Jiaxin Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiaxin Zhang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Muyinatu A. Lediju Bell
Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, USA
8 shared publications - Junior Arroyo
Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States
4 shared publications - Mawia Khairalseed
Johns Hopkins University
2 shared publications - Nethra Venkatayogi
Department of Computer Science, Johns Hopkins University, Baltimore, MD, USA
2 shared publications - Alycen Wiacek
Department of Electrical and Computer Engineering Oakland University Rochester Michigan USA
1 shared publication - Amanda Rae Maxwell
Johns Hopkins University, Department of Molecular and Comparative Pathobiology, Baltimore, Maryland, United States
1 shared publication
Latest Publications
- Open Access
- 1 August 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (08) , 1-15
Pigmentation-dependent skin injury thresholds with nanosecond single-pulse laser exposure
SignificanceMaximum permissible exposure limits defined in ANSI Z136.1 are broadly protective, but they do not explicitly account for pigmentation differences in skin. As a result, the lack of experimental data quantifying the effect of pigmentation on injury thresholds constrains accurate interpretation when melanin is a primary optical absorber, which has direct implications for the performance of optics-based imaging methods.AimWe experimentally determined the pigmentation-dependent laser exposure dose that produces a visible injury in 50% of exposed sites (i.e., ED50 injury thresholds) with nanosecond, 750-nm-wavelength pulses, and we provide the first known quantification of relationships between melanin index (MI) and individual typology angle (ITA) or erythema index (EI) through colorimetric measurements.ApproachFifty total abdominal skin sites per swine were identified on three swine with different pigmentation phenotypes (median ITA values per swine ranged −18° to 87°). Single-laser pulses with 5-ns pulse duration, 750-nm-wavelength, and energies of 35, 40, 50, 60, and 65 mJ per pulse were delivered to 10 sites per energy level per swine. Laser-exposed sites were visually assessed at early post-exposure intervals, followed by colorimeter measurements of MI, ITA, and EI. Probit regression analysis was used to compute the ED50 thresholds, followed by a polynomial regression analysis conducted to relate ITA to MI and EI to MI.ResultsDark-skinned swine (median ITA=−18°) exhibited a 27.7% lower ED50 (323.94 mJ/cm2) than light-skinned swine (median ITA=69.5°, ED50=448.36 mJ/cm2), which is consistent with increased melanin-mediated absorption in the darker-skinned swine. The lightest-skin swine (median ITA=87°) did not develop visible erythema within the tested exposure range, preventing ED50 estimation. Mathematical MI–ITA and MI–EI relationships revealed pigmentation-dependent optical and inflammatory responses across the three swine.ConclusionsThe measured differences in ED50 values quantify the impact of skin pigmentation on laser-induced injury risk and demonstrate that darker skin has greater susceptibility to damage with the investigated laser parameters, relative to lighter skin. This foundational work addresses a previously uncharacterized source of biological variability that is relevant for the interpretation of laser safety margins and the design and evaluation of optics-based systems.
- 1 August 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (08) , 1-15
Open AccessPigmentation-dependent skin injury thresholds with nanosecond single-pulse laser exposure
SignificanceMaximum permissible exposure limits defined in ANSI Z136.1 are broadly protective, but they do not explicitly account for pigmentation differences in skin. As a result, the lack of experimental data quantifying the effect of pigmentation on injury thresholds constrains accurate interpretation when melanin is a primary optical absorber, which has direct implications for the performance of optics-based imaging methods.AimWe experimentally determined the pigmentation-dependent laser exposure dose that produces a visible injury in 50% of exposed sites (i.e., ED50 injury thresholds) with nanosecond, 750-nm-wavelength pulses, and we provide the first known quantification of relationships between melanin index (MI) and individual typology angle (ITA) or erythema index (EI) through colorimetric measurements.ApproachFifty total abdominal skin sites per swine were identified on three swine with different pigmentation phenotypes (median ITA values per swine ranged −18° to 87°). Single-laser pulses with 5-ns pulse duration, 750-nm-wavelength, and energies of 35, 40, 50, 60, and 65 mJ per pulse were delivered to 10 sites per energy level per swine. Laser-exposed sites were visually assessed at early post-exposure intervals, followed by colorimeter measurements of MI, ITA, and EI. Probit regression analysis was used to compute the ED50 thresholds, followed by a polynomial regression analysis conducted to relate ITA to MI and EI to MI.ResultsDark-skinned swine (median ITA=−18°) exhibited a 27.7% lower ED50 (323.94 mJ/cm2) than light-skinned swine (median ITA=69.5°, ED50=448.36 mJ/cm2), which is consistent with increased melanin-mediated absorption in the darker-skinned swine. The lightest-skin swine (median ITA=87°) did not develop visible erythema within the tested exposure range, preventing ED50 estimation. Mathematical MI–ITA and MI–EI relationships revealed pigmentation-dependent optical and inflammatory responses across the three swine.ConclusionsThe measured differences in ED50 values quantify the impact of skin pigmentation on laser-induced injury risk and demonstrate that darker skin has greater susceptibility to damage with the investigated laser parameters, relative to lighter skin. This foundational work addresses a previously uncharacterized source of biological variability that is relevant for the interpretation of laser safety margins and the design and evaluation of optics-based systems.
