PSPatrick Schuenke

Patrick Schuenke

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Patrick Schuenke has a total of 153 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    MRpro: Open Framework for Model‐Based, Learned, and Quantitative MR Imaging—Application to Low‐Field MRI

    by Felix Frederik Zimmermann, Patrick Schuenke, Christoph S. Aigner, Bill A. Bernhardt, Mara Guastini, Johannes Hammacher, Helge Herthum, Noah Jaitner, Andreas Kofler, Leonid Lunin, et al.

    MRpro is an open‐source framework for MR image reconstruction and quantitative parameter estimation, with particular relevance to low‐field MRI. Built on PyTorch, it supports modern deep‐learning reconstructions and standardized data exchange through ISMRMRD for raw k‐space data and DICOM and NIfTI for reconstructed images and parameter maps. This facilitates integration into existing pipelines and the use of data from different devices. MRpro provides unified data structures for the consistent manipulation of MR datasets and associated metadata, together with a library of composable operators, proximable functionals, and optimization algorithms. The operator library includes a unified Fourier operator for all common trajectories and operators specifically developed for low‐field applications, such as a B‐correction operator. Together, these components underpin ready‐to‐use implementations of key reconstruction algorithms. For deep learning, MRpro includes data‐consistency layers, differentiable optimization layers, state‐of‐the‐art backbone networks, and access to public datasets to facilitate reproducibility. Automated quality control supports collaborative development. We demonstrate MRpro for automatic reconstruction, iterative SENSE, deep‐learning‐based reconstruction, and quantitative parameter estimation. For selected Cartesian and non‐Cartesian tasks, iterative SENSE reconstructions from MRpro differed from those obtained with BART, SigPy, and MRIReco by less than 3% relative RMSE. Further applications use public and simulated datasets and measured low‐field data acquired at 0.3 T, 0.6 T, and 47 mT. MRpro provides a reproducible and maintainable foundation for future MR imaging research.

  • Open Access

    Measuring cerebral glucose metabolism by chemical exchange-sensitive spin-lock (CESL) MRI of 2-deoxy-D-glucose in rodents

    by Philipp Boehm-Sturm, Patrick Schuenke, Marco Foddis, Susanne Mueller, Stefan P. Koch, Daniel J. Beard, Paul Holloway, Amin Mottahedin, Leif Schröder, Alastair M. Buchan, et al.

    Magnetic resonance imaging (MRI) of glucose metabolism shows significant potential for identifying disease biomarkers and monitoring therapeutic responses in neurological conditions. Here, we present a protocol utilizing chemical exchange-sensitive spin-lock (CESL) MRI with the glucose analogue 2-deoxy-D-glucose (2DG) in the rat brain. We employed this method to characterize metabolic changes in ischemic tissue in a rat model of stroke. However, the utility of the technique is not limited to stroke and may be adapted to other disease models with minimal modifications. Previous research has demonstrated that CESL MRI is sensitive to various glucose analogs, including regular D-glucose, which is suitable for human application. Consequently, our protocol provides a foundation for a wide range of future applications in both basic and translational research, with potential utility in animal models and, eventually, human studies.

  • Open Access

    Physics-Informed Deep Learning for Shear Wave Speed Estimation in MR Elastography

    by Stefan Martin, Jakob Schattenfroh, Patrick Schuenke, Felix Frederik Zimmermann, Ingolf Sack, Christoph Kolbitsch, Andreas Kofler

