Chinmoy Saayujya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Chinmoy Saayujya has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
- Benjamin Fellows
Magnetic Insight Inc., Alameda, CA, USA
5 shared publications - Steven M. Conolly
Affiliations: Department of Bioengineering, University of California, Berkeley, CA, United States of America, Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA, United States of America
5 shared publications - Owen Doyle
University of California, Berkeley,Department of Bioengineering,Berkeley,CA,USA
3 shared publications - Prashant Chandrasekharan
Department of Bioengineering University of California Berkeley CA 94720 USA
3 shared publications - Quincy Huynh
University of California
3 shared publications Allison Hartley
Department of Bioengineering University of California Berkeley 94720 California USA
2 shared publications
Latest Publications
- Open Access
- 20 January 2026
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 18 (6) , 3018-3031
Magnetic particle imaging lymphography (MPIL): a technique for lymph node mapping
During metastasis, tumour cells drain to nearby lymph nodes, the first of which are named the sentinel lymph node(s) (SLN). SLN biopsy (SLNB) determines if metastasis has occurred. Traditionally, SLNB involves injecting a technetium-labeled tracer peritumorally, pre-operative imaging with SPECT to locate the SLN, and surgery guided by a gamma probe to remove them. Limitations include a short tracer half-life, which can make scheduling the SLNB difficult, and radiation exposure to patients and healthcare workers. Alternatively, magnetic localization, with superparamagnetic iron oxide nanoparticles (SPIONs) as the tracer and a magnetometer to detect SPIONs in the SLN during surgery, can be used; however, this lacks pre-operative imaging capability. Magnetic Particle Imaging (MPI) is an emerging imaging modality that directly detects SPIONs, holding potential for pre-operative imaging in magnetic SLNB. SPIONs for SLNB should have rapid drainage, high SLN accumulation, and high specificity to the SLN. For MPI Lymphography (MPIL), high particle sensitivity is also important. This study assesses the in vivo pharmacokinetics for SLN mapping with MPIL in a murine model, using five commercially available SPIONs of varying iron core sizes and surface coatings (VivoTrax, VivoTrax+, Synomag-D70, Synomag-D70 PEG and Synomag-D70 PEG-mannose). Our results show that the peak MPI signal measured for different SPIONs using relaxometry does not necessarily predict the MPI signal measured in vivo from images and that both the core size and the hydrodynamic size contribute to the performance of SPIONs as tracers for MPIL. VivoTrax+ had a higher peak signal measured by relaxometry (more ideal core size) but a lower MPI signal in vivo in the SLN (less accumulation in the SLN due to hydrodynamic size). Synomag-D70 had a 2.5 times higher peak signal compared to VivoTrax as measured by relaxometry, a 2–3 times higher signal in vivo in the SLN at early timepoints, and a 5–6 times higher signal in vivo at the latest timepoint. This suggests similar SLN accumulation at early timepoints and higher accumulation at the late timepoint. Synomag-D70 PEG and Synomag-D70 PEG-mannose had more rapid clearance from the injection site compared to plain Synomag. The MPI signal was detected in higher echelon nodes (HENs) for all Synomag particles, with Synomag-D70 PEG-mannose having the lowest HEN signal at 24 hours. Overall, the mannose targeted version of Synomag met more of the criteria for what is considered a good tracer for SLNB, with higher clearance, accumulation and specificity compared to the other SPIONs tested in this study.
