Junior Arroyo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Junior Arroyo has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Jiaxin Zhang
Johns Hopkins University, Department of Electrical and Computer Engineering, Baltimore, Maryland, United States
4 shared publications - Muyinatu A. Lediju Bell
Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, USA
4 shared publications - Amanda Rae Maxwell
Johns Hopkins University, Department of Molecular and Comparative Pathobiology, Baltimore, Maryland, United States
1 shared publication - Arunima Sharma
Department of Electrical and Computer Engineering, Johns Hopkins University , Baltimore, MD 21218
1 shared publication Eduardo A. Gonzalez
Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland, United States
1 shared publication- Fernando G. Torres
Department of Mechanical Engineering, Pontificia Universidad Catolica del Peru, Av. Universitaria 1801, Lima 15088, Peru
1 shared publication
Latest Publications
- Open Access
- 1 August 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (08) , 1-15
Pigmentation-dependent skin injury thresholds with nanosecond single-pulse laser exposure
SignificanceMaximum permissible exposure limits defined in ANSI Z136.1 are broadly protective, but they do not explicitly account for pigmentation differences in skin. As a result, the lack of experimental data quantifying the effect of pigmentation on injury thresholds constrains accurate interpretation when melanin is a primary optical absorber, which has direct implications for the performance of optics-based imaging methods.AimWe experimentally determined the pigmentation-dependent laser exposure dose that produces a visible injury in 50% of exposed sites (i.e., ED50 injury thresholds) with nanosecond, 750-nm-wavelength pulses, and we provide the first known quantification of relationships between melanin index (MI) and individual typology angle (ITA) or erythema index (EI) through colorimetric measurements.ApproachFifty total abdominal skin sites per swine were identified on three swine with different pigmentation phenotypes (median ITA values per swine ranged −18° to 87°). Single-laser pulses with 5-ns pulse duration, 750-nm-wavelength, and energies of 35, 40, 50, 60, and 65 mJ per pulse were delivered to 10 sites per energy level per swine. Laser-exposed sites were visually assessed at early post-exposure intervals, followed by colorimeter measurements of MI, ITA, and EI. Probit regression analysis was used to compute the ED50 thresholds, followed by a polynomial regression analysis conducted to relate ITA to MI and EI to MI.ResultsDark-skinned swine (median ITA=−18°) exhibited a 27.7% lower ED50 (323.94 mJ/cm2) than light-skinned swine (median ITA=69.5°, ED50=448.36 mJ/cm2), which is consistent with increased melanin-mediated absorption in the darker-skinned swine. The lightest-skin swine (median ITA=87°) did not develop visible erythema within the tested exposure range, preventing ED50 estimation. Mathematical MI–ITA and MI–EI relationships revealed pigmentation-dependent optical and inflammatory responses across the three swine.ConclusionsThe measured differences in ED50 values quantify the impact of skin pigmentation on laser-induced injury risk and demonstrate that darker skin has greater susceptibility to damage with the investigated laser parameters, relative to lighter skin. This foundational work addresses a previously uncharacterized source of biological variability that is relevant for the interpretation of laser safety margins and the design and evaluation of optics-based systems.
- 1 August 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (08) , 1-15
Open AccessPigmentation-dependent skin injury thresholds with nanosecond single-pulse laser exposure
SignificanceMaximum permissible exposure limits defined in ANSI Z136.1 are broadly protective, but they do not explicitly account for pigmentation differences in skin. As a result, the lack of experimental data quantifying the effect of pigmentation on injury thresholds constrains accurate interpretation when melanin is a primary optical absorber, which has direct implications for the performance of optics-based imaging methods.AimWe experimentally determined the pigmentation-dependent laser exposure dose that produces a visible injury in 50% of exposed sites (i.e., ED50 injury thresholds) with nanosecond, 750-nm-wavelength pulses, and we provide the first known quantification of relationships between melanin index (MI) and individual typology angle (ITA) or erythema index (EI) through colorimetric measurements.ApproachFifty total abdominal skin sites per swine were identified on three swine with different pigmentation phenotypes (median ITA values per swine ranged −18° to 87°). Single-laser pulses with 5-ns pulse duration, 750-nm-wavelength, and energies of 35, 40, 50, 60, and 65 mJ per pulse were delivered to 10 sites per energy level per swine. Laser-exposed sites were visually assessed at early post-exposure intervals, followed by colorimeter measurements of MI, ITA, and EI. Probit regression analysis was used to compute the ED50 thresholds, followed by a polynomial regression analysis conducted to relate ITA to MI and EI to MI.ResultsDark-skinned swine (median ITA=−18°) exhibited a 27.7% lower ED50 (323.94 mJ/cm2) than light-skinned swine (median ITA=69.5°, ED50=448.36 mJ/cm2), which is consistent with increased melanin-mediated absorption in the darker-skinned swine. The lightest-skin swine (median ITA=87°) did not develop visible erythema within the tested exposure range, preventing ED50 estimation. Mathematical MI–ITA and MI–EI relationships revealed pigmentation-dependent optical and inflammatory responses across the three swine.ConclusionsThe measured differences in ED50 values quantify the impact of skin pigmentation on laser-induced injury risk and demonstrate that darker skin has greater susceptibility to damage with the investigated laser parameters, relative to lighter skin. This foundational work addresses a previously uncharacterized source of biological variability that is relevant for the interpretation of laser safety margins and the design and evaluation of optics-based systems.
