SCSteven M. Conolly

Steven M. Conolly

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Steven M. Conolly has a total of 134 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Physicochemical Necessary and Sufficient Conditions for Superferromagnetism in High‐Resolution Magnetic Particle Imaging

    by Chinmoy Saayujya, Benjamin Fellows, Yifeng Shi, Ruhani Sagar, Benjamin G. Cary, Jacob Bryan, Cherilyn Yu, Melissa Kim, Allison Hartley, Quincy Huynh, et al.

    Magnetic Particle Imaging (MPI) is a novel tracer modality that images the spatial distribution of superparamagnetic iron oxide nanoparticles (SPIOs) by exploiting their nonlinear response to magnetic fields. MPI image resolution is primarily influenced by the strength of the MPI gradient field and the physical and magnetic properties of the nanoparticle tracers. Although MPI offers exceptional sensitivity, contrast, and penetration depth, its spatial resolution remains limited, particularly in clinical systems due to safety limits on gradient field strength. Consequently, efforts to improve resolution focus on developing MPI‐tailored tracers with enhanced magnetic resolution. This work explores the effects of strong dipole‐dipole coupling between SPIOs in linear chain‐like structures. This leads to the observation of superferromagnetism, a phenomenon in which assemblies of superparamagnetic nanoparticles exhibit transient magnetic behavior similar to ferromagnetism. This transition is associated with order‐of‐magnitude improvements in resolution and sensitivity. The influlence of these interactions on the magnetization curve is analyzed using a positive feedback model, and experimental observations such as coercivity are successfully predicted. The necessary conditions for the observation of superferromagnetism suggested by the theory are also experimentally validated. The positive feedback model is found to be an indispensable tool for the synthesis of high‐resolution MPI tracers, optimizing core size, oxidation state, and coating.


  • Open Access

    Roadmap on magnetic nanoparticles in nanomedicine

    by Kai Wu, Jian-Ping Wang, Niranjan A Natekar, Stefano Ciannella, Cristina González-Fernández, Jenifer Gomez-Pastora, Yuping Bao, Jinming Liu, Shuang Liang, Xian Wu, et al.

    Magnetic nanoparticles (MNPs) represent a class of small particles typically with diameters ranging from 1 to 100 nanometers. These nanoparticles are composed of magnetic materials such as iron, cobalt, nickel, or their alloys. The nanoscale size of MNPs gives them unique physicochemical (physical and chemical) properties not found in their bulk counterparts. Their versatile nature and unique magnetic behavior make them valuable in a wide range of scientific, medical, and technological fields. Over the past decade, there has been a significant surge in MNP-based applications spanning biomedical uses, environmental remediation, data storage, energy storage, and catalysis. Given their magnetic nature and small size, MNPs can be manipulated and guided using external magnetic fields. This characteristic is harnessed in biomedical applications, where these nanoparticles can be directed to specific targets in the body for imaging, drug delivery, or hyperthermia treatment. Herein, this roadmap offers an overview of the current status, challenges, and advancements in various facets of MNPs. It covers magnetic properties, synthesis, functionalization, characterization, and biomedical applications such as sample enrichment, bioassays, imaging, hyperthermia, neuromodulation, tissue engineering, and drug/gene delivery. However, as MNPs are increasingly explored for in vivo applications, concerns have emerged regarding their cytotoxicity, cellular uptake, and degradation, prompting attention from both researchers and clinicians. This roadmap aims to provide a comprehensive perspective on the evolving landscape of MNP research.


  • Active Cancellation of Direct Feedthrough Enables 100-fold More Sensitive Mass-Limited Detection in Magnetic Particle Sensing Systems

    by Quincy Huynh, Owen Doyle, K.L Barry Fung, Chinmoy Saayujya, Steven Conolly

    Magnetic particle imaging (MPI) is a tracer imaging modality that detects superparamagnetic iron oxide nanoparticles (SPIOs), enabling sensitive, radiation-free imaging of cells and disease pathologies. The arbitrary waveform relaxometer (AWR) is an indispensable platform for developing magnetic nanoparticle tracers and evaluating tracer performance for magnetic particle imaging applications. One of the biggest challenges in arbitrary waveform excitation is direct feedthrough interference, which is usually six orders of magnitude larger than the signal from magnetic nanoparticles. This work will showcase hardware that suppresses this interference by an order of magnitude, increasing the dynamic range of the instrument and enabling mass-limited detection at full scale range.