- 20 January 2026
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 18 (6) , 3018-3031
Open AccessMagnetic particle imaging lymphography (MPIL): a technique for lymph node mapping
During metastasis, tumour cells drain to nearby lymph nodes, the first of which are named the sentinel lymph node(s) (SLN). SLN biopsy (SLNB) determines if metastasis has occurred. Traditionally, SLNB involves injecting a technetium-labeled tracer peritumorally, pre-operative imaging with SPECT to locate the SLN, and surgery guided by a gamma probe to remove them. Limitations include a short tracer half-life, which can make scheduling the SLNB difficult, and radiation exposure to patients and healthcare workers. Alternatively, magnetic localization, with superparamagnetic iron oxide nanoparticles (SPIONs) as the tracer and a magnetometer to detect SPIONs in the SLN during surgery, can be used; however, this lacks pre-operative imaging capability. Magnetic Particle Imaging (MPI) is an emerging imaging modality that directly detects SPIONs, holding potential for pre-operative imaging in magnetic SLNB. SPIONs for SLNB should have rapid drainage, high SLN accumulation, and high specificity to the SLN. For MPI Lymphography (MPIL), high particle sensitivity is also important. This study assesses the in vivo pharmacokinetics for SLN mapping with MPIL in a murine model, using five commercially available SPIONs of varying iron core sizes and surface coatings (VivoTrax, VivoTrax+, Synomag-D70, Synomag-D70 PEG and Synomag-D70 PEG-mannose). Our results show that the peak MPI signal measured for different SPIONs using relaxometry does not necessarily predict the MPI signal measured in vivo from images and that both the core size and the hydrodynamic size contribute to the performance of SPIONs as tracers for MPIL. VivoTrax+ had a higher peak signal measured by relaxometry (more ideal core size) but a lower MPI signal in vivo in the SLN (less accumulation in the SLN due to hydrodynamic size). Synomag-D70 had a 2.5 times higher peak signal compared to VivoTrax as measured by relaxometry, a 2–3 times higher signal in vivo in the SLN at early timepoints, and a 5–6 times higher signal in vivo at the latest timepoint. This suggests similar SLN accumulation at early timepoints and higher accumulation at the late timepoint. Synomag-D70 PEG and Synomag-D70 PEG-mannose had more rapid clearance from the injection site compared to plain Synomag. The MPI signal was detected in higher echelon nodes (HENs) for all Synomag particles, with Synomag-D70 PEG-mannose having the lowest HEN signal at 24 hours. Overall, the mannose targeted version of Synomag met more of the criteria for what is considered a good tracer for SLNB, with higher clearance, accumulation and specificity compared to the other SPIONs tested in this study.
- Open Access
Physicochemical Necessary and Sufficient Conditions for Superferromagnetism in High‐Resolution Magnetic Particle Imaging
Magnetic Particle Imaging (MPI) is a novel tracer modality that images the spatial distribution of superparamagnetic iron oxide nanoparticles (SPIOs) by exploiting their nonlinear response to magnetic fields. MPI image resolution is primarily influenced by the strength of the MPI gradient field and the physical and magnetic properties of the nanoparticle tracers. Although MPI offers exceptional sensitivity, contrast, and penetration depth, its spatial resolution remains limited, particularly in clinical systems due to safety limits on gradient field strength. Consequently, efforts to improve resolution focus on developing MPI‐tailored tracers with enhanced magnetic resolution. This work explores the effects of strong dipole‐dipole coupling between SPIOs in linear chain‐like structures. This leads to the observation of superferromagnetism, a phenomenon in which assemblies of superparamagnetic nanoparticles exhibit transient magnetic behavior similar to ferromagnetism. This transition is associated with order‐of‐magnitude improvements in resolution and sensitivity. The influlence of these interactions on the magnetization curve is analyzed using a positive feedback model, and experimental observations such as coercivity are successfully predicted. The necessary conditions for the observation of superferromagnetism suggested by the theory are also experimentally validated. The positive feedback model is found to be an indispensable tool for the synthesis of high‐resolution MPI tracers, optimizing core size, oxidation state, and coating.
Open AccessPhysicochemical Necessary and Sufficient Conditions for Superferromagnetism in High‐Resolution Magnetic Particle Imaging
Magnetic Particle Imaging (MPI) is a novel tracer modality that images the spatial distribution of superparamagnetic iron oxide nanoparticles (SPIOs) by exploiting their nonlinear response to magnetic fields. MPI image resolution is primarily influenced by the strength of the MPI gradient field and the physical and magnetic properties of the nanoparticle tracers. Although MPI offers exceptional sensitivity, contrast, and penetration depth, its spatial resolution remains limited, particularly in clinical systems due to safety limits on gradient field strength. Consequently, efforts to improve resolution focus on developing MPI‐tailored tracers with enhanced magnetic resolution. This work explores the effects of strong dipole‐dipole coupling between SPIOs in linear chain‐like structures. This leads to the observation of superferromagnetism, a phenomenon in which assemblies of superparamagnetic nanoparticles exhibit transient magnetic behavior similar to ferromagnetism. This transition is associated with order‐of‐magnitude improvements in resolution and sensitivity. The influlence of these interactions on the magnetization curve is analyzed using a positive feedback model, and experimental observations such as coercivity are successfully predicted. The necessary conditions for the observation of superferromagnetism suggested by the theory are also experimentally validated. The positive feedback model is found to be an indispensable tool for the synthesis of high‐resolution MPI tracers, optimizing core size, oxidation state, and coating.
