    Reduced NEXI protocol for the quantification of human gray matter microstructure on the Connectome 2.0 scanner

    by Quentin Uhl, Tommaso Pavan, Julianna Gerold, Kwok-Shing Chan, Yohan Jun, Shohei Fujita, Aneri Bhatt, Yixin Ma, Qiaochu Wang, Hong-Hsi Lee, et al.

    Biophysical diffusion MRI models such as Neurite Exchange Imaging (NEXI) are essential for probing gray matter microstructure, estimating compartment diffusivities (Di, De), neurite fraction (f), and exchange time (tex). However, NEXI multi-shell, multi-diffusion-time requirements lead to prohibitively long acquisitions. Leveraging the Connectome 2.0 ultra-high gradient scanner, we developed a time-efficient protocol using an Explainable AI (XAI) framework. Combining XGBoost, SHAP, and Recursive Feature Elimination trained on synthetic signals, XAI identified an optimal 8-feature subset, halving scan time from 27 to 14 minutes. Validated in vivo in 7 healthy participants, the XAI protocol was benchmarked against the full 15-feature acquisition, a Cramér-Rao Lower Bound (CRLB) theoretical optimum, and 2 expert-designed heuristics (“Mid-Range” and “Corner”). The XAI protocol robustly reproduced parameter estimates and maintained full protocol test–retest reproducibility. Remarkably, the data-driven XAI selection converged to the theoretical CRLB optimum. This validates XAI mathematical optimality while highlighting its primary advantage: achieving gold-standard optimization without requiring complex analytical Jacobians, making it effortlessly adaptable to numerically defined models or complex noise distributions where CRLB becomes intractable. Furthermore, XAI demonstrated superior in vivo robustness compared with heuristics: “Mid-Range” sampling yielded biased tex estimates due to insufficient temporal diversity, while “Corner” sampling yielded unstable Di estimates (fivefold higher coefficient of variation) due to noise sensitivity. Ultimately, this robust 14-minute NEXI protocol accelerates exchange-sensitive microstructural mapping, establishing a generalizable, model-agnostic optimization framework adaptable to future ultra-high gradient systems (e.g., Siemens Cima.X or GE MAGNUS) and existing clinical scanners.

  • SeqEyes : An Open‐Source Toolbox for Synchronized Waveform/Trajectory Visualization in Pulseq

    by Xingwang Yong, Zheng Liu, Yiyun Dong, Haotian Hong, Yuting Chen, Paul Dubovan, Qiang Liu, Jiye Kim, Unay Dorken Gallastegi, Yohan Jun, et al.

    Pulseq enables vendor‐neutral description of MRI pulse sequences in human‐readable .seq files and is widely used for sequence development and sharing. During design and debugging, rapid evaluation of sequence timing across RF pulses, gradient waveforms, and ADC events is essential. This is particularly challenging for non‐Cartesian acquisitions, where waveform timing does not readily reveal the underlying k ‐space trajectory. Existing tools, however, provide limited interactive capabilities for this task. Here, we introduce SeqEyes, an interactive viewer for Pulseq .seq files tailored for efficient sequence analysis. The software parses .seq files to provide synchronized visualization of RF, gradient, and ADC waveforms alongside their corresponding k ‐space trajectories. This establishes a direct link between sequence structure and sampling behavior within a single interface. The tool supports interactive navigation across time, TRs, and sequence blocks, as well as event‐level timing verification, visualization of Pulseq extensions, and diagnostic overlays. SeqEyes features a graphical user interface, complemented by command‐line, Python, and MATLAB interfaces for integration into existing research workflows. By unifying waveform and trajectory visualizations, this open‐source toolbox optimizes the routine validation of Pulseq sequences, ultimately reducing the barrier to developing and sharing complex MRI acquisitions.

  • PRIME: Phase reversed interleaved multi-Echo acquisition enables highly accelerated distortion-corrected diffusion MRI

    by Yohan Jun, Qiang Liu, Ting Gong, Jaejin Cho, Shohei Fujita, Xingwang Yong, Congyu Liao, Marianna E. Schmidt, Shahin Nasr, Camilo Jaimes, et al.