- Open Access
- 1 March 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (03) , 1-12
In vivo photoacoustic imaging of swine ureters injected with methylene blue
SignificanceUreteral injuries represent a major concern during a range of surgical procedures, due to the proximity of the ureter to target surgical structures. Intraoperative identification of the ureter is critical to prevent this accidental damage.AimWe demonstrate the first known in vivo photoacoustic imaging of the ureter in swine following intravenous administration of FDA-approved methylene blue, enabled by a software-hardware integration that has not been previously reported in the literature.ApproachPhotoacoustic channel data from the ureters of two swine were acquired using a Vevo F2 ultrasound system and an Opotek Phocus Mobile laser. Images were beamformed using a delay-and-sum algorithm. Photoacoustic image quality was evaluated using contrast, signal-to-noise ratio (SNR), and generalized contrast-to-noise ratio (gCNR) metrics, measured 10 to 80 min after methylene blue injection.ResultsAcross the 10- to 80-min imaging window, median contrast (3.46–11.43 dB), SNR (2.84–6.99), and gCNR (0.27–0.64) confirmed sustained ureter visibility with methylene blue. Maximum image quality was observed 20- to 30-min after methylene blue injection, with significantly higher contrast, SNR, and gCNR values compared with earlier or later time points (p<0.05).ConclusionsIn vivo results demonstrate that methylene-blue-enhanced photoacoustic imaging can visualize the ureter over a time duration that is consistent with the length of surgical procedures, providing initial feasibility for real-time photoacoustic-guided surgery applications.
- 1 March 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (03) , 1-12
Open AccessIn vivo photoacoustic imaging of swine ureters injected with methylene blue
SignificanceUreteral injuries represent a major concern during a range of surgical procedures, due to the proximity of the ureter to target surgical structures. Intraoperative identification of the ureter is critical to prevent this accidental damage.AimWe demonstrate the first known in vivo photoacoustic imaging of the ureter in swine following intravenous administration of FDA-approved methylene blue, enabled by a software-hardware integration that has not been previously reported in the literature.ApproachPhotoacoustic channel data from the ureters of two swine were acquired using a Vevo F2 ultrasound system and an Opotek Phocus Mobile laser. Images were beamformed using a delay-and-sum algorithm. Photoacoustic image quality was evaluated using contrast, signal-to-noise ratio (SNR), and generalized contrast-to-noise ratio (gCNR) metrics, measured 10 to 80 min after methylene blue injection.ResultsAcross the 10- to 80-min imaging window, median contrast (3.46–11.43 dB), SNR (2.84–6.99), and gCNR (0.27–0.64) confirmed sustained ureter visibility with methylene blue. Maximum image quality was observed 20- to 30-min after methylene blue injection, with significantly higher contrast, SNR, and gCNR values compared with earlier or later time points (p<0.05).ConclusionsIn vivo results demonstrate that methylene-blue-enhanced photoacoustic imaging can visualize the ureter over a time duration that is consistent with the length of surgical procedures, providing initial feasibility for real-time photoacoustic-guided surgery applications.