- Open Access
Magnetic Particle Imaging Lymphography (MPIL): A novel technique for lymph node mapping
During metastasis, tumour cells drain to nearby lymph nodes, the first of which are named the sentinel lymph node(s) (SLN). SLN biopsy (SLNB) determines if metastasis has occurred. Traditionally, SLNB involves injecting a Technetium-labeled tracer peritumourally, pre-operative imaging with SPECT to locate the SLN, and surgery guided by a gamma probe to remove them. Limitations include short tracer half-life which can make scheduling the SLNB difficult, and radiation dose to patients and healthcare workers. Alternatively, magnetic localization, with superparamagnetic iron oxide nanoparticles (SPIONs) as the tracer and a magnetometer to detect SPIONs in the SLN during surgery can be used, however, this lacks pre-operative imaging. Magnetic Particle Imaging (MPI) is a new imaging modality that directly detects SPIONs, holding potential for pre-operative imaging in magnetic SLNB. SPIONs for SLNB should have rapid drainage, high SLN accumulation, and high specificity to the SLN. For MPI Lymphography (MPIL), high particle sensitivity is also important. This study assesses the in vivo pharmacokinetics for SLN mapping with MPIL in a murine model, using five commercially available SPIONs of varying iron core sizes and surface coatings. We show that some SPIONs provide higher MPI signal at the SLN and show the potential to detect higher echelon nodes (HENs). PEGylation of SPIONs and mannose targeted SPIONs increase clearance from the injection site and the mannose targeted SPION reduces flow to HENs.
Open AccessMagnetic Particle Imaging Lymphography (MPIL): A novel technique for lymph node mapping
During metastasis, tumour cells drain to nearby lymph nodes, the first of which are named the sentinel lymph node(s) (SLN). SLN biopsy (SLNB) determines if metastasis has occurred. Traditionally, SLNB involves injecting a Technetium-labeled tracer peritumourally, pre-operative imaging with SPECT to locate the SLN, and surgery guided by a gamma probe to remove them. Limitations include short tracer half-life which can make scheduling the SLNB difficult, and radiation dose to patients and healthcare workers. Alternatively, magnetic localization, with superparamagnetic iron oxide nanoparticles (SPIONs) as the tracer and a magnetometer to detect SPIONs in the SLN during surgery can be used, however, this lacks pre-operative imaging. Magnetic Particle Imaging (MPI) is a new imaging modality that directly detects SPIONs, holding potential for pre-operative imaging in magnetic SLNB. SPIONs for SLNB should have rapid drainage, high SLN accumulation, and high specificity to the SLN. For MPI Lymphography (MPIL), high particle sensitivity is also important. This study assesses the in vivo pharmacokinetics for SLN mapping with MPIL in a murine model, using five commercially available SPIONs of varying iron core sizes and surface coatings. We show that some SPIONs provide higher MPI signal at the SLN and show the potential to detect higher echelon nodes (HENs). PEGylation of SPIONs and mannose targeted SPIONs increase clearance from the injection site and the mannose targeted SPION reduces flow to HENs.
- Open Access
- 5 November 2024
- Published by IOP Publishing in Nanotechnology
- Vol. 36 (4) , 042003
Roadmap on magnetic nanoparticles in nanomedicine
Magnetic nanoparticles (MNPs) represent a class of small particles typically with diameters ranging from 1 to 100 nanometers. These nanoparticles are composed of magnetic materials such as iron, cobalt, nickel, or their alloys. The nanoscale size of MNPs gives them unique physicochemical (physical and chemical) properties not found in their bulk counterparts. Their versatile nature and unique magnetic behavior make them valuable in a wide range of scientific, medical, and technological fields. Over the past decade, there has been a significant surge in MNP-based applications spanning biomedical uses, environmental remediation, data storage, energy storage, and catalysis. Given their magnetic nature and small size, MNPs can be manipulated and guided using external magnetic fields. This characteristic is harnessed in biomedical applications, where these nanoparticles can be directed to specific targets in the body for imaging, drug delivery, or hyperthermia treatment. Herein, this roadmap offers an overview of the current status, challenges, and advancements in various facets of MNPs. It covers magnetic properties, synthesis, functionalization, characterization, and biomedical applications such as sample enrichment, bioassays, imaging, hyperthermia, neuromodulation, tissue engineering, and drug/gene delivery. However, as MNPs are increasingly explored for in vivo applications, concerns have emerged regarding their cytotoxicity, cellular uptake, and degradation, prompting attention from both researchers and clinicians. This roadmap aims to provide a comprehensive perspective on the evolving landscape of MNP research.