  • 3D-QALAS synthetic MRI with Zero-DeepSub in children: initial experience including post-contrast imaging feasibility

    by Suely Fazio Ferraciolli, Yohan Jun, Sergio Valencia, Valeria Pena Trujillo, Harry Griffin, Shohei Fujita, Eugene Milshteyn, Berkin Bilgic, Camilo Jaimes

    Background Magnetic resonance imaging (MRI) in children requires multiple sequences, leading to lengthy exams and motion-related challenges. Synthetic MRI generates multiple contrasts from a single acquisition, and integration of 3D-quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS) sequence with scan-specific deep-learning-based subspace reconstruction (Zero-DeepSub) enables high-resolution isotropic imaging with potential clinical utility. Objective To evaluate synthetic images generated from a 3D-QALAS sequence with Zero-DeepSub relative to conventional MRI sequences in pediatric brain MRI. Materials and methods This prospective initial experience included 26 pediatric patients (mean age 8.4 years) who underwent clinically indicated brain MRI between November 2023 and January 2024. Synthetic T1-weighted, T2-weighted, and fluid-attenuated inversion recovery (FLAIR) images were generated from quantitative maps using 3D-QALAS with Zero-DeepSub reconstruction. Two neuroradiologists independently assessed seven predefined imaging findings on synthetic and conventional images, with discrepancies adjudicated by a third reader. This reader also performed a semiquantitative evaluation of image quality using a 5-point Likert scale. Statistical analysis included descriptive statistics, interobserver agreement (Cohen’s kappa), and Wilcoxon signed-rank tests; positive predictive value (PPV) and negative predictive value (NPV) were also calculated. Results Synthetic images showed high sensitivity and specificity for mass/lesion, encephalomalacia, and collections, with perfect reader agreement. Gliosis demonstrated high sensitivity but moderate specificity for one reader. Abnormal enhancement had the lowest sensitivity (0.40). Interobserver agreement was moderate for gliosis (κ=0.55) and almost perfect (κ=0.83–1.00) for other findings. Semiquantitative evaluation revealed no significant difference between synthetic and conventional FLAIR, T1-weighted imaging, or post-contrast sequences (P>0.1), while conventional T2-weighted imaging was significantly superior (P<0.001). Conclusion 3D-QALAS with Zero-DeepSub reconstruction enables the synthesis of high-resolution, clinically interpretable brain images in pediatric patients, including post-contrast sequences. While conventional T2-weighted imaging remained superior, other synthetic contrasts were rated comparable to conventional images. This promising technique holds potential to reduce scan times in pediatric neuroimaging protocols, but further optimization and validation are required before clinical implementation. Graphical abstract


  • Multishot Dual Polarity GRAPPA : Robust Nyquist Ghost Correction for Multishot EPI

    by Yuancheng Jiang, Yohan Jun, Qiang Liu, Wen Zhong, Yogesh Rathi, Hua Guo, Berkin Bilgic

    Purpose: This work aims to develop a robust Nyquist ghost correction method for multishot echo‐planar imaging (EPI). The method helps correct challenging Nyquist ghosts, particularly on scanners with high‐performance gradients or ultra‐high fields. Methods: A method for multishot EPI ghost correction, called multishot dual‐polarity GRAPPA (msDPG), is developed by extending the DPG concept to multishot readouts. msDPG employs tailored DPG kernels to address high‐order phase differences between two EPI readout polarities, which cannot be fully addressed using linear phase correction (LPC) or non‐linear phase correction (nLPC). Advanced regularizers can be readily employed with the proposed msDPG for physiologic inter‐shot phase variation correction during reconstruction. Additionally, a calibration refinement method is proposed to improve the quality of the DPG calibration data and enhance reconstruction performance. Results: Phantom and in vivo experiments on scanners with high‐performance gradients and ultra‐high fields demonstrated that msDPG achieved superior ghost correction performance than LPC and nLPC, reducing the ghost‐to‐signal ratio (GSR) by over 50%. Compared to conventional DPG, msDPG provided images with lower noise amplification, particularly for acquisitions with large in‐plane acceleration. Consequently, high‐fidelity, submillimeter diffusion images were obtained using msDPG with regularized reconstruction. Conclusion: The proposed msDPG provides a robust Nyquist ghost correction method for multishot EPI, enabling submillimeter imaging with improved fidelity.