  • Open Access

    Temperature-Dependent Changes in Resolution and Coercivity of Superparamagnetic and Superferromagnetic Iron Oxide Nanoparticles

    by Owen Doyle, Jacob Bryan, Melissa Kim, Chinmoy Saayujya, Sophie Nazarian, Javier Mokkarala-Lopez, Renesmee Kuo, Mariam Yousuf, Prashant Chandrasekharan, Benjamin Fellows, et al.

    Magnetic Particle Imaging (MPI) is a tracer-based imaging modality with immense promise as a radiation-free alternative to nuclear medicine imaging techniques. Nuclear medicine requires “hot chemistry” wherein radioactive tracers must be synthesized on-site, requiring expensive infrastructure and labor costs. MPI’s magnetic nanoparticles, superparamagnetic iron oxide nanoparticles (SPIOs), have no significant signal decay over time which removes cost barriers associated with nuclear medicine studies such as FDG-PET. While SPIOs are the current industry standard MPI tracer, recent developments in synthesizing superferromagnetic iron oxide nanoparticles (SFMIOs) and high resolution SPIOs (HR-SPIOs), a new class of nanoparticle with almost zero coercivity, have yielded a 30-fold improvement in resolution (0.4 mT) and SNR. To better understand the long-term performance of these new nanoparticles, this investigation reports changes in SPIO (VivoTrax Plus), HR-SPIO, and SFMIO resolution, along with SFMIO coercivity, at low temperatures (−2, 2 °C) and room temperature (18–22 °C) over 12 weeks. We find that changes in HR-SPIO resolution are more sensitive to storage temperature than SFMIOs. Additionally, we observe no appreciable difference in SFMIO coercivity between the two temperatures over time. These results can inform research on optimizing tracer synthesis while lending practical information to future hospitals about the highly accessible conditions for the transit and storage of tracers.


  • Open Access

    Magnetic Particle Imaging in Vascular Imaging, Immunotherapy, Cell Tracking, and Noninvasive Diagnosis

    by Prashant Chandrasekharan, Renesmee Kuo, K. L. Barry Fung, Chinmoy Saayujya, Jacob Bryan, Mariam Yousuf, Benjamin Fellows, Caylin Colson, Quincy Huynh, Owen Doyle, et al.

    Magnetic particle imaging (MPI) is a new tracer-based imaging modality that is useful in diagnosing various pathophysiology related to the vascular system and for sensitive tracking of cytotherapies. MPI uses nonradioactive and easily assimilated nanometer-sized iron oxide particles as tracers. MPI images the nonlinear Langevin behavior of the iron oxide particles and has allowed for the sensitive detection of iron oxide-labeled therapeutic cells in the body. This review will provide an overview of MPI technology, the tracer, and its use in vascular imaging and cytotherapies using molecular targets.


  • Open Access

    Magnetic Particle Imaging: An Emerging Modality with Prospects in Diagnosis, Targeting and Therapy of Cancer

    by Zhi Wei Tay, Prashant Chandrasekharan, Benjamin D. Fellows, Irati Rodrigo Arrizabalaga, Elaine Yu, Malini Olivo, Steven M. Conolly

    Background: Magnetic Particle Imaging (MPI) is an emerging imaging modality for quantitative direct imaging of superparamagnetic iron oxide nanoparticles (SPION or SPIO). With different physics from MRI, MPI benefits from ideal image contrast with zero background tissue signal. This enables clear visualization of cancer with image characteristics similar to PET or SPECT, but using radiation-free magnetic nanoparticles instead, with infinite-duration reporter persistence in vivo. MPI for cancer imaging: demonstrated months of quantitative imaging of the cancer-related immune response with in situ SPION-labelling of immune cells (e.g., neutrophils, CAR T-cells). Because MPI suffers absolutely no susceptibility artifacts in the lung, immuno-MPI could soon provide completely noninvasive early-stage diagnosis and treatment monitoring of lung cancers. MPI for magnetic steering: MPI gradients are ~150 × stronger than MRI, enabling remote magnetic steering of magneto-aerosol, nanoparticles, and catheter tips, enhancing therapeutic delivery by magnetic means. MPI for precision therapy: gradients enable focusing of magnetic hyperthermia and magnetic-actuated drug release with up to 2 mm precision. The extent of drug release from the magnetic nanocarrier can be quantitatively monitored by MPI of SPION’s MPS spectral changes within the nanocarrier. Conclusion: MPI is a promising new magnetic modality spanning cancer imaging to guided-therapy.