- 5 November 2024
- Published by IOP Publishing in Nanotechnology
- Vol. 36 (4) , 042003
Open AccessRoadmap on magnetic nanoparticles in nanomedicine
Magnetic nanoparticles (MNPs) represent a class of small particles typically with diameters ranging from 1 to 100 nanometers. These nanoparticles are composed of magnetic materials such as iron, cobalt, nickel, or their alloys. The nanoscale size of MNPs gives them unique physicochemical (physical and chemical) properties not found in their bulk counterparts. Their versatile nature and unique magnetic behavior make them valuable in a wide range of scientific, medical, and technological fields. Over the past decade, there has been a significant surge in MNP-based applications spanning biomedical uses, environmental remediation, data storage, energy storage, and catalysis. Given their magnetic nature and small size, MNPs can be manipulated and guided using external magnetic fields. This characteristic is harnessed in biomedical applications, where these nanoparticles can be directed to specific targets in the body for imaging, drug delivery, or hyperthermia treatment. Herein, this roadmap offers an overview of the current status, challenges, and advancements in various facets of MNPs. It covers magnetic properties, synthesis, functionalization, characterization, and biomedical applications such as sample enrichment, bioassays, imaging, hyperthermia, neuromodulation, tissue engineering, and drug/gene delivery. However, as MNPs are increasingly explored for in vivo applications, concerns have emerged regarding their cytotoxicity, cellular uptake, and degradation, prompting attention from both researchers and clinicians. This roadmap aims to provide a comprehensive perspective on the evolving landscape of MNP research.
- Open Access
Pulsed MPI Relaxometry of Brownian and Néel Field‐Dependent Relaxation in Superparamagnetic Magnetite Nanoparticles Confirm Theory and Simulations
Superparamagnetic iron oxide nanoparticles (SPIOs) are used as tracers in Magnetic Particle Imaging (MPI). It is crucial to understand the magnetic properties of SPIOs for optimizing MPI imaging contrast, resolution, and sensitivity. Brownian and Néel relaxation theory developed in the early 1950s posits that relaxation times can vary with particle size, shell thickness, medium viscosity, and the applied field strength. Magnetic relaxation can soon provide a unique imaging capability, the ability to distinguish bound from unbound MPI tracers in vivo. Yet experimental validation of these theories has not been completed. In this paper, a novel method of pulsed magnetic field relaxometry is used to directly probe the relaxation behavior of superparamagnetic magnetite nanoparticles over a spectrum of magnetic field amplitudes, providing the first experimental validation of theoretical relaxation models. It is also shown that closed‐form approximations generated in the early 1970s accurately match both data and numerical Fokker Planck computational models, which are computationally burdensome. This means researchers can trust these approximations for future modeling. All the findings can be translated to sinusoidal excitations used in conventional MPI scanning trajectories.
Open AccessPulsed MPI Relaxometry of Brownian and Néel Field‐Dependent Relaxation in Superparamagnetic Magnetite Nanoparticles Confirm Theory and Simulations
Superparamagnetic iron oxide nanoparticles (SPIOs) are used as tracers in Magnetic Particle Imaging (MPI). It is crucial to understand the magnetic properties of SPIOs for optimizing MPI imaging contrast, resolution, and sensitivity. Brownian and Néel relaxation theory developed in the early 1950s posits that relaxation times can vary with particle size, shell thickness, medium viscosity, and the applied field strength. Magnetic relaxation can soon provide a unique imaging capability, the ability to distinguish bound from unbound MPI tracers in vivo. Yet experimental validation of these theories has not been completed. In this paper, a novel method of pulsed magnetic field relaxometry is used to directly probe the relaxation behavior of superparamagnetic magnetite nanoparticles over a spectrum of magnetic field amplitudes, providing the first experimental validation of theoretical relaxation models. It is also shown that closed‐form approximations generated in the early 1970s accurately match both data and numerical Fokker Planck computational models, which are computationally burdensome. This means researchers can trust these approximations for future modeling. All the findings can be translated to sinusoidal excitations used in conventional MPI scanning trajectories.