  • Open Access

    Omni-QALAS: Optimized Multiparametric Imaging for Simultaneous T1, T2 and Myelin Water Mapping

    by Shizhuo Li, Unay Dorken Gallastegi, Shohei Fujita, Yuting Chen, Pengcheng Xu, Yangsean Choi, Borjan Gagoski, Huihui Ye, Huafeng Liu, Berkin Bilgic, et al.

    Purpose: To improve the accuracy of multiparametric estimation, including myelin water fraction (MWF) quantification, and reduce scan time in 3D-QALAS by optimizing sequence parameters, using a self-supervised multilayer perceptron network. Methods: We jointly optimize flip angles, T2 preparation durations, and sequence gaps for T1 recovery using a self-supervised MLP trained to minimize a Cramer-Rao bound-based loss function, with explicit constraints on total scan time. The optimization targets white matter, gray matter, and myelin water tissues, and its performance was validated through simulation, phantom, and in vivo experiments. Results: Building on our previously proposed MWF-QALAS method for simultaneous MWF, T1, and T2 mapping, the optimized sequence reduces the number of readouts from six to five and achieves a scan time nearly one minute shorter, while also yielding higher T1 and T2 accuracy and improved MWF maps. This sequence enables simultaneous multiparametric quantification, including MWF, at 1 mm isotropic resolution within 3 minutes and 30 seconds. Conclusion: This study demonstrated that optimizing sequence parameters using a self-supervised MLP network improved T1, T2 and MWF estimation accuracy, while reducing scan time.


  • MIMOSA : Multi‐Parametric Imaging Using Multiple‐Echoes With Optimized Simultaneous Acquisition for Highly‐Efficient Quantitative MRI

    by Yuting Chen, Yohan Jun, Amir Heydari, Xingwang Yong, Jiye Kim, Jongho Lee, Huafeng Liu, Huihui Ye, Borjan Gagoski, Shohei Fujita, et al.

    Purpose: To develop a new sequence, MIMOSA, for highly efficient T 1 , T 2 , T 2 *, proton density (PD), and source separation quantitative susceptibility mapping (QSM). Methods: MIMOSA was developed based on 3D quantification using an interleaved Look‐Locker acquisition sequence with a T 2 preparation pulse (3D‐QALAS) by combining 3D turbo Fast Low Angle Shot (FLASH) and multi‐echo gradient echo acquisition modules with a spiral‐like Cartesian trajectory to facilitate highly efficient acquisition. Simulations were performed to optimize the sequence. A multi‐contrast/‐slice zero‐shot self‐supervised learning algorithm was employed for reconstruction. The accuracy of quantitative mapping was assessed by comparing MIMOSA with 3D‐QALAS and reference techniques in both ISMRM/NIST phantom and in vivo experiments. MIMOSA's acceleration capability was assessed at R = 3.3, 6.5, and 11.8 in in vivo experiments, with repeatability assessed through scan‐rescan studies. Beyond the 3 T experiments, mesoscale quantitative mapping was performed at 750 μm isotropic resolution at 7 T. Results: Simulations demonstrated that MIMOSA achieved improved parameter estimation accuracy compared to 3D‐QALAS. Phantom experiments indicated that MIMOSA exhibited better agreement with the reference techniques than 3D‐QALAS. In vivo experiments demonstrated that an acceleration factor of up to R = 11.8‐fold can be achieved while preserving parameter estimation accuracy, with intra‐class correlation coefficients of 0.998 ( T 1 ), 0.973 ( T 2 ), 0.947 ( T 2 *), 0.992 (QSM), 0.987 (paramagnetic susceptibility), and 0.977 (diamagnetic susceptibility) in scan‐rescan studies. Whole‐brain T 1 , T 2 , T 2 *, PD, and source separation QSM were obtained with 1 mm isotropic resolution in 3 min at 3 T and 750 μm isotropic resolution in 13 min at 7 T. Conclusion: MIMOSA demonstrated potential for highly efficient and repeatable multi‐parametric mapping.


