 shared publications- Hokyung Jang
Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, USA
6 shared publications - Hyoyoung Jeong
Department of Electrical and Computer Engineering, University of California, CA, USA
6 shared publications
Latest Publications
- Open Access
- 29 September 2026
- Published by Springer Nature in Research Square
On the limits and opportunities of AI reviewers: Reviewing the reviews of Nature-family papers with 45 expert scientists
As AI capabilities advance, AI reviewers (agents that read a manuscript and produce a referee report) are beginning to be deployed in scientific peer review. Yet, their credibility remains in question: many scientists think that they cannot judge scientific validity, while others are more optimistic about their readiness. In this work, we conduct a study in which 45 scientists in Physical, Biological, and Health Sciences spend 469 hours rating 2,960 individual criticisms (each targeting one aspect of a paper) from human-written and AI-generated reviews of 82 Nature-family papers, scoring each on correctness, significance, and evidence sufficiency. On a composite rating of reviews across all three dimensions, an AI reviewer powered by GPT-5.2 scores above each paper's top-rated human reviewer (60.0% vs 48.2% of criticisms, p=0.009). Also, AI reviewers' correct criticisms are more often rated significant, and surface a distinct 26% of legitimate issues that no human raises. However, AI reviewers are more often incorrect, overlap with each other far more than humans do with each other, and exhibit 16 weaknesses rare in human reviews. Overall, our results position current AI reviewers as complements to, not substitutes for, human reviewers.
- 29 September 2026
- Published by Springer Nature in Research Square
Open AccessOn the limits and opportunities of AI reviewers: Reviewing the reviews of Nature-family papers with 45 expert scientists
As AI capabilities advance, AI reviewers (agents that read a manuscript and produce a referee report) are beginning to be deployed in scientific peer review. Yet, their credibility remains in question: many scientists think that they cannot judge scientific validity, while others are more optimistic about their readiness. In this work, we conduct a study in which 45 scientists in Physical, Biological, and Health Sciences spend 469 hours rating 2,960 individual criticisms (each targeting one aspect of a paper) from human-written and AI-generated reviews of 82 Nature-family papers, scoring each on correctness, significance, and evidence sufficiency. On a composite rating of reviews across all three dimensions, an AI reviewer powered by GPT-5.2 scores above each paper's top-rated human reviewer (60.0% vs 48.2% of criticisms, p=0.009). Also, AI reviewers' correct criticisms are more often rated significant, and surface a distinct 26% of legitimate issues that no human raises. However, AI reviewers are more often incorrect, overlap with each other far more than humans do with each other, and exhibit 16 weaknesses rare in human reviews. Overall, our results position current AI reviewers as complements to, not substitutes for, human reviewers.
- Open Access
- 18 September 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (38)
A compact, wireless fluorimeter system for continuous, real-time monitoring of tissue perfusion via in vivo fluorescence signals
In vivo fluorescence signals provide physiological and pathological insights for the interpretation of biological states associated with anatomical abnormalities or disease. Conventional methods for measuring fluorescence signals rely on bulky, costly instrumentation for imaging or for localized sensing. Here, we report a compact, wireless fluorimeter system for continuous, real-time measurements of the dynamics of fluorescence signals at locations of interest across the body. The approach represents a type of wearable that enables quantitative, interpretable fluorescence readouts and automatic data streaming to standard smart devices. The platform is compatible with injectable fluorescent species of medical relevance, such as indocyanine green, fluorescein, and methylene blue. Measurements from ischemic rodent and healthy porcine models, as well as those associated with limb amputation/replantation studies in rodents, demonstrate physiologically meaningful fluorescence profiles, with validation against ex situ blood analysis. These conceptual and technical advances offer the potential for convenient, continuous monitoring of fluorescence signals to support disease management and long-term patient care.