- 19 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 6, 1-5
Active Cancellation of Direct Feedthrough Enables 100-fold More Sensitive Mass-Limited Detection in Magnetic Particle Sensing Systems
Magnetic particle imaging (MPI) is a tracer imaging modality that detects superparamagnetic iron oxide nanoparticles (SPIOs), enabling sensitive, radiation-free imaging of cells and disease pathologies. The arbitrary waveform relaxometer (AWR) is an indispensable platform for developing magnetic nanoparticle tracers and evaluating tracer performance for magnetic particle imaging applications. One of the biggest challenges in arbitrary waveform excitation is direct feedthrough interference, which is usually six orders of magnitude larger than the signal from magnetic nanoparticles. This work will showcase hardware that suppresses this interference by an order of magnitude, increasing the dynamic range of the instrument and enabling mass-limited detection at full scale range.
- 19 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 6, 1-5
Active Cancellation of Direct Feedthrough Enables 100-fold More Sensitive Mass-Limited Detection in Magnetic Particle Sensing Systems
Magnetic particle imaging (MPI) is a tracer imaging modality that detects superparamagnetic iron oxide nanoparticles (SPIOs), enabling sensitive, radiation-free imaging of cells and disease pathologies. The arbitrary waveform relaxometer (AWR) is an indispensable platform for developing magnetic nanoparticle tracers and evaluating tracer performance for magnetic particle imaging applications. One of the biggest challenges in arbitrary waveform excitation is direct feedthrough interference, which is usually six orders of magnitude larger than the signal from magnetic nanoparticles. This work will showcase hardware that suppresses this interference by an order of magnitude, increasing the dynamic range of the instrument and enabling mass-limited detection at full scale range.
- Open Access
- 19 March 2023
- Vol. 9 (1 Suppl1)
Temperature-Dependent Changes in Resolution and Coercivity of Superparamagnetic and Superferromagnetic Iron Oxide Nanoparticles
Magnetic Particle Imaging (MPI) is a tracer-based imaging modality with immense promise as a radiation-free alternative to nuclear medicine imaging techniques. Nuclear medicine requires “hot chemistry” wherein radioactive tracers must be synthesized on-site, requiring expensive infrastructure and labor costs. MPI’s magnetic nanoparticles, superparamagnetic iron oxide nanoparticles (SPIOs), have no significant signal decay over time which removes cost barriers associated with nuclear medicine studies such as FDG-PET. While SPIOs are the current industry standard MPI tracer, recent developments in synthesizing superferromagnetic iron oxide nanoparticles (SFMIOs) and high resolution SPIOs (HR-SPIOs), a new class of nanoparticle with almost zero coercivity, have yielded a 30-fold improvement in resolution (0.4 mT) and SNR. To better understand the long-term performance of these new nanoparticles, this investigation reports changes in SPIO (VivoTrax Plus), HR-SPIO, and SFMIO resolution, along with SFMIO coercivity, at low temperatures (−2, 2 °C) and room temperature (18–22 °C) over 12 weeks. We find that changes in HR-SPIO resolution are more sensitive to storage temperature than SFMIOs. Additionally, we observe no appreciable difference in SFMIO coercivity between the two temperatures over time. These results can inform research on optimizing tracer synthesis while lending practical information to future hospitals about the highly accessible conditions for the transit and storage of tracers.
