Seungwan Jeon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Seungwan Jeon has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Chulhong Kim
Pohang University of Science and Technology (POSTECH)
9 shared publications - Ravi Managuli
Univ. of Washington (United States)
4 shared publications - Wonseok Choi
Department of Biomedical Engineering and Medical Sciences, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea
4 shared publications - Byullee Park
Department of Biophysics, Institute of Quantum Biophysics, Sungkyunkwan University, Suwon, Republic of Korea
2 shared publications - Seonghee Cho
Pohang University of Science and Technology (POSTECH)
2 shared publications - Changyeop Lee1 shared publication
Latest Publications
- Top Cited Papers
- 1 May 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 303 (2) , 467-473
Three-dimensional Multistructural Quantitative Photoacoustic and US Imaging of Human Feet in Vivo
Three-dimensional bimodal photoacoustic/US imaging provided volumetric and multiparametric information about morphologic and physiologic features of the human foot, potentially useful in diagnosing... Background Monitoring the microcirculation in human feet is crucial in assessing peripheral vascular diseases, such as diabetic foot. However, conventional imaging modalities are more focused on di...
- 1 May 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 303 (2) , 467-473
Top Cited PapersThree-dimensional Multistructural Quantitative Photoacoustic and US Imaging of Human Feet in Vivo
Three-dimensional bimodal photoacoustic/US imaging provided volumetric and multiparametric information about morphologic and physiologic features of the human foot, potentially useful in diagnosing... Background Monitoring the microcirculation in human feet is crucial in assessing peripheral vascular diseases, such as diabetic foot. However, conventional imaging modalities are more focused on di...
- Open Access
- 19 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Image Processing
- Vol. 30 (10577149) , 8773-8784
A Deep Learning-Based Model That Reduces Speed of Sound Aberrations for Improved In Vivo Photoacoustic Imaging
Photoacoustic imaging (PAI) has attracted great attention as a medical imaging method. Typically, photoacoustic (PA) images are reconstructed via beamforming, but many factors still hinder the beamforming techniques in reconstructing optimal images in terms of image resolution, imaging depth, or processing speed. Here, we demonstrate a novel deep learning PAI that uses multiple speed of sound (SoS) inputs. With this novel method, we achieved SoS aberration mitigation, streak artifact removal, and temporal resolution improvement all at once in structural and functional in vivo PA images of healthy human limbs and melanoma patients. The presented method produces high-contrast PA images in vivo with reduced distortion, even in adverse conditions where the medium is heterogeneous and/or the data sampling is sparse. Thus, we believe that this new method can achieve high image quality with fast data acquisition and can contribute to the advance of clinical PAI.
- 19 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Image Processing
- Vol. 30 (10577149) , 8773-8784
Open AccessA Deep Learning-Based Model That Reduces Speed of Sound Aberrations for Improved In Vivo Photoacoustic Imaging
Photoacoustic imaging (PAI) has attracted great attention as a medical imaging method. Typically, photoacoustic (PA) images are reconstructed via beamforming, but many factors still hinder the beamforming techniques in reconstructing optimal images in terms of image resolution, imaging depth, or processing speed. Here, we demonstrate a novel deep learning PAI that uses multiple speed of sound (SoS) inputs. With this novel method, we achieved SoS aberration mitigation, streak artifact removal, and temporal resolution improvement all at once in structural and functional in vivo PA images of healthy human limbs and melanoma patients. The presented method produces high-contrast PA images in vivo with reduced distortion, even in adverse conditions where the medium is heterogeneous and/or the data sampling is sparse. Thus, we believe that this new method can achieve high image quality with fast data acquisition and can contribute to the advance of clinical PAI.
- 11 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (1) , 222-232
Bi-Modal Transfer Learning for Classifying Breast Cancers via Combined B-Mode and Ultrasound Strain Imaging
Although accurate detection of breast cancer still poses significant challenges, deep learning (DL) can support more accurate image interpretation. In this study, we develop a highly robust DL model based on combined B-mode ultrasound (B-mode) and strain elastography ultrasound (SE) images for classifying benign and malignant breast tumors. This study retrospectively included 85 patients, including 42 with benign lesions and 43 with malignancies, all confirmed by biopsy. Two deep neural network models, AlexNet and ResNet, were separately trained on combined 205 B-mode and 205 SE images (80% for training and 20% for validation) from 67 patients with benign and malignant lesions. These two models were then configured to work as an ensemble using both image-wise and layer-wise and tested on a dataset of 56 images from the remaining 18 patients. The ensemble model captures the diverse features present in the B-mode and SE images and also combines semantic features from AlexNet and ResNet models to classify the benign from the malignant tumors. The experimental results demonstrate that the accuracy of the proposed ensemble model is 90%, which is better than the individual models and the model trained using B-mode or SE images alone. Moreover, some patients that were misclassified by the traditional methods were correctly classified by the proposed ensemble method. The proposed ensemble DL model will enable radiologists to achieve superior detection efficiency owing to enhance classification accuracy for breast cancers in ultrasound (US) images.