- Top Cited PapersOpen Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (1) , 417-431
In Vivo Demonstration of Deep Learning-Based Photoacoustic Visual Servoing System
Objective: To develop the first known deep learning-based photoacoustic visual servoing system utilizing point source localization and hybrid position-force control to track catheter tips in three dimensions in real-time. Methods: We integrated either object detection or instance segmentation-based localization with hybrid position-force control to create our novel system. Cardiac catheter tips were then tracked across distances of 40 mm in a plastisol phantom and 25-64 mm in an in vivo swine in real-time in nine visual servoing trials total. Results: Object detection-based localization identified the cardiac catheter tip in 88.0-91.7% and 66.7-70.4% of phantom and in vivo channel data frames, respectively. Instance segmentation detection rates ranged 86.4-100.0% in vivo. These catheter tips were tracked with errors as low as 0.5 mm in phantom trials and 0.8 mm in the in vivo trials. The mean inference times were ≥145.3 ms and ≥516.3 ms with object detection-based and instance segmentation-based point source localization, respectively. Hybrid position-force control system enabled contact with the imaging surface during ≥99.43% of each visual servoing trial. Conclusion: Our novel deep learning-based photoacoustic visual servoing system was successfully demonstrated. Object detectionbased localization operated with inference times that are more suitable for real-time implementations while instance segmentation had lower tracking errors. Significance: After implementing suggested optimization modifications, our novel system has the potential to track catheter tips, needle tips, and other surgical tool tips in real-time during surgical and interventional procedures.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (1) , 417-431
Top Cited PapersOpen AccessIn Vivo Demonstration of Deep Learning-Based Photoacoustic Visual Servoing System
Objective: To develop the first known deep learning-based photoacoustic visual servoing system utilizing point source localization and hybrid position-force control to track catheter tips in three dimensions in real-time. Methods: We integrated either object detection or instance segmentation-based localization with hybrid position-force control to create our novel system. Cardiac catheter tips were then tracked across distances of 40 mm in a plastisol phantom and 25-64 mm in an in vivo swine in real-time in nine visual servoing trials total. Results: Object detection-based localization identified the cardiac catheter tip in 88.0-91.7% and 66.7-70.4% of phantom and in vivo channel data frames, respectively. Instance segmentation detection rates ranged 86.4-100.0% in vivo. These catheter tips were tracked with errors as low as 0.5 mm in phantom trials and 0.8 mm in the in vivo trials. The mean inference times were ≥145.3 ms and ≥516.3 ms with object detection-based and instance segmentation-based point source localization, respectively. Hybrid position-force control system enabled contact with the imaging surface during ≥99.43% of each visual servoing trial. Conclusion: Our novel deep learning-based photoacoustic visual servoing system was successfully demonstrated. Object detectionbased localization operated with inference times that are more suitable for real-time implementations while instance segmentation had lower tracking errors. Significance: After implementing suggested optimization modifications, our novel system has the potential to track catheter tips, needle tips, and other surgical tool tips in real-time during surgical and interventional procedures.
- 2 December 2025
- Published by Elsevier in Ultrasonics
- Vol. 160, 107915
Minimal angular compounding required for coherence-based sound speed estimation with plane wave ultrasound imaging
- 2 December 2025
- Published by Elsevier in Ultrasonics
- Vol. 160, 107915
Minimal angular compounding required for coherence-based sound speed estimation with plane wave ultrasound imaging
- Open Access
- 25 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. 73 (1) , 57-69
Spatial Coherence-Based Sound Speed Estimation in Plane Wave Ultrasound Imaging
A globally constant sound speed of 1540 m/s is often assumed when beamforming ultrasound images, despite variations in tissue properties that lead to heterogeneous sound speeds. As a result, the majority of local sound speeds are often misrepresented, which degrades image quality, resulting in inaccurate target depths, sizes, and shapes, thus reducing the overall effectiveness of diagnostic and interventional ultrasound imaging. In this paper, we introduce a spatial coherence-based approach to estimate local sound speeds within and surrounding coherent and incoherent targets in ultrasound images acquired with multiple plane wave transmissions. Ultrasound data with known ground truth sound speeds were simulated. “Optimal" sound speeds produced the lowest possible lateral full width at half maximum (FWHM) of point targets, the lowest possible contrast of hypoechoic or anechoic targets, or the highest possible contrast of hyperechoic targets, serving as the ground truth sound speed for experimental data. With our proposed method, sound speeds achieved 99.68% to 100% agreement with the simulated ground truth value. When benchmarked against the optimal sound speeds, our coherence-based method yielded 0.58% and 0.56% mean deviations from optimal sound speeds in tissue-mimicking phantom data and in vivo breast data, respectively, whereas a speckle brightness maximization approach produced larger deviations of 2.50% and 3.41%, respectively. Qualitatively, B-mode images created with coherence-based sound speeds improved lateral FWHM, enhanced contrast, reduced acoustic clutter, better delineated target boundaries, and better defined speckle patterns. These results promise to improve accuracy and enhance the effectiveness of diagnostic and interventional ultrasound procedures.
