Ravi Managuli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ravi Managuli has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Chulhong Kim
Pohang University of Science and Technology (POSTECH)
5 shared publications - Seungwan Jeon
Department of Creative IT Engineering, Pohang University of Science and Technology (POSTECH), Pohang, 37673, Republic of Korea
4 shared publications - Richard G. Barr
Department of Radiology Northeast Ohio Medical University Rootstown Ohio USA
2 shared publications - Seonghee Cho
Pohang University of Science and Technology (POSTECH)
2 shared publications - Wonseok Choi
Department of Biomedical Engineering and Medical Sciences, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea
2 shared publications Albert Gee
Zonare Medical Systems Mountain View California USA
1 shared publication
Latest Publications
- 11 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (1) , 222-232
Bi-Modal Transfer Learning for Classifying Breast Cancers via Combined B-Mode and Ultrasound Strain Imaging
Although accurate detection of breast cancer still poses significant challenges, deep learning (DL) can support more accurate image interpretation. In this study, we develop a highly robust DL model based on combined B-mode ultrasound (B-mode) and strain elastography ultrasound (SE) images for classifying benign and malignant breast tumors. This study retrospectively included 85 patients, including 42 with benign lesions and 43 with malignancies, all confirmed by biopsy. Two deep neural network models, AlexNet and ResNet, were separately trained on combined 205 B-mode and 205 SE images (80% for training and 20% for validation) from 67 patients with benign and malignant lesions. These two models were then configured to work as an ensemble using both image-wise and layer-wise and tested on a dataset of 56 images from the remaining 18 patients. The ensemble model captures the diverse features present in the B-mode and SE images and also combines semantic features from AlexNet and ResNet models to classify the benign from the malignant tumors. The experimental results demonstrate that the accuracy of the proposed ensemble model is 90%, which is better than the individual models and the model trained using B-mode or SE images alone. Moreover, some patients that were misclassified by the traditional methods were correctly classified by the proposed ensemble method. The proposed ensemble DL model will enable radiologists to achieve superior detection efficiency owing to enhance classification accuracy for breast cancers in ultrasound (US) images.
- 11 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (1) , 222-232
Bi-Modal Transfer Learning for Classifying Breast Cancers via Combined B-Mode and Ultrasound Strain Imaging
Although accurate detection of breast cancer still poses significant challenges, deep learning (DL) can support more accurate image interpretation. In this study, we develop a highly robust DL model based on combined B-mode ultrasound (B-mode) and strain elastography ultrasound (SE) images for classifying benign and malignant breast tumors. This study retrospectively included 85 patients, including 42 with benign lesions and 43 with malignancies, all confirmed by biopsy. Two deep neural network models, AlexNet and ResNet, were separately trained on combined 205 B-mode and 205 SE images (80% for training and 20% for validation) from 67 patients with benign and malignant lesions. These two models were then configured to work as an ensemble using both image-wise and layer-wise and tested on a dataset of 56 images from the remaining 18 patients. The ensemble model captures the diverse features present in the B-mode and SE images and also combines semantic features from AlexNet and ResNet models to classify the benign from the malignant tumors. The experimental results demonstrate that the accuracy of the proposed ensemble model is 90%, which is better than the individual models and the model trained using B-mode or SE images alone. Moreover, some patients that were misclassified by the traditional methods were correctly classified by the proposed ensemble method. The proposed ensemble DL model will enable radiologists to achieve superior detection efficiency owing to enhance classification accuracy for breast cancers in ultrasound (US) images.
- 18 July 2021
- Published by Springer Nature
- p. 51-70
Instrumentation
- 5 March 2021
- Published by SPIE-Intl Soc Optical Eng
- p. 9
3D volumetric visualization MATLAB toolkit for photoacoustic imaging plus more
SPIE Digital Library Proceedings
- 5 March 2021
- Published by SPIE-Intl Soc Optical Eng
- p. 9
3D volumetric visualization MATLAB toolkit for photoacoustic imaging plus more
SPIE Digital Library Proceedings
- 5 March 2021
- Published by SPIE-Intl Soc Optical Eng
- p. 10
Nonlinear photoacoustic and ultrasound beamforming through spectral magnitude scaling
SPIE Digital Library Proceedings
- 5 March 2021
- Published by SPIE-Intl Soc Optical Eng
- p. 10
Nonlinear photoacoustic and ultrasound beamforming through spectral magnitude scaling
SPIE Digital Library Proceedings
- 7 January 2021
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 40 (3) , 569-581
Radiological Society of North America/Quantitative Imaging Biomarker Alliance Shear Wave Speed Bias Quantification in Elastic and Viscoelastic Phantoms
Objectives: To quantify the bias of shear wave speed (SWS) measurements between different commercial ultrasonic shear elasticity systems and a magnetic resonance elastography (MRE) system in elastic and viscoelastic phantoms.Methods: Two elastic phantoms, representing healthy through fibrotic liver, were measured with 5 different ultrasound platforms, and 3 viscoelastic phantoms, representing healthy through fibrotic liver tissue, were measured with 12 different ultrasound platforms. Measurements were performed with different systems at different sites, at 3 focal depths, and with different appraisers. The SWS bias across the systems was quantified as a function of the system, site, focal depth, and appraiser. A single MRE research system was also used to characterize these phantoms using discrete frequencies from 60 to 500 Hz.Results: The SWS from different systems had mean difference 95% confidence intervals of ±0.145 m/s (±9.6%) across both elastic phantoms and ± 0.340 m/s (±15.3%) across the viscoelastic phantoms. The focal depth and appraiser were less significant sources of SWS variability than the system and site. Magnetic resonance elastography best matched the ultrasonic SWS in the viscoelastic phantoms using a 140 Hz source but had a − 0.27 ± 0.027‐m/s (−12.2% ± 1.2%) bias when using the clinically implemented 60‐Hz vibration source.Conclusions: Shear wave speed reconstruction across different manufacturer systems is more consistent in elastic than viscoelastic phantoms, with a mean difference bias of < ±10% in all cases. Magnetic resonance elastographic measurements in the elastic and viscoelastic phantoms best match the ultrasound systems with a 140‐Hz excitation but have a significant negative bias operating at 60 Hz. This study establishes a foundation for meaningful comparison of SWS measurements made with different platforms.