- 11 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (1) , 222-232
Bi-Modal Transfer Learning for Classifying Breast Cancers via Combined B-Mode and Ultrasound Strain Imaging
Although accurate detection of breast cancer still poses significant challenges, deep learning (DL) can support more accurate image interpretation. In this study, we develop a highly robust DL model based on combined B-mode ultrasound (B-mode) and strain elastography ultrasound (SE) images for classifying benign and malignant breast tumors. This study retrospectively included 85 patients, including 42 with benign lesions and 43 with malignancies, all confirmed by biopsy. Two deep neural network models, AlexNet and ResNet, were separately trained on combined 205 B-mode and 205 SE images (80% for training and 20% for validation) from 67 patients with benign and malignant lesions. These two models were then configured to work as an ensemble using both image-wise and layer-wise and tested on a dataset of 56 images from the remaining 18 patients. The ensemble model captures the diverse features present in the B-mode and SE images and also combines semantic features from AlexNet and ResNet models to classify the benign from the malignant tumors. The experimental results demonstrate that the accuracy of the proposed ensemble model is 90%, which is better than the individual models and the model trained using B-mode or SE images alone. Moreover, some patients that were misclassified by the traditional methods were correctly classified by the proposed ensemble method. The proposed ensemble DL model will enable radiologists to achieve superior detection efficiency owing to enhance classification accuracy for breast cancers in ultrasound (US) images.
- 5 March 2021
- Published by SPIE-Intl Soc Optical Eng
- p. 10
Nonlinear photoacoustic and ultrasound beamforming through spectral magnitude scaling
SPIE Digital Library Proceedings
- 5 March 2021
- Published by SPIE-Intl Soc Optical Eng
- p. 10
Nonlinear photoacoustic and ultrasound beamforming through spectral magnitude scaling
SPIE Digital Library Proceedings
- Open Access
- 27 August 2020
- Published by MDPI AG in Electronics
- Vol. 9 (9) , 1388
Multi-Channel Transfer Learning of Chest X-ray Images for Screening of COVID-19
The 2019 novel coronavirus (COVID-19) has spread rapidly all over the world. The standard test for screening COVID-19 patients is the polymerase chain reaction test. As this method is time consuming, as an alternative, chest X-rays may be considered for quick screening. However, specialization is required to read COVID-19 chest X-ray images as they vary in features. To address this, we present a multi-channel pre-trained ResNet architecture to facilitate the diagnosis of COVID-19 chest X-ray. Three ResNet-based models were retrained to classify X-rays in a one-against-all basis from (a) normal or diseased, (b) pneumonia or non-pneumonia, and (c) COVID-19 or non-COVID19 individuals. Finally, these three models were ensembled and fine-tuned using X-rays from 1579 normal, 4245 pneumonia, and 184 COVID-19 individuals to classify normal, pneumonia, and COVID-19 cases in a one-against-one framework. Our results show that the ensemble model is more accurate than the single model as it extracts more relevant semantic features for each class. The method provides a precision of 94% and a recall of 100%. It could potentially help clinicians in screening patients for COVID-19, thus facilitating immediate triaging and treatment for better outcomes.
- 27 August 2020
- Published by MDPI AG in Electronics
- Vol. 9 (9) , 1388
Open AccessMulti-Channel Transfer Learning of Chest X-ray Images for Screening of COVID-19
The 2019 novel coronavirus (COVID-19) has spread rapidly all over the world. The standard test for screening COVID-19 patients is the polymerase chain reaction test. As this method is time consuming, as an alternative, chest X-rays may be considered for quick screening. However, specialization is required to read COVID-19 chest X-ray images as they vary in features. To address this, we present a multi-channel pre-trained ResNet architecture to facilitate the diagnosis of COVID-19 chest X-ray. Three ResNet-based models were retrained to classify X-rays in a one-against-all basis from (a) normal or diseased, (b) pneumonia or non-pneumonia, and (c) COVID-19 or non-COVID19 individuals. Finally, these three models were ensembled and fine-tuned using X-rays from 1579 normal, 4245 pneumonia, and 184 COVID-19 individuals to classify normal, pneumonia, and COVID-19 cases in a one-against-one framework. Our results show that the ensemble model is more accurate than the single model as it extracts more relevant semantic features for each class. The method provides a precision of 94% and a recall of 100%. It could potentially help clinicians in screening patients for COVID-19, thus facilitating immediate triaging and treatment for better outcomes.