- 25 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. 73 (1) , 57-69
Open AccessSpatial Coherence-Based Sound Speed Estimation in Plane Wave Ultrasound Imaging
A globally constant sound speed of 1540 m/s is often assumed when beamforming ultrasound images, despite variations in tissue properties that lead to heterogeneous sound speeds. As a result, the majority of local sound speeds are often misrepresented, which degrades image quality, resulting in inaccurate target depths, sizes, and shapes, thus reducing the overall effectiveness of diagnostic and interventional ultrasound imaging. In this paper, we introduce a spatial coherence-based approach to estimate local sound speeds within and surrounding coherent and incoherent targets in ultrasound images acquired with multiple plane wave transmissions. Ultrasound data with known ground truth sound speeds were simulated. “Optimal" sound speeds produced the lowest possible lateral full width at half maximum (FWHM) of point targets, the lowest possible contrast of hypoechoic or anechoic targets, or the highest possible contrast of hyperechoic targets, serving as the ground truth sound speed for experimental data. With our proposed method, sound speeds achieved 99.68% to 100% agreement with the simulated ground truth value. When benchmarked against the optimal sound speeds, our coherence-based method yielded 0.58% and 0.56% mean deviations from optimal sound speeds in tissue-mimicking phantom data and in vivo breast data, respectively, whereas a speckle brightness maximization approach produced larger deviations of 2.50% and 3.41%, respectively. Qualitatively, B-mode images created with coherence-based sound speeds improved lateral FWHM, enhanced contrast, reduced acoustic clutter, better delineated target boundaries, and better defined speckle patterns. These results promise to improve accuracy and enhance the effectiveness of diagnostic and interventional ultrasound procedures.
- Open Access
- 1 May 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (05) , 056008-18
Motion-based dynamic light delivery to minimize laser-related thermal damage while preserving photoacoustic image quality
Photoacoustic imaging has consistently showcased its ability to provide significant physiological insight from biological tissue in preclinical settings.1 – 3 This progress promises new possibilities to integrate photoacoustic technology into surgical guidance systems to enhance intraoperative decisions.4 Nanosecond pulses of laser light exposed to photoabsorbers within tissue cause local optical absorption followed by milliKelvin temperature increases that trigger thermal expansion followed by contraction. Light delivery to surgical sites can be achieved by coupling fiber optics to ultrasound receivers,5 positioning light at fixed distances from the receiver,6 or attaching optical fibers to surgical tools.7,8 The common feature among these approaches is a fixed light source (relative to the ultrasound receiver or surgical tool), resulting in what we refer to as stationary light delivery. A handheld light source can also be subtly operated within a narrow surgical window, which is also considered “stationary” light delivery (relative to other components that experience more motion).
- 1 May 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (05) , 056008-18
Open AccessMotion-based dynamic light delivery to minimize laser-related thermal damage while preserving photoacoustic image quality
Photoacoustic imaging has consistently showcased its ability to provide significant physiological insight from biological tissue in preclinical settings.1 – 3 This progress promises new possibilities to integrate photoacoustic technology into surgical guidance systems to enhance intraoperative decisions.4 Nanosecond pulses of laser light exposed to photoabsorbers within tissue cause local optical absorption followed by milliKelvin temperature increases that trigger thermal expansion followed by contraction. Light delivery to surgical sites can be achieved by coupling fiber optics to ultrasound receivers,5 positioning light at fixed distances from the receiver,6 or attaching optical fibers to surgical tools.7,8 The common feature among these approaches is a fixed light source (relative to the ultrasound receiver or surgical tool), resulting in what we refer to as stationary light delivery. A handheld light source can also be subtly operated within a narrow surgical window, which is also considered “stationary” light delivery (relative to other components that experience more motion).