    Objective: Magnetic Resonance Elastography (MRE) is a non-invasive imaging technique for mapping biomechanical properties of in vivo tissue, including shear wave speed (SWS), but involves intrinsically slow data acquisition and an ill-posed wave inversion. Instead of relying on handcrafted image priors, we propose a data-driven approach jointly combining image reconstruction and MRE inversion for robust SWS estimation from undersampled k-space data. Methods: Our physics-informed reconstruction framework comprises two blocks: a model-based neural network (NN)-regularized reconstruction module and a phase-gradient inversion (k-MDEV) calculating SWS from the reconstructed images. Concatenating both blocks yields an end-to-end trainable method to estimate SWS directly from measured k-space data. We evaluated the method on retrospectively highly undersampled brain MRE data and compared it to a total variation (TV) minimization-based approach. We assessed the impact of end-to-end training (qualitative images and SWS maps as targets) versus pre-training (qualitative images as targets) and applied the method also to in vivo data. Results: Our approach significantly reduces NRMSE by 30% compared to TV. End-to-end training improves SWS estimation over separate image reconstruction and SWS calculation. Conclusion: Accurate SWS quantification is possible at acceleration factors up to 19. Our method significantly outperforms TV, highlighting the need for data-driven regularization in this challenging MR problem. Further, our approach successfully generalizes to in vivo data. Significance: We present the first end-to-end trainable MRE reconstruction method for estimating SWS maps directly from k-space. NN-based reconstruction can enable rapid stiffness mapping for dynamic studies, functional imaging, and real-time clinical feedback.


  • Open Access

    2-deoxy-D-glucose chemical exchange-sensitive spin-lock MRI of cerebral glucose metabolism after transient focal stroke in the rat

    by Philipp Boehm-Sturm, Patrick Schuenke, Marco Foddis, Susanne Mueller, Stefan P Koch, Daniel J Beard, Paul Holloway, Amin Mottahedin, Leif Schröder, Alastair M Buchan, et al.

    Rapid breakdown of cerebral glucose metabolism is a hallmark in stroke pathology. Metabolic activity delineates the penumbra from the infarct core, representing tissue that is potentially salvageable by therapeutic interventions. Tools to image dynamics of glucose and its spatial distribution could provide biomarkers of disease severity and of the success of therapeutic interventions. Here, we developed a new protocol to measure glucose transport and metabolism in a rat model of stroke using chemical exchange-sensitive spin-lock (CESL) MRI of the glucose analogue 2-deoxy-D-glucose (2DG). We further implemented a protocol that combines 2DG-CESL-MRI with perfusion and diffusion MRI to relate this new signal to established definitions of hypoperfused tissue, cytotoxic edema and the penumbra. We found that 2DG-CESL-MRI provides a biomarker of disturbed glucose transport and metabolism after stroke with high effect size. This is the first study to investigate CESL MRI of 2DG in the context of transport and metabolism imaging in rodent stroke.


  • Open Access

    Open-source cardiac magnetic resonance fingerprinting

    by Patrick Schuenke, Catarina Redshaw Kranich, Max Lutz, Jakob Schattenfroh, Matthias Anders, Philine Reisdorf, Jeanette Schulz-Menger, Ingolf Sack, Jesse Hamilton, Nicole Seiberlich, et al.

    Purpose: Cardiac magnetic resonance fingerprinting (cMRF) is a powerful quantitative imaging technique that provides multi-parametric diagnostic information. Here, we introduce an open-source framework for cardiac MRF including open-source pulse sequences, image reconstruction, and parameter estimation tools that are needed for the processing of the data. Methods: A 2D cMRF sequence with a variable-density spiral readout is implemented using the open-source and vendor-agnostic sequence format Pulseq. Cardiac triggering is used to synchronize acquisition with the rest period of the heart. $$T_1$$ T 1 inversion and $$T_2$$ T 2 preparation pulses are added to ensure accurate parameter estimation. Data acquisition is carried out over 15 heartbeats. The images showing the signal changes over time are reconstructed and matched to a pre-calculated signal dictionary. In addition to the cMRF sequence, spin-echo reference sequences for quality control in phantoms are provided. The method is evaluated in phantom experiments using a T1MES phantom on four different scanners. In vivo experiments were performed to compare the open-source cMRF sequence with a vendor-specific cMRF sequence and clinical sequences used for $$T_1$$ T 1 and $$T_2$$ T 2 mapping of the heart. Three volunteers were imaged on two different scanners. Results: The error of $$T_1$$ T 1 and $$T_2$$ T 2 over all tissue types present in the T1MES phantom was comparable between all four scanners and on average 4.50 ± 2.48%. $$T_1$$ T 1 and $$T_2$$ T 2 maps obtained in vivo were comparable between the open-source and vendor-specific implementation of cMRF. Conclusion: The proposed open-source cMRF implementation enables accurate parameter estimation across multiple different scanners. Sequence files, image reconstruction, and parameter estimation scripts are available for reproducible quantitative MRI.