- Open Access
- 1 March 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (03) , 1-12
In vivo photoacoustic imaging of swine ureters injected with methylene blue
SignificanceUreteral injuries represent a major concern during a range of surgical procedures, due to the proximity of the ureter to target surgical structures. Intraoperative identification of the ureter is critical to prevent this accidental damage.AimWe demonstrate the first known in vivo photoacoustic imaging of the ureter in swine following intravenous administration of FDA-approved methylene blue, enabled by a software-hardware integration that has not been previously reported in the literature.ApproachPhotoacoustic channel data from the ureters of two swine were acquired using a Vevo F2 ultrasound system and an Opotek Phocus Mobile laser. Images were beamformed using a delay-and-sum algorithm. Photoacoustic image quality was evaluated using contrast, signal-to-noise ratio (SNR), and generalized contrast-to-noise ratio (gCNR) metrics, measured 10 to 80 min after methylene blue injection.ResultsAcross the 10- to 80-min imaging window, median contrast (3.46–11.43 dB), SNR (2.84–6.99), and gCNR (0.27–0.64) confirmed sustained ureter visibility with methylene blue. Maximum image quality was observed 20- to 30-min after methylene blue injection, with significantly higher contrast, SNR, and gCNR values compared with earlier or later time points (p<0.05).ConclusionsIn vivo results demonstrate that methylene-blue-enhanced photoacoustic imaging can visualize the ureter over a time duration that is consistent with the length of surgical procedures, providing initial feasibility for real-time photoacoustic-guided surgery applications.
- 1 March 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (03) , 1-12
Open AccessIn vivo photoacoustic imaging of swine ureters injected with methylene blue
SignificanceUreteral injuries represent a major concern during a range of surgical procedures, due to the proximity of the ureter to target surgical structures. Intraoperative identification of the ureter is critical to prevent this accidental damage.AimWe demonstrate the first known in vivo photoacoustic imaging of the ureter in swine following intravenous administration of FDA-approved methylene blue, enabled by a software-hardware integration that has not been previously reported in the literature.ApproachPhotoacoustic channel data from the ureters of two swine were acquired using a Vevo F2 ultrasound system and an Opotek Phocus Mobile laser. Images were beamformed using a delay-and-sum algorithm. Photoacoustic image quality was evaluated using contrast, signal-to-noise ratio (SNR), and generalized contrast-to-noise ratio (gCNR) metrics, measured 10 to 80 min after methylene blue injection.ResultsAcross the 10- to 80-min imaging window, median contrast (3.46–11.43 dB), SNR (2.84–6.99), and gCNR (0.27–0.64) confirmed sustained ureter visibility with methylene blue. Maximum image quality was observed 20- to 30-min after methylene blue injection, with significantly higher contrast, SNR, and gCNR values compared with earlier or later time points (p<0.05).ConclusionsIn vivo results demonstrate that methylene-blue-enhanced photoacoustic imaging can visualize the ureter over a time duration that is consistent with the length of surgical procedures, providing initial feasibility for real-time photoacoustic-guided surgery applications.
