Thomas Wilhein
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Thomas Wilhein has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Haidl
Institute for X-Optics, University of Applied Sciences Koblenz, Joseph-Rovan-Allee 2, Remagen 53424, Germany
2 shared publications - Aurelie Dehlinger
Technische Universität Berlin, Institut für Optik und Atomare Physik, Hardenbergstraße 36, Berlin 10623, Germany
2 shared publications - Hanna Dierks
Institute of Optics and Atomic Physics, Technische Universität Berlin, Hardenbergstraße 36, Berlin 10623, Germany
2 shared publications - Konstantin Andrianov
Institute for X-Optics, University of Applied Sciences Koblenz, Joseph-Rovan-Allee 2, Remagen 53424, Germany
2 shared publications - Lars Lühl
Institute of Optics and Atomic Physics, Technische Universität Berlin, Hardenbergstraße 36, Berlin 10623, Germany
2 shared publications - Alexander von Wezyk
Fraunhofer Institute for Laser Technology ILT, Steinbachstr. 15, 52074 Aachen, Germany
1 shared publication
Latest Publications
- Open Access
- 4 October 2019
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 52 (50) , 505202
Target materials for efficient plasma-based extreme ultraviolet sources in the range of 6 to 8 nm
In a comparative study the extreme ultraviolet (XUV) emission of laser-produced plasmas (LPP) of gadolinium (Gd), terbium (Tb), aluminum (Al), magnesium (Mg) and a magnesium–copper–gadolinium alloy (Mg65–Cu25–Gd10) targets is investigated in order to benchmark the emission potential at a wavelength of around 6.7 nm. Compared to the Gd/Tb targets, the advantage of the alloy is a reduced melting point of T m < 500 °C which leads to the option of a liquid or droplet target system as is usually used for a regenerative target concept. Theoretical considerations are presented to compare the emission potential of the four targets in direct comparison. Experimental results of the LPP are discussed with respect to the 6.x nm inband energy, which are consistent with the theoretical considerations. It is shown that the line radiators Al and Mg seem to be suitable emitters with comparable brightness to Gd- or Tb-based sources. The measured conversion efficiency of the Mg65Cu25Gd10 target reaches 80% of that of the pure Gd LPP although the Gd fraction is only 2% (atom percent).
- 4 October 2019
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 52 (50) , 505202
Open AccessTarget materials for efficient plasma-based extreme ultraviolet sources in the range of 6 to 8 nm
In a comparative study the extreme ultraviolet (XUV) emission of laser-produced plasmas (LPP) of gadolinium (Gd), terbium (Tb), aluminum (Al), magnesium (Mg) and a magnesium–copper–gadolinium alloy (Mg65–Cu25–Gd10) targets is investigated in order to benchmark the emission potential at a wavelength of around 6.7 nm. Compared to the Gd/Tb targets, the advantage of the alloy is a reduced melting point of T m < 500 °C which leads to the option of a liquid or droplet target system as is usually used for a regenerative target concept. Theoretical considerations are presented to compare the emission potential of the four targets in direct comparison. Experimental results of the LPP are discussed with respect to the 6.x nm inband energy, which are consistent with the theoretical considerations. It is shown that the line radiators Al and Mg seem to be suitable emitters with comparable brightness to Gd- or Tb-based sources. The measured conversion efficiency of the Mg65Cu25Gd10 target reaches 80% of that of the pure Gd LPP although the Gd fraction is only 2% (atom percent).
- 21 January 2019
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 26 (2) , 430-438
Scanning transmission X-ray microscopy with efficient X-ray fluorescence detection (STXM-XRF) for biomedical applications in the soft and tender energy range
Scanning transmission X-ray microscopy, especially in combination with X-ray fluorescence detection (STXM-XRF) in the soft X-ray energy range, is becoming an increasingly important tool for life sciences. Using X-ray fluorescence detection, the study of biochemical mechanisms becomes accessible. As biological matrices generally have a low fluorescence yield and thus a low fluorescence signal, high detector efficiency (e.g. large solid angle) is indispensable for avoiding long measurement times and radiation damage. Here, the new AnImaX STXM-XRF microscope equipped with a large solid angle of detection enabling fast scans and the first proof-of-principle measurements on biomedical samples are described. In addition, characterization measurements for future quantitative elemental imaging are presented.
- 21 January 2019
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 26 (2) , 430-438
Scanning transmission X-ray microscopy with efficient X-ray fluorescence detection (STXM-XRF) for biomedical applications in the soft and tender energy range
Scanning transmission X-ray microscopy, especially in combination with X-ray fluorescence detection (STXM-XRF) in the soft X-ray energy range, is becoming an increasingly important tool for life sciences. Using X-ray fluorescence detection, the study of biochemical mechanisms becomes accessible. As biological matrices generally have a low fluorescence yield and thus a low fluorescence signal, high detector efficiency (e.g. large solid angle) is indispensable for avoiding long measurement times and radiation damage. Here, the new AnImaX STXM-XRF microscope equipped with a large solid angle of detection enabling fast scans and the first proof-of-principle measurements on biomedical samples are described. In addition, characterization measurements for future quantitative elemental imaging are presented.
- 10 August 2018
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 230-231
A Portable Endstation for Analytical X-ray Microscopy Using Soft X-ray Synchrotron Radiation
A Portable Endstation for Analytical X-ray Microscopy Using Soft X-ray Synchrotron Radiation - Volume 24 Issue S2
- 10 August 2018
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 230-231
A Portable Endstation for Analytical X-ray Microscopy Using Soft X-ray Synchrotron Radiation
A Portable Endstation for Analytical X-ray Microscopy Using Soft X-ray Synchrotron Radiation - Volume 24 Issue S2