  • Open Access

    The Pulseq-CEST Library: definition of preparations and simulations, example data, and example evaluations

    by Alexander Liebeskind, Jan Rüdiger Schüre, Moritz Simon Fabian, Simon Weinmüller, Patrick Schünke, Vladimir Golkov, Daniel Cremers, Moritz Zaiss

    Objectives: Despite prevalent use of chemical exchange saturation transfer (CEST) MRI, standardization remains elusive. Imaging depends heavily on parameters dictating radiofrequency (RF) events, gradients, and apparent diffusion coefficient (ADC). We present the Pulseq-CEST Library, a repository of CEST preparation and simulation definitions, including example data and evaluations, that provides a common basis for reproducible research, rapid prototyping, and in silico deep learning training data generation. Materials and methods: A Pulseq-CEST experiment requires (i) a CEST preparation sequence, (ii) a Bloch–McConnell parameter set, (iii) a Bloch–McConnell simulation, and (iv) an evaluation script. Pulseq-CEST utilizes the Bloch–McConnell equations to model in vitro and in vivo conditions. Using this model, a candidate sequence or environment can be held constant while varying other inputs, enabling robust testing. Results: Data were compared for amide proton transfer weighted (APTw) and water shift and B1 (WASABI) protocols using a five-tube phantom and simulated environments. Real and simulated data matched anticipated spectral shapes and local peak characteristics. The Pulseq-CEST Library supports similar experiments with common sequences and environments to assess new protocols and sample data. Discussion: The Pulseq-CEST Library provides a flexible mechanism for standardizing and prototyping CEST sequences, facilitating collaborative development. With the capability for expansion, including open-source incorporation of new sequences and environments, the library accelerates the invention and spread of novel CEST and other saturation transfer approaches, such as relayed NOEs (rNOEs) and semisolid magnetization transfer contrast (MTC) methods.


  • Open Access

    2-deoxy-D-glucose chemical exchange-sensitive spin-lock MRI of cerebral glucose metabolism after stroke in the rat

    by Philipp Boehm-Sturm, Patrick Schuenke, Marco Foddis, Susanne Mueller, Stefan P. Koch, Daniel J. Beard, Paul Holloway, Amin Mottahedin, Leif Schroeder, Alastair M. Buchan, et al.

    Rapid breakdown of cerebral glucose metabolism is a hallmark in stroke pathology. Metabolic activity delineates the penumbra from the infarct core, representing tissue that is potentially salvageable by therapeutic interventions. Tools to image dynamics of glucose and its spatial distribution could provide biomarkers of disease severity and of the success of therapeutic interventions. Here, we developed a new protocol to measure glucose metabolism in a rat model of stroke using chemical exchange-sensitive spin-lock (CESL) MRI of the glucose analog 2-deoxy-D-glucose (2DG). We further implemented a protocol that combines 2DG-CESL-MRI with perfusion and diffusion MRI to relate this new signal to established definitions of hypoperfused tissue, cytotoxic edema and the penumbra. We found that 2DG-CESL-MRI provides a biomarker of disturbed glucose metabolism after stroke with high effect size. This is the first study to investigate CESL MRI of 2DG in the context of metabolism imaging in rodent stroke.


  • Open Access

    PINQI: An End-to-End Physics-Informed Approach to Learned Quantitative MRI Reconstruction

    by Felix F. Zimmermann, Christoph Kolbitsch, Patrick Schuenke, Andreas Kofler

    Quantitative Magnetic Resonance Imaging (qMRI) enables the reproducible measurement of biophysical parameters in tissue. The challenge lies in solving a nonlinear, ill-posed inverse problem to obtain the desired tissue parameter maps from acquired raw data. While various learned and non-learned approaches have been proposed, the existing learned methods fail to fully exploit the prior knowledge about the underlying MR physics, i.e. the signal model and the acquisition model. In this paper, we propose PINQI, a novel qMRI reconstruction method that integrates the knowledge about the signal, acquisition model, and learned regularization into a single end-to-end trainable neural network. Our approach is based on unrolled alternating optimization, utilizing differentiable optimization blocks to solve inner linear and non-linear optimization tasks, as well as convolutional layers for regularization of the intermediate qualitative images and parameter maps. This design enables PINQI to leverage the advantages of both the signal model and learned regularization. We evaluate the performance of our proposed network by comparing it with recently published approaches in the context of highly undersampled $T_{1}$ -mapping, using both a simulated brain dataset, as well as real scanner data acquired from a physical phantom and in-vivo data from healthy volunteers. The results demonstrate the superiority of our proposed solution over existing methods and highlight the effectiveness of our method in real-world scenarios.