- 18 September 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (38)
Open AccessA compact, wireless fluorimeter system for continuous, real-time monitoring of tissue perfusion via in vivo fluorescence signals
In vivo fluorescence signals provide physiological and pathological insights for the interpretation of biological states associated with anatomical abnormalities or disease. Conventional methods for measuring fluorescence signals rely on bulky, costly instrumentation for imaging or for localized sensing. Here, we report a compact, wireless fluorimeter system for continuous, real-time measurements of the dynamics of fluorescence signals at locations of interest across the body. The approach represents a type of wearable that enables quantitative, interpretable fluorescence readouts and automatic data streaming to standard smart devices. The platform is compatible with injectable fluorescent species of medical relevance, such as indocyanine green, fluorescein, and methylene blue. Measurements from ischemic rodent and healthy porcine models, as well as those associated with limb amputation/replantation studies in rodents, demonstrate physiologically meaningful fluorescence profiles, with validation against ex situ blood analysis. These conceptual and technical advances offer the potential for convenient, continuous monitoring of fluorescence signals to support disease management and long-term patient care.
- 10 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 9523112
Fast and Accurate Lithium-Ion Battery Impedance Measurement Using Multirate Quadrature Demodulation With Bandpass Filtering
Electrochemical impedance spectroscopy (EIS) is a noninvasive tool for characterizing battery states based on impedance across a specific frequency range. High-capacity lithium-ion batteries in electric vehicles demands impedance measurements within a sub-mΩ resolution. While EIS systems widely adopt quadrature demodulation for its accuracy, it suffers from long settling time and high hardware complexity, limiting integration feasibility. This work presents a novel multi-rate quadrature demodulation scheme with complex band-pass filtering that simultaneously reduces measurement time and implementation costs while maintaining high precision. The proposed EIS system employs multiple spur suppression stages where complex band-pass filters (BPFs) suppress DC offset and image tones, enabling subsequent low-pass filters (LPFs) to operate with wider cut-off frequency. Multi-rate signal processing using two distinct decimation stages enables adaptive LPF control, optimizing settling time across 100m-to-1k Hz frequency range. Compared to multi-rate architecture without complex BPF, the proposed approach achieves a 66% and 67% reduction in the impedance measurement time over the frequency range of 100m-to-1k Hz and at the lower bound (100 mHz), respectively. Compared to prior single-rate architectures requiring multiple LPF pairs, this approach achieves 32% faster measurement over the overlapping frequency range of 1-to-1k Hz while requiring 26% fewer hardware resources (ALUTs, registers, and DSPs) through a single BPF coefficient set and single infinite-impulse response LPF pair to cover the entire frequency range. Measurement repeatability shows standard deviation below 1.6 μΩ for known resistors (100 μΩ and 1 mΩ). The system is compared with a commercial electrochemical workstation for a high-capacity battery (70 Ah) across a 20-80% state-of-charge range at 0-45°C temperature.
- 10 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 9523112
Fast and Accurate Lithium-Ion Battery Impedance Measurement Using Multirate Quadrature Demodulation With Bandpass Filtering
Electrochemical impedance spectroscopy (EIS) is a noninvasive tool for characterizing battery states based on impedance across a specific frequency range. High-capacity lithium-ion batteries in electric vehicles demands impedance measurements within a sub-mΩ resolution. While EIS systems widely adopt quadrature demodulation for its accuracy, it suffers from long settling time and high hardware complexity, limiting integration feasibility. This work presents a novel multi-rate quadrature demodulation scheme with complex band-pass filtering that simultaneously reduces measurement time and implementation costs while maintaining high precision. The proposed EIS system employs multiple spur suppression stages where complex band-pass filters (BPFs) suppress DC offset and image tones, enabling subsequent low-pass filters (LPFs) to operate with wider cut-off frequency. Multi-rate signal processing using two distinct decimation stages enables adaptive LPF control, optimizing settling time across 100m-to-1k Hz frequency range. Compared to multi-rate architecture without complex BPF, the proposed approach achieves a 66% and 67% reduction in the impedance measurement time over the frequency range of 100m-to-1k Hz and at the lower bound (100 mHz), respectively. Compared to prior single-rate architectures requiring multiple LPF pairs, this approach achieves 32% faster measurement over the overlapping frequency range of 1-to-1k Hz while requiring 26% fewer hardware resources (ALUTs, registers, and DSPs) through a single BPF coefficient set and single infinite-impulse response LPF pair to cover the entire frequency range. Measurement repeatability shows standard deviation below 1.6 μΩ for known resistors (100 μΩ and 1 mΩ). The system is compared with a commercial electrochemical workstation for a high-capacity battery (70 Ah) across a 20-80% state-of-charge range at 0-45°C temperature.