- Open Access
- 1 May 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (05) , 056008-18
Motion-based dynamic light delivery to minimize laser-related thermal damage while preserving photoacoustic image quality
Photoacoustic imaging has consistently showcased its ability to provide significant physiological insight from biological tissue in preclinical settings.1 – 3 This progress promises new possibilities to integrate photoacoustic technology into surgical guidance systems to enhance intraoperative decisions.4 Nanosecond pulses of laser light exposed to photoabsorbers within tissue cause local optical absorption followed by milliKelvin temperature increases that trigger thermal expansion followed by contraction. Light delivery to surgical sites can be achieved by coupling fiber optics to ultrasound receivers,5 positioning light at fixed distances from the receiver,6 or attaching optical fibers to surgical tools.7,8 The common feature among these approaches is a fixed light source (relative to the ultrasound receiver or surgical tool), resulting in what we refer to as stationary light delivery. A handheld light source can also be subtly operated within a narrow surgical window, which is also considered “stationary” light delivery (relative to other components that experience more motion).
- 1 May 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (05) , 056008-18
Open AccessMotion-based dynamic light delivery to minimize laser-related thermal damage while preserving photoacoustic image quality
Photoacoustic imaging has consistently showcased its ability to provide significant physiological insight from biological tissue in preclinical settings.1 – 3 This progress promises new possibilities to integrate photoacoustic technology into surgical guidance systems to enhance intraoperative decisions.4 Nanosecond pulses of laser light exposed to photoabsorbers within tissue cause local optical absorption followed by milliKelvin temperature increases that trigger thermal expansion followed by contraction. Light delivery to surgical sites can be achieved by coupling fiber optics to ultrasound receivers,5 positioning light at fixed distances from the receiver,6 or attaching optical fibers to surgical tools.7,8 The common feature among these approaches is a fixed light source (relative to the ultrasound receiver or surgical tool), resulting in what we refer to as stationary light delivery. A handheld light source can also be subtly operated within a narrow surgical window, which is also considered “stationary” light delivery (relative to other components that experience more motion).
- Open Access
- 1 July 2024
- Published by SPIE-Intl Soc Optical Eng in Biophotonics Discovery
- Vol. 1 (02) , 025003-18
Predictive model for laser-induced tissue necrosis with immunohistochemistry validation
Photoacoustic imaging is a beneficial technology that integrates the advantages of ultrasound and optical imaging. Structures with high optical absorption coefficients absorb light, leading to a localized temperature rise that generates thermal expansion. This expansion results in tissue relaxation and the subsequent isotropic release of acoustic waves, which are ultimately detected by ultrasound sensors. The broad range of targets that can be effectively imaged using photoacoustic imaging has been highlighted in many reports, positioning it as a valuable tool for surgical guidance.1 – 4
- 1 July 2024
- Published by SPIE-Intl Soc Optical Eng in Biophotonics Discovery
- Vol. 1 (02) , 025003-18
Open AccessPredictive model for laser-induced tissue necrosis with immunohistochemistry validation
Photoacoustic imaging is a beneficial technology that integrates the advantages of ultrasound and optical imaging. Structures with high optical absorption coefficients absorb light, leading to a localized temperature rise that generates thermal expansion. This expansion results in tissue relaxation and the subsequent isotropic release of acoustic waves, which are ultimately detected by ultrasound sensors. The broad range of targets that can be effectively imaged using photoacoustic imaging has been highlighted in many reports, positioning it as a valuable tool for surgical guidance.1 – 4
- 1 January 2022
- Published by Optica Publishing Group
- p. JW5B.44
Effect of Light Source Motion on Photoacoustic Image Quality and Safety
Subtle displacement of a light source during photoacoustic imaging reduces possible tissue damage relative to a stationary source, without degrading image quality, which is promising for laser-safe photoacoustic-guided surgery.
- 1 January 2022
- Published by Optica Publishing Group
- p. JW5B.44
Effect of Light Source Motion on Photoacoustic Image Quality and Safety
Subtle displacement of a light source during photoacoustic imaging reduces possible tissue damage relative to a stationary source, without degrading image quality, which is promising for laser-safe photoacoustic-guided surgery.
- 1 May 2019
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 98, 1277-1293
Bacterial cellulose nanocomposites: An all-nano type of material
- 1 May 2019
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 98, 1277-1293
Bacterial cellulose nanocomposites: An all-nano type of material