- 7 January 2021
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 40 (3) , 569-581
Radiological Society of North America/Quantitative Imaging Biomarker Alliance Shear Wave Speed Bias Quantification in Elastic and Viscoelastic Phantoms
Objectives: To quantify the bias of shear wave speed (SWS) measurements between different commercial ultrasonic shear elasticity systems and a magnetic resonance elastography (MRE) system in elastic and viscoelastic phantoms.Methods: Two elastic phantoms, representing healthy through fibrotic liver, were measured with 5 different ultrasound platforms, and 3 viscoelastic phantoms, representing healthy through fibrotic liver tissue, were measured with 12 different ultrasound platforms. Measurements were performed with different systems at different sites, at 3 focal depths, and with different appraisers. The SWS bias across the systems was quantified as a function of the system, site, focal depth, and appraiser. A single MRE research system was also used to characterize these phantoms using discrete frequencies from 60 to 500 Hz.Results: The SWS from different systems had mean difference 95% confidence intervals of ±0.145 m/s (±9.6%) across both elastic phantoms and ± 0.340 m/s (±15.3%) across the viscoelastic phantoms. The focal depth and appraiser were less significant sources of SWS variability than the system and site. Magnetic resonance elastography best matched the ultrasonic SWS in the viscoelastic phantoms using a 140 Hz source but had a − 0.27 ± 0.027‐m/s (−12.2% ± 1.2%) bias when using the clinically implemented 60‐Hz vibration source.Conclusions: Shear wave speed reconstruction across different manufacturer systems is more consistent in elastic than viscoelastic phantoms, with a mean difference bias of < ±10% in all cases. Magnetic resonance elastographic measurements in the elastic and viscoelastic phantoms best match the ultrasound systems with a 140‐Hz excitation but have a significant negative bias operating at 60 Hz. This study establishes a foundation for meaningful comparison of SWS measurements made with different platforms.
- Open Access
- 1 September 2019
- Published by Elsevier in Photoacoustics
- Vol. 15, 100136
Real-time delay-multiply-and-sum beamforming with coherence factor for in vivo clinical photoacoustic imaging of humans
- 1 September 2019
- Published by Elsevier in Photoacoustics
- Vol. 15, 100136
Open AccessReal-time delay-multiply-and-sum beamforming with coherence factor for in vivo clinical photoacoustic imaging of humans
- 31 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 38 (1) , 250-260
A Novel 2-D Synthetic Aperture Focusing Technique for Acoustic-Resolution Photoacoustic Microscopy
Acoustic-resolution photoacoustic microscopy (AR-PAM) is a promising technology for vascular or tumor-targeted molecular imaging. Unique advantages of AR-PM are its non-invasive, non-ionizing real-time and deeper imaging depth. AR-PAM typically uses an ultrasound (US) transducer with a high acoustic numerical aperture (NA) to enable deeper imaging depth. While high NA achieves good lateral resolution in the focal plane but significantly degrades the lateral resolution in the out-of-focus region. Synthetic aperture focusing technique (SAFT) has been introduced to overcome this out-of-focus degradation by synthesizing the correlated signals. Several 2D SAFTs have been also reported to improve degraded resolution in all directions. However, the resolution enhancement of the previously reported 2D SAFTs are suboptimal and are not equivalent to the 1D SAFT performance under ideal condition with the sample orientation perpendicular to the synthetic aperture direction. In this study, we present a new 2D SAFT called 2D directional SAFT (2D-D-SAFT) that improves the lateral resolution significantly and we compare our results against 1D SAFT under ideal condition. We applied this algorithm to phantom and in vivo images to show the improvement in image quality. We also implement this algorithm in a graphic processing unit (GPU) to achieve high performance to show the practicality of implementing this new algorithm in a system.
- 31 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 38 (1) , 250-260
A Novel 2-D Synthetic Aperture Focusing Technique for Acoustic-Resolution Photoacoustic Microscopy
Acoustic-resolution photoacoustic microscopy (AR-PAM) is a promising technology for vascular or tumor-targeted molecular imaging. Unique advantages of AR-PM are its non-invasive, non-ionizing real-time and deeper imaging depth. AR-PAM typically uses an ultrasound (US) transducer with a high acoustic numerical aperture (NA) to enable deeper imaging depth. While high NA achieves good lateral resolution in the focal plane but significantly degrades the lateral resolution in the out-of-focus region. Synthetic aperture focusing technique (SAFT) has been introduced to overcome this out-of-focus degradation by synthesizing the correlated signals. Several 2D SAFTs have been also reported to improve degraded resolution in all directions. However, the resolution enhancement of the previously reported 2D SAFTs are suboptimal and are not equivalent to the 1D SAFT performance under ideal condition with the sample orientation perpendicular to the synthetic aperture direction. In this study, we present a new 2D SAFT called 2D directional SAFT (2D-D-SAFT) that improves the lateral resolution significantly and we compare our results against 1D SAFT under ideal condition. We applied this algorithm to phantom and in vivo images to show the improvement in image quality. We also implement this algorithm in a graphic processing unit (GPU) to achieve high performance to show the practicality of implementing this new algorithm in a system.