- Open Access
- 6 February 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (6) , eaea8902
Deep learning–integrated multilayer thermal gradient sensing platform for real-time blood flow monitoring
Blood flow monitoring is fundamental for assessing cardiovascular health and identifying vascular complications. Traditional Doppler ultrasound methods require bulky equipment and specialized expertise, while recent thermal sensing approaches face limitations due to blood vessel depth variability beneath the skin. We present a soft electronic platform that integrates multilayer thermal sensing with deep learning algorithms to simultaneously measure blood flow rate and vessel depth. The device uses a wireless system with thermal sensing modules, featuring strategically positioned thermistors in separate layers to capture thermal gradients at different heights from the skin surface. Deep learning processes multilayer thermal patterns to extract both parameters in real time. Validation through benchtop testing, finite element analysis, and on-body trials demonstrates accurate measurements across relevant flow rates and vessel depths. Integration with photoplethysmography enhances continuous blood pressure monitoring accuracy compared to conventional approaches, particularly during dynamic physiological changes. This technology offers potential for personalized cardiovascular monitoring, early detection of hemodynamic events, and skin graft surveillance.
- 6 February 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (6) , eaea8902
Open AccessDeep learning–integrated multilayer thermal gradient sensing platform for real-time blood flow monitoring
Blood flow monitoring is fundamental for assessing cardiovascular health and identifying vascular complications. Traditional Doppler ultrasound methods require bulky equipment and specialized expertise, while recent thermal sensing approaches face limitations due to blood vessel depth variability beneath the skin. We present a soft electronic platform that integrates multilayer thermal sensing with deep learning algorithms to simultaneously measure blood flow rate and vessel depth. The device uses a wireless system with thermal sensing modules, featuring strategically positioned thermistors in separate layers to capture thermal gradients at different heights from the skin surface. Deep learning processes multilayer thermal patterns to extract both parameters in real time. Validation through benchtop testing, finite element analysis, and on-body trials demonstrates accurate measurements across relevant flow rates and vessel depths. Integration with photoplethysmography enhances continuous blood pressure monitoring accuracy compared to conventional approaches, particularly during dynamic physiological changes. This technology offers potential for personalized cardiovascular monitoring, early detection of hemodynamic events, and skin graft surveillance.
- 8 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 73 (3) , 1721-1730
Digitally Self-Calibrated RC Oscillator Utilizing Farey Search Algorithm Under ASIL-D Conditions Within AEC-Q100 Grade 0 Temperature Range
High-safety automotive applications demand extensive trimming over a wide temperature range due to AEC-Q100 Grade 0 and ASIL-D requirements. To mitigate the trimming burden, this paper introduces a digitally self-calibrated RC oscillator (RCO) leveraging the Farey search algorithm (FSA) coupled with a fractional current-steering DAC (FIDAC) and a loop break (LB). The FIDAC generates denser trimming currents in a reduced area, while the FSA optimizes the FIDAC settings. The dynamic LB ensures the connection between the RCO and its reference during calibration phases, and isolation during normal operational states for cross-validation. The prototype RCO fabricated in 180nm CMOS process achieves 0.55% $3\sigma $ -inaccuracy (280 samples) for process variations and 0.56% $3\sigma $ -inaccuracy (56 samples) across −40°C to 150°C, meeting the AEC-Q100 Grade 0 temperature range requirement without manual trimming and fulfilling the ASIL-D isolation criteria.