- Open Access
- 1 July 2024
- Published by SPIE-Intl Soc Optical Eng in Biophotonics Discovery
- Vol. 1 (02) , 025003-18
Predictive model for laser-induced tissue necrosis with immunohistochemistry validation
Photoacoustic imaging is a beneficial technology that integrates the advantages of ultrasound and optical imaging. Structures with high optical absorption coefficients absorb light, leading to a localized temperature rise that generates thermal expansion. This expansion results in tissue relaxation and the subsequent isotropic release of acoustic waves, which are ultimately detected by ultrasound sensors. The broad range of targets that can be effectively imaged using photoacoustic imaging has been highlighted in many reports, positioning it as a valuable tool for surgical guidance.1 – 4
- 1 July 2024
- Published by SPIE-Intl Soc Optical Eng in Biophotonics Discovery
- Vol. 1 (02) , 025003-18
Open AccessPredictive model for laser-induced tissue necrosis with immunohistochemistry validation
Photoacoustic imaging is a beneficial technology that integrates the advantages of ultrasound and optical imaging. Structures with high optical absorption coefficients absorb light, leading to a localized temperature rise that generates thermal expansion. This expansion results in tissue relaxation and the subsequent isotropic release of acoustic waves, which are ultimately detected by ultrasound sensors. The broad range of targets that can be effectively imaged using photoacoustic imaging has been highlighted in many reports, positioning it as a valuable tool for surgical guidance.1 – 4
- 28 July 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (8) , 4349-4368
Flexible array transducer for photoacoustic-guided interventions: phantom and ex vivo demonstrations
Photoacoustic imaging has demonstrated recent promise for surgical guidance, enabling visualization of tool tips during surgical and non-surgical interventions. To receive photoacoustic signals, most conventional transducers are rigid, while a flexible array is able to deform and provide complete contact on surfaces with different geometries. In this work, we present photoacoustic images acquired with a flexible array transducer in multiple concave shapes in phantom and ex vivo bovine liver experiments targeted toward interventional photoacoustic applications. We validate our image reconstruction equations for known sensor geometries with simulated data, and we provide empirical elevation field-of-view, target position, and image quality measurements. The elevation field-of-view was 6.08 mm at a depth of 4 cm and greater than 13 mm at a depth of 5 cm. The target depth agreement with ground truth ranged 98.35-99.69%. The mean lateral and axial target sizes when imaging 600 μm-core-diameter optical fibers inserted within the phantoms ranged 0.98-2.14 mm and 1.61-2.24 mm, respectively. The mean ± one standard deviation of lateral and axial target sizes when surrounded by liver tissue were 1.80±0.48 mm and 2.17±0.24 mm, respectively. Contrast, signal-to-noise, and generalized contrast-to-noise ratios ranged 6.92–24.42 dB, 46.50–67.51 dB, and 0.76–1, respectively, within the elevational field-of-view. Results establish the feasibility of implementing photoacoustic-guided surgery with a flexible array transducer.
- 28 July 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (8) , 4349-4368
Flexible array transducer for photoacoustic-guided interventions: phantom and ex vivo demonstrations
Photoacoustic imaging has demonstrated recent promise for surgical guidance, enabling visualization of tool tips during surgical and non-surgical interventions. To receive photoacoustic signals, most conventional transducers are rigid, while a flexible array is able to deform and provide complete contact on surfaces with different geometries. In this work, we present photoacoustic images acquired with a flexible array transducer in multiple concave shapes in phantom and ex vivo bovine liver experiments targeted toward interventional photoacoustic applications. We validate our image reconstruction equations for known sensor geometries with simulated data, and we provide empirical elevation field-of-view, target position, and image quality measurements. The elevation field-of-view was 6.08 mm at a depth of 4 cm and greater than 13 mm at a depth of 5 cm. The target depth agreement with ground truth ranged 98.35-99.69%. The mean lateral and axial target sizes when imaging 600 μm-core-diameter optical fibers inserted within the phantoms ranged 0.98-2.14 mm and 1.61-2.24 mm, respectively. The mean ± one standard deviation of lateral and axial target sizes when surrounded by liver tissue were 1.80±0.48 mm and 2.17±0.24 mm, respectively. Contrast, signal-to-noise, and generalized contrast-to-noise ratios ranged 6.92–24.42 dB, 46.50–67.51 dB, and 0.76–1, respectively, within the elevational field-of-view. Results establish the feasibility of implementing photoacoustic-guided surgery with a flexible array transducer.