  • Open Access

    Combining magnetic particle imaging and magnetic fluid hyperthermia for localized and image-guided treatment

    by Yao Lu, Angelie Rivera-Rodriguez, Zhi Wei Tay, Daniel Hensley, K.L. Barry Fung, Caylin Colson, Chinmoy Saayujya, Quincy Huynh, Leyla Kabuli, Benjamin Fellows, et al.

    Magnetic fluid hyperthermia (MFH) has been widely investigated as a treatment tool for cancer and other diseases. However, focusing traditional MFH to a tumor deep in the body is not feasible because the in vivo wavelength of 300 kHz very low frequency (VLF) excitation fields is longer than 100 m. Recently we demonstrated that millimeter-precision localized heating can be achieved by combining magnetic particle imaging (MPI) with MFH. In principle, real-time MPI imaging can also guide the location and dosing of MFH treatments. Hence, the combination of MPI imaging plus real time localized MPI–MFH could soon permit closed-loop high-resolution hyperthermia treatment. In this review, we will discuss the fundamentals of localized MFH (e.g. physics and biosafety limitations), hardware implementation, MPI real-time guidance, and new research directions on MPI–MFH. We will also discuss how the scale up to human-sized MPI–MFH scanners could proceed.


  • Open Access

    A Review of Magnetic Particle Imaging and Perspectives on Neuroimaging

    by L.C. Wu, Y. Zhang, G. Steinberg, H. Qu, S. Huang, M. Cheng, T. Bliss, F. Du, J. Rao, G. Song, et al.

    SUMMARY: Magnetic particle imaging is an emerging tomographic technique with the potential for simultaneous high-resolution, high-sensitivity, and real-time imaging. Magnetic particle imaging is based on the unique behavior of superparamagnetic iron oxide nanoparticles modeled by the Langevin theory, with the ability to track and quantify nanoparticle concentrations without tissue background noise. It is a promising new imaging technique for multiple applications, including vascular and perfusion imaging, oncology imaging, cell tracking, inflammation imaging, and trauma imaging. In particular, many neuroimaging applications may be enabled and enhanced with magnetic particle imaging. In this review, we will provide an overview of magnetic particle imaging principles and implementation, current applications, promising neuroimaging applications, and practical considerations.


  • Optimal Broadband Noise Matching to Inductive Sensors: Application to Magnetic Particle Imaging

    by Bo Zheng, Patrick W. Goodwill, Neerav Dixit, Di Xiao, Wencong Zhang, Beliz Gunel, Kuan Lu, Greig C. Scott, Steven M. Conolly

    Inductive sensor-based measurement techniques are useful for a wide range of biomedical applications. However, optimizing the noise performance of these sensors is challenging at broadband frequencies, owing to the frequency-dependent reactance of the sensor. In this work, we describe the fundamental limits of noise performance and bandwidth for these sensors in combination with a low-noise amplifier. We also present three equivalent methods of noise matching to inductive sensors using transformer-like network topologies. Finally, we apply these techniques to improve the noise performance in magnetic particle imaging, a new molecular imaging modality with excellent detection sensitivity. Using a custom noise-matched amplifier, we experimentally demonstrate an 11-fold improvement in noise performance in a small animal magnetic particle imaging scanner.


  • First in vivo traumatic brain injury imaging via magnetic particle imaging

    by Ryan Orendorff, Austin J Peck, Bo Zheng, Shawn N Shirazi, R Matthew Ferguson, Amit P Khandhar, Scott J Kemp, Patrick Goodwill, Kannan M Krishnan, George A Brooks, et al.

    Emergency room visits due to traumatic brain injury (TBI) is common, but classifying the severity of the injury remains an open challenge. Some subjective methods such as the Glasgow Coma Scale attempt to classify traumatic brain injuries, as well as some imaging based modalities such as computed tomography and magnetic resonance imaging. However, to date it is still difficult to detect and monitor mild to moderate injuries. In this report, we demonstrate that the magnetic particle imaging (MPI) modality can be applied to imaging TBI events with excellent contrast. MPI can monitor injected iron nanoparticles over long time scales without signal loss, allowing researchers and clinicians to monitor the change in blood pools as the wound heals.