- 8 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 73 (3) , 1721-1730
Digitally Self-Calibrated RC Oscillator Utilizing Farey Search Algorithm Under ASIL-D Conditions Within AEC-Q100 Grade 0 Temperature Range
High-safety automotive applications demand extensive trimming over a wide temperature range due to AEC-Q100 Grade 0 and ASIL-D requirements. To mitigate the trimming burden, this paper introduces a digitally self-calibrated RC oscillator (RCO) leveraging the Farey search algorithm (FSA) coupled with a fractional current-steering DAC (FIDAC) and a loop break (LB). The FIDAC generates denser trimming currents in a reduced area, while the FSA optimizes the FIDAC settings. The dynamic LB ensures the connection between the RCO and its reference during calibration phases, and isolation during normal operational states for cross-validation. The prototype RCO fabricated in 180nm CMOS process achieves 0.55% $3\sigma $ -inaccuracy (280 samples) for process variations and 0.56% $3\sigma $ -inaccuracy (56 samples) across −40°C to 150°C, meeting the AEC-Q100 Grade 0 temperature range requirement without manual trimming and fulfilling the ASIL-D isolation criteria.
- Open Access
- 1 July 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-17
Adaptive electronics for photovoltaic, photoluminescent and photometric methods in power harvesting for wireless wearable sensors
The increasing demand for continuous, comprehensive physiological information captured by skin-interfaced wireless sensors is hindered by their relatively high-power consumption and the associated patient discomfort that can follow from the use of high capacity batteries. This paper presents an adaptive electronics platform and a tri-modal energy harvesting approach to reduce the need for battery power. Specifically, the schemes focus on sensors that involve light in their operation, through use of (i) photometric methods, where ambient light contributes directly to the measurement process, (ii) multijunction photovoltaic cells, where ambient light powers operation and/or charges an integrated battery, and (iii) photoluminescent packaging, where ambient light activates light-emitting species to enhance the first two schemes. Additional features of interest are in (i) in-sensor computational approaches that decrease the bandwidth and thus the energy consumption in wireless data communication and (ii) radio frequency power transfer for battery charging. These ideas have utility across broad other classes of wearable devices as well as small, portable electronic gadgetry.
- 1 July 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-17
Open AccessAdaptive electronics for photovoltaic, photoluminescent and photometric methods in power harvesting for wireless wearable sensors
The increasing demand for continuous, comprehensive physiological information captured by skin-interfaced wireless sensors is hindered by their relatively high-power consumption and the associated patient discomfort that can follow from the use of high capacity batteries. This paper presents an adaptive electronics platform and a tri-modal energy harvesting approach to reduce the need for battery power. Specifically, the schemes focus on sensors that involve light in their operation, through use of (i) photometric methods, where ambient light contributes directly to the measurement process, (ii) multijunction photovoltaic cells, where ambient light powers operation and/or charges an integrated battery, and (iii) photoluminescent packaging, where ambient light activates light-emitting species to enhance the first two schemes. Additional features of interest are in (i) in-sensor computational approaches that decrease the bandwidth and thus the energy consumption in wireless data communication and (ii) radio frequency power transfer for battery charging. These ideas have utility across broad other classes of wearable devices as well as small, portable electronic gadgetry.
- Open Access
- 27 June 2025
- Published by Wiley in Advanced Electronic Materials
- Vol. 11 (10)
Recent Advances in Bioresorbable Biomedical Applications: From Materials to Devices
Wearable and implantable devices provide users with continuous monitoring and treatment, and bioresorbable features can facilitate the use of temporary biomedical devicesand reduce electronic wastes (e‐wastes). Bioresorbable metals and polymers offer multiple benefits, such as high conductivity and mechanical support, for skin‐interfaced and implantable biomedical devices in versatile biomedical applications. These materials dissolve naturally after their targeted lifetime, avoiding complications arising from retrieval surgeries and preventing e‐waste accumulation. This review summarizes recent advances in both bioresorbable materials and devices, highlighting various polymers, semiconductors, and metal options along with their dissolution processes. The following contents introduce the current developments in bioresorbable skin‐interfaced and implantable systems including electrostimulation (ES), energy harvesting, sensor, and transistor systems. A concluding section discusses current challenges and future research opportunities in this field.