- 19 March 2023
- Vol. 9 (1 Suppl1)
Open AccessTemperature-Dependent Changes in Resolution and Coercivity of Superparamagnetic and Superferromagnetic Iron Oxide Nanoparticles
Magnetic Particle Imaging (MPI) is a tracer-based imaging modality with immense promise as a radiation-free alternative to nuclear medicine imaging techniques. Nuclear medicine requires “hot chemistry” wherein radioactive tracers must be synthesized on-site, requiring expensive infrastructure and labor costs. MPI’s magnetic nanoparticles, superparamagnetic iron oxide nanoparticles (SPIOs), have no significant signal decay over time which removes cost barriers associated with nuclear medicine studies such as FDG-PET. While SPIOs are the current industry standard MPI tracer, recent developments in synthesizing superferromagnetic iron oxide nanoparticles (SFMIOs) and high resolution SPIOs (HR-SPIOs), a new class of nanoparticle with almost zero coercivity, have yielded a 30-fold improvement in resolution (0.4 mT) and SNR. To better understand the long-term performance of these new nanoparticles, this investigation reports changes in SPIO (VivoTrax Plus), HR-SPIO, and SFMIO resolution, along with SFMIO coercivity, at low temperatures (−2, 2 °C) and room temperature (18–22 °C) over 12 weeks. We find that changes in HR-SPIO resolution are more sensitive to storage temperature than SFMIOs. Additionally, we observe no appreciable difference in SFMIO coercivity between the two temperatures over time. These results can inform research on optimizing tracer synthesis while lending practical information to future hospitals about the highly accessible conditions for the transit and storage of tracers.
- Open Access
- 15 March 2023
- Published by SAGE Publications in Molecular Imaging
- Vol. 2023
Magnetic Particle Imaging in Vascular Imaging, Immunotherapy, Cell Tracking, and Noninvasive Diagnosis
Magnetic particle imaging (MPI) is a new tracer-based imaging modality that is useful in diagnosing various pathophysiology related to the vascular system and for sensitive tracking of cytotherapies. MPI uses nonradioactive and easily assimilated nanometer-sized iron oxide particles as tracers. MPI images the nonlinear Langevin behavior of the iron oxide particles and has allowed for the sensitive detection of iron oxide-labeled therapeutic cells in the body. This review will provide an overview of MPI technology, the tracer, and its use in vascular imaging and cytotherapies using molecular targets.
- 15 March 2023
- Published by SAGE Publications in Molecular Imaging
- Vol. 2023
Open AccessMagnetic Particle Imaging in Vascular Imaging, Immunotherapy, Cell Tracking, and Noninvasive Diagnosis
Magnetic particle imaging (MPI) is a new tracer-based imaging modality that is useful in diagnosing various pathophysiology related to the vascular system and for sensitive tracking of cytotherapies. MPI uses nonradioactive and easily assimilated nanometer-sized iron oxide particles as tracers. MPI images the nonlinear Langevin behavior of the iron oxide particles and has allowed for the sensitive detection of iron oxide-labeled therapeutic cells in the body. This review will provide an overview of MPI technology, the tracer, and its use in vascular imaging and cytotherapies using molecular targets.
- 1 April 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Design, fabrication and characterization of a zinc oxide thin-film piezoelectric accelerometer
Conventionally manufactured accelerometers based on piezoelectric lead zirconate titanate (PZT) have been used for decades, but integration issues hinder their application in micro-electro-mechanical systems (MEMS). Compared to PZT, zinc oxide (ZnO) has lower piezoelectricity and is not an attractive material for use in traditional bulky accelerometers due to its low sensitivity. However, ZnO has excellent compatibility with MEMS processing techniques, and furthermore, sensitivity can be enhanced by MEMS miniaturization. In this paper, we report the development of a micromachined ZnO piezoelectric thin-film accelerometer that demonstrates the feasibility of both easy integration and high sensitivity.
- 1 April 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Design, fabrication and characterization of a zinc oxide thin-film piezoelectric accelerometer
Conventionally manufactured accelerometers based on piezoelectric lead zirconate titanate (PZT) have been used for decades, but integration issues hinder their application in micro-electro-mechanical systems (MEMS). Compared to PZT, zinc oxide (ZnO) has lower piezoelectricity and is not an attractive material for use in traditional bulky accelerometers due to its low sensitivity. However, ZnO has excellent compatibility with MEMS processing techniques, and furthermore, sensitivity can be enhanced by MEMS miniaturization. In this paper, we report the development of a micromachined ZnO piezoelectric thin-film accelerometer that demonstrates the feasibility of both easy integration and high sensitivity.