  • Vendor‐agnostic 3D multiparametric relaxometry improves cross‐platform reproducibility

    by Shohei Fujita, Borjan Gagoski, Jon‐Fredrik Nielsen, Maxim Zaitsev, Yohan Jun, Jaejin Cho, Xingwang Yong, Quentin Uhl, Pengcheng Xu, Eugene Milshteyn, et al.

    Purpose: To address the unmet need for a cross‐platform, multiparametric relaxometry technique to facilitate data harmonization across different sites.Methods: A simultaneous T1 and T2 mapping technique, 3D quantification using an interleaved Look–Locker acquisition sequence with a T2 preparation pulse (3D‐QALAS), was implemented using the open‐source vendor‐agnostic Pulseq platform. The technique was tested on four 3 T scanners from two vendors across two sites, evaluating cross‐scanner, cross‐software version, cross‐site, and cross‐vendor variability. The cross‐vendor reproducibility was assessed using both the vendor‐native and Pulseq‐based implementations. A National Institute of Standards and Technology/International Society for Magnetic Resonance in Medicine system phantom and three human subjects were evaluated. The acquired T1 and T2 maps from the different 3D‐QALAS runs were compared using linear regression, Bland–Altman plots, coefficient of variation (CV), and intraclass correlation coefficient (ICC).Results: Pulseq‐QALAS demonstrated high linearity (R2 = 0.994 for T1, R2 = 0.999 for T2) and correlation (ICC = 0.99 [0.98–0.99]) against temperature‐corrected NMR reference values in the system phantom. Compared to vendor‐native sequences, the Pulseq implementation showed significantly higher reproducibility in phantom T2 values (CV, 2.3% vs. 17%; p < 0.001), and improved T1 reproducibility (CV, 3.4% vs. 4.9%; p = 0.71, not significant). The Pulseq implementation reduced cross‐vendor variability to a level comparable to cross‐scanner (within‐vendor) variability. In vivo, Pulseq‐QALAS exhibited reduced cross‐vendor variability, particularly for T2 values in gray matter with a twofold reduction in variability (CV, 2.3 vs. 5.9%; p < 0.001).Conclusion: An identical implementation across different scanners and vendors, combined with consistent reconstruction and fitting pipelines, can improve relaxometry measurement reproducibility across platforms.


  • Zero‐DeepSub: Zero‐shot deep subspace reconstruction for rapid multiparametric quantitative MRI using 3D‐QALAS

    by Yohan Jun, Yamin Arefeen, Jaejin Cho, Shohei Fujita, Xiaoqing Wang, P. Ellen Grant, Borjan Gagoski, Camilo Jaimes, Michael S. Gee, Berkin Bilgic

    Purpose: To develop and evaluate methods for (1) reconstructing 3D‐quantification using an interleaved Look‐Locker acquisition sequence with T2 preparation pulse (3D‐QALAS) time‐series images using a low‐rank subspace method, which enables accurate and rapid T1 and T2 mapping, and (2) improving the fidelity of subspace QALAS by combining scan‐specific deep‐learning‐based reconstruction and subspace modeling.Theory and Methods: A low‐rank subspace method for 3D‐QALAS (i.e., subspace QALAS) and zero‐shot deep‐learning subspace method (i.e., Zero‐DeepSub) were proposed for rapid and high fidelity T1 and T2 mapping and time‐resolved imaging using 3D‐QALAS. Using an ISMRM/NIST system phantom, the accuracy and reproducibility of the T1 and T2 maps estimated using the proposed methods were evaluated by comparing them with reference techniques. The reconstruction performance of the proposed subspace QALAS using Zero‐DeepSub was evaluated in vivo and compared with conventional QALAS at high reduction factors of up to nine‐fold.Results: Phantom experiments showed that subspace QALAS had good linearity with respect to the reference methods while reducing biases and improving precision compared to conventional QALAS, especially for T2 maps. Moreover, in vivo results demonstrated that subspace QALAS had better g‐factor maps and could reduce voxel blurring, noise, and artifacts compared to conventional QALAS and showed robust performance at up to nine‐fold acceleration with Zero‐DeepSub, which enabled whole‐brain T1, T2, and PD mapping at 1 mm isotropic resolution within 2 min of scan time.Conclusion: The proposed subspace QALAS along with Zero‐DeepSub enabled high fidelity and rapid whole‐brain multiparametric quantification and time‐resolved imaging.