- 27 June 2025
- Published by Wiley in Advanced Electronic Materials
- Vol. 11 (10)
Open AccessRecent Advances in Bioresorbable Biomedical Applications: From Materials to Devices
Wearable and implantable devices provide users with continuous monitoring and treatment, and bioresorbable features can facilitate the use of temporary biomedical devicesand reduce electronic wastes (e‐wastes). Bioresorbable metals and polymers offer multiple benefits, such as high conductivity and mechanical support, for skin‐interfaced and implantable biomedical devices in versatile biomedical applications. These materials dissolve naturally after their targeted lifetime, avoiding complications arising from retrieval surgeries and preventing e‐waste accumulation. This review summarizes recent advances in both bioresorbable materials and devices, highlighting various polymers, semiconductors, and metal options along with their dissolution processes. The following contents introduce the current developments in bioresorbable skin‐interfaced and implantable systems including electrostimulation (ES), energy harvesting, sensor, and transistor systems. A concluding section discusses current challenges and future research opportunities in this field.
- 20 September 2024
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 422, 136667
Enhancing flexibility of smart bioresorbable vascular scaffolds through 3D printing using polycaprolactone and polylactic acid
- 20 September 2024
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 422, 136667
Enhancing flexibility of smart bioresorbable vascular scaffolds through 3D printing using polycaprolactone and polylactic acid
- 5 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (3) , 3202-3212
Small-Perturbation Electrochemical Impedance Spectroscopy System With High Accuracy for High-Capacity Batteries in Electric Vehicles
This article presents an electrochemical impedance spectroscopy (EIS) system optimized for high-capacity electric vehicle (EV) batteries, prioritizing high measurement accuracy with minimal current perturbation while reducing measurement time. The system incorporates a switched-resistor high-pass filter for accurate ac voltage measurement and a low-noise amplifier for signal amplification. It also features two parallel low-pass filters with tailored bandwidths (0.2 Hz for 1–9 Hz and 1 Hz for 10–1 k Hz), significantly enhancing accuracy and reducing settling time. In addition, the small current perturbation approach improves safety and simplifies the analysis process. Our prototype achieves precise impedance measurement with a standard deviation of less than 10.4 $\boldsymbol{\mu}\boldsymbol{\Omega}$ for high-precision resistors and less than 14 $\boldsymbol{\mu}\boldsymbol{\Omega}$ root-mean-square error in magnitude for a 70 Ah battery across 1–1 k Hz frequency range and 20–80% state-of-charge range at 25${}^{\circ}\text{C}$ temperature. These findings demonstrate the proposed EIS system's effectiveness in the accurate assessment and health monitoring of large EV batteries.
- 5 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (3) , 3202-3212
Small-Perturbation Electrochemical Impedance Spectroscopy System With High Accuracy for High-Capacity Batteries in Electric Vehicles
This article presents an electrochemical impedance spectroscopy (EIS) system optimized for high-capacity electric vehicle (EV) batteries, prioritizing high measurement accuracy with minimal current perturbation while reducing measurement time. The system incorporates a switched-resistor high-pass filter for accurate ac voltage measurement and a low-noise amplifier for signal amplification. It also features two parallel low-pass filters with tailored bandwidths (0.2 Hz for 1–9 Hz and 1 Hz for 10–1 k Hz), significantly enhancing accuracy and reducing settling time. In addition, the small current perturbation approach improves safety and simplifies the analysis process. Our prototype achieves precise impedance measurement with a standard deviation of less than 10.4 $\boldsymbol{\mu}\boldsymbol{\Omega}$ for high-precision resistors and less than 14 $\boldsymbol{\mu}\boldsymbol{\Omega}$ root-mean-square error in magnitude for a 70 Ah battery across 1–1 k Hz frequency range and 20–80% state-of-charge range at 25${}^{\circ}\text{C}$ temperature. These findings demonstrate the proposed EIS system's effectiveness in the accurate assessment and health monitoring of large EV batteries.