- Top Cited PapersOpen Access
- 1 September 2019
- Published by Elsevier in Photoacoustics
- Vol. 15, 100141
Review on practical photoacoustic microscopy
- 1 September 2019
- Published by Elsevier in Photoacoustics
- Vol. 15, 100141
Top Cited PapersOpen AccessReview on practical photoacoustic microscopy
- Open Access
- 1 September 2019
- Published by Elsevier in Photoacoustics
- Vol. 15, 100136
Real-time delay-multiply-and-sum beamforming with coherence factor for in vivo clinical photoacoustic imaging of humans
- 1 September 2019
- Published by Elsevier in Photoacoustics
- Vol. 15, 100136
Open AccessReal-time delay-multiply-and-sum beamforming with coherence factor for in vivo clinical photoacoustic imaging of humans
- 31 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 38 (1) , 250-260
A Novel 2-D Synthetic Aperture Focusing Technique for Acoustic-Resolution Photoacoustic Microscopy
Acoustic-resolution photoacoustic microscopy (AR-PAM) is a promising technology for vascular or tumor-targeted molecular imaging. Unique advantages of AR-PM are its non-invasive, non-ionizing real-time and deeper imaging depth. AR-PAM typically uses an ultrasound (US) transducer with a high acoustic numerical aperture (NA) to enable deeper imaging depth. While high NA achieves good lateral resolution in the focal plane but significantly degrades the lateral resolution in the out-of-focus region. Synthetic aperture focusing technique (SAFT) has been introduced to overcome this out-of-focus degradation by synthesizing the correlated signals. Several 2D SAFTs have been also reported to improve degraded resolution in all directions. However, the resolution enhancement of the previously reported 2D SAFTs are suboptimal and are not equivalent to the 1D SAFT performance under ideal condition with the sample orientation perpendicular to the synthetic aperture direction. In this study, we present a new 2D SAFT called 2D directional SAFT (2D-D-SAFT) that improves the lateral resolution significantly and we compare our results against 1D SAFT under ideal condition. We applied this algorithm to phantom and in vivo images to show the improvement in image quality. We also implement this algorithm in a graphic processing unit (GPU) to achieve high performance to show the practicality of implementing this new algorithm in a system.
- 31 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 38 (1) , 250-260
A Novel 2-D Synthetic Aperture Focusing Technique for Acoustic-Resolution Photoacoustic Microscopy
Acoustic-resolution photoacoustic microscopy (AR-PAM) is a promising technology for vascular or tumor-targeted molecular imaging. Unique advantages of AR-PM are its non-invasive, non-ionizing real-time and deeper imaging depth. AR-PAM typically uses an ultrasound (US) transducer with a high acoustic numerical aperture (NA) to enable deeper imaging depth. While high NA achieves good lateral resolution in the focal plane but significantly degrades the lateral resolution in the out-of-focus region. Synthetic aperture focusing technique (SAFT) has been introduced to overcome this out-of-focus degradation by synthesizing the correlated signals. Several 2D SAFTs have been also reported to improve degraded resolution in all directions. However, the resolution enhancement of the previously reported 2D SAFTs are suboptimal and are not equivalent to the 1D SAFT performance under ideal condition with the sample orientation perpendicular to the synthetic aperture direction. In this study, we present a new 2D SAFT called 2D directional SAFT (2D-D-SAFT) that improves the lateral resolution significantly and we compare our results against 1D SAFT under ideal condition. We applied this algorithm to phantom and in vivo images to show the improvement in image quality. We also implement this algorithm in a graphic processing unit (GPU) to achieve high performance to show the practicality of implementing this new algorithm in a system.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Notice of Removal: Handheld optical-resolution photoacoustic microscopy probe for preclinical application
Removed.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Notice of Removal: Handheld optical-resolution photoacoustic microscopy probe for preclinical application
Removed.