  • Open Access

    3D whole heart k-space-based super-resolution cardiac T1 mapping using rotated stacks

    by Simone Hufnagel, Patrick Schuenke, Jeanette Schulz-Menger, Tobias Schaeffter, Christoph Kolbitsch

    Objective . To provide three-dimensional (3D) whole-heart high-resolution isotropic cardiac T1 maps using a k-space-based through-plane super-resolution reconstruction (SRR) with rotated multi-slice stacks. Approach . Due to limited SNR and cardiac motion, often only 2D T1 maps with low through-plane resolution (4–8 mm) can be obtained. Previous approaches used SRR to calculate 3D high-resolution isotropic cardiac T1 maps. However, they were limited to the ventricles. The proposed approach acquires rotated stacks in long-axis orientation with high in-plane resolution but low through-plane resolution. This results in radially overlapping stacks from which high-resolution T1 maps of the whole heart are reconstructed using a k-space-based SRR framework considering the complete acquisition model. Cardiac and residual respiratory motion between different breath holds is estimated and incorporated into the reconstruction. The proposed approach was evaluated in simulations and phantom experiments and successfully applied to ten healthy subjects. Main results . 3D T1 maps of the whole heart were obtained in the same acquisition time as previous methods covering only the ventricles. T1 measurements were possible even for small structures, such as the atrial wall. The proposed approach provided accurate ( P > 0.4; R 2 > 0.99) and precise T1 values (SD of 64.32 ± 22.77 ms in the proposed approach, 44.73 ± 31.9 ms in the reference). The edge sharpness of the T1 maps was increased by 6.20% and 4.73% in simulation and phantom experiments, respectively. Contrast-to-noise ratios between the septum and blood pool increased by 14.50% in in vivo measurements with a k-space compared to an image-space-based SRR. Significance . The proposed approach provided whole-heart high-resolution 1.3 mm isotropic T1 maps in an overall acquisition time of approximately three minutes. Small structures, such as the atrial and right ventricular walls, could be visualized in the T1 maps.


  • Open Access

    Simulation of acquisition shifts in T2 weighted fluid-attenuated inversion recovery magnetic resonance images to stress test artificial intelligence segmentation networks

    by Christiane Posselt, Mehmet Yigit Avci, Mehmet Yigitsoy, Patrick Schuenke, Christoph Kolbitsch, Tobias Schaeffter, Stefanie Remmele

    PurposeTo provide a simulation framework for routine neuroimaging test data, which allows for “stress testing” of deep segmentation networks against acquisition shifts that commonly occur in clinical practice for T2 weighted (T2w) fluid-attenuated inversion recovery magnetic resonance imaging protocols.ApproachThe approach simulates “acquisition shift derivatives” of MR images based on MR signal equations. Experiments comprise the validation of the simulated images by real MR scans and example stress tests on state-of-the-art multiple sclerosis lesion segmentation networks to explore a generic model function to describe the F1 score in dependence of the contrast-affecting sequence parameters echo time (TE) and inversion time (TI).ResultsThe differences between real and simulated images range up to 19% in gray and white matter for extreme parameter settings. For the segmentation networks under test, the F1 score dependency on TE and TI can be well described by quadratic model functions (R2>0.9). The coefficients of the model functions indicate that changes of TE have more influence on the model performance than TI.ConclusionsWe show that these deviations are in the range of values as may be caused by erroneous or individual differences in relaxation times as described by literature. The coefficients of the F1 model function allow for a quantitative comparison of the influences of TE and TI. Limitations arise mainly from tissues with a low baseline signal (like cerebrospinal fluid) and when the protocol contains contrast-affecting measures that cannot be modeled due to missing information in the DICOM header.